Skip to main content

UVIT safety checks

Project description

CanUVIT

To check whether a field can be safely observed with UVIT.

You can install the CanUVIT Python package using the following command.
pip install canuvit --upgrade

IMPORTANT: Even if you have CanUVIT already installed, make sure you use the latest version by running the above command. Current version of CanUVIT is shown on the badge below:

After installation, you can run CanUVIT on a Python command prompt or as a script. For example, if your primary instrument is UVIT and the RA, DEC coordinates of the field are (12:12:12, 12:12:12), you may run the CanUVIT package as follows.

>>> import canuvit
>>> canuvit.observe('uvit', '12:12:12', '12:12:12')

Note: In general, canuvit.observe(instrument, RA, DEC) where the instrument can be either 'uvit', 'sxt', 'czti', or 'laxpc' and RA and DEC field coordinates should be in sexagesimal format.

For the above example, you should get an output as shown below. Please also check the working directory for the output GALEX images with sources marked in the primary instrument field of view.

### VIS

ra_hms	dec_dms	mag	B-V	SpecType	VIS3	VIS2	VIS1	ND1	BK7

12:11:52.7568	+12:07:47.532	11.096	0.864	K1	1333.0	124.4	88.6	29.7	1624.9
12:12:22.944	+12:17:23.856	11.126	0.814	K0	1296.7	121.0	86.2	28.9	1580.6
12:11:35.016	+12:12:04.644	11.426	0.451	F5	1457.4	234.9	180.9	32.8	1915.2
12:11:01.656	+12:08:35.916	11.874	0.694	G5	754.3	89.1	69.2	16.8	950.9
12:11:11.5272	+12:03:14.04	12.177	0.322	F0	803.1	143.5	101.4	18.2	1061.7
12:12:05.5368	+12:19:09.768	12.268	0.787	K0	452.9	42.3	30.1	10.1	552.1


Safe filters: ['VIS3', 'VIS2', 'VIS1', 'ND1', 'BK7']


FUV observations seem to be absent! Using M_fuv = M_nuv - 1.65.


### NUV

sl_no     ra_hms       dec_dms      Mag  Mag_corrected silica  b4  b13  b15   n2 
----- ------------- -------------- ----- ------------- ------ ---- ---- ---- ----
    1 12:12:32.3946 +12:07:27.4144 19.32         19.32   1.86 0.41 0.50 0.14 0.10
    2 12:11:11.6503 +12:03:14.7794 16.25         16.25  31.75 6.99 8.57 2.35 1.75
    3 12:12:41.0882 +12:14:58.2679 16.15         16.15  34.66 7.63 9.36 2.56 1.91
    4 12:12:15.3493 +12:29:18.1277 19.50         19.50   1.59 0.35 0.43 0.12 0.09
    5 12:11:35.0116 +12:12:04.7063 16.47         16.47  25.93 5.70 7.00 1.92 1.43



Safe filters in NUV: ['Silica', 'NUV-grating', 'NUV-B4', 'NUV-B13', 'NUV-B15', 'NUV-N2']


### FUV 

sl_no     ra_hms       dec_dms      Mag  Mag_corrected  caf2  baf2 sapphire silica
----- ------------- -------------- ----- ------------- ----- ----- -------- ------
    1 12:12:32.3946 +12:07:27.4144 19.32         17.67  1.65  1.40     1.04   0.36
    2 12:11:11.6503 +12:03:14.7794 16.25         14.60 28.17 23.94    17.75   6.20
    3 12:12:41.0882 +12:14:58.2679 16.15         14.50 30.75 26.14    19.37   6.76
    4 12:12:15.3493 +12:29:18.1277 19.50         17.85  1.41  1.20     0.89   0.31
    5 12:11:35.0116 +12:12:04.7063 16.47         14.82 23.00 19.55    14.49   5.06




Safe filters in FUV: ['CaF2', 'FUV-grating', 'BaF2', 'Sapphire', 'Silica']

Please choose the VIS filters such that none of the stars in the field gives >4800 counts/second. Further, for good tracking of the aspect, there should be at least two stars within a 12 arcminute radius of the target with >30 counts/second (for good S/N) and <1000 counts/second (to avoid saturation) in the chosen filter. Please also avoid configuring multiple VIS filters.

Two additional functions are also available, which takes the same input arguments as canuvit.observe().

  • canuvit.observe_VIS(): to find safe VIS filters.
  • canuvit.observe_UV(): to find safe UV filters.

Command Line Interface

After installation with pip, you can also access CanUVIT from the command line. Here's an example:

canuvit -i uvit -r "12:12:12" -d "12:12:12"

The help page of the command-line tool can be accessed as follows:

canuvit -h
Usage: canuvit [OPTIONS]

  Program to check if a given coordinate can be safely observed using UVIT.

  Example usage:
  canuvit -r "13:12:14" -d "-14:15:13" 

Options:
  --all                           Check safety for all filters.  [default:
                                  all]
  --vis                           Check saftey for only visible filters.
  --uv                            Check safety for only UV filters.
  -r, --ra RA                     Right ascension of the coordinate. Format:
                                  hh:mm:ss[.ss] e.g. "00:54:53.45"  [required]
  -d, --dec DEC                   Declination of the coordinate. Format:
                                  [-]dd:mm:ss[.ss] e.g. "-37:41:03.23".
                                  [required]
  -i, --instrument [uvit|sxt|czti|laxpc]
                                  Instrument to check for.  [default: uvit]
  -v, --verbose                   Increase output verbosity.
  --version                       Show the version and exit.
  -h, --help                      Show this message and exit.

Acknowledgements

CanUVIT depends on the following web tools and API for its functioning.

Requirements

CanUVIT works with Python 3.6 or later. CanUVIT depends on the following packages:

  • astropy
  • astroquery
  • beautifulsoup4
  • click
  • matplotlib
  • numpy
  • requests

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

canuvit-0.4.5.tar.gz (972.9 kB view hashes)

Uploaded Source

Built Distribution

canuvit-0.4.5-py3-none-any.whl (18.6 kB view hashes)

Uploaded Python 3

Supported by