With the DistrictGenerator, we present an python-based open-source tool aimed at urban planners, energy suppliers, housing associations, engineering firms, architectural professionals, as well as academic and research institutions. Starting from a small set of building and scenario information, DistrictGenerator creates archetype-based building models, generates time-resolved demand and generation profiles, sizes decentralized and central energy-system technologies, optimizes their operation, and evaluates district scenarios using technical, economic, and environmental key performance indicators. Consequently, users can discern actionable measures to harmonize energy supply.

The DistrictGenerator is being developed at RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate.

General Motivation

In the early stages of neighborhood planning, crucial data such as demand profiles of electricity, heating, domestic hot water, and occupancy profiles are often not available. The absence of this data hampers accurate evaluations of energy systems in districts. The DistrictGenerator seeks to advance the applicability of sustainable, cross-sectoral energy systems in neighborhoods, with a specific emphasis on exploiting synergy potentials among buildings of diverse usage structures through integrated concepts. We summarize the key contributions of the DistrictGenerator as follows:

  • An open-source tool with minimal input requirements. Leveraging pre-set elements and default values of temporally resolved demand profiles, as well as decentralized heat generator sizing conforming to DIN standards.

  • The tool enables the bottom-up representation of entire urban structures through neighborhood models, affording a sufficiently detailed analysis foundation.

  • Facilitation of central operational optimization and presentation of analytical results and key performance indicators. This supports the examination of various neighborhood types and supply scenarios concerning technology selection and penetrations. We thereby create a platform for early-stage comparison of neighborhood concepts with the flexibility of selecting different variants, given the tool's rapid recalculations.

Overview

DistrictGenerator combines building archetypes, stochastic user behavior, reduced-order thermal building models, renewable generation models, energy-system sizing, time-series aggregation, mathematical optimization, and post-processing in one reproducible Python workflow.

Typical applications include:

  • Generation of a bottom-up representation of neighborhoods with synthetic building data,
  • Generation of synthetic building specific energy-demand and generation time series for entire neighborhoods with different building types and usage structures,
  • Analysis of heat pumps, photovoltaic systems, storage systems, electric vehicles, and district heating,
  • Investigation of decentralized and centralized energy-supply concepts,
  • Sizing of energy technologies and evaluation of energy-system operation and its technologies.

DistrictGenerator covers four main parts of a district energy-system study:

  1. DistrictGenerator creates building-level representations from basic information such as building type, construction year, retrofit state, construction type, floor area, and selected energy technologies. Residential building archetypes are enriched using TEASER and building-stock information based on TABULA. Non-residential buildings are represented using dedicated archetype data and use-specific assumptions, including data derived from SIA 2024.
  2. DistrictGenerator generates building-specific profiles for space heating, space cooling, domestic hot water, household electricity, occupancy, internal heat gains, photovoltaic generation, solar-thermal generation, and electric-vehicle availability and charging.
  3. DistrictGenerator models and evaluates decentralized building energy systems as well as central district energy systems. Technologies include heat pumps, electric heaters, boilers, biomass boilers, oil boilers, hydrogen boilers, combined heat and power units, fuel cells, district heating, photovoltaic systems, solar-thermal collectors, batteries, thermal energy storage, electric vehicles, compression chillers, and wind turbines. Representative time periods are generated using k-medoids clustering to reduce the computational effort of annual optimization. Optimization is formulated with Pyomo. The example configuration uses the open-source solver HiGHS, which is installed with the requirements. Other solvers (gurobi, cbc, glpk, scip) can be selected with SOLVER_NAME in the .env configuration file; commercial solvers such as Gurobi require a license.
  4. Simulation and optimization results are evaluated using technical, economic, and environmental key performance indicators. They include annual energy demands, grid imports and exports, renewable generation, peak loads, self-consumption and coverage indicators, energy-carrier consumption, investment and annualized costs, operation costs, CO₂ emissions, and technology-specific energy balances. Results are additionally summarized in a configurable PDF district energy certificate.

Getting started

Install the DistrictGenerator

To install, first clone this repository with

git clone https://github.com/RWTH-EBC/districtgenerator

and secondly run:

pip install -e districtgenerator

Editable installation is recommended for researchers who want to inspect, extend, or modify the source code.

Once you have installed the DistrictGenerator, you can check the examples to learn how to use the different components.

Minimum manual required input data

To generate your district, you need to know some information about its buildings. The minimal input data set was defined following the TABULA archetype approach:

  • id: building ID (just numerate the buildings)
  • building: building type (SFH = single family house, TH = terraced house, MFH = multi family house, AB = apartment block, OB = office building, SC = school, GS = grocery store, RE = restaurant, MFH+GR = multi family house + grocery store, AB+GR = apartment block + grocery store, MFH+RE = multi family house + restaurant, AB+RE = apartment block + restaurant)
  • year: construction year (the calendar year in which the building was constructed)
  • construction_type: building thermal mass (0 = lightweight construction, 1 = medium construction, 2 = heavyweight construction)
  • retrofit: retrofit state according to TABULA (0: existing state, 1: usual refurbishment, 2: advanced refurbishment)
  • area: reference floor area (given in square meters)
  • night_setback: night temperature setback (0 = no night setback, 1 = with night setback)
  • heater: selected heat generator type (HP = heat pump, CHP = combined heat and power, FC = fuel cell, BOI = boiler, heat_grid = district heating). Use opt or a candidate list such as opt:[HP,BOI] to select the cheapest feasible heating concept with existing sizing rules.
  • dhw_heater: selected domestic hot water generator type (0: no decentral domestic hot water generator, EH_DHW = electric heater)
  • cooling: calculation of cooling demand (0 = no cooling, 1 = with cooling)
  • cooler: cooling supply (CC = local compression chiller, cooling_grid = network cooling). If omitted, heater=heat_grid uses network cooling; other heaters use local CC. Only applies when cooling=1.
  • EV: electric vehicle share - fraction between 0 and 1 representing the proportion of electric vehicles in the building's total vehicle inventory
  • fTES: thermal energy storage size in liters per kW heating capacity of the heat generation system
  • fBAT: battery storage size in Wh per W of PV system power (Wh/W_PV)
  • fPV1: fraction of total roof area covered with photovoltaics (the side with azimuth angle gammaPV, based on TABULA building typology roof area data)
  • fPV2: other side of the roof
  • fSTC: fraction of roof area equipped with solar thermal collectors (based on TABULA building typology roof area data)
  • gammaPV: azimuth angle of roof side 1 in degrees (0° = south-facing orientation)
  • EV_charging: electric vehicle charging behavior (bidirectional = charging and discharging with use as electricity storage, on-demand = charging as needed, intelligent = optimized charging)

The example_decentral.csv file can be used as template.

Additional configuration categories and input data

All default values are defined in settings.py, which is the single source of truth. General modeling assumptions are managed through Pydantic-based configuration classes. Without env_path, the Datahandler uses these defaults.

To override values, create your own file in data/config (e.g. .env.CONFIG.MYPROJECT) that contains only the parameters you want to change, and load it with Datahandler(env_path=".env.CONFIG.MYPROJECT"). Files in other locations can be loaded with an absolute path.

.env.CONFIG.EXAMPLE lists all parameters with description, unit and default value. Copy the lines you need and remove the leading # . The EXAMPLE is generated from settings.py and must not be edited by hand. After changing settings.py, regenerate it with python -m districtgenerator.config.generate_env_example. Local .env.CONFIG* files in data/config are ignored by git (except EXAMPLE and FREIBURG).

The configuration includes assumptions and parameters related to location and weather, temporal resolution, heating and cooling periods, building design conditions, thermal building model, economic parameters, energy prices, emission factors, heating networks, central and decentralized technologies, optimization, solver settings, and report generation.

All input data such as weather, postal codes, scenarios, pipes and SIA 2024 is read from districtgenerator/data, sorted into subfolders by topic:

  • config: configuration files (generated template .env.CONFIG.EXAMPLE, shared configs and your own .env.CONFIG.* files)
  • scenarios: scenario files (.csv) with the buildings of a district
  • site: postal codes, coordinates, weather stations and cooling load zones
  • weather: test reference years (TRY) of the DWD
  • buildings: SIA 2024, non-residential archetypes, lighting and car data
  • energy_systems: pipe specifications, wind turbine power curves and heat pump COP time series
  • report: translations for the PDF certificate
  • raw: source data and scripts used to create the files above; the districtgenerator does not read this folder

Own scenario files can be placed in another folder with Datahandler(scenario_file_path=...). The former parameters filePath and srcPath are deprecated and ignored. Fixed data such as the file format of the TRY weather data, the cooling load zones and the soil properties are constants in config/settings.py and cannot be changed via a config file.

In your own config file, set RANDOM_SEED=42 for repeatable stochastic building and demand profiles; leave it empty for unrestricted randomness. Set DESIGN_ENERGY_HUB=True to request an energy hub without a thermal network. Enable technologies separately, e.g. C_PV__FEASIBLE=True. Heating networks trigger hub design automatically.

Workflow of the DistrictGenerator

The district generator integrates multiple open-source tools and databases. The figure below visualizes the dependencies of external tools and data with internal functions. The user input for the parameterization of a neighborhood consists of a minimum of data. First, the user enters the number of buildings and basic information about each building, namely the building type, year of construction, retrofit level, and net floor area. The number of buildings to be calculated is not limited by the program. Optionally, the site of the district, the time resolution of the profiles and the test reference year (TRY) for weather data can be modified. The Datahandler runs the following steps; generateDistrictComplete runs steps 1 to 7 in one call. Each step names the package that implements it.

flowchart TD
    input[/"Scenario file (.csv) and .env.CONFIG file"/] --> env
    env["1 generateEnvironment<br/>environment: TRY weather, site, solar irradiance, soil"] --> init
    init["2 initializeBuildings<br/>buildings: building features of the scenario file"] --> geo
    geo["3 generateBuildings<br/>buildings.thermal: envelope from TEASER/TABULA or non-residential archetypes"] --> dem
    dem["4 generateDemands<br/>buildings.profiles: occupancy, electricity, DHW, internal gains, EV<br/>buildings.thermal: heating and cooling with 5R1C, 7R2C or four elements"] --> dec
    dec["5 designDecentralDevices<br/>energy_systems, optimization.heating_concept"] --> central
    central{"Heat grid or energy hub?"} -- yes --> hub["6 design heat grid and central devices<br/>energy_systems.heating_network, optimization.energy_hub_sizing"]
    central -- no --> clu
    hub --> clu["7 typical periods<br/>time_series: k-medoids clustering"]
    clu --> opt["8 optimizationClusters<br/>optimization.operation with Pyomo"]
    opt --> kpi["9 calculateKPIs<br/>analysis: KPIs, plots, PDF certificate"]

To obtain a fully parameterized building model, the TEASER tool performs a data enrichment with data from the TABULA WebTool that provides statistical and normative information about the building stock. Finally, the TEASER python package determines the geometry and material properties of the buildings. As the TABULA WebTool defines archetypal building properties for type, age class and retrofit level, the generated districts are composed of representative buildings, making them ideal for representative analyses or scalability studies. The number of occupants within a dwelling is randomly determined, but within defined limits (1 to 4 occupants for each flat in multi-family houses and apartment block, 2-5 occupants in single-family houses and terraced houses), and serves as input data for the richardsonpy tool to calculate stochastically the time-resolved occupancy profiles. Furthermore, the Stromspiegel provides statistical data on annual electricity consumption in German dwellings. Annual consumption is assigned to each dwelling with a possible standard deviation of 10%, upon which the time-resolved electricity profile is created using the stochastic profile generator richardsonpy again. The electricity and occupancy profiles serve as input for a time-resolved internal gain calculation. Additionally, the occupancy profiles are needed for domestic hot water profile generation, for which functions from the openDHW tool are utilized. Finally, the static building data, as well as the time-resolved weather and internal gain data, are included in the space heating profile generation. These are computed by means of a 5R1C- or 7R2C-substitution model according to VDI 6007-1 using the simplified hourly method. Non-residential buildings use archetype data and usage profiles of SIA 2024 instead of TABULA and richardsonpy.

Based on the demand profiles, the decentral devices of each building are sized, e.g. heat pumps, boilers, PV, solar thermal collectors, batteries and thermal energy storages. If buildings are connected to a heat grid or an energy hub is requested, the heat grid and the central devices are designed as well. The annual time series are then reduced to typical periods with k-medoids clustering, the operation of all devices is optimized for each typical period, and the results are evaluated with technical, economic and environmental key performance indicators.

Package structure

The packages of the districtgenerator follow its workflow. The Datahandler runs the steps in this order and delegates each step to its package:

districtgenerator/
├── datahandler.py     # runs the workflow step by step
├── config/            # configuration loaded from .env.CONFIG files
├── environment/       # weather, site conditions, solar irradiance, soil temperature
├── buildings/
│   ├── typology/      # residential, non-residential and mixed-use buildings, SIA 2024
│   ├── thermal/       # thermal building models: 5R1C, 7R2C and four elements
│   └── profiles/      # occupancy, electricity, DHW, internal gains, cars
├── energy_systems/    # technologies, building and central energy systems, heat grid, wind turbines
├── time_series/       # typical periods and time resolution
├── economics/         # annuities and price paths
├── optimization/      # decentral heating concept, central dimensioning and operation
├── analysis/          # KPIs, plots and the certificate
├── file_io/           # saving and loading of profiles and districts
├── utilities/         # paths (DATA_DIR, RESULTS_DIR) and helpers without domain knowledge
└── data/              # input data, one subfolder per topic; raw/ holds source data that the code does not read

Import the Datahandler with from districtgenerator import Datahandler.

Final output of the DistrictGenerator

DistrictGenerator stores generated profiles and optimization results in the configured results directory (districtgenerator/results by default, or the folder given with Datahandler(resultPath=...)). The directory separates building demand profiles, renewable generation profiles, and optimization results so that intermediate results can be reused independently for post-processing or subsequent simulations. The exact number of building-specific files depends on the investigated district and the selected configuration.

The time-series file contains the main time-dependent profiles:

  • heating: space heating demand
  • cooling: space cooling demand
  • dhw: domestic hot water demand
  • elec: electricity demand for lighting and electric household devices
  • gains: internal gains from persons, lighting and electric household devices
  • occ: occupancy profile
  • EV_carcharging_ondemand: electric vehicle charging profile for on-demand charging behavior

The static file contains values that describe the building or its users but do not vary over time:

  • nb_units: number of residential units or non-residential building units
  • nb_occ: number of occupants per unit
  • heatload: design heating load
  • bivalent: heating load at the bivalent temoperature
  • ev_capacity: selected ev battery capacities

The generation directory contains renewable generation profiles calculated during device sizing. For decentralized systems, DistrictGenerator creates separate files for every building:The PV and solar-thermal profiles are calculated using the building's roof area, roof orientation, input technology parameters, and available solar radiation.

The optimization directory contains the detailed solutions of the energy-system optimization. DistrictGenerator reduces the full annual time series to representative periods using k-medoids clustering. A separate optimization problem is solved for every representative cluster. Consequently, the result directory contains one solution file per cluster. They contain the raw decision-variable values of the optimization model depending on the technologies present in the scenario.

Finally, the DistrictGenerator generates a PDF report summarizing the results of the energy-system optimization by various key performance indicators.

Testing

The tests folder contains the following tests. Run them from the repository root, e.g. with python -m pytest tests:

  • test_examples.py: functional test of the examples 1 to 5, which checks the whole chain from data input and initialization to the calculated profiles
  • test_results.py: regression test of the examples 5, 7, 8 and 9 with a fixed random seed. Demand profiles, residual loads and KPIs are compared with the reference results in tests/results_data/reference. After an intended change of the results, run it with the environment variable UPDATE_REFERENCE_RESULTS=1 to replace the reference files and check the changes with git diff before committing them. The optimization results depend on the solver and its version.
  • test_structure.py: imports of all modules, the thermal model registry and shared helpers
  • test_heating_concept.py: selection of the cheapest heating concept, solved with HiGHS
  • test_operation_devices.py: completeness of the device integration in the operation optimization model (the model is built but not solved)
  • test_time_series.py: k-medoids clustering and the mapping of the clustered profiles
  • unit_test.py: single functions such as the change of the time resolution, economic year groups and the sizing of building devices, with expected values calculated by hand
  • test_env_config.py: checks that the EXAMPLE is up to date and that config files only use known keys

How to contribute

The documentation and examples should be understandable and the code bug-free. As all users have different backgrounds, you may not understand everything or encounter bugs. If you have questions, want to contribute new features or fix bugs yourself, please raise an issue here.

If you wrote a new feature, create a pull request and assign a reviewer before merging. Once review is finished, you can merge.

Authors

Alumni

  • Sarah Henn
  • Tobias Beckhölter

Reference

We presented or applied the library in the following publications:

  • S. Henn, J. Schölzel, T. Beckhölter, C.Wüller, R. Hamze, D. Müller. Districtgenerator: Generating building-specific load profiles for residential districts. Journal of Open Source Software. https://joss.theoj.org/papers/10.21105/joss.07657

  • J. Schölzel, S. Henn, R. Streblow, D. Müller. Evaluation of Energy Sharing on a Local Energy Market Through Comparison of Energy Management Techniques. 36th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems. https://doi.org/10.52202/069564-0307

  • J. Schölzel, T. Beckhölter, S. Henn, C.Wüller, R. Streblow, D. Müller. Districtgenerator: A Novel Open-Source Webtool to Generate Building-Specific Load Profiles and Evaluate Energy Systems of Residential Districts. 37th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems.

  • C. Wüller, J. Schölzel, R. Streblow, D. Müller. Optimizing Local Energy Trading in Residential Neighborhoods:A Price Signal Approach in Local Energy Markets. 37th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems.

License

The DistrictGenerator is released by RWTH Aachen University, E.ON Energy Research Center, Institute for Energy Efficient Buildings and Indoor Climate, under the MIT License.

Acknowledgements

The districtgenerator has been developed within the public funded project "BF2020 Begleitforschung ENERGIEWENDEBAUEN - Modul Quartiere" (promotional reference: 03EWB003B) and with financial support by BMWK (German Federal Ministry for Economic Affairs and Climate Action).

Metadata

Release files for districtgenerator 1.0.1

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for districtgenerator 1.0.1
File Size Uploaded Provenance Actions
districtgenerator-1.0.1.tar.gz 10.7 MB Without provenance Details for districtgenerator-1.0.1.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for districtgenerator 1.0.1
File Interpreter ABI Platform Actions
districtgenerator-1.0.1-py3-none-any.whl Python 3 none any Details for districtgenerator-1.0.1-py3-none-any.whl

Total release size: 21.9 MB

Release files / districtgenerator-1.0.1.tar.gz

Download URL districtgenerator-1.0.1.tar.gz
Size 10.7 MB
Tags Source
SHA-256 checksum
How to use checksums
616a5f5743aa3716145ff4b1af73294832530d9d96d401b4d345cc5e346a7bd5
BLAKE2b-256 checksum
How to use checksums
48f2e12a6a0011f243e8141f99e6d4465c4078ab13e396ac1947eaf681945362
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.16

Release files / districtgenerator-1.0.1-py3-none-any.whl

Download URL districtgenerator-1.0.1-py3-none-any.whl
Size 11.2 MB
Tags Python 3
SHA-256 checksum
How to use checksums
b23d6c790421f06383d5e7048bf65e7c19271d6014f5d736d059e972205cfebd
BLAKE2b-256 checksum
How to use checksums
85dc0de32663addfe0c9730ea598c11506a2a8107a38feb43064fed420c210be
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/6.2.0 CPython/3.12.16

Security for districtgenerator 1.0.1

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Release history Release notifications | RSS feed

This release

1.0.1 This release

2 release files No provenance

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page