Digital Twin infrastructure for modern energy systems.

DER Twin is a lightweight simulator for Distributed Energy Resources (DER) — BESS, PV inverters, CHP units, energy meters, and grid models — exposed via Modbus TCP and Modbus RTU. Use it for EMS development, protocol testing, integration validation, and control algorithm sandboxing without touching real hardware.


⚡ Quickstart

Option A — pip install

pip install dertwin

Bring your own site config and register maps:

dertwin -c path/to/your/config.json

You should see:

INFO | Building site: my-site
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Simulation engine started | step=0.100s

The simulator is now accepting Modbus TCP connections on the ports defined in your config.

Option B — Run from source

git clone https://github.com/AlexSpivak/dertwin.git
cd dertwin
python -m venv .venv && source .venv/bin/activate
pip install -e .
python -m dertwin.main -c configs/simple_config.json

Option C — Run with Docker

git clone https://github.com/AlexSpivak/dertwin.git
cd dertwin
python generate_compose.py configs/simple_config.json
docker compose up --build

generate_compose.py reads the config and generates a docker-compose.yml with the correct ports automatically. No manual port configuration needed. For mixed-protocol configs with RTU, see Docker with RTU below.


🔌 Connect an EMS

With the simulator running, start the example EMS from a second terminal:

cd examples
python main_simple.py

You'll see the EMS connecting over Modbus and cycling the BESS between 40–60% SOC:

[EMS] Connected to BESS
[EMS] Starting in CHARGE mode
[EMS] STATUS=1 | SOC= 42.30% | P=  -20.00 kW | MODE=charge
[EMS] STATUS=1 | SOC= 44.10% | P=  -20.00 kW | MODE=charge
...
[EMS] Reached 60% → switching to DISCHARGE

For a full multi-device site (dual BESS + PV + CHP + energy meter + external models):

python -m dertwin.main -c configs/full_site_config.json
# in another terminal:
python examples/main_full.py

You'll see the CHP go through its realistic startup sequence (~2 minutes) before reaching RUNNING and dispatching power, while the BESS units cycle and the energy meter aggregates the full site balance.

For a mixed-protocol site (BESS on TCP + PV and meter on RTU), see Mixed Protocol Example below.


🔁 Dynamic Asset Membership

In addition to config-driven site definitions, DERTwin's SiteController supports adding and removing assets at runtime. Use this for scenario scripts ("at t=300s, a new PV inverter comes online"), live demos, and EMS-driven sites where the asset roster is decided by an external controller.

from dertwin.controllers.site_controller import SiteController
import asyncio

# Build an empty site
site = SiteController({
    "site_name": "demo",
    "step": 0.1,
    "real_time": True,
    "register_map_root": "configs/register_maps",
    "assets": [],
})
site.build()
asyncio.create_task(site.start())

# Add an asset live — protocol server starts immediately, site power model picks it up next tick
await site.add_asset({
    "asset_id": "bess-01",
    "type": "bess",
    "ip": "127.0.0.1",
    "port": 55001,
    "unit_id": 1,
    "capacity_kwh": 200.0,
    "initial_soc": 50.0,
})

# ...later, remove it
await site.remove_asset("bess-01")

Key properties:

  • The site power model captures device lists by reference, so dynamically added generators show up in the energy meter's grid balance on the next tick — no rebuild required.
  • add_asset is idempotent: re-registering an existing asset_id is a no-op.
  • remove_asset cancels the protocol task and shuts down the server cleanly; the engine keeps running for the remaining assets.
  • See dertwin/controllers/README.md for the full API and the two supported configuration shapes (legacy protocols: [...] for multi-protocol use, flat spec for single-TCP-endpoint runtime use).

🧱 Features

  • Async Modbus TCP and RTU servers built on pymodbus
  • Mixed-protocol support — TCP and RTU devices on the same site
  • Full 16-bit Modbus address space on all four datastores (discrete inputs, coils, input registers, holding registers)
  • Per-register function code routing — FC02 discrete inputs for binary flags, FC03/04 for analog telemetry
  • Per-register endianness — big-endian default, little-endian for Sungrow/Carlo Gavazzi-style devices
  • Realistic CHP simulation — MWM TEM Evolution-compatible state machine, configurable startup timings, thermal physics, heat output
  • Config-driven site topology — add devices by editing JSON
  • Runtime asset management — add_asset / remove_asset for live scenario scripting and EMS-driven rosters
  • Hard SOC limits on BESS assets — SOC lands exactly on the limit, then power reads zero while the setpoint stays as written
  • Optional SOC persistence across restarts
  • Battery thermal management — a managed container holds the cells inside a setpoint band, so a cold site keeps full capability; configurable temperature derate curve and optional HVAC auxiliary draw on the meter
  • Location- and date-aware clear-sky irradiance — correct sunrise, sunset and seasonal peak for any latitude and day of the year
  • Stochastic cloud cover with persistent day-to-day weather regimes — seeded, a date's weather is reproducible per date, so restarts do not replay the same sky
  • Plane-of-array irradiance for tilted, oriented PV arrays, with DC/AC ratio and inverter clipping
  • Irradiance from a CSV, for replaying measured data
  • Stochastic site load — daily profile, weekday/weekend factor, slow mean-reverting drift keyed on simulated time, and fast noise, all seedable
  • Ambient temperature, grid frequency, and grid voltage models
  • Multi-device support across independent ports
  • External model events (voltage sags, frequency deviations)
  • Simulation start time control (start_time_h) — start at noon, peak load, etc.
  • Docker support with auto-generated Compose files and RTU-over-TCP bridging
  • Deterministic simulation with seeded random models
  • Fully tested with pytest

📦 Repo Structure

dertwin/
├── configs/
│   ├── register_maps/              # Modbus register definitions (YAML)
│   ├── simple_config.json          # Single BESS — good starting point
│   ├── demo_config.json            # BESS + PV + meter
│   ├── full_site_config.json       # BESS + BESS + PV + CHP + meter + external models
│   ├── mixed_protocol_config.json  # BESS (TCP) + PV (RTU) + meter (RTU)
│   ├── stockholm_site_config.json  # Northern Europe, 59.33 N — clear-sky PV, clouds, stochastic load
│   └── kyiv_site_config.json       # Ukraine, 50.45 N — same code, different place
├── dertwin/
│   ├── core/                # Clock, engine, register map loader
│   ├── controllers/         # Site and device orchestration (incl. dynamic add/remove)
│   ├── devices/             # BESS, PV, CHP, energy meter, external models
│   ├── protocol/            # Modbus TCP + RTU servers
│   ├── telemetry/           # Telemetry dataclasses
│   └── main.py
├── examples/
│   ├── simple/              # Single BESS EMS example
│   ├── full/                # Multi-device EMS example with CHP (TCP)
│   ├── mixed/               # Mixed-protocol EMS example (TCP + RTU)
│   ├── seasonal/            # Print a simulated day from a location-aware config
│   └── protocol/            # Shared Modbus TCP and RTU clients
├── state/                   # BESS SOC state files (gitignored)
├── tests/                   # Full test suite
├── generate_compose.py      # Docker Compose generator
├── docker-entrypoint.sh     # Container entrypoint (socat + RTU bridge)
└── Dockerfile

⚙️ Configuration

Sites are defined in JSON. Each asset declares its type, parameters, and protocol bindings:

{
  "site_name": "my-site",
  "step": 0.1,
  "real_time": true,
  "start_time_h": 12.0,
  "register_map_root": "register_maps",
  "external_models": {
    "irradiance": { "peak": 1000.0, "sunrise": 6.0, "sunset": 18.0 },
    "grid_frequency": { "nominal_hz": 50.0, "noise_std": 0.002, "seed": 42 }
  },
  "assets": [
    {
      "type": "bess",
      "capacity_kwh": 100.0,
      "initial_soc": 60.0,
      "protocols": [{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55001, "unit_id": 1, "register_map": "bess_modbus.yaml" }]
    },
    {
      "type": "chp",
      "rated_kw": 4000.0,
      "heat_to_power_ratio": 1.0,
      "min_load_percent": 30.0,
      "max_load_percent": 110.0,
      "protocols": [{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55002, "unit_id": 1, "register_map": "chp_modbus.yaml" }]
    }
  ]
}

real_time: true — engine runs its own loop, use for dertwin CLI and EMS examples real_time: false — caller drives the clock via step_once(), use for tests sim_start_utc — absolute UTC instant the simulation starts from, ISO 8601 (e.g. "2025-10-31T00:00:00Z"). Internal time is always UTC. Required by the clear-sky irradiance model, which has no sun position without a date. Omit it and the clock sits at the Unix epoch, so start_time_h keeps its original meaning. start_time_h — offsets the clock on startup (e.g. 12.0 for noon), relative to sim_start_utc's date. All external models start from this time. data_root — path for CSV inputs (irradiance.series_csv), resolved relative to the config file. Defaults to the working directory. register_map_root — path to register map directory, resolved relative to the working directory where you run dertwin state_root — path for device state files (state_file on a BESS asset), resolved relative to the config file. Defaults to the working directory. data_root — path for CSV inputs (load.profile.csv, irradiance series), resolved relative to the config file. Defaults to the working directory. ip: "0.0.0.0" — required when running inside Docker so port mapping works. Use 127.0.0.1 for local-only.

Unknown asset keys are rejected at build time with a "did you mean" hint, so a typo fails loudly instead of being silently ignored.

Supported asset types

type Class Notable parameters
bess BESSSimulator capacity_kwh, initial_soc, max_charge_kw, max_discharge_kw, ramp_rate_kw_per_s, soc_min_percent, soc_max_percent, limit_mode, round_trip_eff, charge_efficiency, discharge_efficiency, self_discharge_percent_per_day, state_file
inverter PVSimulator rated_kw / ac_rating_kw, dc_capacity_kw, dc_ac_ratio, tilt_deg, azimuth_deg, albedo, derate / losses, module_efficiency, area_m2, temp_coefficient, noct_c
chp CHPSimulator rated_kw, heat_to_power_ratio, min_load_percent, max_load_percent
energy_meter EnergyMeterSimulator (no parameters — observes the site power model)

Location-aware example sites

Two complete sites, config-only — nothing in dertwin/ knows about either place, and a test guards that:

Config Place Plant
configs/stockholm_site_config.json Stockholm, 59.33 N 40 kW DC / 30 kW AC at 45°, 120 kWh BESS
configs/kyiv_site_config.json Kyiv, 50.45 N 36 kW DC / 30 kW AC at 35°, 100 kWh BESS

Print a simulated day from either, with no dependencies beyond the standard library:

python examples/seasonal/plot_day.py stockholm --clear
    UTC   elev     GHI     POA      PV    load     grid    SOC
           deg    W/m2    W/m2      kW      kW       kW      %
  ------------------------------------------------------------
  08:00   10.7   163.4   435.3   16.01   51.57    35.66   55.0
  10:00   16.6   269.1   666.3   23.62   52.57    28.97   55.0
  12:00   14.6   233.6   590.1   21.00   55.84    34.78   54.9
  14:00    5.6    81.8   213.7    7.95   47.51    39.40   54.9

  GHI              ▁▂▄▅▆▇▇████▇▇▆▅▄▂▁                    peak 274.1

Clear-sky resource on the same three dates — this is what the geography buys:

Stockholm Kyiv
Daylight, 31 Oct 8.72 h 9.68 h
Daylight, 21 Jun 18.28 h 16.23 h
Daylight, 21 Dec 5.73 h 7.78 h
GHI peak, 31 Oct 274 W/m² 411 W/m²
GHI peak, 21 Jun 839 W/m² 905 W/m²
GHI peak, 21 Dec 108 W/m² 239 W/m²

See examples/seasonal/README.md for what the two plants then do with that resource, which is a different question.

BESS SOC limits, efficiency and persistence

The SOC window is defended with a hard stop: in the step that would cross a limit, power is clamped so SOC lands exactly on it, and from then on reported active power is exactly 0 while the setpoint keeps pushing that way. The setpoint register keeps whatever the EMS wrote, so dispatch resumes by itself once the pack has headroom — and the energy counters, the site power balance and the meter all follow the actual (clamped) power, not the setpoint.

{
  "type": "bess",
  "capacity_kwh": 100.0,
  "initial_soc": 60.0,
  "soc_min_percent": 10.0,
  "soc_max_percent": 95.0,
  "limit_mode": "hard",
  "max_charge_kw": 50.0,
  "max_discharge_kw": 50.0,
  "round_trip_eff": 0.92,
  "self_discharge_percent_per_day": 0.0,
  "state_file": "state/bess-1.json",
  "state_save_interval_s": 60.0
}

soc_min_percent / soc_max_percent — the hard window. Omit them and it follows soc_limits.lower_2 / soc_limits.upper_2, which is also what the Modbus soc_lower_limit_2 / soc_upper_limit_2 commands write, so an EMS can move the hard limits at runtime. limit_mode — "hard" (default) or "taper" for the pre-0.2 linear derating ramp between the _1 and _2 thresholds. round_trip_eff — split as sqrt() across charge and discharge. charge_efficiency / discharge_efficiency override it per direction. state_file — opt-in SOC persistence. Omit it and every start is a cold start at initial_soc. When set, SOC and the lifetime counters are written atomically on an interval and on shutdown, and restored on the next start; the first boot, a missing file or an unusable one falls back to initial_soc and logs why.

BESS thermal management

Cell temperature derates capability. The curve is a ladder of bands, and the defaults are the ones the model has always had — ≤ 0 °C → 0.5×, ≤ 10 → 0.8×, ≤ 40 → 1.0×, ≤ 50 → 0.8×, ≤ 60 → 0.5×, above → 0.0×. It scales both charge and discharge, and lands in available_charging_power / available_discharging_power.

An unmanaged pack sits at ambient whenever it is idle, so a site that spends the winter between 4 °C and 14 °C spends it at 0.8× nameplate. A managed pack sits in a container whose HVAC holds it inside a setpoint band:

In one line: the HVAC auxiliary draw is accounted only at the PCC — in grid_power_kw, the import/export counters and the energy meter — and not in the site load model or any load-meter telemetry; and a pack that starts outside the band snaps to the nearest edge on its first step, it does not ramp in.

{
  "type": "bess",
  "capacity_kwh": 100.0,
  "thermal": {
    "managed": true,
    "heat_setpoint_c": 15.0,
    "cool_setpoint_c": 30.0,
    "aux_power_kw": 1.5,
    "time_constant_s": 2500.0,
    "derate": {
      "bands": [[0.0, 0.5], [10.0, 0.8], [40.0, 1.0], [50.0, 0.8], [60.0, 0.5]],
      "above_factor": 0.0
    }
  }
}

managed — false by default, and with the whole thermal block absent the battery behaves exactly as it did in 0.2.1.

heat_setpoint_c / cool_setpoint_c — the band, 15 °C and 30 °C by default. Inside it nothing is held: the cell relaxes toward ambient, in either direction, with time constant time_constant_s. It is never allowed to leave the band, so with the default band inside the full-capability zone a managed pack never derates on temperature. The HVAC is ideal within the band — it supplies or removes exactly the heat needed to hold the nearest edge — so a pack that starts outside the band (a restored state file, an ambient_temp_c below the heat setpoint) is brought to that edge immediately rather than over a ramp. heat_setpoint_c above cool_setpoint_c is a config error.

time_constant_s — the relaxation time constant, in seconds. Omit it and it is the pack's own C_th / G, which is 2500 s (≈42 min) with the auto-scaled thermal defaults, whatever the pack size.

aux_power_kw — the container's own draw while heating or cooling is actually active, 0 by default. It is reported as hvac_power_kw on the BESS and enters the site power balance on the load side, exactly as the site load does, so it shows in grid power, the import counter and the meter. It is not netted off the BESS active power: a discharging managed pack still reports what its inverter delivered, and the container's draw is accounted separately. With base_load 7 kW, a 1.5 kW container and an idle pack the meter reads 8.5 kW.

derate.bands — the capability ladder as [upper bound °C, factor] pairs, in increasing order of temperature; the factor of the first band whose bound the cell temperature does not exceed wins. derate.above_factor applies above the last bound. Omit derate and the curve is unchanged, so no existing config shifts.

Cell temperature is always reported in battery_temperature, managed or not, and is still capped at 80 °C.

Solar irradiance

Three models, selected by external_models.irradiance.model:

model Behaviour
sinusoidal The original fixed-shape day: a sine between a configured sunrise and sunset, identical every day of the year everywhere on earth. The default, so existing configs are untouched.
clearsky Real solar geometry for the date and location, times a stochastic cloud index. Selected automatically as soon as you give a latitude.
series GHI replayed from a CSV.
{
  "sim_start_utc": "2025-10-31T00:00:00Z",
  "external_models": {
    "irradiance": {
      "latitude": 59.3293,
      "longitude": 18.0686,
      "timezone": "Europe/Stockholm",
      "altitude_m": 44.0,
      "clearsky_model": "ineichen",
      "linke_turbidity": 3.0,
      "cloud": {
        "enabled": true,
        "model": "ar1",
        "mean_kt": 0.48,
        "phi": 0.65,
        "sigma_day": 0.9,
        "kt_min": 0.08,
        "intraday_sigma": 0.07,
        "intraday_tau_s": 900.0,
        "seed": 59
      }
    }
  },
  "assets": [
    {
      "type": "inverter",
      "ac_rating_kw": 30.0,
      "dc_capacity_kw": 36.0,
      "tilt_deg": 45.0,
      "azimuth_deg": 180.0,
      "derate": 0.86
    }
  ]
}

latitude / longitude — degrees, longitude positive east. Giving a latitude is what switches the model on. timezone — label only, for logs and examples. Internal time is always UTC. clearsky_model — ineichen (default, adds altitude and turbidity), haurwitz (elevation only), or pvlib (needs pip install "dertwin[pvlib]"). linke_turbidity — ~2 very clear, ~3 clear continental, ~5–6 hazy summer. cloud — day-to-day weather regimes as an AR(1) process plus intraday Ornstein-Uhlenbeck variability. phi sets how long overcast spells last, mean_kt the long-run clear-sky fraction. On by default once a location is given; set seed for a reproducible run or enabled: false for a cloudless sky. With a seed, each day's regime is keyed on the UTC calendar date — see below.

Weather, restarts and the calendar

With cloud.seed set, the daily clear-sky index for a simulated UTC date is a function of (seed, date) and of nothing else. That means:

  • restarting the process does not change today's weather, however often it restarts and whatever hour it comes back at;
  • starting the run on a different date does not change any other date — day 2026-06-10 looks the same whether the run began that morning or a hundred days earlier;
  • consecutive dates still have the configured persistence phi and long-run mean mean_kt. The regime is read out of a keyed AR(1) chain rather than drawn independently per date, which is what keeps overcast spells lasting several days instead of collapsing to coin flips.

Before 0.2.1 the chain was seeded once at engine start and stepped from there, so every boot replayed the same first day. A deployment restarted twice a day got the same opening weather every time, and clear days practically never came round.

The intraday variability is deliberately not keyed: it is advanced with the engine's own timestep, which is what keeps its spread independent of the step size, and a restart draws it afresh. So a restart mid-day leaves the day's regime untouched but does change the minute-to-minute wobble on top of it.

With no cloud.seed, behaviour is random per run, exactly as in 0.2.0: a fresh process gets a fresh sky. Within a single process the per-date lookup still holds, so the same day always reports the same regime.

series_csv and series_column: "kt" replay are unaffected — a recorded series is already a function of the date. series_csv — replay recorded data. With series_column: "kt" it drives the cloud index and keeps the clear-sky curve; otherwise it is absolute GHI in W/m². Read once by default; series_refresh_s makes it a live input that is re-read as it changes, with the stochastic cloud model taking over when it goes stale. See A live irradiance series.

What this buys, at Stockholm (59.33 N):

Date Daylight Clear-sky GHI peak
21 Jun 18.3 h ~819 W/m²
31 Oct 8.7 h ~256 W/m²
21 Dec 5.7 h ~93 W/m²

The sinusoidal model gives all three 12.0 h and 1000 W/m².

A live irradiance series

series_csv is read once at build time by default, which is all a replay of recorded data needs. Set series_refresh_s and the same file becomes a live input: dertwin re-reads it as it changes, so a separate fetcher — an Open-Meteo sidecar, a plant's own historian, anything that can write a CSV — can drive the simulated sky from real weather without dertwin knowing anything about where the data came from.

"irradiance": {
  "latitude": 50.0,
  "longitude": 10.0,
  "series_csv": "weather/ghi.csv",
  "series_refresh_s": 300.0,
  "series_stale_after_s": 1800.0,
  "cloud": { "mean_kt": 0.55, "seed": 42 }
}

The keys, all optional:

Key Default Meaning
series_csv — the file to read
series_column ghi_w_m2 the driving column. kt selects the sky-index form
series_time_column timestamp the timestamp column
series_interpolate linear linear between rows, or step to hold each row
series_dni_column dni_w_m2 optional measured beam, used when the header has it
series_dhi_column dhi_w_m2 optional measured diffuse, likewise
series_refresh_s 0 re-read interval. 0 is one-shot — read once, never again
series_stale_after_s 3600 live, never one-shot how long the last row is held before the series counts as stale
series_max_gap_s 0 a gap wider than this is missing data rather than something to interpolate across. 0 bridges any gap
series_handover_tau_s cloud.intraday_tau_s how long a switch between the series and the model takes to complete. 0 makes each switch a plain jump

The file contract

So an external fetcher knows exactly what to write:

  • A header row is required. Column order does not matter and extra columns are ignored, so a file carrying temperature, wind and pressure alongside irradiance is fine — dertwin reads the columns it was told about.

  • Timestamps are UTC. ISO 8601, with a trailing Z, an explicit offset, or no zone at all, in which case UTC is assumed. Rows may be in any order; they are sorted on read.

  • Units. ghi_w_m2, dni_w_m2 and dhi_w_m2 are W/m². kt is the dimensionless clear-sky index in [0, 1] — the fraction of clear-sky irradiance reaching the ground.

  • GHI or kt, not both. With series_column: "kt" the series replaces the stochastic cloud model and the clear-sky curve stays; otherwise the column is absolute GHI and replaces the curve entirely.

  • DNI and DHI are optional and are believed when present. Give both and they are used as they stand, and are not adjusted to close with GHI — measured triples rarely close, and silently fixing one of three measured numbers would hide a data problem. Give one and the other is derived from GHI. Give neither and the Erbs correlation splits GHI, as it always has.

  • Duplicate timestamps: the last row in the file wins. A correction appended later therefore overrides the row it corrects.

  • A blank cell is a row that column does not have. Each column is built from the rows where its own cell held a number, so a half-filled DNI column still leaves a complete GHI series.

  • Write the file atomically. Write a temporary file in the same directory and rename it over the target. That is the one pattern under which a reader can never see a half-written file:

    tmp = path.with_suffix(".csv.tmp")
    tmp.write_text(body)
    os.replace(tmp, path)          # atomic within a filesystem
    

    dertwin stats the file before and after each read and throws away a snapshot that moved underneath it, so an in-place append is survivable — but it costs a refresh interval each time it is caught, and the rename costs nothing.

  • Growing the file is the normal case. Rewrite it whole with the new rows appended, or keep a rolling window; either works, and only the rows covering the simulated instant matter.

  • Backfill is allowed and is never replayed. A fetcher that comes back up may write the outage it missed along with fresh data; rows older than the simulated instant are not re-run, because the clock does not rewind. Only the pair of rows bracketing the current instant can reach the output, so backfilled history serves as the lower bracket and nothing more. Rows in the future are fine too, and are used as the upper bracket — a forecast ahead of "now" costs nothing.

  • A malformed row is skipped, not fatal. In live mode an unparseable timestamp or value is counted, logged and dropped, so one torn line cannot take the simulation with it. A file missing its header or its driving column is a different matter: it is unusable, and the previous snapshot is kept.

Only the file is re-read. Nothing else in the config is, so a fetcher cannot change the site's latitude, its panels or its battery.

When the series goes stale

A live feed will eventually be late — the fetcher dies, the network goes, the container is rescheduled. series_stale_after_s is how long the last row keeps being served once simulated time has passed it; a fetcher writing hourly rows is always a little behind, and without the hold every instant between updates would have no data at all.

Past that, the series is stale and the stochastic cloud model takes over. Not a dark sky and not a cloudless one: both are wrong, and both are wrong in a way that quietly corrupts whatever is reading the twin. A dark sky tells an EMS the plant has failed; a cloudless one tells it the plant is at nameplate. The stochastic model tells it the weather is ordinary, which is the only honest answer when the measurement is gone. The same applies to a file that is missing or unreadable at startup: the run begins on the stochastic model and picks the feed up when it appears, rather than refusing to start.

Each transition is one log line, in both directions:

WARNING  weather/ghi.csv: series is stale at 2025-06-22T06:00:00+00:00
         (past the last row); falling back to the stochastic cloud model
INFO     weather/ghi.csv: fresh series data at 2025-06-22T09:12:00+00:00;
         leaving the stochastic cloud model

A run that never loses its feed says nothing at all, and one that flaps says exactly when and how often.

The switch carries no step of its own. What crosses a handover is how cloudy it is — the clear-sky index — not the W/m² a particular sun elevation happened to deliver, and it is carried by the same rule in both directions: the last index reported is held and relaxed away at the cloud model's own intraday correlation time.

Going into the fallback, that needs no new machinery. The AR(1) model's index is kt_day + x, a daily regime plus a mean-reverting perturbation, and the perturbation already decays at intraday_tau_s. Seeding x with the difference between the last measurement and today's regime makes the first index the model reports exactly the last one measured, after which it relaxes back to the regime at the rate it always does. The day's regime is left alone deliberately: a measurement that ends on a bright minute must not turn the whole day clear.

Coming back, the series is data and cannot be seeded, so an explicit offset with the same time constant decays onto it instead. The alternative — jumping straight to fresh data — is available as series_handover_tau_s: 0, and is the right choice if you would rather the twin always report the measurement than always move smoothly.

Either way the switch tick itself is a step of zero, and every step after it is one the stochastic model could have produced on its own. A short blend over an arbitrary window would have done the same job for the eye, but it would have reported a sky neither source produced and added a timescale the simulation does not otherwise have.

The index is what carries over, so the beam/diffuse split has to be taken from the GHI actually being reported rather than from the file's. The Erbs correlation is strongly non-linear in the clear-sky index — a kt of 0.5 is about 93% diffuse where a kt of 0.85 is about 58% — so splitting the file's GHI and scaling the components afterwards would leave GHI continuous while handing a tilted array the diffuse fraction of a much cloudier sky, and that shows up as a step in plane-of-array irradiance and so in PV power. A file that carries measured dni_w_m2 / dhi_w_m2 is a different matter: those are believed, so they are scaled with GHI, which keeps the measured beam fraction and whatever closure the file had.

Everything here — the refresh interval, the grace period, the handover — is measured in simulated time, for the same reason the cloud regime is: a run that is not in real time, or one replayed from the same config, has to behave the same way twice. In a real-time deployment, which is what a live feed is for, the two coincide.

Ambient temperature is not part of this. The series drives irradiance only; ambient_temperature stays on its own model.

PV array orientation

tilt_deg and azimuth_deg (clockwise from true north; 180 is due south) enable plane-of-array transposition. Without a tilt, irradiance is taken as already in-plane — the pre-0.2 behaviour. dc_capacity_kw (or dc_ac_ratio) oversizes the array relative to ac_rating_kw so the inverter actually clips, as real plants do; leave both out and DC/AC stays 1.0 and nothing ever clips. See dertwin/devices/pv/README.md.

Site load

The site load is multiplicative, so each piece can be configured without fighting the others:

load_kw = base_kw × profile(hour) × weekday × drift × (1 + noise)
{
  "external_models": {
    "load": {
      "base_kw": 50.0,
      "profile": {
        "model": "hourly",
        "hourly": [0.55, 0.52, 0.50, 0.50, 0.52, 0.60, 0.75, 0.95,
                   1.05, 1.05, 1.00, 0.98, 0.95, 0.95, 0.98, 1.05,
                   1.20, 1.35, 1.30, 1.15, 1.00, 0.85, 0.70, 0.60],
        "interpolate": true,
        "normalize": true
      },
      "weekday_factor": 1.0,
      "weekend_factor": 0.75,
      "start_weekday": "monday",
      "drift": { "sigma": 0.12, "tau_s": 10800.0, "min_factor": 0.7, "max_factor": 1.3 },
      "noise": { "sigma": 0.02, "tau_s": 30.0 },
      "min_kw": 0.0,
      "max_kw": null,
      "seed": 7
    }
  }
}

base_kw — the average load. The profile is normalised to a daily mean of 1.0, so changing the shape never moves the average. profile.model — flat (default, the pre-0.2 constant), hourly (24 factors), parametric (a night baseline with morning and evening bumps), or csv (an hour-of-day table at any resolution; a kw column sets base_kw from its mean). Hourly factors sit at their hour centres and interpolate circularly, so there is no discontinuity at midnight. weekend_factor — applied on Saturday and Sunday. The clock is an offset from the start of the run rather than a date, so start_weekday places the week and it advances at each simulated midnight. drift — slow mean-reverting random walk, the "this week is busier than usual" term. sigma is the standard deviation of the multiplicative factor and tau_s its correlation time; bounded by min_factor / max_factor. Keyed on simulated time, so a restart does not replay it — see below. noise — the same process on a timescale of seconds. seed — one seed drives both random terms, through a stream each, so adding or removing one does not shift the other's numbers. Drift and noise are off unless configured.

The drift has the same restart property as the cloud regime: with a seed, the drift factor at an instant is a function of (seed, that instant), so a process that boots at 13:00 reports the drift the process it replaced would have been reporting. It keeps the exact discrete-time Ornstein-Uhlenbeck statistics — sigma is the standard deviation of the factor and tau_s its correlation time, both independent of the simulator's step — by sampling on a fixed internal lattice of a sixteenth of tau_s rather than on the tick.

This needs a top-level sim_start_utc, because that is what gives the clock an absolute instant to key on. Without one the clock restarts at zero on every boot, so the drift restarts with it; the model keys on the run clock, which is the most that clock can offer.

The fast noise term stays free-running on purpose: zero-mean with a correlation time of half a minute, there is nothing in it worth reproducing across a restart.

The legacy external_models.power.base_load_w still works and is still a flat load; a load block supersedes it, and a load block with no base_kw inherits its value.

Migrating from 0.1.x

Every existing config key still works and no config in configs/ needed editing. Irradiance in particular is unchanged until you ask for more: the sinusoidal model stays the default, and the date- and location-aware one switches on only once you give a latitude.

Two BESS behaviours did change:

  • SOC limits no longer taper. soc_limits.lower_2 / upper_2 are now hard stops that SOC lands on exactly; lower_1 / upper_1 are accepted and ignored. Set "limit_mode": "taper" per asset to keep the old ramp.
  • round_trip_eff now has an effect. The pre-0.2 model multiplied by the efficiency on both the charge and discharge leg, so the realised round-trip efficiency was always 1.0 no matter what was configured. Charging now stores less than arrives at AC and discharging drains more than reaches AC, so a cycle costs what the config says it costs.

Also fixed: service_current now reports amps (it reported kW into an amps register), and reactive/apparent power are derived from the clamped power instead of the pre-clamp setpoint.

Protocol Configuration

Each asset's protocols array supports both Modbus TCP and Modbus RTU. A single device can expose multiple protocols simultaneously.

Modbus TCP:

{ "kind": "modbus_tcp", "ip": "0.0.0.0", "port": 55001, "unit_id": 1, "register_map": "bess_modbus.yaml" }

Modbus RTU:

{ "kind": "modbus_rtu", "port": "/tmp/dertwin_device", "baudrate": 9600, "parity": "N", "stopbits": 1, "unit_id": 1, "register_map": "bess_modbus.yaml" }

RTU parameters baudrate, parity, stopbits, bytesize, and timeout all have sensible defaults (9600/N/1/8/1.0) and can be omitted.

Register map fields:

Field Required Description
name yes Human-readable label, used in logs and the EMS client
internal_name yes Maps to the device's internal telemetry or command field — must match the attribute name in the corresponding telemetry class (see dertwin/telemetry/README.md)
address yes Modbus register address (0–65535)
type yes uint16, int16, uint32, int32
scale yes Multiplier applied on read, divisor applied on write
count yes Number of registers (1 for 16-bit, 2 for 32-bit)
func yes Function code: 0x02 discrete input read, 0x03 holding read, 0x04 input read, 0x06 single write, 0x10 multi-register write
direction yes read or write
endian no big (default) or little — for devices like Sungrow BESS and Carlo Gavazzi meters that use little-endian 32-bit register layout
unit no Physical unit label (V, kW, Hz, etc.)
description no Free-text note
options no Enum mapping for status/mode registers

name and internal_name can differ — name is what the EMS client sees, internal_name is what the device simulator uses internally. For example, on_grid_power_setpoint (name) maps to active_power_setpoint (internal_name) on the BESS device.

For detailed architecture and per-package docs, see dertwin/README.md.


🔀 Mixed Protocol Example (TCP + RTU)

This example runs a site with BESS on Modbus TCP and PV + energy meter on Modbus RTU. The EMS controls the BESS over TCP and monitors the RTU devices for observability.

Prerequisites

Install socat to create virtual serial port pairs:

# macOS
brew install socat

# Ubuntu / Debian
sudo apt install socat

Running the example

Terminal 1 — create virtual serial pairs and start the simulator:

# Create virtual serial port pairs (simulator <-> EMS client)
socat -d -d pty,raw,echo=0,link=/tmp/dertwin_pv pty,raw,echo=0,link=/tmp/dertwin_pv_client &
socat -d -d pty,raw,echo=0,link=/tmp/dertwin_meter pty,raw,echo=0,link=/tmp/dertwin_meter_client &

# Start the simulator (from repo root)
dertwin -c configs/mixed_protocol_config.json

You should see:

INFO | Building site: mixed-protocol-site
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_pv | baudrate=9600 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_meter | baudrate=9600 | unit=1
INFO | Simulation engine started | step=0.100s

Terminal 2 — run the mixed-protocol EMS:

cd examples
python main_mixed.py

Expected output:

[BESS-1] TCP connected
[PV] RTU connected
[METER] RTU connected
[BESS-1] Starting in CHARGE mode

[EMS] Mixed-protocol EMS running
  [BESS-1] RUN  | SOC= 50.0% | P= -30.00 kW | MODE=charge
  [PV]    P= 16.40 kW (producing)
  [METER] Grid= +23.57 kW (importing) | Freq=50.000 Hz | Import=0.1 kWh | Export=0.0 kWh

The key point: socat creates a pair of linked pseudo-terminals for each connection. The simulator opens one end (/tmp/dertwin_pv) and the EMS client opens the other (/tmp/dertwin_pv_client). Both sides must use different ends of the pair.

If RTU serial ports are unavailable, the EMS will still run with BESS-only control — PV and meter telemetry will show as unavailable.


🐳 Docker

TCP-only configs

For configs that only use Modbus TCP, Docker setup is straightforward:

python generate_compose.py configs/full_site_config.json
docker compose up --build

TCP ports are mapped automatically from the config. Connect your EMS to localhost:<port>.

Docker with RTU

RTU serial devices use pseudo-terminals (/dev/pts/) which exist only inside the container's kernel namespace and can't be accessed from the host via volume mounts. The entrypoint solves this by bridging each RTU serial port to a TCP port inside the container using a Python asyncio relay. From the host, socat converts the TCP connection back into a local PTY that the EMS opens as a normal serial port.

Step 1 — generate the compose file and start the container:

python generate_compose.py configs/mixed_protocol_config.json
docker compose up --build

You should see:

[entrypoint] Creating serial pair: /tmp/dertwin_pv <-> /tmp/dertwin_pv_bridge
[entrypoint] Bridging /tmp/dertwin_pv_bridge -> TCP port 56001
[bridge] /tmp/dertwin_pv_bridge <-> TCP :56001
[entrypoint] Creating serial pair: /tmp/dertwin_meter <-> /tmp/dertwin_meter_bridge
[entrypoint] Bridging /tmp/dertwin_meter_bridge -> TCP port 56002
[bridge] /tmp/dertwin_meter_bridge <-> TCP :56002
[entrypoint] RTU bridges ready
[entrypoint] Starting DERTwin simulator
INFO | Starting Modbus TCP server | 0.0.0.0:55001 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_pv | baudrate=9600 | unit=1
INFO | Starting Modbus RTU server | port=/tmp/dertwin_meter | baudrate=9600 | unit=1

generate_compose.py detects RTU ports in the config and automatically exposes the bridge TCP ports (56001, 56002, ...) alongside the regular Modbus TCP ports in the generated docker-compose.yml.

Step 2 — in a separate terminal on the host, create local PTY endpoints (requires socat):

socat pty,raw,echo=0,link=/tmp/dertwin_pv_client tcp:localhost:56001 &
socat pty,raw,echo=0,link=/tmp/dertwin_meter_client tcp:localhost:56002 &

This creates /tmp/dertwin_pv_client and /tmp/dertwin_meter_client on the host — the same paths the EMS expects.

Step 3 — run the EMS (same command as the local setup):

cd examples
python main_mixed.py

The EMS uses the exact same config for both local and Docker setups — the serial paths (/tmp/dertwin_pv_client, /tmp/dertwin_meter_client) are identical. The only difference is how those paths are created: locally via direct socat pairs, or via Docker with TCP bridging.

Override config at runtime

docker run \
  -v /path/to/my/configs:/app/configs:ro \
  -e CONFIG_PATH=/app/configs/my_site.json \
  -p 55001:55001 \
  dertwin-simulator

🧪 Tests

pytest

The test suite covers device physics (BESS, PV, CHP, energy meter), battery thermal management (including a golden day-long comparison that an unmanaged pack still reproduces the 0.2.1 model exactly), solar geometry and clear-sky irradiance against published reference values, cloud-model statistics, per-date determinism of the cloud regime and the load drift across restarts, the statistics of the stochastic site load, register encoding with per-register endianness, FC02 discrete input routing, external models, protocol parity (TCP and RTU), mixed-protocol engine integration, runtime asset add/remove, and full end-to-end site integration via Modbus. See tests/ for structure.

The built-in solar model is also cross-checked against pvlib, which is optional, so that suite skips unless you install it:

pip install "dertwin[pvlib]"

📈 Roadmap

  • Scenario engine — scripted event sequences
  • Markov-regime cloud model as an alternative to AR(1)
  • Location- and date-aware clear-sky irradiance with cloud cover
  • Plane-of-array irradiance, DC/AC ratio and inverter clipping
  • Stochastic site load with daily profile and drift
  • Hard BESS SOC limits with optional persistence
  • BESS thermal management with a configurable temperature derate curve
  • Dynamic asset add/remove at runtime
  • CHP support with realistic state machine
  • Modbus FC02 discrete input support
  • Per-register endianness (big/little)
  • Modbus RTU support
  • Mixed-protocol sites (TCP + RTU)
  • Docker RTU-over-TCP bridging
  • Published PyPI package

🧠 Use Cases

  • EMS algorithm development and validation
  • SCADA/HMI integration testing
  • Protocol compliance testing (TCP and RTU)
  • DER fleet orchestration prototyping
  • Frequency and voltage response simulation
  • Mixed-protocol site simulation
  • CHP dispatch and startup-sequence testing against EMS
  • Live scenario scripting — bring assets online and offline during a simulation
  • EMS-in-the-loop tests where the asset roster is decided by the controller under test

🤝 Contributing

Contributions are welcome. Before diving in, read dertwin/README.md — it covers the simulator architecture, how devices are modeled, the engine and clock design, and how to add new device types or protocols.

See CONTRIBUTING.md for full guidelines, including how to add new protocols and test RTU without hardware.


📜 License

MIT License


👤 Author

Oleksandr Spivak

Metadata

Release files for dertwin 0.2.3

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for dertwin 0.2.3
File Size Uploaded Provenance Actions
dertwin-0.2.3.tar.gz 138.7 kB Without provenance Details for dertwin-0.2.3.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for dertwin 0.2.3
File Interpreter ABI Platform Actions
dertwin-0.2.3-py3-none-any.whl Python 3 none any Details for dertwin-0.2.3-py3-none-any.whl

Total release size: 259.0 kB

Release files / dertwin-0.2.3.tar.gz

Download URL dertwin-0.2.3.tar.gz
Size 138.7 kB
Tags Source
SHA-256 checksum
How to use checksums
c0276cecde901c805228d55796d7279015398f0a765f50b87f39cd41075a47fb
BLAKE2b-256 checksum
How to use checksums
8a830c075c212c9fc45930d8678d833c3f87f1d0e52095229a97c6a074bd8224
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.12

Release files / dertwin-0.2.3-py3-none-any.whl

Download URL dertwin-0.2.3-py3-none-any.whl
Size 120.3 kB
Tags Python 3
SHA-256 checksum
How to use checksums
c400a5060ee2f2688f6f166f4e7ece0fa1b975b2a78310f2017849fa0b28738e
BLAKE2b-256 checksum
How to use checksums
2ec8db6edcc8a68fae8235496f594eb259ae823d7cf9116cb44b03322c4c193d
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.12

Security for dertwin 0.2.3

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page