Driver to get measures from a flowmeter.
Project description
DRIVER FOR FLOWMETER
-
Introduction
The purpose of this package is to communicate with the flowmeter, read the measurements and save them to a csv file. To do this, you need one or two flowmeters and an Arduino Uno.
-
Flowmeter features
Flow range: 0.05 l/min - 10 l/min.
Supply voltage: 4.5V -24V.
Rated current: 8mA.
Output: NPN/PNP pulse current
Pipe diameter range: 8mm.
Connections:- Blue: Output. - Red: +4,5 - 24V. - Screen 0 V.
-
Arduino connection diagram
Power of the arduino through the usb to usb port of the controller.
Flow main:
- Blue: Pin 2 - Red: 5V - Screen: GND
Flow aux:
- Blue: Pin 8 - Red: 5V - Screen: GND
-
SCPI Commands
- Message: 'IDN*?' Response: ':IDN:FLOWmeter:DEVice: Device_number :VERsion: firmware_version \n'
- Message: ':MEASure:FLOW?' Response: ':MEASure:FLOW:DATA flow_main flow_aux \n'
-
References
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
wattrex-driver-flow-0.0.3.tar.gz
(44.2 kB
view hashes)
Built Distribution
Close
Hashes for wattrex-driver-flow-0.0.3.tar.gz
Algorithm | Hash digest | |
---|---|---|
SHA256 | 42c46cbb1ba7a6187acd93aff2acb9286fce9be5b46fe38529cda70a1baecb02 |
|
MD5 | fd8b4fbfa16bb290018ed803c29c83ef |
|
BLAKE2b-256 | ddbf5a5771960af80f192ddf4c23237946c10185218a420664061151624c52d2 |
Close
Hashes for wattrex_driver_flow-0.0.3-py3-none-any.whl
Algorithm | Hash digest | |
---|---|---|
SHA256 | d0277a059a8c5fdeeff5476796035604fd6fbabfe542cbd260a6c991df6b24aa |
|
MD5 | 18e273c46b93c698a1639a650c672573 |
|
BLAKE2b-256 | def102058f50ed2df5247bd77fc5b27aaf6825d4a5b67d419f8a5da13005864a |