Package to control ISMATEC products

Project description

ismatec

Python package to control ISMATEC products.

We are not affiliated with ISMATEC.

Supported products:

Reglo-CPF Digital

The package is not fully compatible with Windows 10.

Commands that don't work:

  • set the calibrated flow rate

Getting started

Check the examples folder for example script on how to use the RegloCPF and RegloICC modules.

To connect to the pump in Python, you need to know the comport of the pump when it is connected to the computer. To know this, before plugging the pump into the computer open the Windows Device Manager program and expand Ports. Then plug in the pump and see what new port appears, e.g. COM6. This is what you will use to create the RegloCPF or instance in Python to connect to and control the pump.

Serial settings and protocols

Connection settings according to the manual are

+----------------------+---------------------------------------------+
| Parameter            | Comment                                     |
+----------------------+---------------------------------------------+
| Baud rate            | 9600                                        |
+----------------------+---------------------------------------------+
| Parity               | None                                        |
+----------------------+---------------------------------------------+
| Handshaking          | None                                        |
+----------------------+---------------------------------------------+
| Data bits            | 8                                           |
+----------------------+---------------------------------------------+
| Stop bits            | 1                                           |
+----------------------+---------------------------------------------+
| Address              | Between 1 and 8                             |
+----------------------+---------------------------------------------+
| Physical connection  | RS232 IN (female): 9-pin D-socket on the    |
|                      | the real panel of the RegloCPF, connects    |
|                      | to PC via standard RS232 cable.             |
|                      | RS232 OUT (male): used to connect to other  |
|                      | pumps                                       |
+----------------------+---------------------------------------------+
| Message Terminators  | Command string is completed by a carriage   |
|                      | return (ASCII 13, <CR>). The pump confirms  |
|                      | most commands with an asterix *, Yes/No     |
|                      | inquiries are answered by + (yes) or - (no) |
|                      | Multi-digit replies are concluded by a      |
|                      | carriage return (ASCII 13, <CR>) and a line |
|                      | feed (ASCII 10, <LF>)                       |
+----------------------+---------------------------------------------+

Structure of commands:

The address is followed by a character. Some commands have additional parameters that always consist of 4 or 5 figures. The command string is completed by a carriage return (ASCII 13, ). The pump confirms most commands with an asterix *, Yes/No inquiries are answered by + (yes) or - (no). Multi-digit replies are concluded by a carriage return (ASCII 13, ) and a line feed (ASCII 10, ).

Incorrect commands are answered by #. If the pump is in the state of overload, each command is responded with #. Numerical values are confirmed as 3 to 5-digit figures. 4 or 5 digits are numerals, one digit is either a decimal point or a preceding blank space

For a full list of the protocols, check the operating manual: www.ismatec.com/images/pdf/manuals/REGLO_CPF_Digital_new.pdf

Reglo-ICC Digital Peristaltic Pump

Legacy and channel addressing mode are both supported. Event message reading is not supported so event messaging is disabled on instantiation of a RegloICC instance.

On testing, the following commands did not work:

  • set_pump_head_model_type_code
  • get_actual_calibration_volume

The following commands have not been implemented:

  • f - Get current volume/time flow rate (mL/min) - _GET_FLOW_RATE_VOLUME_TIME_MODE
  • f - Set RPM flow rate in volume/time mode (mL/min - _SET_FLOW_RATE_VOLUME_TIME_MODE
  • xv - Get time to dispense at a given volume at a given mL/min flow rate. - _GET_TIME_TO_DISPENSE_VOLUME_AT_FLOW_RATE
  • xw - Get time to dispense at a given volume at a given RPM - _GET_TIME_TO_DISPENSE_VOLUME_AT_RPM
  • xt - Change factory roller step volume for a particular roller count and tubing size using roller count (6,8,12) - _SET_FACTORY_ROLLER_STEP_VOLUME

Getting started

To connect to the pump in Python, you need to know the comport of the pump when it is connected to the computer. To know this, before plugging the pump into the computer open the Windows Device Manager program and expand Ports. Then plug in the pump and see what new port appears, e.g. COM6. This is what you will use to create the RegloICC instance in Python to connect to and control the pump.

Serial settings and protocols

Connection settings according to the manual are

+----------------------+---------------------------------------------+
| Parameter            | Comment                                     |
+----------------------+---------------------------------------------+
| Baud rate            | 9600                                        |
+----------------------+---------------------------------------------+
| Parity               | None                                        |
+----------------------+---------------------------------------------+
| Data bits            | 8                                           |
+----------------------+---------------------------------------------+
| Stop bits            | 1                                           |
+----------------------+---------------------------------------------+
| Address              | Between 1 and 8                             |
+----------------------+---------------------------------------------+
| Physical connection  | RS232 IN (female): 9-pin D-socket on the    |
|                      | the real panel of the RegloCPF, connects    |
|                      | to PC via standard RS232 cable.             |
|                      | RS232 OUT (male): used to connect to other  |
|                      | pumps                                       |
+----------------------+---------------------------------------------+

For a full list of the protocols, check the operating manual: http://www.ismatec.com/images/pdf/manuals/14-036_E_ISMATEC_REGLO_ICC_ENGLISH_REV.%20C.pdf

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distributions

No source distribution files available for this release.See tutorial on generating distribution archives.

Built Distribution

ismatec-1.1.3-py3-none-any.whl (40.0 kB view details)

Uploaded Python 3

File details

Details for the file ismatec-1.1.3-py3-none-any.whl.

File metadata

  • Download URL: ismatec-1.1.3-py3-none-any.whl
  • Upload date:
  • Size: 40.0 kB
  • Tags: Python 3
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/2.0.0 pkginfo/1.6.1 requests/2.25.1 setuptools/51.0.0 requests-toolbelt/0.9.1 tqdm/4.55.1 CPython/3.9.1

File hashes

Hashes for ismatec-1.1.3-py3-none-any.whl
Algorithm Hash digest
SHA256 42201961e55aed2e436d27e055343d06d84154f92dd9c5c60387340eeef71a35
MD5 5cc975faa494f6f101d6fa8dc53cb55c
BLAKE2b-256 e862269b1b9c05fee496e75ceb070a06663d77b8b1b17564441715e0fa73d3bc

See more details on using hashes here.