Skip to main content

Gurux DLMS library for Python.

Project description

See An Gurux for an overview.

Join the Gurux Community or follow @Gurux for project updates.

gurux_dlms library is a high-performance Python component that helps you to read you DLMS/COSEM compatible electricity, gas or water meters. We have try to make component so easy to use that you do not need understand protocol at all.

For more info check out Gurux.DLMS.

We are updating documentation on Gurux web page.

Read should read DLMS/COSEM FAQ first to get started. Read Instructions for making your own meter reading application or build own DLMS/COSEM meter/simulator/proxy.

If you have problems you can ask your questions in Gurux Forum.

You can use any connection (TCP, serial, PLC) library you want to. Gurux.DLMS classes only parse the data.

Before start

If you find an issue, please report it here: http://www.gurux.fi/project/issues/gurux.dlms.python

Simple example

First you need to install the library:

pip install gurux_dlms

Before use you must set following device parameters. Parameters are manufacturer spesific.

First import gurux_dlms. 
from gurux_dlms import *

All default parameters are given in constructor.
// Is used Logican Name or Short Name referencing.
client = GXDLMSClient(True)

HDLC addressing

Each meter has own server address. Server address is divided to Logical address and Physical address. Usually you can use value 1 for meter address. You can count server address from serial number of the meter. You can use GetServerAddress method for that.

//Count server address from serial number.
serverAddress = CGXDLMSClient.getServerAddress(Serial number)
//Count server address from logican and physical address.
serverAddress = CGXDLMSClient.getServerAddress2(logical Address, physical Address, Address size in bytes);

If you are using IEC handshake you must first send identify command and move to mode E.

Support for serial port is added later.

After you have set parameters you can try to connect to the meter. First you should send SNRM request and handle UA response. After that you will send AARQ request and handle AARE response.

reply = GXReplyData()
data = self.client.snrmRequest()
if data:
    self.readDLMSPacket(data, reply)
    self.client.parseUAResponse(reply.data)
    size = self.client.limits.maxInfoTX + 40
    self.replyBuff = bytearray(size)
reply.clear()
self.readDataBlock(self.client.aarqRequest(), reply)
self.client.parseAareResponse(reply.data)
reply.clear()
if self.client.authentication.value > Authentication.LOW.value:
    for it in self.client.getApplicationAssociationRequest():
        self.readDLMSPacket(it, reply)
    self.client.parseApplicationAssociationResponse(reply.data)

If parameters are right connection is made. Next you can read Association view and show all objects that meter can offer.

#Read Association View from the meter.
reply = GXReplyData()
self.readDataBlock(self.client.getObjectsRequest(), reply)
objects = self.client.parseObjects(reply.data, True)
converter = GXDLMSConverter.GXDLMSConverter()
converter.updateOBISCodeInformation(objects)

Now you can read wanted objects. After read you must close the connection by sending disconnecting request.

self.readDLMSPacket(self.client.disconnectRequest(), reply)
#Close media.
def readDLMSPacket2(self, data, reply):
if not data:
    return
notify = GXReplyData()
reply.error = 0
succeeded = False
rd = GXByteBuffer()
if not reply.isStreaming():
    self.writeTrace("TX: " + self.now() + "\t" + GXByteBuffer.hex(data), TraceLevel.VERBOSE)
    self.media.sendall(data)
msgPos = 0
count = 100
pos = 0
try:
    while not self.client.getData(rd, reply, notify):
        if notify.data.size != 0:
            if not notify.isMoreData():
                t = GXDLMSTranslator(TranslatorOutputType.SIMPLE_XML)
                xml = t.dataToXml(notify.data)
                print(xml)
                notify.clear()
                msgPos = rd.position
            continue
        rd.position = msgPos
        rd.set(self.media.recv(100))
    if pos == 3:
        raise ValueError("Failed to receive reply from the device in given time.")
    if pos != 0:
        print("Data send failed.  Try to resend " + str(pos) + "/3")
    ++pos
except Exception as e:
    self.writeTrace("RX: " + self.now() + "\t" + rd.__str__(), TraceLevel.ERROR)
    raise e
self.writeTrace("RX: " + self.now() + "\t" + rd.__str__(), TraceLevel.VERBOSE)
if reply.error != 0:
    raise GXDLMSException(reply.error)

Project details


Release history Release notifications | RSS feed

Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

gurux_dlms-1.0.54.tar.gz (245.0 kB view hashes)

Uploaded Source

Built Distribution

gurux_dlms-1.0.54-py3-none-any.whl (486.4 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page