A Python API for Thermia heat pumps using https://online.thermia.se
Project description
Thermia Online API
A Python API for Thermia heat pumps using https://online.thermia.se
Confirmed Thermia profiles that API supports:
- Thermia Diplomat / Diplomat Duo
- Thermia iTec
Confirmed Thermia models that API supports:
- Danfoss DHP-AQ 9
Supported APIs:
classic
, default, online access url is https://online.thermia.segenesis
, online access url is https://online-genesis.thermia.se
How to use api:
See example.py file
Available functions in Thermia class:
Function | Description |
---|---|
fetch_heat_pumps |
Fetches all heat pumps from Thermia Online API and their data |
update_data |
Updates all heat pump data |
Available properties within ThermiaHeatPump class:
Property | Description |
---|---|
name |
Name of the Heat Pump |
id |
Unique ID of the Heat Pump Thermia generates |
is_online |
Boolean value indicating if the Heat Pump is online or not |
model |
Model of the Heat Pump |
last_online |
DateTime string indicating the last time the Heat Pump was online |
has_indoor_temperature_sensor |
Boolean value indicating if the Heat Pump has an indoor temperature sensor |
indoor_temperature |
Indoor temperature in Celsius, if has_indoor_temperature_sensor is False, this value is the same as heat_temperature |
is_outdoor_temp_sensor_functioning |
Boolean value indicating if the Heat Pump has an outdoor temperature sensor |
outdoor_temperature |
Outdoor temperature in Celsius |
is_hot_water_active |
Boolean value indicating if the Heat Pump is heating water |
hot_water_temperature |
Hot water temperature in Celsius |
heat_temperature |
Heat Pump heating target temperature in Celsius |
heat_min_temperature_value |
Minimum temperature value possible for Heat Pump to set |
heat_max_temperature_value |
Maximum temperature value possible for Heat Pump to set |
heat_temperature_step |
Step value for temperature setting |
--- | --- |
Other temperatures | |
supply_line_temperature |
Supply line temperature in Celsius |
desired_supply_line_temperature |
Desired supply line temperature in Celsius |
return_line_temperature |
Return line temperature in Celsius |
brine_out_temperature |
Brine out temperature in Celsius |
brine_in_temperature |
Brine in temperature in Celsius |
cooling_tank_temperature |
Cooling tank temperature in Celsius |
cooling_supply_line_temperature |
Cooling supply line temperature in Celsius |
--- | --- |
Operational status | |
operational_status |
Operational status of the Heat Pump |
available_operational_statuses |
List of available operational statuses |
available_operational_statuses_map |
Dictionary mapping operational status names to their values |
--- | --- |
Operational Times | |
compressor_operational_time |
Compressor operational time in hours |
hot_water_operational_time |
Hot water operational time in hours |
auxiliary_heater_1_operational_time |
Auxiliary heater 1 operational time in hours |
auxiliary_heater_2_operational_time |
Auxiliary heater 2 operational time in hours |
auxiliary_heater_3_operational_time |
Auxiliary heater 3 operational time in hours |
--- | --- |
Alarms data | |
active_alarm_count |
Number of active alarms on the Heat Pump |
active_alarms |
List of titles of active alarms on the Heat Pump |
--- | --- |
Operation Mode data | |
operation_mode |
Current operation mode of the Heat Pump |
available_operation_modes |
List of available operation modes for the Heat Pump |
available_operation_mode_map |
Dictionary mapping operation mode names to their values |
--- | --- |
Hot Water data | |
is_operation_mode_read_only |
Boolean value indicating if the Heat Pump operation mode is read-only |
is_hot_water_switch_available |
Boolean value indicating if the Heat Pump has a hot water switch |
Available functions within ThermiaHeatPump class:
Function | Description |
---|---|
update_data |
Refetch all data from Thermia for Heat Pump |
set_temperature |
Set the target temperature for the Heat Pump |
set_operation_mode |
Set the operation mode for the Heat Pump |
set_hot_water_switch_state |
Set the hot water switch state to 0 (off) or 1 (on) for the Heat Pump |
Project details
Release history Release notifications | RSS feed
Download files
Download the file for your platform. If you're not sure which to choose, learn more about installing packages.
Source Distribution
ThermiaOnlineAPI-2.12.tar.gz
(21.6 kB
view hashes)
Built Distribution
Close
Hashes for ThermiaOnlineAPI-2.12-py3-none-any.whl
Algorithm | Hash digest | |
---|---|---|
SHA256 | bb56958295b6b5755e3e39aea07dc1c25f31788676ad10a9c0e2624d488af187 |
|
MD5 | 12591bf32b3da72d3571455b50e202f2 |
|
BLAKE2b-256 | e341cab58a242524922dc184aa3f6aa2d7408b5a2bcc2c1835cb03fed6ecb01e |