Skip to main content

Plugin to use continuousflex protocols within the Scipion framework

Project description

This plugin provides the latest Scipion protocols for cryo-EM continuous conformational flexibility/heterogeneity analysis of biomolecular complexes.

Installation

You will need to use 3.0 version of Scipion to be able to run these protocols. To install the plugin, you have two options: We you need help installing Scipion3, please refer to the Scipion Documentation here

Make sure that you have cmake installed on your Linux system. For example, if you are using Ubuntu
sudo apt install cmake
  1. Stable version

    Install Scipion3 and use the plugin manager to install the plugin.

  2. Developer’s version

    • download repository

    git clone https://github.com/scipion-em/scipion-em-continuousflex.git
    git checkout devel
    • install

    scipion3 installp -p path_to_scipion-em-continuousflex --devel

continuousflex sources will be downloaded automatically with the plugin.

Note: Xmipp and Chimerax plugins should be installed (from Scipion3 plugin manager) to run continuousflex protocols. You should also consider having VMD on your system for visualization. We assume that VMD is installed on your system in “/usr/local/lib/vmd”. If VMD is installed but does not work, you may run the command “scipion3 config” and look for VMD_HOME in the config file (the config file is usually at ~/scipion3/config/scipion.conf)

Supported versions

versions > 3.0.15

Protocols

  • HEMNMA: Hybrid Electron Microscopy Normal Mode Analysis method to interpret heterogeneity of a set of single particle cryo-EM images in terms of continuous macromolecular conformational transitions [1-3]

  • StructMap: Structural Mapping method to interpret heterogeneity of a set of single particle cryo-EM maps in terms of continuous conformational transitions [4]

  • HEMNMA-3D: Extension of HEMNMA to continuous conformational variability analysis of macromolecules from in situ cryo-ET subtomograms [5]

Notes:

  • The plugin additionally provides the test data and automated tests of the protocols in Scipion 3. The following two types of tests of HEMNMA and HEMNMA-3D can be produced by running, in the terminal, “scipion3 tests continuousflex.tests.test_workflow_HEMNMA” and “scipion3 tests continuousflex.tests.test_workflow_HEMNMA3D”, respectively: (1) tests of the entire protocol with the flexible references coming from an atomic structure and from an EM map; and (2) test of the alignment module (test run using 5 MPI threads).

  • HEMNMA additionally provides tools for synthesizing noisy and CTF-affected single particle cryo-EM images with flexible or rigid biomolecular conformations, for several types of conformational distributions, from a given atomic structure or an EM map. One part of the noise is applied on the ideal projections before and the other after the CTF, as described in [6].

  • HEMNMA-3D additionally provides tools for synthesizing noisy, CTF and missing wedge affected cryo-ET tomograms and single particle subtomograms with flexible or rigid biomolecular conformations, for several types of conformational distributions, from a given atomic structure or an EM map. One part of the noise is applied on the ideal projections before and the other after the CTF, as described in [6].

  • A reproduction of some utility codes with their corresponding licenses are contained in this plugin for subtomogram averaging, missing wedge correction, denoising and data reading. These codes are not used in the methods above, but they are made optional for data preprocessing and visualization.

References

[1] Jin Q, Sorzano CO, de la Rosa-Trevin JM, Bilbao-Castro JR, Nunez-Ramirez R, Llorca O, Tama F, Jonic S: Iterative elastic 3D-to-2D alignment method using normal modes for studying structural dynamics of large macromolecular complexes. Structure 2014, 22:496-506. [Open-access]

[2] Jonic S: Computational methods for analyzing conformational variability of macromolecular complexes from cryo-electron microscopy images. Curr Opin Struct Biol 2017, 43:114-121. [Link] [Author’s version]

[3] Harastani M, Sorzano CO, Jonic S: Hybrid Electron Microscopy Normal Mode Analysis with Scipion. Protein Sci 2020, 29:223-36. [Open-access]

[4] Sanchez Sorzano CO, Alvarez-Cabrera AL, Kazemi M, Carazo JM, Jonic S: StructMap: Elastic Distance Analysis of Electron Microscopy Maps for Studying Conformational Changes. Biophys J 2016, 110:1753-1765. [Open-access]

[5] Harastani M, Eltsov M, Leforestier A, Jonic S: HEMNMA-3D: Cryo Electron Tomography Method Based on Normal Mode Analysis to Study Continuous Conformational Variability of Macromolecular Complexes. Front Mol Biosci 2021. [Open-access] (in press)

[6] Jonic S, Sorzano CO, Thevenaz P, El-Bez C, De Carlo S, Unser M: Spline-based image-to-volume registration for three-dimensional electron microscopy. Ultramicroscopy 2005, 103:303-317. [Author’s version]

# scipion-em-continuousflex

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

scipion-em-continuousflex-3.0.33.tar.gz (858.2 kB view hashes)

Uploaded Source

Built Distribution

scipion_em_continuousflex-3.0.33-py3-none-any.whl (938.2 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page