Python wrapper for the Sensapex SDK

Project description

Sensapex SDK

This python library wraps the C SDK provided by Sensapex's umsdk. It provides general access to the functions present therein, as well as a device-based abstraction.

Installation

pip install sensapex

This library comes packaged with the latest umsdk library for windows. All other versions can be downloaded and/or compiled separately and configured with UMP.set_library_path.

Usage

from sensapex import UMP

ump = UMP.get_ump()
dev_ids = ump.list_devices()

stage = ump.get_device(20)
stage.calibrate_zero_position()

manipulator = ump.get_device(4)
manipulator.goto_pos((2500.0412, 6810.0003, 15830.1419), speed=200)

pressure = ump.get_device(30)
pressure.set_pressure(1, 2.3e-4)

Also included are some simple test scripts. The following will report on all devices present:

python -m sensapex.test

Or for a more involved test of your hardware as it moves around randomly, install pyqtgraph in your environment and use e.g.:

python -m sensapex.accuracy_test <device_id>

Where <device_id> should be replaced with the numerical ID of your device, as shown by python -m sensapex.test.

ACQ4 Integration

Sensapex stages (uMs), manipulators (uMp) and pressure controllers (uMc) are all well integrated into the ACQ4 neurophysiology platform. To access these devices from ACQ4, simply install sensapex into your ACQ4 environment and add appropriate configuration. In default.cfg add:

drivers:
    sensapex:
        group: 0  # [default] of Group 'A' or whatever numeric index corresponds to your hardware
        debug: False  # [default] or True to get debug logging as described below
        address: "169.254.255.255"  # [default] or whatever your hardware's broadcast address is
        driverPath: None  # [default] to using standard OS library searches or set to a custom location

And in devices.cfg, add any number of the following device configuration sections (named distinctly):

Stage:
    driver: "Sensapex"
    nAxes: 3
    deviceId: 20
    # ...

ObjectiveChanger:
    driver: 'SensapexObjectiveChanger'
    deviceId: 20
    # ...

Manipulator1:
    driver: "Sensapex"
    isManipulator: True
    deviceId: 1
    # ...

Pressure1:
    Driver: "SensapexPressureControl"
    deviceId: 30
    pressureChannel: 1

Debug

You can turn on debugging to produce detailed logs and network packet captures. First, install Wireshark (or for linux, use your package manager to get the pcaputils package). Make sure the user account you use has permission to run the dumpcap program. Next, install the psutil python package:

pip install psutil

Once those are installed, you can turn on the debug logging for your SDK wrapper:

from sensapex import UMP

UMP.set_debug_mode(True)
ump = UMP.get_ump()

This will create a directory, sensapex-debug/ in the current working directory, populated with a log file and a pcap file. Repeated initializations of the debug mode will create addition pcap files and append to the log file. These can be sent to Sensapex along with any relevant details, such as:

  • A description of errant behavior
  • The color of each of the relevant device lights
  • A picture of the touchscreen state
  • Steps to reproduce and how consistently it occurs

Authorship

Copyright (c) 2016-2021 Sensapex Oy

Thanks to the following for contributions:

  • Luke Campagnola
  • Ari Salmi
  • Martin Chase
  • Thomas Braun

Changelog

1.400.3

  • Bump up minimum SDK version

1.400.2

  • Bugfix for non-simultaneous moves on stages
  • SensapexDevice.is_stage is now available (and can be overridden with an init arg)

1.400.1

1.400.0

  • Update to latest driver
  • Accuracy test for 4-axis devices (ignoring the 4th axis)

1.022.8

  • Include ACQ4 integration instructions in README

1.022.7

  • Packaging fix to include driver binary.
  • find_library to find libum in default locations.

1.022.6

  • More accuracy_test improvements.
  • Handle floating point movements.

1.022.5

  • The accuracy_test script now takes --linear to test linear movements.

1.022.4

  • Binary installer works in develop mode
  • Errors no longer prevent other devices from moving
  • Allow init args for UMP.get_device (to avoid n_axes race)

1.022.3

  • Bad MoveRequests should blow up on init, rather than during movement.

1.022.2

  • A bunch of fixes from Luke.

1.022.1

  • Debug mode: logs, hardware details and PCAP
  • Bugfix in default library path for test scripts

1.022.0

  • Setup bdist_wheel that pre-downloads the SDK
  • Bump SDK version to the latest

1.021.2

  • SDK version bump

1.021.1

  • Move-finish error capture
  • Use new windows library name

1.021.0

  • Update to new version

0.920.4

  • Pressure devices don't need positioning callbacks

0.920.3

  • Expose more pressure functions.

0.920.2

  • Workaround for sdk bug in motion planning

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

sensapex-1.400.3.tar.gz (26.4 kB view details)

Uploaded Source

File details

Details for the file sensapex-1.400.3.tar.gz.

File metadata

  • Download URL: sensapex-1.400.3.tar.gz
  • Upload date:
  • Size: 26.4 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/5.0.0 CPython/3.11.7

File hashes

Hashes for sensapex-1.400.3.tar.gz
Algorithm Hash digest
SHA256 12d4543570daa5aaddaa224451e9eb6092bdf336c9aaf43716f3fcbb97045d78
MD5 04277f9f896b92abb9f641577c9d7aec
BLAKE2b-256 1925828491c7dbb2354c2af4ab0af1053f6c89cdbdee2488aec1f75151166863

See more details on using hashes here.

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page