Database and code to simulate heat pumps
Project description
hplib - heat pump library
Repository with code to
- build a database with relevant data from public Heatpump Keymark Datasets.
- identify efficiency parameters from the database with a least-square regression model, comparable to Schwamberger [1].
- simulate heat pump efficiency (COP) as well as electrical (P_el) & thermal power (P_th) and massflow (m_dot) as time series.
For the simulation, it is possible to calculate outputs of a specific manufacturer + model or alternatively for one of 6 different generic heat pump types.
[1] K. Schwamberger: „Modellbildung und Regelung von Gebäudeheizungsanlagen mit Wärmepumpen“, VDI Verlag, Düsseldorf, Fortschrittsberichte VDI Reihe 6 Nr. 263, 1991.
For reference purposes:
- DOI:
- Citation: Tjarko Tjaden, Hauke Hoops, Kai Rösken. (2021). RE-Lab-Projects/hplib: heat pump library (v1.8). Zenodo. https://doi.org/10.5281/zenodo.5521597
Documentation
If you're interested in how the database and parameters were calclulated, have a look into the Documentation HTML or Jupyter-Notebook. There you also find a simulation examples and a validation.
Heat pump models and Group IDs
The hplib_database.csv contains the following number of heat pump models, sorted by Group ID
[Group ID]: Count | Reglulated | On-Off |
---|---|---|
Outdoor Air / Water | [1]: 366 | [4]: 23 |
Brine / Water | [2]: 54 | [5]: 53 |
Water / Water | [3]: 0 | [6]: 10 |
Database
All resulting database CSV file are under .
The following columns are available for every heat pump of this library
Column | Description | Comment |
---|---|---|
Manufacturer | Name of the manufacturer | 30 manufacturers |
Model | Name of the heat pump model | 506 models |
Date | heat pump certification date | 2016-07-27 to 2021-03-10 |
Type | Type of heat pump model | Outdoor Air/Water, Brine/Water, Water/Water |
Subtype | Subtype of heat pump model | On-Off, Regulated |
Group ID | ID for combination of type and subtype | 1 - 6 |
Refrigerant | Refrigerant Type | R134a, R290, R32, R407c, R410a, other |
Mass of Refrigerant [kg] | Mass of Refrigerant | 0.15 to 14.5 kg |
SPL indoor [dBA] | Sound emissions indoor | 15 - 68 dBA |
SPL outdoor [dBA] | Sound emissions outdoor | 33 - 78 dBA |
PSB [W] | Eletrical power consumption, standby mode | 3 to 60 W |
Climate | Climate definition for set points, which were used for parameter identification | average, colder, warmer |
P_el_h_ref [W] | Electrical power at -7°C / 52°C | 881 to 23293 W |
P_th_h_ref [W] | Thermal heating power at -7°C / 52°C | 2400 to 69880 W |
p1-p4_P_th | Fit-Parameters for thermal power | - |
p1-p4_P_el | Fit-Parameters for electricl power | P_el = P_el_ref * (p1 * T_in + p2 * T_out + p3 + p4 * T_amb) |
p1-p4_COP | Fit-Parameters for COP | COP = p1 * T_in + p2 * T_out + p3 + p4 * T_amb |
p1-p4_EER | Fit-Parameters for EER | EER = p1 * T_in + p2 * T_out + p3 + p4 * T_amb |
MAPE_P_el | mean absolute percentage error for electrical input power (simulation vs. measurement) | average over all heat pump models = 16,3 % |
MAPE_COP | mean absolute percentage error for thermal input power (simulation vs. measurement) | average over all heat pump models = 9,8 % |
MAPE_P_th | mean absolute percentage error for coefficient of performance (simulation vs. measurement) | average over all heat pump models = 19,7 % |
Usage
- Get repository with pip:
pip install hplib
or:
- Download or clone repository:
git clone https://github.com/RE-Lab-Projects/hplib.git
- Create the environment:
conda env create --name hplib --file requirements.txt
Create some code with from hplib import hplib
and use the included functions hplib.load_database()
, hplib.get_parameters
, hplib.same_built_type()
, hplib.HeatPump
, hplib.HeatPump.simulate
, hplib.HeatingSystem.calc_brine_temp()
and hplib.HeatingSystem.calc_heating_dist_temp()
Hint: The csv files in the output
folder are for documentation and validation purpose. The code and database files, which are meant to be used for simulations, are located in the hplib
folder.
Input-Data
The European Heat Pump Association (EHPA) hosts a website with the results of laboratory measurements from the keymark certification process. For every heat pump model a pdf file can be downloaded from https://keymark.eu/en/products/heatpumps/certified-products.
This repository is based on all pdf files that were download for every manufacturer on 2021-03-12.
Further development & possibilities to collaborate
If you find errors or are interested in developing together on the heat pump library, please create an ISSUE and/or FORK this repository and create a PULL REQUEST.
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
Built Distribution
File details
Details for the file hplib-1.9.tar.gz
.
File metadata
- Download URL: hplib-1.9.tar.gz
- Upload date:
- Size: 265.8 kB
- Tags: Source
- Uploaded using Trusted Publishing? No
- Uploaded via: twine/4.0.1 CPython/3.9.13
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 81a0ba76c4c739ea9f5f7db7b7eb2dc72ab63df2731fc325d228357fbef63ae0 |
|
MD5 | e64218354fb52cf6067756d24968a5e7 |
|
BLAKE2b-256 | 3c0ea81d5bcfdceb22f0c1f636ec9567fad74769c073336071db85ea68fd9586 |
File details
Details for the file hplib-1.9-py3-none-any.whl
.
File metadata
- Download URL: hplib-1.9-py3-none-any.whl
- Upload date:
- Size: 245.9 kB
- Tags: Python 3
- Uploaded using Trusted Publishing? No
- Uploaded via: twine/4.0.1 CPython/3.9.13
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 958a4fd72b6a7d6bcba23177c829eecd3cb33686d3b51a7bc7a379432ca2b3f7 |
|
MD5 | 12fae45854060a73b92dde1545dca158 |
|
BLAKE2b-256 | 8496e1bc1c0cadb2492d41be1840fcf57c2aa99a30da0e90a40a0891bec7b20d |