Command line tool to access Modbus devices

Project description

Author:

favalex@gmail.com

Date:
2017-06-04
Version:
0.1
Manual section:

1

SYNOPSIS

modbus [-h] [-r REGISTERS] [-s SLAVE_ID] [-b BAUD] [-p STOP_BITS] [-v] device access [access …]

DESCRIPTION

modbus allows reading and writing registers of Modbus devices from the command line.

It can talk to both TCP and RTU (i.e. serial) devices and can encode and decode types larger than 16 bits (e.g. floats) into Modbus 16 bits registers.

Register definitions (consisting of a register address and its type) can be provided directly on the command line or loaded from a file and referred by symbolic name, for convenience.

modbus is implemented in python on top of the protocol implementation provided by the umodbus python library.

OPTIONS

device

/dev/ttyXXX for serial devices, or hostname[:port] for TCP devices

access

One or more read or write operations. See ACCESS SYNTAX below.

-r FILE, --registers=FILE

Read registers definitions from FILE.

-v, --verbose

Print on screen the bytes as transfered on the wire.

-b BAUD, --baud=BAUD

Set the baud rate for serial connections.

-p BITS, --stop-bits=BITS

Set the number of stop bits for serial connections.

-h, --help

Show this help message and exit.

ACCESS SYNTAX

[MODBUS_TYPE@]ADDRESS[/BINARY_TYPE][=VALUE]

MODBUS_TYPE = h|i|c|d

The modbus type, one of

code

name

size

writable

h

holding register

16 bits

yes

i

input register

16 bits

no

c

coil

1 bit

yes

d

discrete input

1 bit

no

ADDRESS = <number>

0-based register address

BINARY_TYPE = <pack format>

Any format description accepted by the python standard pack module. Some common formats are:

code

type

h

16 bits signed integer

H

16 bits unsigned integer

i

32 bits signed integer

I

32 bits unsigned integer

f

32 bits IEEE 754 float

The default byte order is big-endian, use a < prefix in the format to specify little-endian.

VALUE = <number>

The value to be written to the register. If not present, the register will be read instead.

EXAMPLES

h@39/I

read the 32-bits unsigned integer stored in holding registers at addresses 39 and 40

39/I

same as above (h is the default modbus type)

39/I=42

write the integer 42 to that register

39/I=0xcafe

the value can be specified in hexadecimal

c@5

read coil at address 5

h@24/f=6.78

write a floating point value to holding registers at addresses 24 and 25

REGISTERS FILE SYNTAX

A # starts a comment.

Each line contains a symbolic name followed by the register definition, separated by spaces.

SEE ALSO