A package for predicting the HTC of a building using smart meter data.

Project description

pysmeter

A package for estimating the Heat Transfer Coefficient of a domestic building using smart meter data.

Background

SMETER = Smart Meter Enabled Thermal Efficiency Rating

This package was borne out of an innovation competition run by BEIS (the UK Government Department for Business, Energy and Industrial Strategy) whose aim was to find unobtrusive and cost-effective ways of determining the HTC of a domestic building using smart meter data.

The team at the Centre for Sustainable Energy developed a machine learning model which uses the following data series collected from the dwelling (all measurements are taken half-hourly):

  • Average indoor temperature*
  • Outdoor temperature**
  • Gas kWh
  • Electricity kWh

* Readings can be taken with any good temperature logger. Loggers should be placed in as many rooms as possible and the mean taken across all rooms.

** A single logger should be placed outside the dwelling within a Stevenson screen to shield it from direct sunlight.

For more info on the physical setup of sensors, see the guidance.

From these data the model produces an estimate of the HTC of the building, as would be found by performing a co-heating test. The model itself is an ensemble of convolutional neural networks built with Tensorflow.

Installation

Install with pip:

pip install pysmeter

It is recommended that you use a virtual env. Python >= 3.6 ships with venv in the standard library, so you can do:

python3 -m venv /path/to/new/virtual/environment
cd /path/to/new/virtual/environment
source bin/activate
pip install pysmeter

The install does not include the model files themselves, as they are very large (~300MB). These need to be downloaded separately after installation:

python3 -m pysmeter.download_model

This downloads the model files to /usr/share/smeter-models (Linux) or /usr/local/share/smeter-models (Mac). You may need to run this command as root.

Usage

Python module

It is generally expected that you will use pysmeter within an existing Python project. The package exposes a single function, pysmeter.model.predict, which makes an HTC prediction based on the input array. The input array can be either two-dimensional (if there is only one building) or three-dimensional (more than one building). The dimensions are:

  • [number of houses x] timesteps x channels

There are always four channels: indoor temp, outdoor temp, gas, elec.

The number of timesteps should be at least 1008 (i.e. 3 weeks worth of half hours). The current model does not work with variable length input, but there are two versions of the model, one which has been trained on 3 weeks of data and one which has been trained on 4 weeks of data. If the supplied input array contains between 3 and 4 weeks of data then it will be truncated down to the first three weeks. If the supplied input array contains more than 4 weeks of data then it will be truncated down to the first four weeks.

The predict function returns a list of predictions for each of the datasets it is given, where each prediction is a tuple containing the prediction itself, the lower bound and the upper bound.

import pysmeter.model as smeter

X = <code to make input array>

# Make the predictions
predictions = smeter.predict(X)

for htc, lower, upper in predictions:
    print(f"HTC: {htc} | Lower bound: {lower} | Upper bound: {upper}")

Here is a more illustrative example where we assume that we have two buildings whose data series are stored in the files data1.csv and data2.csv, where the csv files have headers indoor, outdoor, gas, elec.

import csv
import numpy as np
import pysmeter.model as smeter

def _read_data(file_path):
    """Reads data from file and returns 4 lists containing the data for each channel."""
    indoor, outdoor, gas, elec = [], [], [], []

    with open(file_path) as f:
        reader = csv.DictReader(f)
        for row in reader:
            indoor.append(float(row["indoor"]))
            outdoor.append(float(row["outdoor"]))
            gas.append(float(row["gas"]))
            elec.append(float(row["elec"]))

    return indoor, outdoor, gas, elec

x1 = _read_data("data1.csv")
x2 = _read_data("data2.csv")

# Put the data into a numpy array and make it the right shape
X = np.array([x1, x2]).transpose((0, 2, 1))

# Make the predictions
predictions = smeter.predict(X)

for htc, lower, upper in predictions:
    print(f"HTC: {htc} | Lower bound: {lower} | Upper bound: {upper}")

CLI

There is also a command line interface to the progamme which lets you run the SMETER model on data from a csv file.

The csv file must have four columns with readings for each of the four channels (average indoor temperature, outdoor temperature, gas kWh, elec kWh).

It will be assumed that each row corresponds to a single datetime and that time entries are 30 min apart. If a datetime column is present, it will do no harm, but it will be ignored by the program.

The expected column names are: indoor, outdoor, gas, elec.

They can be in any order. If your csv has different column names you can declare them using the -i, -o, -g, -e options (see example below).

Simple usage:

pysmeter /path/to/csv/file.csv

With optional csv column headers:

pysmeter /path/to/csv/file.csv -i 'Indoor temperature' -o 'Outdoor temperature'
pysmeter /path/to/csv/file.csv -g 'Gas'
pysmeter /path/to/csv/file.csv -e 'Electricity Usage (kWh)'

Sensor placement guidance

When placing the temperature sensors in the dwelling, it is important to adhere to the following guidance. Failure to do so will affect the accuracy of the HTC prediction.

  • Temperature sensors should be placed in as many rooms of the house as is feasible. The stairwell/landing can be considered to be a single room as it is one continuous thermal zone.
  • The ideal sensor position is the exact centre of the room, although this is likely to be impossible in most cases. The next best place is halfway up a wall, or placed on a bookcase, say.
  • Sensors should not be placed near windows, sources of heat or in places where they will receive direct sunlight. They should also not be placed in places where they are likely to be moved, knocked off a perch or mistaken for a toy by children.
  • It is recommended that you number each of the sensors, either with a sticker or with permanent marker, and make a map of the house showing all the sensor locations.
  • The outside sensor can be placed anywhere close to the house, e.g. the front or back garden. It must be placed within a Stevenson screen to shield it from direct sunlight.

For more detailed guidance, see https://smeter.cse.org.uk/guidance. We have also provided a template for noting sensor placement in MS Word format at https://smeter.cse.org.uk/guidance/SMETER-sensor-placement-template.docx.

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

pysmeter-1.0.1.tar.gz (7.0 kB view hashes)

Uploaded Source

Built Distribution

pysmeter-1.0.1-py3-none-any.whl (12.7 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page