Modbus driver supported and maintained by the Volttron team.
Project description
volttron-lib-modbus-driver
Note VOLTTRON’s modbus driver supports the Modbus over TCP/IP protocol only.
Requires
- python >=3.10
- volttron-lib-base-driver
- pymodbus >= 2.3.5
Documentation
More detailed documentation can be found on ReadTheDocs. The RST source of the documentation for this component is located in the "docs" directory of this repository.
Installation
Before installing, VOLTTRON should be installed and running. Its virtual environment should be active. Information on how to install of the VOLTTRON platform can be found here.
-
If it is not already, install the VOLTTRON Platform Driver Agent:
vctl install volttron-platform-driver --vip-identity platform.driver --start
-
Install the volttron-lib-modbus-driver library.
pip install volttron-lib-modbus-driver
-
Store device and registry files for the Modbus device to the Platform Driver configuration store:
Create a driver configuration file called
modbus.config
. There are three arguments for the driver_config section of the device configuration file:-
device_address: IP Address of the device.
-
port: Port the device is listening on. Defaults to 502 which is the standard port for Modbus devices.
-
slave_id: Slave ID of the device. Defaults to 0. Use 0 for no slave.
This repo provides an example configuration in the file "modbus_example.config".
Here is an example device configuration file:
{ "driver_config": {"device_address": "10.0.0.4"}, "driver_type": "modbus", "registry_config":"config://catalyst371.csv", "interval": 120, "timezone": "UTC", "campus": "campus", "building": "building", "unit": "modbus1", "heart_beat_point": "ESMMode" }
Create another file called
mobus.csv
. This CSV file will be your modbus registry configuration file. Each row configures a point on the device.The following columns are required for each row:
-
Volttron Point Name - The name by which the platform and agents will refer to this point.
-
Units - Used for meta data when creating point information on the historian.
-
Modbus Register - A string representing how to interpret the binary format of the data register. The string takes two forms:
-
“BOOL” for coils and discrete inputs.
-
A format string for the Python struct module. See the Python3 Struct docs for full documentation. The supplied format string must only represent one value. See the documentation of your device to determine how to interpret the registers. Some Examples:
-
“>f” - A big endian 32-bit floating point number.
-
“<H” - A little endian 16-bit unsigned integer.
-
“>l” - A big endian 32-bit integer.
-
-
Writable - Either TRUE or FALSE. Determines if the point can be written to.
-
Point Address - Modbus address of the point. Cannot include any offset value, it must be the exact value of the address.
-
Mixed Endian - (Optional) Either TRUE or FALSE. For mixed endian values. This will reverse the order of the Modbus registers that make up this point before parsing the value or writing it out to the device. Has no effect on bit values.
The following column is optional:
- Default Value - The default value for the point. When the point is reverted by an agent it will change back to this value. If this value is missing it will revert to the last known value not set by an agent.
Any additional columns will be ignored. It is common practice to include a Point Name or Reference Point Name to include the device documentation’s name for the point and Notes and Unit Details for additional information about a point.
The following is an example of a Modbus registry configuration file:
Reference Point Name,Volttron Point Name,Units,Units Details,Modbus Register,Writable,Point Address,Default Value,Notes CO2Sensor,ReturnAirCO2,PPM,0.00-2000.00,>f,FALSE,1001,,CO2 Reading 0.00-2000.0 ppm CO2Stpt,ReturnAirCO2Stpt,PPM,1000.00 (default),>f,TRUE,1011,1000,Setpoint to enable demand control ventilation Cool1Spd,CoolSupplyFanSpeed1,%,0.00 to 100.00 (75 default),>f,TRUE,1005,75,Fan speed on cool 1 call Cool2Spd,CoolSupplyFanSpeed2,%,0.00 to 100.00 (90 default),>f,TRUE,1007,90,Fan speed on Cool2 Call Damper,DamperSignal,%,0.00 - 100.00,>f,FALSE,1023,,Output to the economizer damper DaTemp,DischargeAirTemperature,F,(-)39.99 to 248.00,>f,FALSE,1009,,Discharge air reading ESMEconMin,ESMDamperMinPosition,%,0.00 to 100.00 (5 default),>f,TRUE,1013,5,Minimum damper position during the energy savings mode FanPower,SupplyFanPower, kW,0.00 to 100.00,>f,FALSE,1015,,Fan power from drive FanSpeed,SupplyFanSpeed,%,0.00 to 100.00,>f,FALSE,1003,,Fan speed from drive HeatCall1,HeatCall1,On / Off,on/off,BOOL,FALSE,1113,,Status indicator of heating stage 1 need HeartBeat,heartbeat,On / Off,on/off,BOOL,FALSE,1114,,Status indicator of heating stage 2 need
Add modbus.csv and modbus.config to the configuration store:
vctl config store platform.driver devices/campus/building/modbus modbus.config vctl config store platform.driver modbus.csv modbus.csv --csv
-
-
Observe Data
To see data being published to the bus, install a Listener Agent:
vctl install volttron-listener --start
Once installed, you should see the data being published by viewing the Volttron logs file that was created in step 2. To watch the logs, open a separate terminal and run the following command:
tail -f <path to folder containing volttron.log>/volttron.log
Development
Please see the following for contributing guidelines contributing.
Please see the following helpful guide about developing modular VOLTTRON agents
Disclaimer Notice
This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor Battelle, nor any of their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights.
Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
Built Distribution
File details
Details for the file volttron_lib_modbus_driver-0.2.1rc0.tar.gz
.
File metadata
- Download URL: volttron_lib_modbus_driver-0.2.1rc0.tar.gz
- Upload date:
- Size: 14.6 kB
- Tags: Source
- Uploaded using Trusted Publishing? No
- Uploaded via: poetry/1.4.2 CPython/3.10.11 Linux/5.15.0-1037-azure
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 088be2740354f16d83ff1299bf4deee3447c796bea70cba2a5101c1b695dab69 |
|
MD5 | 9f4381751ff14b9bb359fbe4ef44d45e |
|
BLAKE2b-256 | 377c7e804892457048c5b524eae5dc139255a1d09322e9afee05470196f3297b |
File details
Details for the file volttron_lib_modbus_driver-0.2.1rc0-py3-none-any.whl
.
File metadata
- Download URL: volttron_lib_modbus_driver-0.2.1rc0-py3-none-any.whl
- Upload date:
- Size: 12.8 kB
- Tags: Python 3
- Uploaded using Trusted Publishing? No
- Uploaded via: poetry/1.4.2 CPython/3.10.11 Linux/5.15.0-1037-azure
File hashes
Algorithm | Hash digest | |
---|---|---|
SHA256 | 43b0daf0a72fc68a1cf5df1ef0b5b9610da00fbd96450b8ca65c3ac2b1e2540e |
|
MD5 | 7f13be37c8f2d23bf49dc2658deaff02 |
|
BLAKE2b-256 | abc29022378a3319ff0241becd6d92b15e0c1867817cb651313361379dabc74c |