Skip to main content

Voyis Recon LS python driver

Project description

PyVoyis

Python library for controlling the Voyis Recon LS camera, strobes and laser system.

Installation

Use pip to install the library:

pip install pyvoyis

Usage

The library can be used as standalone or as a module. The following examples show how to use it as a module.

from pyvoyis import VoyisAPI
api = VoyisAPI(args.ip, args.port)

# If you want the acquision to start straight away, you can request it
api.request_acquisition()

api.run()  # This will block until the acquisition is finished and the API disconnected

# From a different thread, you can request a stop
api.request_stop()

or you can call the API from the command line:

pyvoyis --ip 192.168.1.10 --port 4875

and it will start the acquisition and block until it's stopped with Ctrl+C.

Known issues

Time source does not work

I've set up a ZDA broadcast on port 4010. The scanner is connected to the same network and can ping the computer (192.168.1.71). The scanner is set to use the ZDA broadcast as its time source.

Message sent:

{
    "message": "SetTimeTagSourceCmd",
    "payload": {
        "network": 2,
        "connection": "192.168.1.71:4010"
    }
}

Received:

{
    "message": "AckRsp",
    "payload": {
        "accepted": false,
        "command_id": 263,
        "nack_error_code": 3,
        "nack_error_string": "Bad Parameter.",
        "api_version": "6.0.5.96dec0cc"
    }
}

Nav source does not work

We've set up a PSONNAV broadcast on port 4003. The scanner is connected to the same network and can ping the computer (192.168.179.10). The scanner is set to use the PSONNAV broadcast as its nav source.

Message sent:

{
    "message": "SetNavDataSourceCmd",
    "payload": {
        "network": 3,
        "protocol": 1,
        "connection": "192.168.179.10:4003"
    }
}

The scanner does not accept the nav source. The following error is returned:

{
    "message": "AckRsp",
    "payload": {
        "accepted": false,
        "command_id": 35,
        "nack_error_code": 3,
        "nack_error_string": "Bad Parameter.",
        "api_version": "6.0.5.96dec0cc"
    }
}

Also tried with port only, and with either TCP_CLIENT or TCP_SERVER. Same result.

Laser safety

The following keys return true regardless of the dongles being connected, armed or disarmed. How can we verify what is connected or not?

SCANNER_STATUS_LASER_DONGLE_AT_CH
SCANNER_STATUS_LASER_INHIBIT_ENABLED
SCANNER_STATUS_LASER_SAFETY_DISABLED

Can the laser be disabled via software?

Answer unkown.

What is the difference between local_value and remote_value in scanner_parameters?

Answer unkown.

Temperature and humidity sensors reliable?

Only SCANNER_STATUS_INTERNAL_TEMP_CH works. Other report either 0 or 255.

What are the max frequencies for cameras?

If the raw laser images are saved to disk, its frequency is currently limited to 1 Hz.

Can the frequency of laser images be larger than 1hz if there's enough time for stills? Where's the compromise?