Skip to main content

Eastron SDM Modbus parser library

Project description

sdm_modbus

sdm_modbus is a python library that collects data from Eastron SDM single- and three-phase kWh meters over Modbus RTU, Modbus TCP or Modbus UDP.

Supported devices:

Installation

To install, either clone this project and install using setup.py:

python3 setup.py install

or install the package from PyPi:

pip3 install sdm_modbus

Usage

The script example-tcp-udp.py provides a minimal example of connecting to and displaying all input and holding registers on a SDM120 over Modbus TCP or UDP. To display values as a JSON object, add --json.

usage: example-tcp-udp.py [-h] [--unit UNIT] [--json] [--udp] host port

positional arguments:
  host         Modbus TCP/UDP address
  port         Modbus TCP/UDP port

optional arguments:
  -h, --help         show this help message and exit
  --udp              Use Modbus UDP mode
  --timeout TIMEOUT  Connection timeout
  --framer FRAMER    Framer (rtu|socket|ascii|binary)
  --unit UNIT        Modbus device address
  --json             Output as JSON

Output:

SDM120(10.0.0.123:502, connectionType.TCP: timeout=1, retries=3, unit=0x1):

Input Registers:
    Voltage: 237.00V
    Current: 8.63A
    Power (Active): -1919.70W
    Power (Apparent): 2035.57VA
    Power (Reactive): -676.70VA
    Power Factor: -0.94
    Phase Angle: 0.00°
    Frequency: 50.00Hz
    Imported Energy (Active): 1551.37kWh
    Imported Energy (Active): 1335.69kWh
    Imported Energy (Reactive): 0.01kVAh
    Exported Energy (Reactive): 4362.14kVAh
    Total Demand Power (Active): 1668.02W
    Maximum Total Demand Power (Active): 3347.26W
    Import Demand Power (Active): 0.00W
    Maximum Import Demand Power (Active): 3347.26W
    Export Demand Power (Active): 1668.02W
    Maximum Export Demand Power (Active): 2109.45W
    Total Demand Current: 7.57A
    Maximum Total Demand Current: 14.97A
    Total Energy (Active): 2887.07kWh
    Total Energy (Reactive): 0.00kVAh

Holding Registers:
    Demand Time: 1s
    Demand Period: 60s
    Relay Pulse Width: 60ms
    Network Parity Stop: N-1
    Meter ID: 1
    Baud Rate: 9600
    P1 Output Mode: Export Energy (Active)
    Display Scroll Timing: 0s
    P1 Divisor: 0.001kWh/imp
    Measurement Mode: 0
    Pulse/LED Indicator Mode: Import + Export Energy (Active)

Connecting

If you wish to use Modbus TCP or UDP the following parameters are relevant:

host = IP or DNS name of your Modbus TCP gateway, required
port = TCP port of the Modbus TCP gateway, required
unit = Modbus device address, default=1, optional udp = Use Modbus UDP mode, default=False, optional framer = Modbus protocol, default=socket, optional

If you are using a Modbus RTU connection you can specify:

device = path to serial device, e.g. /dev/ttyUSB0, required
baud = baud rate of your SDM unit, defaults to factory default, optional
unit = Modbus device address, defaults to 1, optional

Connecting to the meter:

    >>> import sdm_modbus

    # SDM120 over Modbus TCP
    >>> device = sdm_modbus.SDM120(host="10.0.0.123", port=502)

    # SDM120 over Modbus UDP
    >>> device = sdm_modbus.SDM120(host="10.0.0.123", port=502, udp=True)

    # SDM630 over Modbus RTU
    >>> device = sdm_modbus.SDM630(device="/dev/ttyUSB0", baud=9600)

Test the connection:

    >>> device.connected()
    True

Printing the object yields basic device parameters:

    >>> device
    SDM120(10.0.0.123:502, connectionType.TCP: timeout=1, retries=3, unit=0x1):

Connecting to Multiple Devices

Re-using an existing RTU, TCP or UDP connection is possible by providing an already connected device as parent when creating a new instance. This may be necessary if the Modbus TCP/UDP gateway only accepts a limited number of connections, or you wish to address multiple RTU devices on the same bus. For example:

    # Connect to a SDM630 over Modbus TCP
    >>> device_1 = sdm_modbus.SDM630(host="10.0.0.123", port=502, unit=1)

    # Connect to a SDM630 using the existing connection
    >>> device_2 = sdm_modbus.SDM630(parent=device_1, unit=2)

Reading Registers

Reading a single input register by name:

    >>> device.read("voltage")
    236.89999389648438

Read all registers of a given registerType by calling read_all(). By default this polls all sdm_modbus.registerType.INPUT registers. Pass sdm_modbus.registerType.HOLDING to poll all holding registers.

    >>> device.read_all(sdm_modbus.registerType.INPUT)
    {
        "voltage": 238.60000610351562,
        "current": 7.59499979019165,
        "power_active": -1673.800048828125,
        "power_apparent": 1797.5904541015625,
        "power_reactive": -655.4000244140625,
        "power_factor": -0.9311425685882568,
        "phase_angle": 0.0,
        "frequency": 50.0,
        "import_energy_active": 1556.35595703125,
        "export_energy_active": 1345.9210205078125,
        "import_energy_reactive": 0.014999999664723873,
        "export_energy_reactive": 4376.02001953125,
        "total_demand_power_active": 1659.360107421875,
        "maximum_total_demand_power_active": 3347.26318359375,
        "import_demand_power_active": 0.0,
        "maximum_import_demand_power_active": 3347.26318359375,
        "export_demand_power_active": 1659.360107421875,
        "maximum_export_demand_power_active": 2109.4541015625,
        "total_demand_current": 7.531858921051025,
        "maximum_total_demand_current": 14.968546867370605,
        "total_energy_active": 2902.277099609375,
        "total_energy_reactive": 4376.03515625
    }

    >>> device.read_all(sdm_modbus.registerType.HOLDING)
    {
        "demand_time": 1,
        "demand_period": 60,
        "relay_pulse_width": 60,
        "network_parity_stop": 0,
        "meter_id": 1,
        "baud": 2,
        "p1_output_mode": 4,
        "display_scroll_timing": 0,
        "p1_divisor": 0,
        "measurement_mode": 0,
        "indicator_mode": 0
    }

Writing Registers

Writing to holding registers is also possible. Setting a new baud rate, for example:

    >>> device.write("baud", 2)
    WriteMultipleRegisterResponse (28,2)

You will need to enable setup mode on your device by pressing the setup button for 5 seconds, otherwise you will receive a Exception Response(134, 6, GatewayNoResponse) or similar.

Register Details

If you need more information about a particular register, to look up the units or enumerations, for example:

    >>> device.registers["voltage"]
        # address, length, type, datatype, valuetype, name, unit, batching
        (
            0,
            2,
            <registerType.INPUT: 1>,
            <registerDataType.FLOAT32: 11>,
            <class 'float'>,
            'Voltage',
            'V',
            1
        )

    >>> device.registers["p1_divisor"]
        # address, length, type, datatype, valuetype, name, unit, batching
        (
            63760,
            2,
            <registerType.HOLDING: 2>,
            <registerDataType.FLOAT32: 11>,
            <class 'int'>,
            'P1 Divisor',
            ['0.001kWh/imp', '0.01kWh/imp', '0.1kWh/imp', '1kWh/imp'],
            2
        )

Contributing

Contributions are more than welcome, especially testing on supported units, and adding other Eastron SDM units.

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

sdm_modbus-0.7.0.tar.gz (16.0 kB view details)

Uploaded Source

Built Distribution

sdm_modbus-0.7.0-py3-none-any.whl (14.8 kB view details)

Uploaded Python 3

File details

Details for the file sdm_modbus-0.7.0.tar.gz.

File metadata

  • Download URL: sdm_modbus-0.7.0.tar.gz
  • Upload date:
  • Size: 16.0 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/4.0.2 CPython/3.11.5

File hashes

Hashes for sdm_modbus-0.7.0.tar.gz
Algorithm Hash digest
SHA256 91573cbdd839423588cc60bf0e5f815ad9c7ce189775da9d3095e7c7f3bef81d
MD5 a707c59971aca222b54eec121011f2b5
BLAKE2b-256 3240e0afd478eb6cb58ea29d71fb9bac3f0e6819a4915b8d52cc316e67a5878d

See more details on using hashes here.

File details

Details for the file sdm_modbus-0.7.0-py3-none-any.whl.

File metadata

  • Download URL: sdm_modbus-0.7.0-py3-none-any.whl
  • Upload date:
  • Size: 14.8 kB
  • Tags: Python 3
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/4.0.2 CPython/3.11.5

File hashes

Hashes for sdm_modbus-0.7.0-py3-none-any.whl
Algorithm Hash digest
SHA256 7a99cb5c451585816998681d3c278039254ff024858fe9c3f3882cf71e7429e9
MD5 da0a23dec21c21b46725540871e191d3
BLAKE2b-256 1b060d1594d5ef7427cafe4c88a701e3b3ce4e76f30cbdac64781af064307c43

See more details on using hashes here.

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page