Skip to main content

Read values from MyUpway cloud service

Project description

pyupway

Simple utility to read values from MyUpway cloud service.

Supported devices

Currently pyupway has been tested on following units

  • MCU40
  • Jäspi Basic Split 12 kW

Installation

Install using pip

pip install pyupway

Usage

Basic usage is to import MyUpway and MyUpwayConfig from pyupway.

Initialize MyUpwayConfig with proper settings and use it to initialize MyUpway itself. You can obtain heat pump id from the MyUpway UI URL "https://www.myupway.com/System//Status/Overview"

from pyupway import MyUpway, MyUpwayConfig, Variable

config = MyUpwayConfig(<username>, <password>, 123456)

myupway = MyUpway(config)

print(myupway.get_current_values([Variable.HIGH_PRESSURE_SENSOR]))
print(myupway.get_history_values(Variable.EXTERNAL_FLOW_TEMP, startDate=datetime(2023,6,1,0,0,0), stopDate=datetime(2023,6,4,0,0,0)))

Data classes

Results are returned in defined dataclasses

VariableValue

from pyupway import VariableValue
Field Type
Id int
Name str
Enumerator Variable
Value int | float | str | bool | None
Unit str | None

VariableHistoryValue

from pyupway import VariableHistoryValue
Field Type
Value int | float | str | bool | None
Unit str | None
Date datetime

Variables available

Enum Name Variable ID History Data
AVG_OUTDOOR_TEMP 40067 yes
INDOOR_UNIT_OUTDOOR_TEMP 40004 yes
CURRENT_BE1 40083 yes
CURRENT_BE2 40081 yes
CURRENT_BE3 40079 yes
DEGREE_MINUTES 43005 yes
EXTERNAL_ADJUSTMENT 43161 no
FLOOR_DRYING_FUNCTION 47276 no
CALCULATED_FLOW_TEMP 43009 yes
EXTERNAL_FLOW_TEMP 40071 yes
EXTERNAL_RETURN_TEMP 40152 yes
ROOM_TEMPERATURE 40033 yes
ADDITION_BLOCKED 10033 no
ADDITION_MAX_STEP 47613 no
ADDITION_STATUS 43091 yes
ADDITION_FUSE_SIZE 47214 no
AUX1 47411 no
AUX2 47410 no
AUX3 47409 no
AUX4 47408 no
AUX5 47407 no
AUX6 48366 no
X7 47412 no
COUNTRY 48745 no
DEFROSTING 44703 no
CHARGE_PUMP_SPEED 44396 yes
OUTDOOR_UNIT_OUTDOOR_TEMP 44362 yes
COMPRESSOR_BLOCKED 10014 no
COMPRESSOR_STARTS 44069 yes
COMPRESSOR_PROTECTION_MODE 44702 no
CONDENSER_OUT 44058 yes
EVAPORATOR 44363 yes
HOT_GAS 44059 yes
LIQUID_LINE 44060 yes
RETURN_TEMP 44055 yes
SUCTION_GAS 44061 yes
HIGH_PRESSURE_SENSOR 44699 yes
LOW_PRESSURE_SENSOR 44700 yes
COMPRESSOR_OPERATING_TIME 44071 yes
COMPRESSOR_OPERATING_TIME_HOT_WATER 44073 yes
COMPRESSOR_RUN_TIME_COOLING 40737 yes
CURRENT_COMPRESSOR_FREQUENCY 44701 yes
REQUESTED_COMPRESSOR_FREQUENCY 40782 no
VERSION 44014 no

Functions

get_current_values

Returns the current values for selected variables. Provide variables as a list of Variable enums.

Example

myupway.get_current_values([Variable.HIGH_PRESSURE_SENSOR, Variable.AVG_OUTDOOR_TEMP])

get_history_values

Returns the historical values for specified timerange.

Example

myupway.get_history_values(Variable.EXTERNAL_FLOW_TEMP, startDate=datetime(2023,6,1,0,0,0), stopDate=datetime(2023,6,4,0,0,0))

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.