Skip to main content

Library to interface Sunsynk Hybrid Inverters

Project description

Sunsynk Inverters

This repo enables access to Sunsynk Hybrid Inverter through a Python 3 library. It also provides an Add-On that can be installed in the Home Assistant OS.

See https://www.sunsynk.org/ for more information on Sunsynk inverters.

This code was developed on a Sunsynk 5.5 kWh.

DISCLAIMER: Use at your own risk! Especially when writing any settings.

Sunsynk Python Library

codecov

The Python library is available through pip:

pip install sunsynk

Home Assistant Sunsynk Add-On

For the Add-On you require Home Assistant OS and a RS-485 adaptor to connect to your Sunsynk inverter. Sensors are read using the Modbus protocol and sent to a MQTT server. Below an example of the HomeAssistant Energy management dashboard using sensors from the Sunsynk.

HASS Energy management

Add-On Installation

  1. Add the repository to your HA Supervisor
    Open your Home Assistant instance and show the add add-on repository dialog with a specific repository URL pre-filled. https://github.com/kellerza/sunsynk

  2. Install the Sunsynk Add-On from the Add-On Store and configure through the UI

Add-on Deployment

The Sunsynk Add-on runs on the Home Assistant OS, reads the Inverter's Modbus registers over RS-485, and publishes sensor values to the MQTT server. The architecture is shown below:

Deployment Option

If the Inverter is far from the server/SBC running Home Assistant, you have several ways to extend the deployment:

  1. The preferred remote option is to use MQTT over your home network toward the main MQTT server (typically on the same server as Home Assistant)

    Deployment Option MQTT

  2. Another option is to use a Modbus TCP to RTU/serial gateway. This can be another Raspberry Pi, even an old one, running the gateway software, like mbusd.

    You can also use a commercial Modbus gateway, like the USR-W630 (reported via Powerforum)

    Deployment Option Gateway

Tested Inverters

There are several inverters that are rebranded Deye inverters, so you might have success with other inverter brands as well, please add your inverter by editing this file and creating a Pull Request if you are successful.

Inverter Model Battery Version User Port(s)
Sunsynk 3.6kW Sunsynk SSLB1 beta/all @reedy BMS485 (top left)
Sunsynk 5.5kW Hubble AM-2 beta/all @kellerza BMS485 (top left)
Sunsynk 8.8kW BSL 8.2 kWH 0.0.8 @dirkackerman RS485 (1 in image below)
Deye 8kW Pylontech US3000C 0.1.3dev @Kladrie RS485 (top left)
Turbo-E 5kW DIY with JKBMS 0.1.4 @agtconf BMS485 (top left)

Sunsynk 3.6kW Inverter

Sunsynk 5.5kW Inverter

Tested with: USB-to-RS485 adaptor sourced from Banggood, very similar to this.

NOTE: RJ-45 port marked RS485 (bottom right) does not work.

Sunsynk 8.8kW Inverter

Tested with: USB-to-485 adaptor sourced from Micro Robotics, here

Deye 8kW Inverter

RS485 is the blue line - top left, as with the Sunsynk inverters. Yellow is the CAN-comms with the Pylontech batteries

Turbo-Energy 5kW Inverter

Tested with: USB-to-RS485 adaptor sourced from Aliexpress, very similar to this.

Hardware

The RJ-45 plug on the inverter side is crimped according to T568A. RS485 requires a twisted pair, so works well with CAT5 network cable and the RJ-45 connectors.

RJ45 Pin
(inverter side)
Wire Color
(using T568A)
USB-to-RS485
adaptor
1 Green-White B/D-
2 Green A/D+
3* Orange-White GND

* tested on Sunsynk 8.8kW only

Fault finding

If you fail to get a reply from the inverter, please check the following

(a) Only a single connection to the serial port

Ensure you only have a single addon connected to the serial port. The following can all potentially access the USB port: mbusd, Node RED, the normal and dev addon version.

If you need to have multiple connections to the serial port: ONLY connect mbusd to the serial port. Connect all addons to mbusd (e.g. tcp://192.168.1.x:503 )

(b) Check the Modbus Server ID

Ensure the Modbus server ID (MODBUS_SERVER_ID config setting) setting matches the configured Modbus SN value of the inverter

View/update the Modbus server ID on your inverter under "Advanced Settings" / "Multi-Inverter"

Credits

Information in the Power forum was especially helpful to get this up and running, see this thread

Special Kudos to Bloubul7, @jacauc and Sc00bs.

The original Node-RED flows can be found on @jacauc's repo here

Sunsynk 8.8kW diagram from system32 in this thread

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

sunsynk-0.2.0.tar.gz (20.2 kB view details)

Uploaded Source

Built Distribution

sunsynk-0.2.0-py3-none-any.whl (25.0 kB view details)

Uploaded Python 3

File details

Details for the file sunsynk-0.2.0.tar.gz.

File metadata

  • Download URL: sunsynk-0.2.0.tar.gz
  • Upload date:
  • Size: 20.2 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/4.0.1 CPython/3.9.13

File hashes

Hashes for sunsynk-0.2.0.tar.gz
Algorithm Hash digest
SHA256 035b4ac7e141f36ce31e0fec9a201206210026d2adaa47b3050c66190a90a83b
MD5 26aa86a3f2fdf9451c2a4198c9e2233e
BLAKE2b-256 8ffc40ec7a332c556d7190da9651383b29281f08aa8c498f9cebd1e65714f478

See more details on using hashes here.

File details

Details for the file sunsynk-0.2.0-py3-none-any.whl.

File metadata

  • Download URL: sunsynk-0.2.0-py3-none-any.whl
  • Upload date:
  • Size: 25.0 kB
  • Tags: Python 3
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/4.0.1 CPython/3.9.13

File hashes

Hashes for sunsynk-0.2.0-py3-none-any.whl
Algorithm Hash digest
SHA256 5d9c75a18216c07737b8fa80cd3e4c99b3c40e1ab4ea41a4e628ddd19abc5531
MD5 7dff50e4c06b9234f09805ebcc94ab5a
BLAKE2b-256 5298e9eb1a39bc6a6f41ef0fbbf5b92775670c7b1d4dac9a8ab88b3f89824e68

See more details on using hashes here.

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page