Read data from sds011 sensor, gather purpleair and notion data and POST to an API
Project description
Installation
- Install the
monitor_air_quality
python package- This is best done in a
virtualenv
or withpip install --user monitor_air_quality
- This is best done in a
- Create a
~/.config/monitor_air_quality_config.yaml
file with config settings - Run
monitor_air_quality --help
to see the options
Usage
usage: monitor_air_quality.py [-h] [--fetch-local-aqi LOCATION]
[--fetch-notion-temperature LOCATION]
[--notion-sensor SENSOR_NAME]
[--fetch-purpleair-data LOCATION]
[--command COMMAND]
[--alert LOCATION,METRIC,THRESHOLD]
[--alert-on-temperature-inversion LOCATION,LOCATION]
[--output {print,debug,info,post}]
Gather and post or print air quality and temperature data
optional arguments:
-h, --help show this help message and exit
--fetch-local-aqi LOCATION
the local location to use when fetching local data
--fetch-notion-temperature LOCATION
the location to use when fetching the notion API for
temperature data
--notion-sensor SENSOR_NAME
the notion sensor name to fetch from
--fetch-purpleair-data LOCATION
the location to use when fetching purpleair data
--command COMMAND command to run to fetch remote data
--alert LOCATION,METRIC,THRESHOLD
comma delimited string of location,metric,threshold
--alert-on-temperature-inversion LOCATION,LOCATION
comma delimited string of indoor,outdoor location
names
--output {print,debug,info,post}
whether to print or post the results or give debug or
info output (default: print)
Examples:
--command "ssh pi@203.0.113.20 'monitor_air_quality --fetch-local-aqi upstairs'"
--fetch-local-aqi basement --alert basement,pm25,12
--notion-sensor "Upstairs hall Sensor" --fetch-notion-temperature upstairs
--fetch-purpleair-data outdoor
--alert-on-temperature-inversion upstairs,outdoor --notion-sensor "Upstairs hall Sensor" --fetch-notion-temperature upstairs --fetch-purpleair-data outdoor
--fetch-local-aqi basement --notion-sensor "Upstairs hall Sensor" --fetch-notion-temperature upstairs --fetch-purpleair-data outdoor --command "ssh -i /home/gene/Documents/monitor_air_quality/id_rsa pi@192.168.0.31 true" --alert upstairs,pm25,12 --alert-on-temperature-inversion upstairs,outdoor
Example outputs
Output print
{
"dt": "2021-09-12T13:25:26.460173",
"upstairs": {
"pm25": "4.2",
"pm10": "7.7",
"aqipm25": "18",
"aqipm10": "6",
"temp_f": "69.99"
},
"basement": {
"pm25": "4.0",
"pm10": "9.7",
"aqipm25": "17",
"aqipm10": "8"
},
"outdoor": {
"pm25": "11.96",
"pm10": "13.56",
"LastSeen": 1631478276,
"humidity": "39",
"temp_f": "72.57",
"pressure": "1014.62",
"aqipm25": "50",
"aqipm10": "12"
}
}
Output post
or info
INFO:root:Command executed : ssh pi@203.0.113.20 monitor_air_quality : {'dt': '2021-09-12T13:28:27.219094', 'upstairs': {'pm25': '3.7', 'pm10': '6.4', 'aqipm25': '15', 'aqipm10': '6'}}
INFO:root:Local air quality data fetched {'pm25': '4.0', 'pm10': '8.6', 'aqipm25': '17', 'aqipm10': '7'}
INFO:root:Notion temperature data fetched : 69.99
INFO:root:Purpleair data fetched {'pm25': '11.57', 'pm10': '12.63', 'LastSeen': 1631478516, 'humidity': '39', 'temp_f': '73.57', 'pressure': '1014.6', 'aqipm25': '48', 'aqipm10': '11'}
INFO:root:Metric upstairs pm25 3.7 continues to not exceed 12. No transition occurred
INFO:root:It continues to be warmer outside 73.57 than inside 69.99. No transition occurred
Notes
I ended up using the py-sds011
library instead of the sds011
library
or just interacting with the serial device directly as it seemed to work
the best for me.
I also chose to use "query mode" instead of "active mode" for the sds011 sensor, though I'm not entirely sure I understand the difference.
Sampling for 30 seconds every 5 minutes would use up 800 of the 1000 hour life of the sensor in 1 year. I will likely drop this down to 30 seconds every 10 minutes or more.
I read somewhere that the manufacturer recommends a 30 second sample but don't know where that's written.
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
Built Distribution
File details
Details for the file monitor_air_quality-2.0.2.tar.gz
.
File metadata
- Download URL: monitor_air_quality-2.0.2.tar.gz
- Upload date:
- Size: 21.3 kB
- Tags: Source
- Uploaded using Trusted Publishing? No
- Uploaded via: twine/3.4.2 importlib_metadata/4.8.1 pkginfo/1.7.1 requests/2.26.0 requests-toolbelt/0.9.1 tqdm/4.62.3 CPython/3.7.12
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 86177ddd58d9a1ce47c1c184465ffe297064c315098cdb595ee78591b49eabaa |
|
MD5 | d8768c9924c91ef8e793782bd6c9a798 |
|
BLAKE2b-256 | 8a41ca4b4d943d7598c9fc11cbe6bd6eed79418c0fb4d2276dfa67122b247dcd |
File details
Details for the file monitor_air_quality-2.0.2-py3-none-any.whl
.
File metadata
- Download URL: monitor_air_quality-2.0.2-py3-none-any.whl
- Upload date:
- Size: 21.1 kB
- Tags: Python 3
- Uploaded using Trusted Publishing? No
- Uploaded via: twine/3.4.2 importlib_metadata/4.8.1 pkginfo/1.7.1 requests/2.26.0 requests-toolbelt/0.9.1 tqdm/4.62.3 CPython/3.7.12
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | de0ed7e836adb248594859d62baae044791f36de066e105e863d04c9ed910bd8 |
|
MD5 | a18a8573d376dd5f23eb083ed67515ee |
|
BLAKE2b-256 | a37f790bedea9d3d218b0d17e7713c011b30d78e3195e9c36bf195f3aaaec56b |