e3dc-ess-modbus

Read and control E3/DC home power stations over Modbus TCP.

Installation

pip install e3dc-ess-modbus "modbus-connection[tmodbus]"

It needs Python 3.12 or later and modbus-connection 4.12.4 or later. The examples use its tmodbus backend, which modbus-connection[tmodbus] installs.

Device setup

  • Protocol: turn Modbus on under Smart Functions > Smart Home > Modbus, and set Protocol to E3DC. SunSpec mode is not supported.
  • Connection: Modbus TCP, port 502 by default. The port is set in the same menu.
  • Unit ID: 1.
  • Firmware: grid control needs release 2025_06 or later, battery control 2025_40, the inverter operating mode 2025_43, and battery limits, stored energy and the battery power percentage 2026_04.
  • Supported devices: E3/DC home power stations such as the S10 E, S10 E PRO, S10 X and S20 X PRO, and systems on the Q10 and P10 firmware lines.
  • Network: the power station answers only clients in its own subnet.

Usage

The library builds on modbus-connection. You open the connection and pass the library a ModbusUnit. The library never opens or closes the connection itself.

import asyncio

from modbus_connection import ModbusTcpParams
from modbus_connection.tmodbus import ModbusConnection
from e3dc_ess_modbus import E3dcPowerStation


async def main() -> None:
    connection = ModbusConnection(ModbusTcpParams(host="192.168.1.50"))
    try:
        station = await E3dcPowerStation.async_detect(connection.for_unit(1))
        await station.async_update()
        print("PV:", station.power.pv_power, "W")
        print("Battery:", station.power.battery_soc, "%")
        print("Grid:", station.power.grid_power, "W")
        if station.battery_control is not None:
            await station.battery_control.async_write_battery_power(3000)
    finally:
        await connection.close()


asyncio.run(main())

Every value is None until the first update. Each update returns an UpdateReport. report.updated names the components that refreshed. report.failed maps the others to their error, and those keep their previous values. A lost connection raises ModbusConnectionError.

Gotchas

  • Request rate: the device accepts at most 10 requests per second. The library spaces its requests by 100 ms to stay under that.
  • Optional components: setup probes which components the firmware serves and logs the missing ones at INFO. Those it doesn't serve stay None.
  • Setpoints expire: the feed-in limit and the battery power lapse 30 seconds after the last write. The active power limit and the reactive power setpoints hold for the failsafe timeouts, 30 seconds by default. A timeout of 0 keeps them until the next write.
  • Holding a setpoint: a component's write method writes a setpoint once. To hold one, use SetpointHolds, which writes it again every 10 seconds until it is stopped. The *_setpoint attributes keep the last value written that the device acknowledged, as encoded. They don't clear when the setpoint lapses, only when the connection drops.
  • Reading back a write: a write doesn't refresh the cached values. Call await async_update_settings() to read back what took effect.
  • Two-register writes: the feed-in limit and the battery power go out as one FC16 write. If the device refuses FC16 as an illegal function, the library logs it once and sends two single-register writes from then on. Between those two writes, the register pair holds a value that is neither the old nor the new one. If the pair may be left that way, by an error or a cancellation, the library ends remote battery control, or writes the last feed-in limit back, before it raises. Writes to the battery and the feed-in limit wait for each other, so they reach the device in the order they were made.
  • Feed-in limit: feed_in_limit reads back the last value written. The limit in effect may differ.
  • Wallbox bits: which bits a wallbox uses depends on its model. Unused bits stay unset.
  • Testing: built against the vendor's Modbus TCP manual, version 2.80, and tested against modbus-connection's mock and an E3/DC one with firmware H20_2026_44.

API

E3dcPowerStation(unit, *, timeout=None)

An E3/DC home power station. timeout asks the connection for a per-request timeout, in seconds.

  • await async_detect(unit, *, timeout=None): build the device, read its identity and find out which optional components the firmware serves.
  • await async_update(): refresh every component.
  • await async_update_readings(): refresh what the device measures and reports on its own: power, DC strings, wallboxes, meters, power output and inverter mode status, battery limits and inverters.
  • await async_update_settings(): refresh the values that change only when written: the feed-in limit, the failsafe timeouts and the battery remote control flag.
  • await async_read_raw(): every register read, undecoded.
  • serial_number, model: from the identity block.
  • readings_components, settings_components: the components this firmware serves, once setup has run.
  • power_meter_readings: the eight meter slots as PowerMeterReading, keyed by slot 0 to 7.
  • identity, power, dc_strings, wallboxes, power_meters, wide_power_meters, grid_status, grid_control, battery_control, inverter_mode_control, battery_limits, inverters: the components below.

Numbered parts are mappings keyed by the manual's numbering: DC strings 1 to 3, and wallboxes, power meters and inverters 0 to 7.

identity (Identity)

  • manufacturer: the manufacturer name.
  • model: the model, such as S10 X.
  • serial_number: the serial number.
  • firmware_release: the firmware release, such as S10_2026_04.
  • modbus_version: the Modbus interface version, such as 2.3.

power (PowerFlows)

  • pv_power: solar power, in W.
  • battery_power: positive while charging, negative while discharging, in W.
  • house_power: house consumption, in W.
  • grid_power: positive while importing, negative while feeding in, in W.
  • additional_power: power from additional feeders, such as a second PV inverter, in W.
  • wallbox_power: wallbox power, in W.
  • wallbox_solar_power: the solar share of the wallbox power, in W.
  • battery_soc: state of charge, in %.
  • autarky: self-sufficiency, in %.
  • self_consumption: self-consumption, in %.
  • emergency_power_status: an EmergencyPowerStatus.
  • ems_status: EmsStatus flags.

dc_strings (DcStrings)

A mapping of string number 1 to 3 to DcString. The manual marks string 3 as not used.

  • voltage: string voltage, in V.
  • current: string current, in A.
  • power: string power, in W.

wallboxes (Wallboxes)

  • slots: eight Wallbox objects, in the order the device's wallbox configuration sets.
  • configured: the configured wallboxes, keyed by slot.

Each Wallbox has:

  • slot: its slot, from 0 to 7.
  • available: a wallbox is configured in this slot.
  • charging_allowed: charging is allowed. It reads the same bit as charging_aborted, inverted.
  • charging_aborted: charging is not allowed.
  • charging: a vehicle is drawing power. The wallbox sets this bit itself.
  • solar_mode: charging from solar only. Unset means hybrid mode.
  • one_phase: charging on one phase. Unset means three.
  • type2_plugged, type2_locked: the type 2 plug is plugged in, or locked.
  • schuko_on, schuko_plugged, schuko_locked: the type F socket is on, plugged in, or locked. Only the Wallbox classic can switch the socket.
  • relay_16a_1p, relay_16a_3p, relay_32a_3p: which relay is closed.
  • await async_write_charging_allowed(allowed): allow or abort charging.
  • await async_write_solar_mode(enabled): charge from solar only, or in hybrid mode.
  • await async_write_one_phase(enabled): charge on one phase, or on three.
  • await async_write_schuko_on(on): switch the type F socket on or off, on a Wallbox classic.

power_meters (PowerMeters)

  • meters: eight PowerMeter slots with meter_type and power_l1 to power_l3. Read them through power_meter_readings, which uses the 32-bit values when they refreshed in the last poll.

A PowerMeterReading has:

  • meter_type: a PowerMeterType, or None for an empty slot.
  • is_installed: a meter is configured in this slot.
  • power_l1, power_l2, power_l3: power per phase, in W.

wide_power_meters (WidePowerMeters)

Optional. Present when the firmware serves the 32-bit meter values.

  • sg_ready_status: the SG Ready status code. The manual documents no values.

grid_status (GridStatus)

Optional. Present on firmware 2025_06 or later.

  • power_output_ready: the inverter, DC-DC converter and battery can deliver power.

grid_control (GridControl)

Optional. Present on firmware 2025_06 or later.

  • feed_in_limit: the last feed-in limit written, in W.
  • active_power_failsafe_timeout: how long an active power setpoint holds, in s.
  • reactive_power_failsafe_timeout: how long a reactive power setpoint holds, in s.
  • active_power_limit_setpoint, active_power_failsafe_setpoint, reactive_power_failsafe_setpoint: the last values acknowledged, in %.
  • reactive_power_setpoint (var), cos_phi_setpoint, reactive_power_percent_setpoint (%): the last reactive power acknowledged, in the form it was written. The other two forms are None.
  • await async_write_feed_in_limit(watts): cap the power fed into the grid.
  • await async_write_active_power_limit(percent): cap the inverter's output, in % of rated power.
  • await async_write_active_power_failsafe(percent): the active power limit after a setpoint expires.
  • await async_write_reactive_power(var): set the reactive power, in var.
  • await async_write_reactive_power_percent(percent): set the reactive power, in % of rated apparent power.
  • await async_write_cos_phi(value): set the reactive power as cos φ, from -600 to 600.
  • await async_write_reactive_power_failsafe(percent): the reactive power after a setpoint expires.
  • await async_write_active_power_failsafe_timeout(seconds): how long an active power setpoint holds. 0 turns the failsafe off.
  • await async_write_reactive_power_failsafe_timeout(seconds): how long a reactive power setpoint holds. 0 turns the failsafe off.

battery_control (BatteryControl)

Optional. Present on firmware 2025_40 or later.

  • remote_control_disabled: register 40199. Writing 1 ends remote battery control at once. The manual says 0 has no effect.
  • battery_power_setpoint: the last battery power acknowledged, in W. None after a stop or a percentage write.
  • await async_write_battery_power(watts): charge (positive) or discharge (negative) at a fixed power.
  • await async_stop_remote_control(): hand control back at once, by writing 1 to 40199.
  • await async_write_remote_control_disabled(disabled): write 40199. True does what async_stop_remote_control() does.

On firmware 2026_04 and later, battery_limits sets the battery power as a percentage too.

inverter_mode_control (InverterModeControl)

Optional. Present on firmware 2025_43 or later.

  • inverter_mode_request: the forced inverter mode, an InverterModeRequest.
  • inverter_mode: the inverter mode in effect, an InverterMode.
  • await async_write_inverter_mode_request(mode): force an InverterModeRequest.

battery_limits (BatteryLimits)

Optional. Present on firmware 2026_04 or later.

  • max_charge_power: what the battery can take right now, in W.
  • max_discharge_power: what the battery can give right now, negative, in W.
  • remaining_energy: stored energy, in Wh.
  • full_charge_energy: capacity when full, in Wh.
  • battery_power_percent_setpoint: the last battery power percentage acknowledged. None after a stop or a watt write.
  • await async_write_battery_power_percent(percent): charge (positive) or discharge (negative) at a share of full power. The watt write is on battery_control.

inverters (Inverters)

Optional. Present when any inverter slot answers.

A mapping of slot number to Inverter, with every slot that answers its registers. Inverter 0 is the device's own. Slots 1 to 7 are for additional solar inverters, and an empty slot may answer with zeros. A slot that fails during setup stays absent until a new E3dcPowerStation sets up.

  • is_connected: the inverter reports a grid voltage.
  • active_power_l1 to active_power_l3: active power per phase, in W.
  • apparent_power_l1 to apparent_power_l3: apparent power per phase, in VA.
  • reactive_power_l1 to reactive_power_l3: reactive power per phase, in var.
  • voltage_l1 to voltage_l3: AC voltage per phase, in V.
  • current_l1 to current_l3: AC current per phase, in A.
  • frequency: grid frequency, in Hz.
  • dc_power_1 to dc_power_3: DC power per tracker, in W.
  • dc_voltage_1 to dc_voltage_3: DC voltage per tracker, in V.
  • dc_current_1 to dc_current_3: DC current per tracker, in A.

SetpointHolds(station, *, interval=10.0, on_change=None)

Keeps setpoints alive against the 30 second watchdog. One lock serializes starting, stopping and rewriting. With interval=None it runs no loop of its own, and the caller calls async_rewrite() every 10 seconds or less. An interval must be above 0 and at most 20 seconds. If the active power failsafe timeout (40194) is shorter than the interval, the active power limit lapses between rewrites. on_change is called whenever a hold changes, and an exception it raises is logged.

  • Setpoint: BATTERY_POWER (W), FEED_IN_LIMIT (W), ACTIVE_POWER_LIMIT (%).
  • get(setpoint): the Hold, a frozen snapshot with value, failing (the last rewrite failed), releasing (a hand-back failed and is retried) and confirmed (neither), or None.
  • requested(setpoint): the last value written or remembered, held or not.
  • remember(setpoint, value): remember a value for async_resume without writing it.
  • await async_start(setpoint, value): write a value and hold it. A failed write keeps the current hold, except a half-written one, which ends it. Raises E3dcError if the firmware lacks the setpoint's registers.
  • await async_resume(setpoint): hold the last requested value again.
  • await async_stop(setpoint): hand control back. The battery leaves remote control, the active power limit goes to 100 %, and the feed-in limit lapses within 30 seconds. A failed hand-back stays as releasing and is retried on each rewrite. A failed battery hand-back is dropped after 30 seconds, when the watchdog has dropped the setpoint anyway.
  • await async_rewrite(): write every hold again. A device refusing one setpoint doesn't stop the others. A connection error or timeout ends the pass, and the setpoints it skipped count as failing.
  • await async_close(timeout=5.0): hand everything back and refuse new holds. Waiting for a running rewrite and the hand-backs take at most timeout together. Afterwards nothing is held, even if a hand-back failed.

Enums

  • EmergencyPowerStatus: NOT_SUPPORTED, ACTIVE, INACTIVE, NOT_AVAILABLE, MOTOR_SWITCH_OFF.
  • EmsStatus (flags): CHARGING_LOCKED, DISCHARGING_LOCKED, EMERGENCY_POWER_READY, WEATHER_BASED_CHARGING, FEED_IN_LIMITED, CHARGE_LOCK_TIME, DISCHARGE_LOCK_TIME.
  • PowerMeterType: ROOT, EXTERNAL_PRODUCTION, BIDIRECTIONAL, EXTERNAL_CONSUMPTION, FARM, NOT_USED, WALLBOX, EXTERNAL_FARM, DATA_DISPLAY, CONTROL_BYPASS.
  • InverterModeRequest: DISABLE_OVERWRITE, FORCE_IDLE_OFF_GRID_POWER_SAVE.
  • InverterMode: INIT, IDLE_OFF_GRID_POWER_SAVE.

Errors

All errors the library raises itself derive from E3dcError. Transport and device errors come from modbus-connection.

  • NotAnE3dcError: the device refused the identity block, or didn't identify as an E3/DC power station in E3DC mode. Raised by async_detect() and the first update.
  • InvalidValueError: a value to write is out of range or of the wrong type. It is also a ValueError. Nothing is written.
  • InconsistentWriteError: on a device that refuses FC16, a two-register setpoint failed after its first half may have landed. The library has written 1 to 40199 for the battery power, or the last feed-in limit for the feed-in limit, and forgotten the setpoint.
  • HoldsClosedError: SetpointHolds was closed.
  • E3dcError itself: SetpointHolds was asked to hold a setpoint the firmware has no registers for.
  • NoSetpointError: async_resume has no value to hold.
  • ModbusConnectionError: the connection was lost.
  • ModbusTimeoutError: the device didn't answer before any component had refreshed.
  • ModbusExceptionError: the device refused a write, for example a setpoint on firmware that doesn't support it.

The register addresses are in the component modules under src/e3dc_ess_modbus, and in the vendor's Modbus TCP manual on the E3/DC customer portal.

Troubleshooting

script/query.py reads the device once and prints every value:

uv run script/query.py 192.168.1.50

Add --raw to include the undecoded registers. A bug report about a wrong value needs them.

The e3dc_ess_modbus logger reports at DEBUG the components setup settled on. It logs each refused block at INFO, and a refused FC16 write or a half-written setpoint at WARNING.

Metadata

Release files for e3dc-ess-modbus 0.1.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for e3dc-ess-modbus 0.1.0
File Size Uploaded Provenance Actions
e3dc_ess_modbus-0.1.0.tar.gz 69.6 kB With provenance Details for e3dc_ess_modbus-0.1.0.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for e3dc-ess-modbus 0.1.0
File Interpreter ABI Platform Actions
e3dc_ess_modbus-0.1.0-py3-none-any.whl Python 3 none any Details for e3dc_ess_modbus-0.1.0-py3-none-any.whl

Total release size: 103.0 kB

Release files / e3dc_ess_modbus-0.1.0.tar.gz

Download URL e3dc_ess_modbus-0.1.0.tar.gz
Size 69.6 kB
Tags Source
SHA-256 checksum
How to use checksums
d58b03200399bbeb126a95e898da5284ab337c8264dd0e726da283c715d31de8
BLAKE2b-256 checksum
How to use checksums
f866a3829bb361add8bc6f338ab326e7d54d14b6c516e5db84229c089172d76e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 1, 2026.

Transparency log

Release files / e3dc_ess_modbus-0.1.0-py3-none-any.whl

Download URL e3dc_ess_modbus-0.1.0-py3-none-any.whl
Size 33.4 kB
Tags Python 3
SHA-256 checksum
How to use checksums
9a188d57ed2675bb87819dc1fc20682fbcd74a3db858ea5d146cabe8e494ceaf
BLAKE2b-256 checksum
How to use checksums
9020a8037b7c5488779b20f0aedc4a97e81b70e655d88c544695b6d2196effcf
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 1, 2026.

Transparency log

Security for e3dc-ess-modbus 0.1.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for e3dc_ess_modbus-0.1.0.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 1, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Release history Release notifications | RSS feed

This release

0.1.0 This release

2 release files Full provenance

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page