THE standard library for Modbus RTU and Modbus TCP - See www.EasyModbusTCP.NET for documentation

Project description

EasyModbusTCP - THE standard library for Modbus RTU and Modbus TCP

Visit www.EasyModbusTCP.net for more informations and Codesamples

Table of Contents

  1. Installation
  2. Supported Function codes
  3. Basic Usage
    3.1. Instantiation
    3.2. Connect
    3.3. Close connection
    3.4. Read values
    3.5. Write single values
  4. Examples
    4.1. Example 1 (Read two Holding Registres from Siemens S7-1200 via Modbus-TCP)
  5. Library Documentation
    5.1 Methods
    5.2 Properties
    5.3 Helper functions

1. Installation:

pip install EasyModbus

Requirements:

Python 3.8

pyserial (only for Modbus RTU)

2. Supported Function codes

  • Read Coils (FC1)
  • Read Discrete Inputs (FC2)
  • Read Holding Registers (FC3)
  • Read Input Registers (FC4)
  • Write Single Coil (FC5)
  • Write Single Register (FC6)
  • Write Multiple Coils (FC15)
  • Write Multiple Registers (FC16)

3. Basic usage

3.1 Instantiate ModbusClient class

The arguments passed during the instantiation are important in order to differentiate between Modbus RTU (via the serial interface) and Modbus TCP (via Ethernet).
If an argument is passed during the instantiation, it is the serial interface that is used with Modbus RTU (e.g. 'COM1' or '/dev/ttyUSB0'). Two arguments must be passed for Modbus TCP. This is the IP address and the port (usually 502)

Example for Modbus RTU

import easymodbus.modbusClient
modbus_client = easymodbus.modbusClient.ModbusClient('/dev/ttyUSB0')

Example for Modbus TCP

import easymodbus.modbusClient
modbus_client = easymodbus.modbusClient.ModbusClient('192.168.178.52', 502)

3.2 Connect

To connect to a Modbus-TCP Server or to a Modbus-RTU Slave simply use the "connect" Method. If Modbus-RTU is used, make sure to set the properties for serial connection (Baudrate, Parity, Stopbits), if they differ from the default values, before the "connect" Method is executed.

modbus_client.connect()

3.3 Close connection

To close the connection to a Modbus-TCP Server or to a Modbus-RTU Slave simply use the "close" Method.

modbus_client.close()

3.4 Read Values

The following functioncodes are used to read values from the remote device (Modbus-TCP Server or Modbus-RTU Client)

  • Read Coils (FC1) - Method "read_coils"
  • Read Discrete Inputs (FC2) - Method "read_discrete_inputs"
  • Read Holding Registers (FC3) - Method "read_holding_registers"
  • Read Input Registers (FC4) - Method "read_input_registers"

IMPORTANT: Usually there is a Register shift between the request and the server address range The Server address Range starts with address "1" but the Request that is sent starts with "0" In the example method call we read Register 1 and 2 (Because register "0" does not exist) Please check the documentation of your device (or try it out)

import easymodbus.modbusClient

#create an instance of a Modbus-TCP class (Server IP-Address and Port) and connect
modbus_client = easymodbus.modbusClient.ModbusClient('192.168.178.110', 502)
modbus_client.connect()

#The first argument is the starting address, the second argument is the quantity.
coils = modbus_client.read_coils(0, 2)	#Read coils 1 and 2 from server 
discrete_inputs = modbus_client.read_discreteinputs(10, 10)	#Read discrete inputs 11 to 20 from server 
input_registers = modbus_client.read_inputregisters(0, 10)	#Read input registers 1 to 10 from server 
holding_registers = modbus_client.read_holdingregisters(0, 5)	#Read holding registers 1 to 5 from server 
modbus_client.close()

3.5 Write single Values

The following functioncodes are used to write single values (Holding Registers or Coils) from the remote device (Modbus-TCP Server or Modbus-RTU Client)

  • Write Single Coil (FC5) - Method "write_single_coil"
  • Write Single Register (FC6) - Method "write_single_register"

IMPORTANT: Usually there is a Register shift between the request and the server address range The Server address Range starts with address "1" but the Request that is sent starts with "0" In the example method call we write to Register 1 (Because register "0" does not exist) Please check the documentation of your device (or try it out)

import easymodbus.modbusClient

#create an instance of a Modbus-TCP class (Server IP-Address and Port) and connect
modbus_client = easymodbus.modbusClient.ModbusClient('192.168.178.110', 502)
modbus_client.connect()

holding_register_value = 115
coil_value = True
#The first argument is the address, the second argument is the value.
modbus_client.write_single_register(0, holding_register_value)	#Write value "115" to Holding Register 1 
modbus_client.write_single_coil(10, coil_value)	#Set Coil 11 to True
modbus_client.close()

4. Get started - Examples

All examples are available in the folder "examples" in the Git-Repository

4.1 Example 1 (Read two Holding Registres from Modbus-TCP Server)

First we create an instance of a Modbus-TCP class (Server IP-Address and Port) Then we Read 2 Holding Registers from the Server.
IMPORTANT: Usually there is a Register shift between the request and the server address range The Server address Range starts with address "1" but the Request that is sent starts with "0" In the example method call we read Register 1 and 2 (Because register "0" does not exist) Please check the documentation of your device (or try it out)

import easymodbus.modbusClient

#create an instance of a Modbus-TCP class (Server IP-Address and Port) and connect
modbus_client = easymodbus.modbusClient.ModbusClient('192.168.178.110', 502)
modbus_client.connect()

#The first argument is the starting registers, the second argument is the quantity.
register_values = modbus_client.read_holdingregisters(0, 2)

print("Value of Register #1:" + str(register_values[0]))
print("Value of Register #2:" + str(register_values[1])) 

#Close the Port
modbus_client.close()

5. Library Documentation

Class: ModbusClient

5.1 Methods

Constructor def __init__(self, *params)

Constructor for Modbus RTU (serial line): modbusClient = ModbusClient.ModbusClient(‘COM1’) First Parameter is the serial Port

Constructor for Modbus TCP: modbusClient = ModbusClient.ModbusClient(‘127.0.0.1’, 502) First Parameter ist the IP-Address of the Server to connect to Second Parameter is the Port the Server listens to

def connect(self)

Connects to a Modbus-TCP Server or a Modbus-RTU Slave with the given Parameters

def close(self)

Closes Serial port, or TCP-Socket connection

def read_discrete_inputs(self, starting_address, quantity)

Read Discrete Inputs from Server device (Function code 2)
starting_address: First discrete input to read
quantity: Number of discrete Inputs to read
returns: List of bool values [0..quantity-1] which contains the discrete Inputs

def read_coils(self, starting_address, quantity)

Read Coils from Server device (Function code 1)
starting_address: First coil to read
quantity: Number of coils to read
returns: List of bool values [0..quantity-1] which contains the coils

def read_holding_registers(self, starting_address, quantity)

Read Holding Registers from Server device (Function code 3)
starting_address: First Holding Register to read
quantity: Number of Holding Registers to read
returns: List of int values [0..quantity-1] which contains the registers

def read_input_registers(self, starting_address, quantity)

Read Input Registers from Server device (Function code 4)
starting_address: First Input Register to read
quantity: Number of Input Registers to read
returns: List of int values [0..quantity-1] which contains the registers

def write_single_coil(self, starting_address, value)

Write single Coil to Server device (Function code 5)
starting_address: Coil to write
value: Boolean value to write

def write_single_register(self, starting_address, value)

Write single Holding Register to Server device (Function code 6)
starting_address: Holding Register to write
value: int value to write

def write_multiple_coils(self, starting_address, values)

Write multiple Coils to Server device (Function code 15)
starting_address: First coil to write
value: List of Boolean values to write

def write_multiple_registers(self, starting_address, values)

Write multiple Holding Registers to Server device (Function code 16)
starting_address: First Holding Register to write
value: List of int values to write

def read_discreteinputs(self, starting_address, quantity)

deprecated - Use "read_discrete_inputs" instead

def read_holdingregisters(self, starting_address, quantity)

deprecated - Use "read_holding_registers" instead

def read_inputregisters(self, starting_address, quantity)

deprecated - Use "read_input_registers" instead

5.2 Properties

port

Datatype: int
Port were the Modbus-TCP Server is reachable (Standard is 502)

ipaddress

Datatype: str
IP-Address of the Server to be connected

unitidentifier

Datatype: int
Unit identifier in case of serial connection (Default = 1)

baudrate

Datatype: int
Baudrate for serial connection (Default = 9600)

parity

Datatype: int
Parity in case of serial connection The Helper class "Parity" can be used to define the parity (Default = Parity.even)
For example: modbus_client.parity = easymodbus.modbusClient.Parity.odd
Possible values are: even = 0
odd = 1
none = 2

stopbits

Datatype: int
Stopbits in case of serial connection (Default = Stopbits.one) The Helper class "Stopbits" can be used to define the number of stopbits
For example: modbus_client.stopbits = easymodbus.modbusClient.Stopbits.one
Possible values are: one = 0
two = 1
onePointFive = 2

timeout

Datatype: int
Max. time before an Exception is thrown (Default = 5)

is_connected

Datatype: bool
Returns true if a connection has been established (only read)

debug

Datatype: bool
Enables/disables debug mode - In debug mode Request and Response and depending in the logging level the RAW-Data are displayed at the console output and stored in a logfile "logdata.txt"
Disabled at default

logging_level

Sets or gets the logging level. Default value is logging.INFO. In this Request and Response including arguments are logged (if debug is enabled)
if the level is set to logging.DEBUG also the RAW data transmitted and received are logged for debugging purposes.
The are logged at the console output and stored in logfile.txt

5.3 Helper functions

def convert_double_to_two_registers(doubleValue, register_order=RegisterOrder.lowHigh)

Convert 32 Bit Value to two 16 Bit Value to send as Modbus Registers
doubleValue: Value to be converted
register_order: Desired Word Order (Low Register first or High Register first - Default: RegisterOrder.lowHigh
return: 16 Bit Register values int[]

def convert_float_to_two_registers(floatValue, register_order=RegisterOrder.lowHigh)

Convert 32 Bit real Value to two 16 Bit Value to send as Modbus Registers
floatValue: Value to be converted
register_order: Desired Word Order (Low Register first or High Register first - Default: RegisterOrder.lowHigh
return: 16 Bit Register values int[]

def convert_registers_to_double(registers, register_order=RegisterOrder.lowHigh)

Convert two 16 Bit Registers to 32 Bit long value - Used to receive 32 Bit values from Modbus (Modbus Registers are 16 Bit long)
registers: 16 Bit Registers
register_order: Desired Word Order (Low Register first or High Register first - Default: RegisterOrder.lowHigh
return: 32 bit value

def convert_registers_to_float(registers, register_order=RegisterOrder.lowHigh)

Convert two 16 Bit Registers to 32 Bit real value - Used to receive float values from Modbus (Modbus Registers are 16 Bit long)
registers: 16 Bit Registers
register_order: Desired Word Order (Low Register first or High Register first - Default: RegisterOrder.lowHigh
return: 32 bit value real

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

EasyModbus-2.0.1.tar.gz (17.2 kB view details)

Uploaded Source

File details

Details for the file EasyModbus-2.0.1.tar.gz.

File metadata

  • Download URL: EasyModbus-2.0.1.tar.gz
  • Upload date:
  • Size: 17.2 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/3.1.1 pkginfo/1.5.0.1 requests/2.22.0 setuptools/41.2.0 requests-toolbelt/0.9.1 tqdm/4.40.1 CPython/3.8.0

File hashes

Hashes for EasyModbus-2.0.1.tar.gz
Algorithm Hash digest
SHA256 aadd591fa105c1de02034743283a4cde55f93c8634f62a191513ef636edb6dfc
MD5 82e34f557cf5071cfd10c580085cf4b4
BLAKE2b-256 433cc5f9a38041347d27e0f8393a93a850fee4c3efeb4ee9487d793f4009d9a1

See more details on using hashes here.

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page