Skip to main content

Eastron SDM Modbus parser library

Project description

sdm_modbus

sdm_modbus is a python library that collects data from Eastron SDM single- and three-phase kWh meters over Modbus or ModbusTCP.

Supported devices:

  • SDM120
  • SDM630

Installation

To install, either clone this project and install using setuptools:

python3 setup.py install

or install the package from PyPi:

pip3 install sdm_modbus

Usage

The script example.py provides a minimal example of connecting to and displaying all input and holding registers on a SDM120 over ModbusTCP. To display values as a JSON object, add --json.

usage: example.py [-h] [--unit UNIT] [--json] host port

positional arguments:
  host         ModbusTCP address
  port         ModbusTCP port

optional arguments:
  -h, --help   show this help message and exit
  --unit UNIT  Modbus unit
  --json       Output as JSON

Output:

SDM120(10.0.0.123:502, unit=0x1):

Input Registers:
    Voltage: 237.00V
    Current: 8.63A
    Power (Active): -1919.70W
    Power (Apparent): 2035.57VA
    Power (Reactive): -676.70VA
    Power Factor: -0.94
    Phase Angle: 0.00°
    Frequency: 50.00Hz
    Imported Energy (Active): 1551.37kWh
    Imported Energy (Active): 1335.69kWh
    Imported Energy (Reactive): 0.01kVAh
    Exported Energy (Reactive): 4362.14kVAh
    Total Demand Power (Active): 1668.02W
    Maximum Total Demand Power (Active): 3347.26W
    Import Demand Power (Active): 0.00W
    Maximum Import Demand Power (Active): 3347.26W
    Export Demand Power (Active): 1668.02W
    Maximum Export Demand Power (Active): 2109.45W
    Total Demand Current: 7.57A
    Maximum Total Demand Current: 14.97A
    Total Energy (Active): 2887.07kWh
    Total Energy (Reactive): 0.00kVAh

Holding Registers:
    Demand Time: 1s
    Demand Period: 60s
    Relay Pulse Width: 60ms
    Network Parity Stop: N-1
    Meter ID: 1
    Baud Rate: 9600
    P1 Output Mode: Export Energy (Active)
    Display Scroll Timing: 0s
    P1 Divisor: 0.001kWh/imp
    Measurement Mode: 0
    Pulse/LED Indicator Mode: Import + Export Energy (Active)

Examples

If you wish to use ModbusTCP the following parameters are relevant:

host = IP or DNS name of your ModbusTCP gateway, required
port = listening port of the ModbusTCP gateway, required
unit = Modbus device id, default=1, optional

While if you are using a serial Modbus connection you can specify:

device = path to serial device, e.g. /dev/ttyUSB0, required
baud = baud rate of your SDM unit, defaults to product default, optional
unit = Modbus unit id, defaults to 1, optional

Connecting to the meter:

    >>> import sdm_modbus

    # SDM120 over ModbusTCP
    >>> device = sdm_modbus.SDM120(host="10.0.0.123", port=502)

    # DM630 over Modbus RTU
    >>> device = sdm_modbus.SDM630(device="/dev/ttyUSB0", baud=9600)

Test the connection:

    >>> device.connected()
    True

Printing the class yields basic device parameters:

    >>> device
    SDM120(10.0.0.123:502, unit=0x1)

Reading a single input register by name:

    >>> device.read("voltage")
    236.89999389648438

Read all input registers by passing the sdm_modbus.registerType.INPUT enum to read_all(). Leave this blank to read both INPUT and HOLDING registers:

    >>> device.read_all(sdm_modbus.registerType.INPUT)
    {
        "voltage": 238.60000610351562,
        "current": 7.59499979019165,
        "power_active": -1673.800048828125,
        "power_apparent": 1797.5904541015625,
        "power_reactive": -655.4000244140625,
        "power_factor": -0.9311425685882568,
        "phase_angle": 0.0,
        "frequency": 50.0,
        "import_energy_active": 1556.35595703125,
        "export_energy_active": 1345.9210205078125,
        "import_energy_reactive": 0.014999999664723873,
        "export_energy_reactive": 4376.02001953125,
        "total_demand_power_active": 1659.360107421875,
        "maximum_total_demand_power_active": 3347.26318359375,
        "import_demand_power_active": 0.0,
        "maximum_import_demand_power_active": 3347.26318359375,
        "export_demand_power_active": 1659.360107421875,
        "maximum_export_demand_power_active": 2109.4541015625,
        "total_demand_current": 7.531858921051025,
        "maximum_total_demand_current": 14.968546867370605,
        "total_energy_active": 2902.277099609375,
        "total_energy_reactive": 4376.03515625
    }

    >>> device.read_all(sdm_modbus.registerType.HOLDING)
    {
        "demand_time": 1,
        "demand_period": 60,
        "relay_pulse_width": 60,
        "network_parity_stop": 0,
        "meter_id": 1,
        "baud": 2,
        "p1_output_mode": 4,
        "display_scroll_timing": 0,
        "p1_divisor": 0,
        "measurement_mode": 0,
        "indicator_mode": 0
    }

If you need more information about a particular register, to look up the units or enumerations, for example:

    >>> device.registers["voltage"]
        # address, length, type, datatype, valuetype, name, unit
        (0, 2, <registerType.INPUT: 1>, <registerDataType.FLOAT32: 11>, <class 'float'>, 'Voltage', 'V'))

    >>> device.registers["p1_divisor"]
        (
            63760, 2, <registerType.HOLDING: 2>, <registerDataType.FLOAT32: 11>, <class 'int'>, 
            'P1 Divisor', ['0.001kWh/imp', '0.01kWh/imp', '0.1kWh/imp', '1kWh/imp']
        )

Writing to holding registers is also possible. Setting a new baud rate, for example:

    >>> device.write("baud", 2)
    WriteMultipleRegisterResponse (28,2)

Remember: you will need to enable setup mode on your device by pressing the setup button for 5 seconds. You will receive a Exception Response(134, 6, GatewayNoResponse) or similar, otherwise.

Contributing

Contributions are more than welcome, especially testing on supported units, and adding other Eastron SDM units.

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

sdm_modbus-0.3.0.tar.gz (9.4 kB view hashes)

Uploaded Source

Built Distribution

sdm_modbus-0.3.0-py3-none-any.whl (7.6 kB view hashes)

Uploaded Python 3

Supported by

AWS AWS Cloud computing and Security Sponsor Datadog Datadog Monitoring Fastly Fastly CDN Google Google Download Analytics Microsoft Microsoft PSF Sponsor Pingdom Pingdom Monitoring Sentry Sentry Error logging StatusPage StatusPage Status page