Skip to main content

Robotframework connector for Zebrunner reporting

Project description

python-agent-robot

The official Zebrunner Robotframework agent provides the reporting functionality. It can automatically track Selenium sessions and send the info about session details to Zebrunner backend. It can be easily integrated into a project by just installing the library and adding the configuration file.

Including reporting into your project is easy - just install the agent and provide minimal valid configuration for reporting.

Installation

pip install robotframework-zebrunner

Configuration

After the installation, reporting is disabled by default. It won't send any data to the Zebrunner service without a valid configuration.

It is currently possible to provide the configuration via:

  1. Environment variables
  2. YAML file

pyproject.toml, command arguments are in plans for future releases.

Environment variables

The following configuration parameters are recognized by the agent:

  • REPORTING_ENABLED - enables or disables reporting. The default value is true.
  • REPORTING_SERVER_HOSTNAME - mandatory if reporting is enabled. It is Zebrunner server hostname. It can be obtained in Zebrunner on the 'Account & profile' page under the 'Service URL' section;
  • REPORTING_SERVER_ACCESS_TOKEN - mandatory if reporting is enabled. Access token must be used to perform API calls. It can be obtained in Zebrunner on the 'Account & profile' page under the 'Token' section;
  • REPORTING_PROJECT_KEY - optional value. It is the project that the test run belongs to. The default value is DEF. You can manage projects in Zebrunner in the appropriate section;
  • REPORTING_RUN_DISPLAY_NAME - optional value. It is the display name of the test run. The default value is Default Suite;
  • REPORTING_RUN_BUILD - optional value. It is the build number that is associated with the test run. It can depict either the test build number or the application build number;
  • REPORTING_RUN_ENVIRONMENT - optional value. It is the environment where the tests will run;
  • REPORTING_SEND_LOGS - Sends test logs to Zebrunner. Default: true;
  • REPORTING_NOTIFICATION_NOTIFY_ON_EACH_FAILURE - optional value. Specifies whether Zebrunner should send notification to Slack/Teams on each test failure. The notifications will be sent even if the suite is still running. The default value is false;
  • REPORTING_NOTIFICATION_SLACK_CHANNELS - optional value. The list of comma-separated Slack channels to send notifications to. Notification will be sent only if Slack integration is properly configured in Zebrunner with valid credentials for the project the tests are reported to. Zebrunner can send two type of notifications: on each test failure (if appropriate property is enabled) and on suite finish;
  • REPORTING_NOTIFICATION_MS_TEAMS_CHANNELS - optional value. The list of comma-separated Microsoft Teams channels to send notifications to. Notification will be sent only if Teams integration is configured in Zebrunner project with valid webhooks for the channels. Zebrunner can send two type of notifications: on each test failure (if appropriate property is enabled) and on suite finish;
  • REPORTING_NOTIFICATION_EMAILS - optional value. The list of comma-separated emails to send notifications to. This type of notification does not require further configuration on Zebrunner side. Unlike other notification mechanisms, Zebrunner can send emails only on suite finish;
  • REPORTING_RUN_TREAT_SKIPS_AS_FAILURES - optional value. If value is false all test-runs with skipped & passed tests would be marked as passed.

Agent also recognizes .env file in the resources root folder.

Yaml file

Agent recognizes agent.yaml or agent.yml file in the resources root folder. It is currently not possible to configure an alternative file location.

Below is a sample configuration file:

reporting:
  enabled: true
  project-key: DEF
  send-logs: true
  server:
    hostname: localhost:8080
    access-token: <token>
  notification:
    notify-on-each-failure: true
    slack-channels: automation, dev-team
    ms-teams-channels: automation, qa-team
    emails: example@example.com
  run:
    treat-skips-as-failures: false
    display-name: Nightly Regression Suite
    build: 1.12.1.96-SNAPSHOT
    environment: TEST-1
  • reporting.enabled - enables or disables reporting. The default value is true;
  • reporting.server.hostname - mandatory if reporting is enabled. Zebrunner server hostname. Can be obtained in Zebrunner on the 'Account & profile' page under the 'Service URL' section;
  • reporting.server.access-token - mandatory if reporting is enabled. Access token must be used to perform API calls. Can be obtained in Zebrunner on the 'Account & profile' page under the 'Token' section;
  • reporting.project-key - optional value. The project that the test run belongs to. The default value is DEF. You can manage projects in Zebrunner in the appropriate section;
  • reporting.send-logs - Sends test logs to Zebrunner. Default: true
  • reporting.run.display-name - optional value. The display name of the test run. The default value is Default Suite;
  • reporting.run.build - optional value. The build number that is associated with the test run. It can depict either the test build number or the application build number;
  • reporting.run.environment - optional value. The environment in which the tests will run.
  • reporting.notification.notify-on-each-failure - optional value. Specifies whether Zebrunner should send notification to Slack/Teams on each test failure. The notifications will be sent even if the suite is still running. The default value is false;
  • reporting.notification.slack-channels - optional value. The list of comma-separated Slack channels to send notifications to. Notification will be sent only if Slack integration is properly configured in Zebrunner with valid credentials for the project the tests are reported to. Zebrunner can send two type of notifications: on each test failure (if appropriate property is enabled) and on suite finish;
  • reporting.notification.ms-teams-channels - optional value. The list of comma-separated Microsoft Teams channels to send notifications to. Notification will be sent only if Teams integration is configured in Zebrunner project with valid webhooks for the channels. Zebrunner can send two type of notifications: on each test failure (if appropriate property is enabled) and on suite finish;
  • reporting.notification.emails - optional value. The list of comma-separated emails to send notifications to. This type of notification does not require further configuration on Zebrunner side. Unlike other notification mechanisms, Zebrunner can send emails only on suite finish;
  • reporting.run.treat_skips_as_failures - optional value. If value is false all test-runs with skipped & passed tests would be marked as passed.

If the required configurations are not provided, there is a warning displayed in logs with the problem description and the names of options which need to be specified. Parameter names are case-insensitive and can be written in upper and lower registers.

Activate listener

There is two options for activation of Zebrunner listener.

Command line argument:

robot --listener robotframework_zebrunner.ZebrunnerListener

Import Zebrunner library into your project:

Library  robotframework_zebrunner.ZebrunnerLib

Collecting captured screenshot

Sometimes it may be useful to have the ability to track captured screenshots in scope of Zebrunner Reporting. The agent comes with the API allowing you to send your screenshots to Zebrunner, so that they could be attached to the test.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

With screenshot
    ...
    Create File  ${OUTPUTDIR}/selenium-screenshot-1.png
    Capture Page Screenshot	${OUTPUTDIR}/selenium-screenshot-1.png
    Attach Test Screenshot  ${OUTPUTDIR}/selenium-screenshot-1.png
    ...

Additional reporting capabilities

Tracking test maintainer

You may want to add transparency to the process of automation maintenance by having an engineer responsible for evolution of specific tests or test classes. Zebrunner comes with a concept of a maintainer - a person that can be assigned to maintain tests. In order to keep track of those, the agent comes with the maintainer tag.

See a sample test bellow:

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

With maintainer
    [Tags]  maintainer=<maintainer_name>
    Should Be True    5 + 5 == 10

Attaching labels

In some cases, it may be useful to attach some meta information related to a test. The agent comes with a concept of a label. Label is a key-value pair associated with a test. The key and value are represented by a str. Labels can be attached to tests and test runs.

There is a tag that can be used to attach labels to a test. There is also an API to attach labels during test or execution. The agent has functions that can be used to attach labels.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

With labels
    [Tags]  labels: some_label=123, other_label=234

    Attach Test Label   some_test_label  value
    Attach Test Run Label  some_test_run_label  value
    Should Be True    5 + 5 == 10

The test from the sample above attaches 3 test-level labels.

Reverting test registration

In some cases it might be handy not to register test execution in Zebrunner. This may be caused by very special circumstances of test environment or execution conditions.

Zebrunner agent comes with a convenient method revert_registration() from CurrentTest class for reverting test registration at runtime. The following code snippet shows a case where test is not reported on Monday.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

Revert test
     Current Test Revert Registration
     Should Be True    5 + 5 == 10

Overriding run attributes

This section contains information on agent APIs allowing to manipulate test run attributes during runtime.

Setting build at runtime

All the configuration mechanisms listed above provide possibility to declaratively set test run build. But there might be cases when actual build becomes available only at runtime.

For such cases Zebrunner agent has a special method that can be used at any moment of the suite execution:

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Current Test Run Set Build  0.0.1

Setting locale

If you want to get full reporting experience and collect as much information in Zebrunner as its possible, you may want to report the test run locale.

For this, Zebrunner agent has a special method that can be used at any moment of the suite execution:

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Current Test Run Set Locale  EN

Overriding platform

A test run in Zebrunner may have platform associated with the run. If there is at least one initiated Remote driver session within the test run, then its platform will be displayed as a platform of the whole test run. Even if subsequent Remote drivers are initiated on another platform, the very first one will be displayed as the run platform.

In some cases you may want to override the platform of the first Remote driver session. Another problem is that it is not possible to specify API as a platform.

Zebrunner provides two special methods to solve both of these problems: Current Test Run Set Platform and Current Test Run Set Platform Version. In the example below, the hook sets the API as a platform associated with the current test run.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Current Test Run Set Platform  API

Collecting additional artifacts

In case your tests or an entire test run produce some artifacts, it may be useful to track them in Zebrunner. The agent comes with a few convenient methods for uploading artifacts in Zebrunner and linking them to the currently running test or test run. Artifacts and artifact references can be attached using functions. Together with an artifact or artifact reference, you must provide the display name. For the file, this name must contain the file extension that reflects the actual content of the file. If the file extension does not match the file content, this file will not be saved in Zebrunner. Artifact reference can have an arbitrary name.

Attaching artifact to test

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

With artifact
    Attach Test Artifact  requirements.txt
    ...

Attaching artifact reference to test

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

With artifact reference
    Attach Test Artifact Reference  google  https://google.com
    ...

Attaching artifact to test run

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

Attach Test Run Artifact  requirements.txt

Attaching artifact reference to test run

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib

Attach Test Run Artifact Reference  google  https://google.com

Artifact uploading process is performed in the foreground now, so it will block the execution thread while sending. The background uploading will be available in upcoming releases.

Syncing test executions with external TCM systems

Zebrunner provides an ability to upload test results to external test case management systems (TCMs) on test run finish. For some TCMs it is possible to upload results in real-time during the test run execution.

This functionality is currently supported for TestRail, Xray, Zephyr Squad and Zephyr Scale.

TestRail

For successful upload of test run results in TestRail, two steps must be performed:

  1. Integration with TestRail is configured and enabled for Zebrunner project
  2. Configuration is performed on the tests side

Configuration

Zebrunner agent has a special Test Rail keywords:

Test Rail Set Suite Id <id> : Mandatory. The method sets TestRail suite id for current test run. This method must be invoked before all tests.

Test Rail Set Case Id <id> or test_rail_case_id=<id> tag : Mandatory. Using these mechanisms you can set TestRail's case associated with specific automated test. It is highly recommended using the test_rail_case_id tag instead of keyword. Use the keyword only for special cases

Test Rail Disable Sync : Optional. Disables result upload. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

Test Rail Include All Test Cases In New Run : Optional. Includes all cases from suite into newly created run in TestRail. Same as #set_suite_id(str), this method must be invoked before all tests

Test Rail Enable Real Time Sync : Optional. Enables real-time results upload. In this mode, result of test execution will be uploaded immediately after test finish. This method also automatically invokes Test Rail Include All Test Cases In New Run. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

Test Rail Set Run Id <id> : Optional. Adds result into existing TestRail run. If not provided, test run is treated as new. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

Test Rail Set Run Name <name> : Optional. Sets custom name for new TestRail run. By default, Zebrunner test run name is used. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

Test Rail Set Milestone <milestone> : Optional. Adds result in TestRail milestone with the given name. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

Test Rail Set Assignee <assignee> : Optional. Sets TestRail run assignee. Same as Test Rail Set Suite Id, this keyword must be invoked before all tests

By default, a new run containing only cases assigned to the tests will be created in TestRail on test run finish.

Example

In the example below, a new run with name "Best run ever" will be created in TestRail on test run finish. Suite id is 321 and assignee is "Deve Loper". Results of the awesome_test1 will be uploaded as result of cases with id 10000, 10001, 10002. Results of the awesome_test2 will be uploaded as result of case with id 20000.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Run Keywords  Test Rail Set Suite Id  1
...          AND           Test Rail Set Run Name  Best run ever
...          AND           Test Rail Set Assignee  Deve Loper

With Case Id
  [Tags]  test_rail_case_id=1
  ... 

With Another Case id
  Test Rail Set Case Id  2

Xray

For successful upload of test run results in Xray two steps must be performed:

  1. Xray integration is configured and enabled in Zebrunner project
  2. Xray configuration is performed on the tests side

Configuration

Zebrunner agent has a special Xray keywords to control results upload:

Xray Set Execution Key <key> : Mandatory. The method sets Xray execution key. This method must be invoked before all tests.

Xray Set Test Key <key> or xray_test_key=<key> : Mandatory. Using these mechanisms you can set test keys associated with specific automated test. It is highly recommended using the xray_test_key tag instead of keyword. Use the keyword only for special cases

Xray Disable Sync : Optional. Disables result upload. Same as Xray Set Execution Key, this method must be invoked before all tests

Xray Enable Real Time Sync : Optional. Enables real-time results upload. In this mode, result of test execution will be uploaded immediately after test finish. Same as Xray Set Execution Key, this method must be invoked before all tests

By default, results will be uploaded to Xray on test run finish.

Example

In the example below, results will be uploaded to execution with key ZBR-42. Results of the awesome_test1 will be uploaded as result of tests with key ZBR-10000, ZBR-10001, ZBR-10002. Results of the awesome_test2 will be uploaded as result of test with key ZBR-20000.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Xray Set Execution Key  ZBR-42


With test key
  [Tags]  xray_test_key=ZBR-10000  xray_test_key=ZBR-10001  xray_test_key=ZBR-10002
  ... 

With Another Test Key
  Xray Set Test Key  ZBR-20000

Zephyr

For successful upload of test run results in Zephyr two steps must be performed:

  1. Zephyr integration is configured and enabled in Zebrunner project
  2. Zephyr configuration is performed on the tests side

Described steps work for both Zephyr Squad and Zephyr Scale.

Configuration

Zebrunner agent has a special Zephyr keywords to control results upload:

Zephyr Set Test Cycle Key <key> : Mandatory. The method sets Zephyr test cycle key. This method must be invoked before all tests.

Zephyr Set Jira Project Key <key> : Mandatory. Sets Zephyr Jira project key. Same as Zephyr Set Test Cycle Key, this method must be invoked before all tests

Zephyr Set Test Case Key <key> or zephyr_test_case_key=<key> : Mandatory. Using these mechanisms you can set test case keys associated with specific automated test. It is highly recommended using the zephyr_test_case_key=1 tag instead of keyword. Use the keyword only for special cases

Zephyr Disable Sync : Optional. Disables result upload. Same as Zephyr Set Test Cycle Key, this method must be invoked before all tests

Zephyr Enable Real Time Sync : Optional. Enables real-time results upload. In this mode, result of test execution will be uploaded immediately after test finish. Same as Zephyr Set Test Cycle Key, this method must be invoked before all tests

By default, results will be uploaded to Zephyr on test run finish.

Example

In the example below, results will be uploaded to test cycle with key ZBR-R42 from project with key ZBR. Results of the awesome_test1 will be uploaded as result of tests with key ZBR-T10000, ZBR-T10001, ZBR-T10002. Results of the awesome_test2 will be uploaded as result of test with key ZBR-T20000.

*** Settings ***
Library     robotframework_zebrunner.ZebrunnerLib
Suite Setup  Run Keywords  Zephyr Set Test Cycle Key  ZBR-R42
...          AND           Zephyr Set Jira Project Key  ZBR


With test key
  [Tags]  zephyr_test_case_key=ZBR-T10000  zephyr_test_case_key=ZBR-T10001  zephyr_test_case_key=ZBR-T10002
  ... 

With Another Test Key
  Zephyr Set Test Case Key  ZBR-T20000


#conftest.py
from pytest_zebrunner.tcm import Zephyr

@pytest.hookimpl(trylast=True)
def pytest_sessionstart(session: Session) -> None:
    Zephyr.set_test_cycle_key("ZBR-R42");
    Zephyr.set_jira_project_key("ZBR");

Selenium WebDriver support

The Zebrunner test agent is capable of tracking tests along with remote Selenium WebDriver sessions.

Capturing session artifacts

Zebrunner supports 3 types of test session artifacts:

  • Video recording
  • Session log
  • VNC streaming

Test agent itself does not capture those artifacts since it has no control over underlying Selenium Grid implementation, however, it is possible to attach appropriate artifact references by providing specially designed set of driver session capabilities (enabling capabilities) - see the table below for more details. Only the True value is considered as trigger to save the link.

Artifact Display name Enabling capability Default reference Reference overriding capability
Video recording Video enableVideo artifacts/test-sessions/<session-id>/video.mp4 videoLink
Session log Log enableLog artifacts/test-sessions/<session-id>/session.log logLink
VNC streaming enableVNC <provider-integration-host>/ws/vnc/<session-id> vncLink

The display name is the name of the artifact that will be displayed on Zebrunner UI. This value is predefined and unfortunately can not be changed at the moment.

The default reference is a reference to a location, where artifact is expected to reside in S3-compatible storage once created by test environment - it is important that it stays in sync with test environment configuration. It is possible to override references if needed by providing reference overriding capabilities. Note, that special <session-id> placeholder is supported and can be used as part of the value of those capabilities allowing runtime session id (generated by WebDriver) to be included into actual reference value.

VNC streaming

VNC is an artifact of a special type. They don't have a name and are not displayed among other artifacts. They are displayed in the video section on Zebrunner UI during session execution and are dropped off on session close.

Default reference to the VNC streaming is based on provider capability. Value of this capability will be converted to preconfigured integration from Test Environment Provider group. The resolved integration must have a filled in URL property and be enabled in order to save the link to VNC streaming. The <provider-integration-host> placeholder of the default link will be replaced by the host of the obtained integration URL. Also, the http protocol in the VNC streaming url will be automatically replaced by ws, and https protocol will be replaced by wss. Currently, we only support Selenium, Zebrunner and MCloud integrations.

Contribution

To check out the project and build from the source, do the following:

git clone git://github.com/zebrunner/python-agent-pytest.git
cd python-agent-pytest

License

Zebrunner reporting agent for PyTest is released under version 2.0 of the Apache License.

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

robotframework_zebrunner-0.3.2.tar.gz (32.0 kB view details)

Uploaded Source

Built Distribution

robotframework_zebrunner-0.3.2-py3-none-any.whl (29.8 kB view details)

Uploaded Python 3

File details

Details for the file robotframework_zebrunner-0.3.2.tar.gz.

File metadata

File hashes

Hashes for robotframework_zebrunner-0.3.2.tar.gz
Algorithm Hash digest
SHA256 c315ca995f71349192ce07f14a1638fe52ff6651f32e3d541f3b51a83c9bffa2
MD5 f20bf42b8d0ae00c9760c909d3a6adb6
BLAKE2b-256 fe99a00409dad97bfc971cb9b3f9af5662107f92e6d63b17592be0254735850a

See more details on using hashes here.

File details

Details for the file robotframework_zebrunner-0.3.2-py3-none-any.whl.

File metadata

File hashes

Hashes for robotframework_zebrunner-0.3.2-py3-none-any.whl
Algorithm Hash digest
SHA256 dbd3e854bf908f8a45cca8dc40fe1fbb1e39dd2d1e5d64d736c7bc29516c9b0e
MD5 cd466de13b15cdda2898eb8d17ee416c
BLAKE2b-256 34c0291de5ba3eba6ed3851e26f265db238b59ff1f9c3c706d0b48ca6dc05e73

See more details on using hashes here.

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page