Ricks-Lab UPS Utilities
Project description
rickslab-ups-utils
A set of utilities to monitor and react to the status of a supported UPS
Installation
Debian Package Installation
First, remove any previous PyPI installation and exit that terminal:
pip uninstall rickslab-ups-utils
exit
Next, add the rickslab-ups-utils repository:
wget -q -O - https://debian.rickslab.com/PUBLIC.KEY | sudo apt-key add -
echo 'deb [arch=amd64] https://debian.rickslab.com/ups-utils/ stable main' | sudo tee /etc/apt/sources.list.d/rickslab-ups-utils.list
sudo apt update
Then install the package with apt:
sudo apt install rickslab-ups-utils
PyPI Installation
Install the latest package from PyPI with the following commands:
pip3 uninstall rickslab-ups-utils
pip3 install rickslab-ups-utils
The uninstall is required to make sure all modules are updated. If you still get an old version, then specify not to use cached files:
pip3 install --no-cache-dir rickslab-ups-utils
Getting Started
Application configuration parameters can be specified in the ups-utils.ini
file. A
template files is provided: ups-utils.ini.template
. You can verify the values of
the configuration settings by executing
ups-daemon --list_params
Also, a UPS list must be specified in the config.json
file using config.json.template
as a
template. This file contains details about each UPS that make snmp communication possible. The
utility requires snmp v2c in order to communicate with the network accessible UPSs. As a result,
you must configure your target Network attached UPS devices to use SNMPv2 with a known Private
Community String.
The ups-utils rely on the command snmpget which is part of the snmp package that must be installed:
sudo apt install snmp
ups-daemon
With no options specified, the utility will give the current status of the UPS configured with daemon = true in the config.json file. With the --daemon option, ups-daemon will continuously check the status of the UPS. When it detects that the UPS is sourcing powering from the battery, it will check the amount of time it has been running on battery and run the specified suspend script when the specified threshold is exceeded. It will execute the specified resume script when it detects power has resumed. When the utility detects a Battery Low event from the UPS or that time remaining for battery or the battery charge is below specified thresholds, then the shutdown script will be executed. If ups-deamon detects a return to line power has occurred before the shutdown has completed, it will execute the cancel shutdown script. With the --list_commands option, the utility will list all available SNMP commands for the configured UPS. With the --list_params option, the daemon configuration parameters will be listed. The --logfile filename option is used to specify a logfile, but is not implemented at this time. The threshold and script definitions must be made in the config.py file using config.py.template as a template.
ups-ls
This utility displays most relevant parameters for installed and compatible UPSs listed in the config.json file. By default, all available parameters are displayed. The --input and --output options can be used to get relevant UPS input and output parameters.
ups-monitor
A utility to give the current state of all compatible UPSs. The default behavior is to continuously update a text based table in the current window until Ctrl-C is pressed. With the --gui option, a table of relevant parameters will be updated in a Gtk window. You can specify the delay between updates with the --sleep N option where N is an integer > 10 that specifies the number of seconds to sleep between updates. The --log option is used to write all monitor data to a psv log file. When writing to a log file, the utility will indicate this in red at the top of the window with a message that includes the log file name. The --status option will output a table of the current status. The --long option will include additional informational parameters. By default, unresponsive UPSs will not be displayed, but the --show_unresponsive can be used to force their display.
New in this Beta Release - v0.11.0
- Initial Beta Release - Please feedback your question/issues in the project's issues. Thanks!
Under Development
The utility currently supports:
- APC UPS with AP9630 NMC
- EATON UPS with PowerWalker NMC
It monitors the specified UPS using snmp v2c. I have not implemented the ability to listen to snmp traps yet, as I still have some research to do. If you have different UPS and would like to extend the dictionary in this code to support it, feel free to make a pull request.
Reference Material
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distributions
Built Distribution
File details
Details for the file rickslab_ups_utils-1.0.0-py3-none-any.whl
.
File metadata
- Download URL: rickslab_ups_utils-1.0.0-py3-none-any.whl
- Upload date:
- Size: 76.9 kB
- Tags: Python 3
- Uploaded using Trusted Publishing? No
- Uploaded via: twine/3.2.0 pkginfo/1.6.0 requests/2.24.0 setuptools/39.0.1 requests-toolbelt/0.9.1 tqdm/4.50.2 CPython/3.7.5
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 1d1fb280145a4ca264849b401cedbbff3d9aaf81a9b4c30724fb9f58df96e15d |
|
MD5 | 7da1ab577ece99dfb43b6f516c58169b |
|
BLAKE2b-256 | be27931eb2387eb518e4b7da2d5bdb5b776c340c50e4d643ee29cabb9adf4d77 |