Drayton Wiser Hub API Async v1.7.4
This repository contains a simple API which queries the Drayton Wiser Heating sysystem used in the UK.
The API functionality provides the following functionality to control the wiser heating system for 1,2 and 3 channel heat hubs The API also supports Smart Plugs and initial basic functionality for Shutter and Lights
Requirements
Requires a minimum of Python v3.12
Installation
1. Find your HeatHub Secret key
Reference https://it.knightnet.org.uk/kb/nr-qa/drayton-wiser-heating-control/#controlling-the-system
-
Press the setup button on your HeatHub, the light will start flashing Look for the Wi-Fi network (SSID) called ‘WiserHeatXXXXXX’ where XXXXXX is last 6 digits of the MAC address
-
Connect to the network from a Windows/Linux/Mac/Android/iPhone machine
-
Execute the secret url :-)
- Open a browser to url
http://192.168.8.1/secret
This will return a string which is your system secret, store this somewhere. If you are running the test script simply put this value , with the ip address of the hub, in your wiserkeys.params
- Open a browser to url
-
Press the setup button on the HeatHub again and it will go back to normal operations
-
Copy the secret and save it somewhere.
3. Find Your HEATHUB IP
Using your router, or something else, identify the IP address of your HeatHub, it usually identifies itself as the same ID as the WiserHeatXXXXXX
Alternatively see the test_api_discovery.py file for how to use the api to discover your hub
4. Add values in you params.py to run tests
Create a file called params.py and place two lines, one with the wiser IP or hostname and the other with the secret key. e.g.
HOST="192.168.0.22"
KEY="ABCDCDCDCCCDCDC"
5. Run the sample
To help understand the api simply look at the test sample code tests/test_api_properties.py, tests/test_api_methods.py or tests/test_api_discovery.py and the fully commented code.
6. Documentation
Documentation available in info.md in the docs directory and within comments in the code
Changelog
v1.7.4
- Added: optional scheduled lower-temperature provider for Passive Mode
- Added: EVSE device support
- Added: Button panel battery status
- Added: Support for the
OffAfter2sLED indicator mode - Fix: Refine room heating state for OpenTherm systems
v1.7.3
- Fix: Set min f/w version of 4.42.22 for https on gen2 hubs
v1.7.0
- Added https support for v2 hubs -> required for some commands
v1.6.7
- Added: provide battery level percentage is no battery voltage data
v1.6.6
- Added: support SSL redirect on hub for future firmware
v1.6.5
- Fix: improve status handling of hot water for hw climate mode
v1.6.4
- Fix: fix issue of default extra config values not being provided
v1.6.3
- Fix: fix error in temp validator from websocket schedule data that errored if a slot was set to off
v1.6.2
- Refactor: Removed unused imports causing error in python3.13
- Fix: Add equipment data during deviuce build process
v1.6.1
- Added: support for temperature and humidity sensors
v1.6.0
- Refactored how devices are enumerated
- BREAKING CHANGE - threshold sensor is now a device attribute and not its own device
- Added: support for 2 gang light switches
- Added: support for threshold and UI configuration as device attributes
- Added: support for PTC devices
- Added: UUID now exists for all devices (for future use)
- Added: New attributes and stored extra config for Hot Water to support HW Climate automation in HA integration
- Added: Control of interacts with room climate for binary sensors
v1.5.19
- Fixed error when BoilerInterface does not provide DeviceId field
- Fixed not supporting non ascii characters in schedule names
- Added ButtonPanel device support
v1.5.18
- Better handle client response exeption and fit into retry routing
v1.5.17
- Fixed error setting opentherm endpoint for fw above 4.32.46
- Added support for CFMT devices
v1.5.16
- Added support for v2 opentherm endpoint for fw above 4.32.46
v1.5.15
- Added additonal functions for v2 hub lights, equipments etc
- Added support for WindowDoor sensors
- Added support for Boiler Interface device
v1.5.14
- Fix presets not using defined boost temp
- Set return value of energy sensors to None if not provided by hub
- Updated headers for hub query
v1.5.13
- Updates to support v2 hub functions - @LGO44
- Add connection timeout to new retry function
- Increase http timeout from 10s to 20s
v1.5.12
- Improve performance of hub read and retries
- Fix error is no status endpoint
v1.5.11
- Improve error management
- Add additional debug logging
v1.5.10
- Add retry routine to prevent hub response errors
v1.5.9
- Force schedules endpoint to use http/1.0
v1.5.8
- Handle chunked encoding if sent by the hub
v1.5.7
- Fixed issue whereby lower target temp for passive mode was not being set correctly
- Added support for smoke alarm
v1.5.6
- Added improved error handling for json decode errors
v1.5.5
- Added addtional v2 hub attributes and switches
v1.5.4
- Fixed issue whereby json conversion errors due to control characters in string
v1.5.2
- Revert to aiohttp and fix errors with v3.9.x that caused move to httpx
v1.5.1
- Fix nuances with httpx
v1.5.0
- Move to httpx instead of aiohttp
v1.4.0
- Add PowerTagE support
- Add new v2 hub cloud parameters
- Add new v2 hub capabilities info
- Add v2 hub equipment data to relevant devices
- Add tilt support for shutters
- Fix issue where non ASCII chars removed
v1.3.9
- Fix for hub firmware bug whereby Away Mode Affects HotWater is turned off when cancelling overrides if no overrides exist.
v1.3.8
- Correct relative modulation level opentherm parameter magnitude
v1.3.7
- Amend battery to return None for voltage and percent if battery data not present
1.3.6
- Add new status class
- Fix error if passive mode room device offline
v1.3.5
- Correct async error in extra_config
v1.3.4
- Current temperature now returns none for room if TRV signal lost.
v1.3.3
- Fixed issue in passive mode so that it works with 3 channel hub and different rooms on different channels
v1.3.2
- Fixed issue ot maintaining some parameters after hub update
- Improved handling of extra config json errors
- Amended current_target_temp to use DisplayedSetPoint instead of CurrentSetPoint as this displays incorrectly in Eco mode
1.3.1
- Away mode overrides passive mode functions
1.3.0
- Rework passive mode functionality (may break previous code if using passive mode)
1.2.2
- Improve logic defining is_passive_mode property
1.2.1
- Code refactoring
- Added is_passive_mode property
- Corrected bug in passive mode automation to determine target temp
1.2.0
- Breaking Change - changes to passive mode from on or off to disabled, passive manual and passive follow schedule
- Support boost in passive mode
- Add additional opentherm parameters
- Fix not clearing overrides when enabling passive mode
1.1.1
- Fix issue setting on/off schedule - issue #349
1.1.0
- Added room passive mode automation control
1.0.2
- Fixed error in boost_all_rooms using old temp validation type (no longer supported)
- Fixed error in validating temps from yaml file
1.0.1
- Added endpoint parameter to set_opentherm_parameter
1.0.0
- Moved to stable build version
- Amended timeout error text
- Improved error handling for setting schedules
- Added temp sensor support for heating actuator
- Added support for network diagnostics
- Added support for non standard port
- Add boiler parameters to opentherm
- Support setting opentherm parameters
0.1.8
- Add url to exception messages
- Fix for unicode decode error
0.1.7
- Fixed error intiallising WiserUFHController class
- Made python3.9 compatible
0.1.6
- Remove debuggin print lines
- Remove session close on endpoint error
0.1.5
- Add ALL as special day option in schedule file for setting schedules from file
0.1.4
- Fix incorrect id used for schedule assignment in electrical devices
0.1.3
- Fixed issue in schedule.get_by_name
0.1.2
- Fixed calling wrong enpoint id for lights and shutters
0.1.0
- Initial asyncio release
Metadata
Release files for aioWiserHeatAPI 1.7.4
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | |
|---|---|---|---|---|
| aiowiserheatapi-1.7.4.tar.gz | 67.7 kB | Without provenance | Details |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Reset |
|---|---|---|---|---|
| aiowiserheatapi-1.7.4-py3-none-any.whl | Python 3 | none | any | Details |
Total release size: 153.2 kB
Release files / aiowiserheatapi-1.7.4.tar.gz
| Download URL | aiowiserheatapi-1.7.4.tar.gz |
|---|---|
| Size | 67.7 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
16120cb469bc538eb0a7085ffe15524c5230bce3b49ed2a0752b5704973ec035
|
|
BLAKE2b-256 checksum How to use checksums |
b9cf6c75ca2cd5b4c02e1e474e90c45453a602a799b1d7e1e7d9918e17783c2c
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/6.2.0 CPython/3.9.25
|
Release files / aiowiserheatapi-1.7.4-py3-none-any.whl
| Download URL | aiowiserheatapi-1.7.4-py3-none-any.whl |
|---|---|
| Size | 85.5 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
26485bbaa79c5eeb954296f0f2cb3591fe2c95869c358e2b7e001a410b9431b7
|
|
BLAKE2b-256 checksum How to use checksums |
f5039086fb6fff7f2d0f05719e4021fe9d3221cd8a149fcec567c6c1879f0bfe
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/6.2.0 CPython/3.9.25
|
Security for aioWiserHeatAPI 1.7.4
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
No provenance found
None of the files in this release were uploaded with provenance metadata.
A note on package security