Skip to main content

ST9010A Hipot Tester Driver

Project description

ST90101A Hipot Tester

cd st9010a-hipot-tester
git clone git@gitlab.com:pass-testing-solutions/st9010a-hipot-tester.git
git remote add origin https://gitlab.com/pass-testing-solutions/st9010a-hipot-tester.git
git pull origin main
git checkout -b <your-new-branch>  # Please follow the branch naming convention as mentioned in the coding guidelines

Description

This is an interface library for the ST90101A Hipot Tester.

Installation

pip install pts-st9010a-hipot-tester

Driver Functions

pts_st9010a_hipot_tester.st9010a_hipot_tester.ST9010AHipotTester(connection_string)

Base class for the ST90101A Hipot Tester

open_connection()

Opens a serial connection with the ST90101A Hipot Tester

close_connection()

Closes a serial connection with the ST90101A Hipot Tester

id_number()

This function returns the ID number

Returns: str : IDN

fetch_results()

Fetches all the measurement results

set_display(page)

Set the instrument's display page

Parameters

page – One of the instrument’s display pages

’Meas’: Test Display or Measurement page,

’Mset’: Test Setup or Measurement Setting page,

’Sysm’: System -> Environment page,

’Iost’: System -> IO page

Returns: None

check_display()

Queries the instrument's display page

Returns: Display page

start_test()

Starts Test on the ST9010A Hipot Tester

stop_test()

Stops Test on the ST9010A Hipot Tester

set_voltage(step, test_mode, voltage)

This function sets the voltage for the ACW/DCW/IR test

Parameters

step – The step for which the voltage is added in the range 1-20

test_mode – modes being AC/DC/IR

voltage – The voltage to be set in Volts in range

AC TEST: 50-5000 volts

DC TEST: 50-6000 volts

IR TEST: 50-1000 volts

Returns: No return

check_voltage(step, test_mode)

This function queries the voltage for the ACW test

Parameters

step – The step for which the voltage is added in the range 1-20

test_mode – modes being AC/DC/IR

Returns: float : Voltage in volts

set_current_limits(step, test_mode, low_limit, upper_limit)

This functions sets the lower and upper current limits for ACW/DCW/IR test

Parameters

test_mode – modes being AC/DC/IR

step – The step for which the current is added in the range 1-20

low_limit – Lower current limit in range

AC TEST: 0.001 mA

DC TEST: 0.001 mA

IR TEST: 0.001 mA

upper_limit – Upper current limit in range

AC TEST: 20.000 mA

DC TEST: 20.000 mA

IR TEST: 20.000 mA

Returns: No return

check_current_limits(step, test_mode)

This function checks the lower and upper current limits set by the user/by default

Parameters

test_mode – modes being AC/DC/IR

step – The step for which the current is added in the range 1-20

Returns: tuple : Lower and upper current limits in Amps respectively

set_test_time(step, test_mode, test_time)

This functions sets the TEST time for ACW/DCW/IR tests

Parameters

step – The step for which the test time is set in the range 1-20

test_mode – modes being AC/DC/IR

test_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test

Returns: No return

check_test_time(step, test_mode)

This functions queries the TEST time for the ACW/DCW/IR test

Parameters

step – The step for which the test time is set in the range 1-20

test_mode – modes being AC/DC/IR

Returns: float : Test time in seconds

set_rise_time(step, test_mode, rise_time)

This functions sets the RISE time for ACW/DCW/IR tests

Parameters

step – The step for which the rise time is set in the range 1-20

test_mode – modes being AC/DC/IR

rise_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test

Returns: No return

check_rise_time(step, test_mode)

This functions queries the RISE time for the ACW/DCW/IR test

Parameters

step – The step for which the rise time is set in the range 1-20

test_mode – modes being AC/DC/IR

Returns: float : Rise time in seconds

set_fall_time(step, test_mode, fall_time)

This functions sets the FALL time for ACW/DCW/IR tests

Parameters

step – The step for which the fall time is set in the range 1-20

test_mode – modes being AC/DC/IR

fall_time – Time in range 0~999.9 (0 is OFF) seconds for ACW/DCW/IR test

Returns: No return

check_fall_time(step, test_mode)

This functions queries the FALL time for the ACW/DCW/IR test

Parameters

step – The step for which the fall time is set in the range 1-20

test_mode – modes being AC/DC/IR

Returns: float : Fall time in seconds

set_channel(step, test_mode, channel, chan_value)

This functions sets HIGH/LOW/OPEN for the scanner channel for ACW/DCW/IR test.

Parameters

step – The step in the range 1-20

test_mode – modes being AC/DC/IR

channel – Channel in the range of 1-4

chan_value – Channel values being HIGH/LOW/OPEN

Returns: No return

get_channel(step, test_mode, channel)

This functions queries the set channel value for ACW/DCW/IR test.

Parameters

channel – Channel value set in the range for 1-4

step – The step in the range 1-20

test_mode – modes being AC/DC/IR

Returns: str : Channel value in (HIGH/LOW/OPEN)

set_ac_freq(step, freq)

This functions sets the test frequency for ACW test.

Parameters

step – The step for which the AC freq is set in the range 1-20

freq – Set value 50/60 Hz in ACW test

Returns: No return

get_ac_freq(step)

This functions queries the test frequency for ACW test.

Parameters

step – The step for which the AC freq is set in the range 1-20

Returns: float : Value for the test FREQUENCY

set_multiple_channels(step, test_mode, channel, chan_switch)

This functions sets ON/OFF (1/0) about multiple channels for ACW/DCW/IR test.

Parameters

step – The step for which channel is switched in the range 1-20

test_mode – modes being AC/DC/IR

channel – Channel in the range of 1-4

chan_switch – Channel switch being ON/OFF (1/0)

Returns: No return

check_multiple_channels(step, test_mode, channel)

This functions queries the multiple channels for ACW/DCW/IR test.

Parameters

channel – Channel value set in the range for 1-4

step – The step for which channel is switched in the range 1-20

test_mode – modes being AC/DC/IR

Returns: str : Channel switch being ON/OFF (1/0)

Authors and acknowledgment

Author: Shuparna Deb (@shuparnadeb_pts)

License

License: MIT

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

pts_st9010a_hipot_tester-0.0.2.tar.gz (5.7 kB view hashes)

Uploaded Source

Built Distribution

pts_st9010a_hipot_tester-0.0.2-py3-none-any.whl (6.9 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page