Generate clearance rules for KiCAD by a table.
Project description
This Python program converts a given table of voltage distances into KiCad design rules.
1 Installation
Install KiClearance directly from pyPI:
pip install kiclearance
2 Usage
2.1 Create a table ‘clearance.ods/xls/csv’ containing clearance distances
Create a table (name it clearance.ods/xls/csv) in your KiCad project directory with voltage clearances defined by your requirements (e.g. standards). Download and use this template as a guide: clearance.ods.
The table contains the distances from a potential to another in mm. The same net distance is optional. The default distance is 0.15 mm.
2.2 Define net classes in your KiCad project
Add the net classes to each connection in the circuit diagram.
Add the same net classes in the net classes of the PCB editor: KiCad PCB Editor: File -> Board Setup -> Design Rules -> Net classes
2.3 Run KiClearance
Navigate to the project folder with the KiCad project and the clearance.ods/.xls/.csv file. Open a terminal and execute :
python -m kiclearance
Now a file yourprojectname.kicad_dru is generated, which contains the rule sets.
Open your KiCad project, the rule sets are now stored and you can start the routing.
As the inner layers are exposed to less dirt and no air, the distance in the inner layers is halved by default. If this factor is to be set differently, this can be set with the following command (in the example: distance to 75%):
python -m kiclearance -i 0.75
To see help and options, run
python -m kiclearance --help
The following arguments are possible: -h, --help: Prints this information, -f, --project_folder (Optional): Path to the folder in which the project is located. Default: Folder in which this python script is located. -n, --project_name (Optional): Name of the kicad project (file prefix). Default: Script will look for a file with .kicad_pro in the set folder. -t, --table_file (Optional): Name (and ending) of the file containing the distance values. Default name: 'clearance'. -i, --factor_inner_layers (Optional): Reduced factor for the inner layers. Default: 0.5 -d, --min_track_distance (Optional): minimum track distance between two tracks on the same potential. Default: 0.15 mm.
3 Tips and tricks
If two network classes are assigned to a connection by mistake, this is displayed as an error in the Electrical Rules Checker (Inspect -> Electrical Rules Checker).
KiCad works through the rules from bottom to top: Once an applicable rule has been found, KiCad will not search for further rules. Keep this in mind when adding more own rules except from this script here.
4 Example
A complete example can be found here.
5 Documentation
Find the documentation here.
6 Troubleshooting
This program has so far been tested only on Linux and Windows.
Project details
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
Built Distribution
Hashes for kiclearance-0.1.1-py3-none-any.whl
Algorithm | Hash digest | |
---|---|---|
SHA256 | 29c6d9fb60fc0737ca0b6169d8b7e6f29c6490dbd72a49b75ff1da7ae5b0fd93 |
|
MD5 | 6b493fef059c08e1d5a5b584fb0054ca |
|
BLAKE2b-256 | 82cd3780aef37fa49951ed7b7edc47c3a66cfd10cd43de50ec8f335d56697eb7 |