ST9010A Hipot Tester Driver
Project description
ST90101A Hipot Tester
cd st9010a-hipot-tester
git clone git@gitlab.com:pass-testing-solutions/st9010a-hipot-tester.git
git remote add origin https://gitlab.com/pass-testing-solutions/st9010a-hipot-tester.git
git pull origin main
git checkout -b <your-new-branch> # Please follow the branch naming convention as mentioned in the coding guidelines
Description
This is an interface library for the ST90101A Hipot Tester.
Installation
pip install pts-st9010a-hipot-tester
Driver Functions
pts_st9010a_hipot_tester.st9010a_hipot_tester.ST9010AHipotTester(connection_string)
Base class for the ST90101A Hipot Tester
open_connection()
Opens a serial connection with the ST90101A Hipot Tester
close_connection()
Closes a serial connection with the ST90101A Hipot Tester
id_number()
This function returns the ID number
Returns: str : IDN
fetch_results()
Fetches all the measurement results
set_display(page)
Set the instrument's display page
Parameters
page – One of the instrument’s display pages
’Meas’: Test Display or Measurement page,
’Mset’: Test Setup or Measurement Setting page,
’Sysm’: System -> Environment page,
’Iost’: System -> IO page
Returns: None
check_display()
Queries the instrument's display page
Returns: Display page
start_test()
Starts Test on the ST9010A Hipot Tester
stop_test()
Stops Test on the ST9010A Hipot Tester
set_voltage(step, test_mode, voltage)
This function sets the voltage for the ACW/DCW/IR test
Parameters
step – The step for which the voltage is added in the range 1-20
test_mode – modes being AC/DC/IR
voltage – The voltage to be set in Volts in range
AC TEST: 50-5000 volts
DC TEST: 50-6000 volts
IR TEST: 50-1000 volts
Returns: No return
check_voltage(step, test_mode)
This function queries the voltage for the ACW test
Parameters
step – The step for which the voltage is added in the range 1-20
test_mode – modes being AC/DC/IR
Returns: float : Voltage in volts
set_current_limits(step, test_mode, low_limit, upper_limit)
This functions sets the lower and upper current limits for ACW/DCW/IR test
Parameters
test_mode – modes being AC/DC/IR
step – The step for which the current is added in the range 1-20
low_limit – Lower current limit in range
AC TEST: 0.001 mA
DC TEST: 0.001 mA
IR TEST: 0.001 mA
upper_limit – Upper current limit in range
AC TEST: 20.000 mA
DC TEST: 20.000 mA
IR TEST: 20.000 mA
Returns: No return
check_current_limits(step, test_mode)
This function checks the lower and upper current limits set by the user/by default
Parameters
test_mode – modes being AC/DC/IR
step – The step for which the current is added in the range 1-20
Returns: tuple : Lower and upper current limits in Amps respectively
set_test_time(step, test_mode, test_time)
This functions sets the TEST time for ACW/DCW/IR tests
Parameters
step – The step for which the test time is set in the range 1-20
test_mode – modes being AC/DC/IR
test_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test
Returns: No return
check_test_time(step, test_mode)
This functions queries the TEST time for the ACW/DCW/IR test
Parameters
step – The step for which the test time is set in the range 1-20
test_mode – modes being AC/DC/IR
Returns: float : Test time in seconds
set_rise_time(step, test_mode, rise_time)
This functions sets the RISE time for ACW/DCW/IR tests
Parameters
step – The step for which the rise time is set in the range 1-20
test_mode – modes being AC/DC/IR
rise_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test
Returns: No return
check_rise_time(step, test_mode)
This functions queries the RISE time for the ACW/DCW/IR test
Parameters
step – The step for which the rise time is set in the range 1-20
test_mode – modes being AC/DC/IR
Returns: float : Rise time in seconds
set_fall_time(step, test_mode, fall_time)
This functions sets the FALL time for ACW/DCW/IR tests
Parameters
step – The step for which the fall time is set in the range 1-20
test_mode – modes being AC/DC/IR
fall_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test
Returns: No return
check_fall_time(step, test_mode)
This functions queries the FALL time for the ACW/DCW/IR test
Parameters
step – The step for which the fall time is set in the range 1-20
test_mode – modes being AC/DC/IR
Returns: float : Fall time in seconds
set_channel(step, test_mode, channel, chan_value)
This functions sets HIGH/LOW/OPEN for the scanner channel for ACW/DCW/IR test.
Parameters
step – The step in the range 1-20
test_mode – modes being AC/DC/IR
channel – Channel in the range of 1-4
chan_value – Channel values being HIGH/LOW/OPEN
Returns: No return
get_channel(step, test_mode, channel)
This functions queries the set channel value for ACW/DCW/IR test.
Parameters
channel – Channel value set in the range for 1-4
step – The step in the range 1-20
test_mode – modes being AC/DC/IR
Returns: str : Channel value in (HIGH/LOW/OPEN)
set_ac_freq(step, freq)
This functions sets the test frequency for ACW test.
Parameters
step – The step for which the AC freq is set in the range 1-20
freq – Set value 50/60 Hz in ACW test
Returns: No return
get_ac_freq(step)
This functions queries the test frequency for ACW test.
Parameters
step – The step for which the AC freq is set in the range 1-20
Returns: float : Value for the test FREQUENCY
set_multiple_channels(step, test_mode, channel, chan_switch)
This functions sets ON/OFF (1/0) about multiple channels for ACW/DCW/IR test.
Parameters
step – The step for which channel is switched in the range 1-20
test_mode – modes being AC/DC/IR
channel – Channel in the range of 1-4
chan_switch – Channel switch being ON/OFF (1/0)
Returns: No return
check_multiple_channels(step, test_mode, channel)
This functions queries the multiple channels for ACW/DCW/IR test.
Parameters
channel – Channel value set in the range for 1-4
step – The step for which channel is switched in the range 1-20
test_mode – modes being AC/DC/IR
Returns: str : Channel switch being ON/OFF (1/0)
Authors and acknowledgment
Author: Shuparna Deb (@shuparnadeb_pts)
License
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
Built Distribution
Hashes for pts_st9010a_hipot_tester-0.0.2.tar.gz
Algorithm | Hash digest | |
---|---|---|
SHA256 | 37c177c39ec4bce0c6e061034fbd5ffe1897f26658695cd3a20144c8d507bcac |
|
MD5 | c73ba8d5c30679479d008176869b86a9 |
|
BLAKE2b-256 | 8ec1115da24d4691166561114a88f02d5e4b19b2261d712df6bbe3c1bf31abb6 |
Hashes for pts_st9010a_hipot_tester-0.0.2-py3-none-any.whl
Algorithm | Hash digest | |
---|---|---|
SHA256 | 8b79c9b6ef029eb02daadb12c58819b6c75bdc9593fd00698d5f8e1f2b60f87f |
|
MD5 | c9ee49d3188ea6c3bebd8055bf887e08 |
|
BLAKE2b-256 | 9a27e1c0d8cf726f611d06f7b29dfea06833cc3ac05b9eebfb1279fa5e79dc05 |