This release is a pre-release and may not be stable for production use.
uModbus
uModbus or (μModbus) is a pure Python implementation of the Modbus protocol as described in the MODBUS Application Protocol Specification V1.1b3. uModbus implements both a Modbus client (or master in Modbus language) and a Modbus server (or slave). The “u” or “μ” in the name comes from the the SI prefix “micro-”. uModbus is very small and lightweight. The source can be found on GitHub. Documentation is available at Read the Docs.
Quickstart
Creating a Modbus server is easy:
#!/usr/bin/env python
# scripts/examples/simple_data_store.py
import logging
from socketserver import TCPServer
from collections import defaultdict
from umodbus import get_server, RequestHandler, conf
from umodbus.utils import log_to_stream
# Add stream handler to logger 'uModbus'.
log_to_stream(level=logging.DEBUG)
# A very simple data store which maps addresss against their values.
data_store = defaultdict(int)
# Enable values to be signed (default is False).
conf.SIGNED_VALUES = True
TCPServer.allow_reuse_address = True
app = get_server(TCPServer, ('localhost', 502), RequestHandler)
@app.route(slave_ids=[1], function_codes=[3, 4], addresses=list(range(0, 10)))
def read_data_store(slave_id, function_code, address):
"""" Return value of address. """
return data_store[address]
@app.route(slave_ids=[1], function_codes=[6, 16], addresses=list(range(0, 10)))
def write_data_store(slave_id, function_code, address, value):
"""" Set value for address. """
data_store[address] = value
if __name__ == '__main__':
try:
app.serve_forever()
finally:
app.shutdown()
app.server_close()
Doing a Modbus request requires even less code:
#!/usr/bin/env python
# scripts/examples/simple_tcp_client.py
import socket
from umodbus import conf
from umodbus.client import tcp
# Enable values to be signed (default is False).
conf.SIGNED_VALUES = True
sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
sock.connect(('localhost', 502))
# Returns a message or Application Data Unit (ADU) specific for doing
# Modbus TCP/IP.
message = tcp.write_multiple_coils(slave_id=1, starting_address=1, values=[1, 0, 1, 1])
# Response depends on Modbus function code. This particular returns the
# amount of coils written, in this case it is.
response = tcp.send_message(message, sock)
sock.close()
Features
The following Modbus functions have been implemented:
01: Read Coils
02: Read Discrete Inputs
03: Read Holding Registers
04: Read Input Registers
05: Write Single Coil
06: Write Single Register
15: Write Multiple Coils
16: Write Multiple Registers
Other featues:
Support for signed and unsigned register values.
Roadmap
uModbus is far from complete. The next, unordered list shows what is going to be implemented in the future:
Support for all Modbus functions
Modbus RTU
Use asyncio for handling of requests
Other Modbus ‘flavours’, so uModbus is able to handle 32 bit values.
License
uModbus software is licensed under Mozilla Public License. © 2015 Advanced Climate Systems.
Metadata
Release files for uModbus 0.6.0a2
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| uModbus-0.6.0a2.tar.gz | 22.1 kB | Without provenance | Details for uModbus-0.6.0a2.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| uModbus-0.6.0a2-py2.py3-none-any.whl | Python 3, Python 2 | none | any | Details for uModbus-0.6.0a2-py2.py3-none-any.whl |
Total release size: 49.0 kB
Release files / uModbus-0.6.0a2.tar.gz
| Download URL | uModbus-0.6.0a2.tar.gz |
|---|---|
| Size | 22.1 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
6d008c60faa1938f9f4d6c3bce37fcb7b2a8985132e64b37e4e7e0c019cda445
|
|
BLAKE2b-256 checksum How to use checksums |
b50a28b4c56e4d2b9ade5df9a2a5419dbc342f99449b69ac82e8d027cd016086
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
Release files / uModbus-0.6.0a2-py2.py3-none-any.whl
| Download URL | uModbus-0.6.0a2-py2.py3-none-any.whl |
|---|---|
| Size | 26.9 kB |
| Tags | Python 2 Python 3 |
|
SHA-256 checksum How to use checksums |
e2a8cb3cb7074151f6eaac5bdff0d3333d588735b4efef3c380acaa59b7731af
|
|
BLAKE2b-256 checksum How to use checksums |
61ad2a5c3f6f90c194e21333b815efe005472fe229044fab62bb3b254aeea3cc
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
Security for uModbus 0.6.0a2
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
No provenance found
None of the files in this release were uploaded with provenance metadata.
A note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.