ebus-panel-sim

PyPI CI Python versions Ruff eBus spec License: MIT

A fully-loaded, spec-conformant distribution-enclosure simulator and producer-side Homie 5 publisher for the eBus convention. It publishes a complete eBus Homie device tree (the enclosure plus a device for every circuit, lugs pair, and integrated DER: BESS, PV, EVSE, and MID) so external developers can build and test their consumers against a realistic SPAN-like panel without beta firmware, a live panel, or the commissioned add-ons (SPAN Drive/EVSE, BESS, PV, MID) a real installation would have.

It serves two roles:

  • Simulator / test fixture. Drive it from a small YAML definition and it publishes a spec-conformant, fully-commissioned enclosure to any MQTT broker. Consumers (Home Assistant integrations, dashboards, SDK code) validate against it before shipping to the field.
  • Producer library. The canonical eBus Homie publisher. A producer (a simulator, a real panel gateway, an LLM-driven model) hands the emitter a small per-tick driving signal (signed power per circuit, current time, grid-online flag, and optionally the panel's link health to each battery, the PV a battery's own inverter takes and the production of PV inverters no circuit feeds) via TickInputs; the emitter derives all telemetry and publishes Homie-conformant retained MQTT with diff-only updates. The split is identity = manifest (once at startup), telemetry = derived from TickInputs (per tick).

For the internals (the per-tick pipeline, the native BESS/load-shed devices, /set handling, the wire model) see DESIGN.md; for the dev setup see DEVELOPER.md.

Requirements

  • Python >= 3.11
  • uv
  • An MQTT broker reachable at localhost:1883 (plaintext). The companion broker-quickstart bundle brings one up in one command; any mosquitto works too.

Install

pip install ebus-panel-sim    # or: uv add ebus-panel-sim

The import package is ebus_panel_sim. During local development, pin a path instead:

ebus-panel-sim = { path = "../distribution-enclosure-simulator", editable = true }

It depends on ebus-sdk.

Before 0.3.0 this package was named panel-sim, importing as panel_sim, and was installable only from git. Update both the dependency and your imports.

Run

The repo ships a runnable example: it builds an emitter from a panel definition, publishes its three ticks (the last with the grid down) to an MQTT broker, then reads the retained tree back through an ebus-sdk Controller and prints it. It expects a plaintext broker on localhost:1883.

The quickest broker is the companion broker-quickstart in its open profile (plaintext, anonymous, port 1883):

# in a broker-quickstart checkout — a plaintext :1883 broker (anon read + write)
python -m laptop.run --profile open

Then, in this repo, publish to it and print the retained tree:

uv sync --group dev
uv run python examples/run_forty_tab_minimal.py                        # print the retained tree
uv run python examples/run_forty_tab_minimal.py --broker 127.0.0.1:1883 > tree.txt

Any broker that accepts anonymous connections on localhost:1883 works; --broker host:port points the example elsewhere.

The definition is examples/forty_tab_minimal.yaml, driven by examples/forty_tab_minimal.ticks.yaml: a fully-commissioned enclosure with circuits, upstream/downstream lugs, a BESS (plus its MID), PV, and SPAN Drive EVSEs. Each node is its own Homie device: the enclosure at ebus/5/<enclosure-id>/… and each circuit, lugs pair, and DER at its own topic root, for example ebus/5/<circuit-id>/switch/relay, ebus/5/<lugs-id>/meter/current-a, ebus/5/<bess-id>-mid/grid/islanding-state.

Configure

The simulator is driven by a config that says which enclosure, which add-ons, and which circuits. There are two entry points.

1. Example definition

examples/forty_tab_minimal.yaml is the quickest path: a panel definition file (see "Panel definition file" below) listing each device with its metadata, plus the BESS dispatch settings. A DER sits on a circuit by naming it in its feed (the two PV inverters each sit on a commissioned-system: pv circuit), and the MID, the islanding authority of a grid-forming BESS in an islandable enclosure, is listed under the BESS as on a real SPAN panel. examples/forty_tab_minimal.ticks.yaml is the per-tick driving signal: signed watts per circuit, EVSE draw, and the grid-online flag. Copy and edit both, or generate them from a live panel with panel-sim-capture. examples/span_alpha_test_b2_minimal.yaml and its ticks do the same for a span-alpha-test-b2 panel.

2. DeviceManifest (programmatic)

A producer can build DeviceInstances directly instead of loading a definition file. Each device class's identity and static attributes live in the instance's metadata, validated once at startup by ManifestPhysicsView (missing required keys or malformed values raise ManifestValidationError naming the offending instance). The metadata keys per device class:

entity_class required keys optional keys
panel vendor-name, serial-number, firmware-version (or software-version), hardware-version, panel-size, panel-model, postal-code, time-zone wifi-ssid (reported unless a tick's envelope gives one), off-grid-import-limit-enablement (UNSPECIFIED, UNCONFIGURED, DISABLED or ENABLED; absent: no off-grid limit property is published), off-grid-import-limit-a (published only while ENABLED, and then required), operator-import-limit-enablement (UNCONFIGURED), main-breaker-rating-a (absent: no breaker capability), service-voltage-v (240), line-voltage-v (120), islandable (false), schema-topology (flat | parent-child), site-name, address-lines, locality, region, country-code, latitude, longitude, utility-meter-serial-number
lugs direction (upstream | downstream) feeds-role, backed-up, service-rating-a, overcurrent-protection-a
circuit tab-numbers (CSV ints), breaker-rating-a, default-priority, relay-behavior (controllable | non-controllable | always-on), placement (upstream-of-lugs | downstream-of-lugs) always-on, never-backup (false), commissioned-system (pv | backup), dipole (defaults to len(tab-numbers) > 1), pcs-priority (0), initial-consumed-wh (0), initial-produced-wh (0), tags, locations, dedicated, nominal-voltage, protection-functions, shared-with-device-ids, feeds-role, backed-up
bess vendor-name, nameplate-capacity-kwh model, part-number, serial-number, firmware-version/software-version, relative-position (UPSTREAM), feed, initial-soe-kwh, inverter-type (ac-coupled; hybrid when the battery's inverter also takes PV)
pv vendor-name, nominal-power-w (a finite number greater than 0), inverter-type (hybrid | ac-coupled) model, serial-number, firmware-version/software-version, relative-position (IN_PANEL), feed
evse vendor-name, model, part-number, serial-number, firmware-version (or software-version), max-current-a feed, user-max-charge-current-a (the user limit it starts from, as if set)
mid (none) vendor-name, serial-number, model, firmware-version/software-version, hardware-version

A circuit's tab-numbers are the panel spaces it occupies, numbered odd down the left column and even down the right, with the legs alternating by row: spaces 1 and 2 are on L1, 3 and 4 on L2, and so on. A tab's leg follows from its number alone, so on a panel whose spaces start at 9, 9 and 10 are on L1. A two-pole circuit takes two spaces one above the other in a column, such as 1,3, which span both legs. A two-pole circuit on any other footprint is rejected: one space; two of one row, such as 1,2, which share a leg; two of one column that are not adjacent, such as 1,5, which share a leg, or 1,7; two in different columns, such as 2,3 or 1,4; or three or more. panel-sim-capture raises CaptureError for a tree that publishes one, or a circuit whose breaker/poles is not 1 or 2. A panel numbered sequentially down one column, which the eBus specification also allows, puts its two-pole circuits on consecutive spaces, so its definition must be renumbered odd down the left and even down the right. The lugs' meter/current-a and meter/current-b are the magnitude of each leg's net current, so a circuit feeding back offsets the loads on its leg.

A circuit whose relay-behavior is non-controllable or always-on — or which carries always-on: true — is locked: its relay refuses /set, is exempt from load-shed, reports switch/relay-requester as CONFIGURATION, and declares no $settable on switch/relay. The two spellings differ only in the operator's intent; the hardware this models carries one flag, publishing switch/relay-controllable as its inverse. Locking reaches the relay only — a locked circuit still declares load-shed/priority settable.

A circuit carrying never-backup: true is commissioned to receive no backup power: it is permanently OFF_GRID, so its default-priority must be OFF_GRID (any other value is rejected as contradictory), it declares no $settable on load-shed/priority, and a /set on that priority is refused. It still sheds when the panel islands — that is what being OFF_GRID means; what the lock removes is the consumer's ability to re-prioritise it. That shed publishes switch/relay-requester as LOAD_SHED, like any other shed — the lock is not a requester value — and at rest the circuit reports NONE like any other. This is a separate commissioning input from the priority value: default-priority: NEVER means "never shed" and stays fully settable, which is what real panels publish.

A circuit carrying commissioned-system: pv or commissioned-system: backup is the circuit a SPAN panel adds for a commissioned PV or battery system. It locks both: the relay as above, and load-shed/priority, which must be NEVER (any other default-priority is rejected).

A circuit carrying shared-with-device-ids, the comma-separated ids of the other circuits on its breaker, is one of the circuits a multi-load breaker (a tandem or quad) protects behind one CT and one relay. A variant whose circuit profile declares both meter/shared-with-device-ids and switch/shared-with-device-ids publishes such a breaker as one circuit device per protected circuit, as SPAN does wherever it publishes those lists (spanio/SPAN-API-Client-Docs#21): each circuit names the others in both, and every one publishes the breaker's one reading, which a consumer counts once. Its power is the sum of the circuits' loads, each of which a tick gives as that circuit's own; its energy accumulates once in one register, published on every circuit; and its current is the sum of the circuits' currents in one space or, across two, the larger leg, a single-pole circuit's current lying on its own space and a two-pole circuit's on both. Each circuit keeps its own breaker/rating, breaker/poles and info/spaces, a single-pole circuit listing its one space and a two-pole circuit both: a quad is two two-pole circuits each listing both spaces, a tandem-quad two single-pole circuits and a two-pole one. The breaker has one relay, which shedding acts on, so they share its state (capabilities/switch.md, "Shared switching hardware"): a /set of switch/relay or load-shed/priority on any of them, through the emitter's own handlers, applies to all of them, as does emitter.relays.set_user_override. Every circuit must name every other, they must agree on what one meter, relay and position fix (initial-consumed-wh, initial-produced-wh, the relay's lock however relay-behavior, always-on or commissioned-system sets it, default-priority, never-backup and placement), and they must sit where one breaker can, in one space or in the two spaces of a two-pole circuit on it, or the definition is rejected. This is the eBus shared-hardware declaration (capabilities/meter.md, "Shared metering hardware"); the specification also models such a breaker as a feed circuit above load circuits that carry only their breakers (devices/circuit.md, "Multi-load breakers"), which SPAN plans to move to and no variant publishes yet. The span variant models MAIN 32, which publishes one circuit per breaker space and no shared lists, and neither it nor the reference variant declares either list, so both publish each circuit's own load whatever the key says.

A bess carrying inverter-type: hybrid has an inverter that also takes PV on its DC side, as solar DC-coupled into a battery's inverter is. That PV never passes through a circuit, so the producer gives it per tick in TickInputs.bess_pv, which maps the id of a battery configured with a BESSConfig to the watts its PV input produces, positive while producing (a standby draw is negative). A battery left out produces none, and a tick naming a battery that is not hybrid or not configured, or giving a value that is not a finite number, raises EmitterStateError. In every variant power-flows/pv adds this PV to the solar the circuits carry, and the battery's dispatch sees it as solar. It leaves the battery's AC terminals together with the dispatch, so the grid is derived from the upstream lugs less both, while the lugs themselves carry only the circuits. Off grid the battery only discharges and the emitter curtails nothing, so there the four flows balance only while the solar is no more than the load and the battery covers the rest; curtailing any surplus is the producer's, as generating it is. The battery's own meter/active-power and power-flows/battery stay its charge and discharge. Capture r202639-f is such a panel: its battery is upstream of the lugs, and it reports its solar in power-flows/pv with no SOLAR circuit and no pv device.

A pv device that no circuit feeds (it has no feed) is taken to join the site upstream of the main lugs, whatever its relative-position or inverter-type, as AC-coupled solar behind a battery gateway does: that is the one place in this model that is neither a circuit nor the downstream lugs, which carry only downstream-of-lugs circuits. Its production never passes through a circuit, so the producer gives it per tick in TickInputs.pv, which maps the id of such a pv device to the watts it produces, positive while producing (a standby draw is negative). An inverter left out produces none, and a tick naming an id that is not a pv device, a pv device that a circuit feeds (that circuit's power already carries its production), or giving a value that is not a finite number, raises EmitterStateError before anything moves. In every variant that allows pv devices, power-flows/pv adds this production to the solar the circuits and any hybrid battery carry, and the battery's dispatch sees it as solar. The grid is derived from the upstream lugs less the battery's dispatch, any hybrid battery's PV and this production, while the lugs, the circuits and site are unchanged, and no relay gates it. Off grid the battery only discharges and the emitter curtails nothing, so there the four flows balance only while the solar is no more than the load and the battery covers the rest; curtailing any surplus is the producer's, as generating it is. A pv device still publishes only its info: its production is published nowhere on its own, only within the panel's flows.

A remote-ct instance (no metadata) is a meter on the service conductor, outside the panel. It is published only by span-alpha-test-b2, at most one per panel, as a circuit device with a meter and no info, and so no info/spaces; before release 202645 it has only the meter, and from that release also a connection node holding only connection/connection-point MONITORED, which is how a consumer tells it from a branch circuit. Its active-power is the utility-side grid power, positive on import, and imported-energy grows on import.

From SPAN release 202645 (the panel's firmware-version, or none named), span-alpha-test-b2 declares connection/connection-point on every circuit: BRANCH on a branch circuit and MONITORED on the remote-ct, whose connection node carries only that property. Leave the downstream lugs row out for a panel without a feedthrough module, which that release publishes without downstream lugs. Identify devices by $description.type and their properties, never by their IDs.

Under span-alpha-test-b2, a locked relay also locks load-shed/priority, and commissioned-system is rejected: that variant publishes a PV or battery breaker as an ordinary circuit with a locked relay at NEVER. Its solar is a circuit with feeds-role: SOLAR or a hybrid battery's PV input, never a pv device (a pv instance is rejected). The flows follow r202639 firmware: power-flows/pv is the SOLAR circuits' powers summed with any hybrid battery's PV, negative while producing; power-flows/battery adds the powers of STORAGE circuits and a battery's own breaker to the battery's dispatch (so a BESS's feed circuit should read 0 in ticks, as captured ticks leave it); power-flows/site is the circuits with no role, LOADS or UNUSED (a surveyed, empty breaker), and a circuit feeding an EVSE whatever its role; with neither a SOLAR circuit nor a battery, pv and battery are unset. A circuit's power here is its own load as the tick gives it, which on a shared breaker is not the breaker's reading the circuit publishes; no capture shows which of the two the firmware books. A STORAGE circuit is metered only: no battery stands behind it, so off-grid the panel islands as one without a battery (no line voltage, no battery as the dominant source); give the battery as a bess device to model backup. A circuit with the GENERATOR, SUBPANEL or MIXED role is rejected, since no rule is known for how it is booked; panel-sim-capture still captures such a panel, keeps the role, and reports a note naming the circuit. A remote-ct meter would add the load it measures upstream of the panel to site, but this emitter's remote-ct reads the panel's own grid power. A third-party backup system that reports the site's flows from its own meter, as captures r202639-c and r202639-f show (their grid and site are not what the panel's lugs and circuits add up to), is modelled only as far as its battery and its inverter's PV: the emitter derives grid from its lugs and batteries and site from its circuits. No reference capture has a SOLAR-role circuit, so these tests carry the spec_only marker.

The keys from site-name on the panel row, from tags on the circuit row, and every optional lugs key are commissioning facts, checked against the datatype of the property they feed and published verbatim (a number keeps the digits it is written with), only by a variant whose profile declares that property (today span-alpha-test-b2). A key absent from the manifest leaves its property unpublished.

The span variant publishes the way the panel's firmware-version says its SPAN firmware did. The release build is the first /-separated segment that is exactly r plus six digits, so spanos2/r202633/02 is release 202633. Before release 202639 the BESS's meter/active-power is the panel's reading of the battery, equal to power-flows/battery (positive while charging), and each EVSE's config/user-max-charge-current is published at its max-current-a until a user sets one. From release 202639, or for a string naming no release such as the examples' example/v0.1.0, the BESS meter is the battery's own frame (positive while discharging, the negative of power-flows/battery) and the user limit is unpublished until set. span-alpha-test-b2 always publishes the latter, whatever its firmware. The reference variant always publishes the battery's own frame and declares no config/user-max-charge-current at all.

3. Panel definition file

A PanelDefinition holds everything that fixes a panel's makeup: the DeviceManifest, the variant, the native BESSConfigs and an optional LoadSheddingConfig. dump_definition and load_definition write and read it as YAML, and Emitter.from_definition builds an emitter from one:

schema: panel-sim-definition/1
variant: span
devices:
  - class: panel
    id: abc-123
    name: Span Panel
    metadata: {vendor-name: Span, serial-number: abc-123, ...}
  - class: circuit
    id: kitchen
    name: Kitchen
    metadata: {tab-numbers: "1", breaker-rating-a: "20", ...}
bess:
  - {instance_id: abc-123-bess, nameplate_capacity_kwh: 13.5, max_charge_w: 3500.0, max_discharge_w: 3500.0}
load_shedding: {soc_threshold_pct: 20.0}
from ebus_panel_sim import Emitter, SetterRegistry, load_definition

emitter = Emitter.from_definition(load_definition("panel.yaml"), SetterRegistry())

A device may also give a description_name, which it publishes as its $description.name in place of name; a circuit still publishes name as info/name. The MAIN 32 capture on release 202639 names each child device by its device ID there. Each device's metadata takes the keys in the table above, read exactly as written (postal-code: 02134 stays 02134), and any device also takes unvalued: a comma-separated list of the properties it declares in its $description and never values (soc/soc,soc/soe for a battery whose charge the panel does not report), each one its profile must declare. bess and load_shedding take the fields of BESSConfig and LoadSheddingConfig, converted to their types. An unknown key, a non-scalar metadata value, or a field of the wrong type is an error.

4. Capture a definition from a published panel

panel-sim-capture reads a distribution enclosure's published tree and writes a panel definition that reproduces it:

panel-sim-capture --host <broker> --username <user> --password <pw> --cafile <broker-ca>.crt -o panel.yaml
panel-sim-capture --from-snapshot snapshot.json -o panel.yaml   # a tree-v1 snapshot file

Live capture connects over TLS on port 8883 by default and needs either --cafile to verify the broker or --insecure to skip verification (--no-tls and --port otherwise). It returns once the tree is complete and has settled, or after --timeout seconds with a warning that it is incomplete. Only the distribution enclosure's own device tree is read; --root names it when the broker carries more than one. Serial numbers, device IDs, the postal code and the Wi-Fi SSID are masked unless --no-mask is given. Circuit names are kept as published; --generic-names replaces them with Circuit 1, Circuit 2, ... in tab order. A device the panel names by its own ID, rather than by its name, is written with that (masked) ID as its description_name. A property a device declares and leaves unvalued is written to its unvalued list only if the emitter would otherwise publish it: the capture republishes the definition once without the lists, driven by one tick sampled from the tree, and drops every path that stays unvalued anyway. A settable property is left out, since a consumer may set it later. The variant is span-alpha-test-b2 for a panel whose hardware version string selects it, span for any other SPAN panel, and reference otherwise, unless --variant says. Under span-alpha-test-b2 the commissioning keys are read back (masking replaces the site's name, address, coordinates and utility meter serial with placeholders, so they stay valued), and a circuit device with only a meter is captured as a remote-ct.

A published tree does not carry everything a definition holds. Each value the capture had to default is reported on stderr: BESS charge and discharge limits and charge mode, a PV inverter's or a battery's coupling, panel size where the model name does not give it, and tabs where info/spaces is not published (the reference variant). What a definition cannot express is reported and left out: upstream lugs fed by another enclosure, and a MID on a panel without exactly one battery. Captured circuits are placed upstream-of-lugs, inside the panel; a battery on a panel breaker stays on it (relative-position: IN_PANEL). The solar the panel's power-flows/pv reports beyond what its circuits carry, as the variant the panel's hardware version selects books them, is written where the tree's topology puts it. The decision comes from the tree's devices and connections and from whether its panel publishes a pv flow, never from a reading: a tree captured at zero, under a watt or at a standby draw decides as a sunny one does, and its figure is only quoted in the notes. Where the tree holds pv devices that no circuit feeds, it is their production, whether or not its panel publishes a pv flow: such an inverter is taken to join the site upstream of the main lugs, and each takes a share in proportion to its published info/nominal-power, with a note saying so, since the panel publishes only the total; the shares add back to that solar exactly. Inverters publishing the same figure split it equally, to within float rounding, as capture main32_r202639-upstream-pv shows, whose two inverters each publish 11680. A circuit-fed pv device or a producing circuit does not stand in the way, since its production is in the circuits already, and no battery is written hybrid. Whatever the tree reads, the solar is reported and left out where the upstream lugs are fed by another enclosure, since a chained panel's pv may report the chain's solar; where downstream lugs name a pv device in connection/feeds-device-id, which puts it on the feedthrough side; where lugs feed SOLAR or MIXED, which could bring it; or where one of those inverters publishes no info/nominal-power, or one that is not a finite number greater than 0, to divide it by. The definition gives any pv device publishing such a rating the default nominal-power-w, 5000, that it gives one publishing none, and notes the value it could not use. Where the tree holds no such inverter and its panel publishes a pv flow, whatever its value, a battery is written inverter-type: hybrid when nothing else in the tree could bring solar to the panel (no pv device, no circuit whose connection/feeds-role is SOLAR, under any variant, and no lugs feeding SOLAR or MIXED; a producing circuit does not stand in the way, since its production is in the circuits already), and the battery is the tree's only one: that solar reaches the panel through the battery, and the panel does not say whether it is DC-coupled to the battery's inverter or AC-coupled behind its gateway, which reach it alike. Such solar on any other panel that publishes a pv flow is reported and left out, and a --variant other than the one the hardware selects is noted, since the ticks' battery PV and inverters' production are still derived as the latter books circuits. The off-grid SOC shed threshold comes from the published shed/policy. --record N --ticks-output ticks.yaml also samples a live panel N times, --interval seconds apart, and writes the samples as replayable ticks (schema: panel-sim-ticks/1): each circuit's published power negated back to the producer's sign (circuits that share a meter, publishing its one reading, each given an equal share of it, as below), each EVSE drawing what the tick gives its feeding circuit (a circuit feeding a battery is left out, since the simulated battery's dispatch accounts for it), each battery's link from its status/communication-state, a hybrid battery's PV, or the production of the pv devices no circuit feeds split by the shares the tree gives them, from the solar the sample's power-flows/pv reports beyond what the tick's circuits carry (signed and at any size, so zero gives 0, a fraction of a watt that fraction and a standby draw a negative figure, whatever the tree read, and a sample that publishes no pv gives none), and the grid offline when the MID reports OFF_GRID (or, without a MID, the main relay is open). load_ticks reads them back:

emitter = Emitter.from_definition(load_definition("panel.yaml"), SetterRegistry())
emitter.start()
for tick in load_ticks("ticks.yaml"):
    emitter.publish_tick(tick)

A tick entry's keys are current_time and grid_online (both required), circuits and evse (watts by id), and, written only where the tick gives them, bess_communication (a battery's link state by id), bess_pv (the watts a hybrid battery's PV input produces, by battery id) and pv (the watts a pv device that no circuit feeds produces, by the device's instance id, positive while producing and negative for a standby draw). A key outside these, or a value that is not a finite number (or, for a link, not a link state), is a ManifestValidationError.

Under a variant whose circuit profile declares both shared-with-device-ids lists, a panel publishes a shared breaker's one reading on each of its circuits and nothing of each circuit's own load, so the capture gives each an equal share, of their mean should the readings differ, read a moment apart. The shares add back to the reading, to within float rounding, so the breaker's meter republishes its power and energy, and its current in one space or across two where every circuit on it is two-pole. On a tandem or quad whose circuits book into the same flow, the flows and lugs, which the emitter takes from each circuit's own load, republish too, whichever way each circuit draws, since a leg's currents add with their signs. What depends on how the load divides cannot be reproduced:

  • circuits whose roles book them into different flows, such as a SOLAR circuit sharing a breaker with a load: power-flows/pv and power-flows/site each take half the net reading, and the lugs and busbar follow them;
  • a tandem-quad: its meter reads the mean of its two spaces instead of the larger, as little as half, and the lugs' legs move;
  • an EVSE fed by a circuit on a shared breaker draws that circuit's share, not its own load;
  • a battery's circuit on a shared breaker is left out, as every battery circuit is, so the others' shares carry the battery's flow, which its dispatch counts again.

Under span and reference, which publish each circuit's own load, each circuit keeps the reading it published; ticks_from_samples takes the definition's variant for this, and the command line passes it.

A circuit's shared-with-device-ids keeps only the other circuits in the tree, each entry read without the spaces around it, with a note counting any it drops. Under a variant declaring both lists, the circuits on one breaker are each seeded with the largest register any of them publishes, since it only rises, and circuits that do not all name each other are a capture error. Any other definition the emitter refuses is a CaptureError, except one with a circuit role span-alpha-test-b2 cannot book, which is captured with a note.

ebus_panel_sim.capture exposes the same steps as functions (capture_live, tree_from_snapshot, tree_from_retained, definition_from_tree, ticks_from_samples).

5. Replay a reference capture

The package ships masked captures of real SPAN panels as package data: r202639-a to r202639-e, main32_r202639 and main32_r202639-upstream-pv (a MAIN 32 with its PV inverters and battery upstream of the panel), each a panel on spanos3/r202639/03; r202639-f, a panel on spanos3/r202639/04 whose solar is DC-coupled into its battery's inverter; main32_r202633, a MAIN 32 on spanos3/r202633/02; and six panels on spanos3/r202645: main32_r202645 and r202645-a, -c and -e, the panels of main32_r202639 and r202639-a, -c and -e on the later release (r202645-a with its remote CT) (r202645-c recommissioned with different circuits and no battery), and main32_r202645-cascade (a MAIN 32 fed by another panel) and r202645-g (a MAIN 16 with a battery and a SPAN Drive). A panel keeps its masked serial from one capture to the next, so a pair's trees can be compared device by device: on release 202645 a span-alpha-test-b2 panel's circuit and lugs device IDs change, and it publishes one lugs device where it has no feedthrough, so align circuits by info/spaces and info/name, and lugs by info/direction. reference_capture_names() lists them, and load_reference_capture(name) reads one as a ReferenceCapture: the tree the panel published (a Tree of Devices, as ebus_panel_sim.capture reads one), and a definition (a PanelDefinition) and ticks that republish it. derived_from_tree says where those two come from. It is False when they were recorded with the capture. It is True for main32_r202633 and r202639-f, each a tree alone: the definition is what definition_from_tree(tree, mask=False) writes (the tree is masked already) and the ticks are one tick sampled from the tree, the captured instant. Their notes (CaptureNotes) say what that definition had to default, leave out or read from the flows, as panel-sim-capture reports them, such as main32_r202633's upstream lugs being fed by another enclosure and r202639-f's battery being written hybrid; a recorded capture's notes are empty. Every call reads the files afresh, so the result is the caller's to change. Any other name raises UnknownReferenceCaptureError, a LookupError.

from ebus_panel_sim import Emitter, SetterRegistry, load_reference_capture

capture = load_reference_capture("r202639-a")
emitter = Emitter.from_definition(capture.definition, SetterRegistry())
emitter.start()
for tick in capture.ticks:
    emitter.publish_tick(tick)

The emitter reproduces each capture's tree but for the differences tests/test_reference_capture_fidelity.py lists, each with its reason.

Usage (as a producer library)

import time

from ebus_panel_sim import (
    BESSConfig, DeviceInstance, DeviceManifest, Emitter,
    LoadSheddingConfig, SetterRegistry, TickInputs,
)


def main() -> None:
    manifest = DeviceManifest(instances=(
        DeviceInstance("panel", "abc-123", "Span Panel", metadata={
            "vendor-name": "Span", "serial-number": "abc-123",
            "firmware-version": "sim/v0.1.0", "hardware-version": "rev2",
            "panel-size": "40", "main-breaker-rating-a": "200",
            "panel-model": "MAIN_40", "postal-code": "94103",
            "time-zone": "America/Los_Angeles", "islandable": "true",
        }),
        DeviceInstance("lugs", "abc-123-lugs-up", "Upstream lugs", {"direction": "upstream"}),
        DeviceInstance("circuit", "kitchen", "Kitchen", metadata={
            "tab-numbers": "1", "breaker-rating-a": "20",
            "default-priority": "NICE_TO_HAVE", "relay-behavior": "controllable",
            "placement": "downstream-of-lugs",
        }),
        DeviceInstance("bess", "abc-123-bess", "Battery", metadata={
            "vendor-name": "Span", "nameplate-capacity-kwh": "13.5",
        }),
    ))
    bess_cfg = BESSConfig(instance_id="abc-123-bess", nameplate_capacity_kwh=13.5,
                          max_charge_w=3500.0, max_discharge_w=3500.0)

    # With mqtt_cfg the emitter owns the MQTT connection: ebus-sdk builds the
    # client and sets the enclosure's LWT. (Injecting your own client instead
    # moves both of those to you — see "Bring your own transport" below.)
    # Empty SetterRegistry -> the emitter installs internal default /set
    # handlers; register your own before construction to override them.
    emitter = Emitter(
        manifest, SetterRegistry(),
        mqtt_cfg={"host": "127.0.0.1", "port": 1883},
        bess_configs=(bess_cfg,),
        load_shedding_config=LoadSheddingConfig(soc_threshold_pct=20.0),
    )
    emitter.start()
    try:
        while True:
            emitter.publish_tick(TickInputs(
                current_time=time.time(),
                grid_online=True,
                circuits=collect_powers_from_your_model(),  # instance_id -> signed watts
            ))
            time.sleep(1.0)
    finally:
        emitter.stop()


main()

To model the panel losing its link to a battery, report it in the tick: TickInputs(..., bess_communication={"abc-123-bess": "LOST"}). The battery publishes it as status/communication-state, the connection status of the circuit or lugs connecting it follows, and while a battery link is not known to be healthy (before the first tick, or while any link is not OK) the emitter's own handler accepts an asserted-islanding-state write, clearing it once every link has been OK for 30 seconds (see DESIGN.md).

Read the most recently published state back through emitter.last_snapshot. mqtt_cfg is handed straight to ebus-sdk: beyond host/port it takes the ebus-mqtt-client TLS and authentication keys for secured brokers (e.g. broker-quickstart's mTLS discovery/strict profiles).

Bring your own transport

A host that already owns an MQTT connection can publish through it instead of having a second one opened underneath: pass Emitter(..., mqttc=client) in place of mqtt_cfg=. The two are mutually exclusive. This mirrors ebus-sdk's own Device(mqttc=...), and the case it exists for is a host like a Home Assistant add-on, whose MQTT integration is single_config_entry and which forbids background threads (ebus-mqtt-client 0.4.0's asyncio_driver() pumps paho's loop on yours).

The emitter never starts or stops a client it did not build. Two things it consequently cannot do for you — register the Last Will, and re-announce the tree on reconnect — are automatic on the mqtt_cfg path and yours here. They are steps 1 and 4 below, and the order is forced rather than stylistic:

from ebus_panel_sim import Emitter, SetterRegistry
from ebus_mqtt_client import MqttClient

# 1. The Last Will must exist before the client connects — it rides the CONNECT
#    packet, so it cannot be attached afterwards. This is why it is a
#    staticmethod: there is no Emitter yet, and cannot be.
lwt = Emitter.lwt_settings(manifest)

# 2. Build your client with it, still unconnected.
client = MqttClient.from_config({"host": "127.0.0.1", "port": 1883}, client_id="my-host", lwt=lwt)

# 3. Now the emitter, publishing through it.
emitter = Emitter(manifest, SetterRegistry(), mqttc=client)

# 4. Re-announce the whole tree on every (re)connect. Assigned after construction
#    rather than passed to from_config, because the callback needs the emitter and
#    the emitter needs the client. Invoked with no arguments.
client.on_connect_callback = emitter.republish_tree

# 5. You connect, not the emitter — it never starts a client it did not build.
client.start()
emitter.start()           # returns immediately; it has no connection to wait for

To pump paho on your own event loop instead of its background thread — the case a Home Assistant add-on needs — replace step 5's client.start() with the driver, which is async and mutually exclusive with start():

driver = client.asyncio_driver()   # must be called from inside a running loop
await driver.start()
emitter.start()

What each buys, and one obligation that is about timing rather than wiring. All three are silent when they bite:

  • No will means no liveness signal. Skip step 1 and the tree has no LWT at all: a host that dies leaves every consumer reading a stale retained ready, indefinitely. stop(graceful=False) publishes $state=lost itself, but that only covers an orderly teardown — the case where the process didn't die.
  • No re-announce means the tree does not come back. Skip step 4 and a broker that loses its retained store never sees the tree again; what returns is whatever later ticks happen to republish. Measured after wiping a real broker's retained store: 5 topics of 56, every $description missing.
  • Let your loop turn before you close the client. stop(graceful=False) queues the lost on your loop rather than flushing it — flushing would block the very thread that has to run loop_write. Closing the client in the same synchronous breath drops the message and leaves the retained tree on ready.

Layout

  • src/ebus_panel_sim/ — the package (emitter.py, manifest.py, wire/ profiles + publishing, native_devices/, reference_captures/); see DESIGN.md.
  • examples/ — the runnable example and its YAML definition.
  • tests/ — the pytest suite.

Tests

uv run pytest
uv run mypy --strict src/ebus_panel_sim tests
uv run ruff check src tests

Contributing

Contributions are welcome. See CONTRIBUTING.md for how to file issues, start a discussion, and open pull requests, plus the local quality gates (ruff, mypy --strict, pytest).

Credits

A fork of, and building on, the original simulator created by Bill Flood (@cayossarian); since updated to track the latest eBus specification. See AUTHORS.

License

See LICENSE.

Metadata

Release files for ebus-panel-sim 0.11.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for ebus-panel-sim 0.11.0
File Size Uploaded Provenance Actions
ebus_panel_sim-0.11.0.tar.gz 509.1 kB With provenance Details for ebus_panel_sim-0.11.0.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for ebus-panel-sim 0.11.0
File Interpreter ABI Platform Actions
ebus_panel_sim-0.11.0-py3-none-any.whl Python 3 none any Details for ebus_panel_sim-0.11.0-py3-none-any.whl

Total release size: 827.1 kB

Release files / ebus_panel_sim-0.11.0.tar.gz

Download URL ebus_panel_sim-0.11.0.tar.gz
Size 509.1 kB
Tags Source
SHA-256 checksum
How to use checksums
b3d34385ee88a1d83f13ccbc03632ee92b8f6d8b17d24241302727af68f391c5
BLAKE2b-256 checksum
How to use checksums
98100e113d8cf3c1702f5bf3e15761855f97c8458ec805caee8b53964e17ce79
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 20, 2026.

Transparency log

Release files / ebus_panel_sim-0.11.0-py3-none-any.whl

Download URL ebus_panel_sim-0.11.0-py3-none-any.whl
Size 318.0 kB
Tags Python 3
SHA-256 checksum
How to use checksums
36c34bb59ad226e6e6318788734988285b5617dffffb7834b9fe7f3e780da900
BLAKE2b-256 checksum
How to use checksums
8ca4970addcf188c3bbc8df292849e4bac3f538c5c7f49415e913f9324d8279f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 20, 2026.

Transparency log

Security for ebus-panel-sim 0.11.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for ebus_panel_sim-0.11.0.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 20, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page