spectarf
Monte Carlo angular response functions (ARFs) and point-spread functions (PSFs) for parallel-hole SPECT, for reconstruction in PyTomography.
Status: pre-release (0.0.1.dev0). The package is being built; the API shown below is under construction and will change. It is a research tool, not a medical device.
What it is
PyTomography's default model of the collimator and detector blur is a Gaussian whose width grows linearly with distance. That model has no septal penetration, no collimator scatter, no lead X-rays and no downscatter from higher-energy lines, all of which shape the response at medium and high photon energies: Lu-177 at 208 keV, In-111, I-131, and the Pb-212 and Ac-225 decay chains.
spectarf computes the response instead, by photon transport through the collimator and detector. For one photon energy and one energy window, the ARF is the probability that a photon arriving at the collimator face in direction (θ, φ), at a uniformly random point of the hole lattice, is detected in the window with its energy-weighted Anger centroid displaced by (dx, dy) from where it entered. The package then turns the ARFs of an isotope's emission lines into a 2D kernel at every plane distance of a reconstruction.
- One dense ARF per emission line and energy window, over (θ, φ, dx, dy). Every window a reconstruction uses (the photopeak and its TEW side windows) is scored from the same photon histories in one pass, with the window's exact bounds; the energy resolution enters as each event's exact acceptance in each window.
- User-set bins, non-uniform where the response is sharp.
suggest_gridproposes a grid and a validator checks it. - A cache keyed on every input that changes the transport or the scoring. An ARF is reused only when all of them match; a window that differs by 0.1 keV is a new ARF. The lattice orientation and the intrinsic blur act after scoring, so they are written into the returned ARF rather than keyed.
psf_from_arf: ARFs and line yields in, one kernel per plane distance out, at the reconstruction's own pixel size, in counts per decay. No Gaussian assumption, no separability, no symmetrisation: the six-fold septal-penetration star is kept. It needs only numpy and torch.- TEW-consistent kernels.
tew_combineforms the combination of photopeak and side-window ARFs that matches what triple-energy-window scatter correction subtracts from the data. - The intrinsic blur is counted once. A vendor's NEMA intrinsic resolution already contains the crystal's own positional spread, which the transport models; the package solves for the remaining light-centroid width and applies only that.
- Geometry in SIMIND's parameterisation: a collimator from SIMIND's collimator database by exact code, from a scanner preset that cites the vendor's datasheet, or from explicit numbers; an aluminium cover; a NaI(Tl) crystal; a homogeneous backscatter slab.
- Isotopes as line lists of (energy, photons per decay).
Nuclide.from_ddepbuilds one from the evaluated data of DDEP, the Decay Data Evaluation Project, including X-rays and decay chains. - Transport engines behind one interface:
fused-cudaon NVIDIA GPUsfused-cpu(the same kernel compiled for CPU cores) andtorchon any device torch supports. See docs/hardware.md. - Checks:
simulate_point_sourceruns the same transport from a point source, andcompare_psfoverlays the result withpsf_from_arf's kernel, tails included.
What it is not
- Not a Monte Carlo forward projector or a Monte Carlo reconstruction. The kernels describe photons that were not scattered in the patient; the ARFs have no continuous energy axis, which a model of patient scatter would need. Patient scatter remains the job of TEW, estimated from the measurement.
- Not for fan-beam, cone-beam, slant-hole or pinhole collimators.
- Not for pixelated CZT cameras, whose response needs a model of pixel collection and charge sharing rather than an Anger centroid.
- Not for bremsstrahlung imaging (Y-90, P-32): DDEP lists no continuous photon spectrum.
- Not an extension of SPECTPSFToolbox. It is independent of it.
- No graphical interface.
Installation
spectarf is not on PyPI yet. Until the first release, install it from a
clone of this repository with pip install -e .. Once released:
pip install spectarf # the fused-cpu and torch engines, any platform
pip install "spectarf[cuda]" # adds the fused-cuda engine for NVIDIA GPUs
pip install "spectarf[pytomography]" # adds PyTomography, for ArbitraryKernelPSFTransform
- Python 3.10 or later.
- The
[cuda]extra installs numba-cuda with NVIDIA's pip CUDA wheels, so no CUDA toolkit ornvccis needed; an NVIDIA driver is. - For any GPU, install torch first by PyTorch's own instructions (CUDA, ROCm, Apple MPS or Intel XPU), then install spectarf.
Quick start
API under construction. The names follow the package's current interface contract and may change before the first release.
import numpy as np
from spectarf import DetectorStack
from spectarf.generate import generate_arf
from spectarf.geometry.presets import response_from_preset
from spectarf.nuclides import Nuclide
from spectarf.psf import psf_from_arf, tew_combine
# A scanner preset: collimator, crystal and NEMA resolutions from the vendor's
# datasheet (each value cited), in SIMIND's stack: 1 mm aluminium cover,
# NaI(Tl) crystal, homogeneous backscatter slab. Any field can be overridden,
# and a stack can also be built from a SIMIND database code or explicit numbers.
stack = DetectorStack.from_preset("NM670Pro-MEGP-3/8")
response = response_from_preset("NM670Pro-MEGP-3/8")
# Lu-177: photopeak window and its TEW side windows, in keV, as declared.
windows = {"P": (187.2, 228.8), "L": (166.4, 187.2), "U": (228.8, 249.6)}
lines = Nuclide.from_ddep("Lu-177").lines_for(windows, response.energy)
# One ARF per line and window. All windows are scored in one transport pass per
# line; the grid is suggested per line (or pass your own ArfGrid); every result
# is cached under a key built from all of these inputs.
arfs = generate_arf(stack, response, lines, windows)
# arfs["P"] is a list of (Arf, yield per decay) terms, one per emission line.
distances_mm = np.arange(2.4, 400.0, 4.8) # plane distances to the face
k_peak = psf_from_arf(arfs["P"], distances_mm, pixel_mm=4.8, kernel_shape=(63, 63))
k_tew = psf_from_arf(tew_combine(arfs, windows), distances_mm,
pixel_mm=4.8, kernel_shape=(63, 63))
# k_*: torch tensors (n_distances, n_u, n_v) in counts per decay of the parent
# per pixel; u is the projection's transaxial axis, v its axial axis.
The kernels go into PyTomography's system matrix through an arbitrary-kernel
PSF transform, which applies one 2D kernel per plane by FFT and the true back
projection in backward. It computes the kernels itself, at the plane
distances of every view of the acquisition, from the same terms:
from pytomography.projectors.SPECT import SPECTSystemMatrix
from spectarf.psf import ArbitraryKernelPSFTransform
psf = ArbitraryKernelPSFTransform(tew_combine(arfs, windows)) # or arfs["P"]
system_matrix = SPECTSystemMatrix(
obj2obj_transforms=[attenuation_transform, psf], # attenuation as usual
proj2proj_transforms=[],
object_meta=object_meta, proj_meta=proj_meta)
# psf.clipped_fraction: per distance, the share of a TEW kernel's tail clipped
# at zero (OSEM needs a non-negative system matrix).
This is a reference implementation tested against PyTomography 3.4.0; how PyTomography v4 takes it over is being agreed with its maintainers.
Limits
The full list is in docs/limitations.md. In short:
- The PSF is for photons not scattered in the patient; TEW's own errors in the patient remain.
- Window bounds are taken as declared, as true deposited energy. A DICOM window is on the camera's console energy axis; where that axis is offset or scaled from true energy, the modelled window is misplaced by the same amount. Enter corrected bounds if you know the offset.
- The rear of the camera is a homogeneous slab, as in SIMIND. Above about 500 keV, where backscatter from the photomultipliers and the rear shielding forms peaks in the window, this is the model's weakest part.
- The intrinsic blur and the energy resolution are modelled as Gaussian.
- PyTomography applies attenuation along the ray normal to the detector, separately from the PSF, so oblique paths through the patient are approximated. That is a property of the analytic system matrix, not of the kernel.
Data sources and their licensing
| Data | Source | Status |
|---|---|---|
| Collimator records | spectarf's own specification table, collimators.csv: the dimensions listed in SIMIND 9.0's collimator database collim.col (M. Ljungberg, Lund University), converted to mm |
Bundled. The SIMIND file itself is not copied; a user's own collim.col ($SMC_DIR) or PyTomography's bundled copy can be read instead. |
| Collimator cross-check | OpenGATE's public SPECT head models (LGPL-3.0) | Published dimensions, with their source, are used only to audit the database records; no OpenGATE code or file is redistributed. |
| Scanner presets | Vendors' public datasheets | Each preset cites its source. |
The backscatter slab's pmt material |
SIMIND 9.0's pmt.cr5: a borosilicate glass, composition by weight and density as the file states them |
Used as stated, with the source recorded. |
| Emission lines | DDEP recommended data, published by LNHB (CEA, France) through Nucléide-Lara | Freely available. The package ships DDEP's values, transcribed unmodified, for Lu-177, Tc-99m, In-111, I-131, Pb-203, Pb-212 and Ac-225 with their chains (src/spectarf/data/ddep/), each with its evaluation reference. Any other line list can be given by hand. See docs/nuclides.md. |
| Photon cross sections | Up to 350 keV, Elam, Ravel and Sieber (2002) through xraydb; above, NIST XCOM 3.1; coherent form factors (Hubbell et al. 1975) and anomalous scattering factors from EPDL97 | Public data. The bundled table is generated by tools/gen_xs_stack.py, and its provenance is stored with it. |
Validation
Every check uses analytic results, our own runs of public codes, or public data. They are being built with the package, and their results will be reported in the documentation as they pass.
- Transport: engines against each other, bin by bin, as a statistical test; narrow-beam transmission through lead and tungsten against Beer-Lambert; the geometric efficiency of a hexagonal collimator against the analytic formula.
- Generation: invariance to where the lattice cell is anchored, and robustness to the binning, from one set of photon histories scored into different grids.
psf_from_arf: sensitivity preserved through interpolation and area rebinning; the low-energy FWHM against the geometric resolution.- End to end: a point source simulated directly through the same
transport against
psf_from_arf's kernel, out to the tails (Ac-225's 440 keV line on medium- and high-energy collimators, Tc-99m on a LEHR collimator). - Other codes: SIMIND 9.0 point sources in air, compared per collimator component (geometric and septal penetration) in validation/simind/; GATE for the full response, collimator scatter included.
- Reconstruction: a public phantom with the Gaussian PSF and with the ARF PSF, both with TEW (tutorial 3).
Documentation
The documentation is in docs/ and will be published on Read the Docs. Tutorial outlines are in tutorials/. Where development stands, and the open work: docs/STATUS.md.
Citation
spectarf has not been released or published yet. A citation, and a
CITATION.cff file, will come with the first release. In the meantime,
please cite this repository and PyTomography:
L. A. Polson et al., PyTomography: A python library for medical image reconstruction, SoftwareX 29 (2025) 102020.
Contributing and licence
See CONTRIBUTING.md. spectarf is released under the MIT licence (LICENSE). Data from external sources keep their own terms, listed above.
Metadata
Release files for spectarf 0.1.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| spectarf-0.1.0.tar.gz | 1.4 MB | Without provenance | Details for spectarf-0.1.0.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| spectarf-0.1.0-py3-none-any.whl | Python 3 | none | any | Details for spectarf-0.1.0-py3-none-any.whl |
Total release size: 2.8 MB
Release files / spectarf-0.1.0.tar.gz
| Download URL | spectarf-0.1.0.tar.gz |
|---|---|
| Size | 1.4 MB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
6a1c99c34dc898d2fd33a24d8e5d33a8fc4fa3be299edbbc7d2d06e3005a068e
|
|
BLAKE2b-256 checksum How to use checksums |
ce9ab187cc3324acfa5a7c824d98f94945c9a85bf9ca9404de3b7ddcbe26ea7f
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.11.9
|
Release files / spectarf-0.1.0-py3-none-any.whl
| Download URL | spectarf-0.1.0-py3-none-any.whl |
|---|---|
| Size | 1.4 MB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
5582d674c571eacc36b764a61ad13746fc42c520f26c7b41fee7c36893a1b009
|
|
BLAKE2b-256 checksum How to use checksums |
fac7015914896fab55278adca44752077774d322e79c958528e613cfb5b86bd6
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.11.9
|
Security for spectarf 0.1.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
No provenance found
None of the files in this release were uploaded with provenance metadata.
A note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.