Skip to main content

embeddedci-mcp

An MCP server that lets an AI agent drive an EmbeddedCI BenchPod — a hardware-in-the-loop tester wired to a real board. Ask Claude (or any MCP client) to flash a build, power-cycle the target, watch its UART, pretend to be the sensor it expects, probe its I2C/CAN traffic or drive and measure analog signals, and the pod does it.

It is a thin layer over the embeddedci SDK: every tool maps to SDK calls, so anything an agent discovers interactively can become a pytest test.

Requirements

  • Python 3.10+ and uv (for uvx), or pip.
  • A BenchPod reachable over the network, the embeddedci.com cloud, or USB. With firmware 3.9.0 and later, connection usb reaches the full API over the pod's USB network adapter (unless Wi-Fi is configured on the pod, which turns USB networking off); status then reports kind usb_net. A serial device path, or usb on older firmware, is the USB console: status, LA voltage and power only, since the STM32 pod's console has no JSON mode. With several pods plugged into one computer, usb errors and lists them by name; pick one with usb:<name> (for example usb:benchpod-baea06).
  • For flash: OpenOCD with the cmsis_dap_tcp backend (newer than 0.12.0 — e.g. brew install --HEAD open-ocd, or the xPack build) on the machine running the server. The firmware file is read from that machine too. Flashing a build uploaded to embeddedci.com (build/repo/ref) over a cloud connection needs neither: embeddedci.com runs OpenOCD.

Set up your client

Claude Code

claude mcp add benchpod \
  -e BENCHPOD_CONNECTION=192.168.1.213 -e BENCHPOD_LA_VOLTAGE=3.3 \
  -- uvx embeddedci-mcp

BENCHPOD_LA_VOLTAGE is the board's I/O voltage, configured once here — use 1.8 for a 1V8 board. Without it the agent is told to call set_la_voltage before touching the LA bank.

Both variables are optional. connect picks the pod, first match wins:

  1. its connection argument;
  2. the server default, --connection;
  3. BENCHPOD_CONNECTION;
  4. the default connection benchpod-cli saved with benchpod set-connection <address|device|usb> (read-only, from ~/.config/benchpod-cli/config.json, or under $XDG_CONFIG_HOME);
  5. mDNS discovery of the one pod on the LAN.

So the CLI, the SDK and the MCP server share one saved connection. With none of the first four, connect looks for a BenchPod on the LAN over mDNS (like discover) and uses it when it finds exactly one. When it finds none or several, the error lists the pods it heard (name and address) and what to pass instead: host[:port], usb, or embeddedci:<device> for a cloud pod (cloud_list_devices lists those). So claude mcp add benchpod -- uvx embeddedci-mcp is enough for a single pod on your network: just ask the agent to connect.

TLS. A network address uses TLS on port 8443 when the pod has it (firmware 3.9.3+) and pins the pod's certificate on first use, in the same known_pods.json as benchpod-cli; older pods stay on plaintext 8080. BENCHPOD_TLS=on|off and BENCHPOD_TLS_CA work as in the SDK. A changed certificate stops connect with both fingerprints: after a deliberate change, the user runs benchpod lan-tls trust. The lan_tls tool shows the certificate and switches HTTPS-only.

Claude Desktop / Cursor

claude_desktop_config.json (Claude Desktop) or .cursor/mcp.json (Cursor):

{
  "mcpServers": {
    "benchpod": {
      "command": "uvx",
      "args": ["embeddedci-mcp"],
      "env": {
        "BENCHPOD_CONNECTION": "192.168.1.213",
        "BENCHPOD_LA_VOLTAGE": "3.3"
      }
    }
  }
}

Codex

The Codex CLI keeps its MCP servers in ~/.codex/config.toml. Add it with the CLI:

codex mcp add benchpod \
  --env BENCHPOD_CONNECTION=192.168.1.213 --env BENCHPOD_LA_VOLTAGE=3.3 \
  -- uvx embeddedci-mcp

…or write the entry yourself (codex mcp list shows what is configured):

# ~/.codex/config.toml
[mcp_servers.benchpod]
command = "uvx"
args = ["embeddedci-mcp"]
env = { BENCHPOD_CONNECTION = "192.168.1.213", BENCHPOD_LA_VOLTAGE = "3.3" }

A pod in the cloud

Use the device name and an API key — the cloud transport is included:

"env": {
  "BENCHPOD_CONNECTION": "embeddedci:my-bench",
  "BENCHPOD_API_KEY": "eci_…",
  "BENCHPOD_LA_VOLTAGE": "3.3"
}

Or skip the API key: after benchpod login, the server reuses that session (~/.config/benchpod-cli/token.json, refreshed and written back when it has expired) for cloud_list_devices, connect("embeddedci:<name>") and, on a LAN or USB connection, the pod's stored wiring profile. BENCHPOD_API_KEY wins when set, and inside GitHub Actions the SDK uses OIDC instead.

cloud_list_devices lists the pods on your account and which are online, without connecting to one; pass a result's connection to connect. The session token behind a cloud connection is renewed before it expires, so a long session keeps working.

A cloud pod is shared, so connect takes an exclusive lease (waiting up to --lease-wait seconds if another run holds it). The lease is released by disconnect, or after --idle-timeout seconds without a tool call — the next call reconnects transparently, so an idle chat never blocks CI on that pod.

Options

Flag Environment Default
--connection BENCHPOD_CONNECTION the CLI's saved connection, else mDNS host[:port], serial device, usb, usb:<name>, discover, saved, or embeddedci:<device>; unset = benchpod set-connection's saved one, else find the one pod on the LAN
--la-voltage BENCHPOD_LA_VOLTAGE — LA I/O voltage (1.8 or 3.3) applied on connect
— BENCHPOD_API_KEY — cloud pods and the waveform library (without it, cloud tools use the benchpod login session)
— BENCHPOD_API_BASE https://www.embeddedci.com another embeddedci server
— BENCHPOD_WIRING — wiring profile file (.json/.toml) that wins over the stored profile
— BENCHPOD_WIRING_SOURCE auto local never asks embeddedci.com for the pod's stored wiring profile
--lease-wait — 30 cloud: seconds to wait for a busy pod
--idle-timeout — 600 cloud: release the lease after this many idle seconds (0 = never)
--timeout — 30 per-command device timeout
--transport — stdio stdio or http
--host / --port — 127.0.0.1 / 8000 HTTP bind address
--auth-token EMBEDDEDCI_MCP_TOKEN — require Authorization: Bearer <token> (mandatory off loopback); prefer the variable or --auth-token-file, since a command-line token shows in ps
--auth-token-file — — read the bearer token from this file's first line
--allowed-host — — Host header(s) to accept on a network bind (DNS-rebinding protection)
--allow-unauthenticated — off serve a network address without a token (isolated networks only)

Serving a bench over HTTP

Run the server on the machine next to the pod, and point clients at it:

export EMBEDDEDCI_MCP_TOKEN=$(openssl rand -hex 32)
embeddedci-mcp --transport http --host 0.0.0.0 --connection 192.168.1.213 --la-voltage 3.3
claude mcp add --transport http benchpod http://bench-host:8000/mcp \
  --header "Authorization: Bearer $EMBEDDEDCI_MCP_TOKEN"

The server drives real hardware, so it refuses a non-loopback bind without a token. It holds one pod connection shared by all HTTP clients, and serialises their tool calls.

Tools

Every tool, grouped as in the server. Parameters in bold are required; the others are optional and show their default when they have one (no default means "from the wiring profile", "keep the current setting" or "not used"). Units are volts, amps, seconds and hertz. LA channel arguments take a number (1-14) or a name from the wiring profile. Each tool's input schema carries the full description, ranges and enums, so an agent sees more than this table.

Connection

Tool Purpose Parameters
connect Open a connection (closing any previous one) and report status, capabilities and where the wiring profile came from. Without a connection or a configured default (--connection, BENCHPOD_CONNECTION, the CLI's saved connection), finds the one pod on the LAN over mDNS. connection, la_voltage, lease_wait=30
disconnect Close UART/CAN sessions and the connection, releasing a cloud lease. none
status Firmware, capabilities, LA voltage, open sessions and warnings (works when not connected). none
set_la_voltage Select the LA I/O voltage to match the DUT (1.8 V needs a rev3 pod). voltage

Cloud (embeddedci.com)

Tool Purpose Parameters
cloud_list_devices The pods on your embeddedci.com organization and whether each is online, without connecting. none

Wiring profile

Tool Purpose Parameters
wiring Which DUT signal is on which LA channel, plus the power rail, UART baud and SWD target. none
set_wiring Replace the wiring profile for this connection, or store it on embeddedci.com. Also sends the profile's pin directions to the pod (la_dir, firmware 3.10.4+; directions in the result says whether it worked). profile, save=false

Power

Tool Purpose Parameters
power_on Switch the target's power rail on (optionally scheduled pod-side). efuse, delay
power_off Switch the target's power rail off. efuse, delay
power_status Both target-power rails, internal 5 V (efuse 1) and external (efuse 2): on/off, tripped, bus voltage and current, and the pod's own draw. none
reset_target Drive the DUT's reset line from the pod's reset pin. action=pulse, pulse=0.1

Power profiles

Tool Purpose Parameters
measure_power Sample supply current and voltage for a window: average, min, peak, energy and charge. duration, efuse, rate_hz=500, points=0
power_profile_start Start sampling the rail in the background while other tools run. efuse, rate_hz=500, max_duration=60
power_profile_stop Stop the running profile and return its statistics (and a trace). points=0

Flash

Tool Purpose Parameters
flash Program the DUT over SWD through the pod's CMSIS-DAP probe: a local file (OpenOCD runs next to the server), or a build uploaded to embeddedci.com (build id or latest, repo, ref; embeddedci.com runs OpenOCD on a cloud connection, LAN/USB downloads it). With target esp32 (or esp32s3, esp32c3, ...) the pod flashes an ESP32-family target over its UART ROM bootloader instead: file is a .bin or an ESP-IDF flasher_args.json, TXD0/RXD0 on rx/tx (default: the profile's uart_rx/uart_tx), IO0 on boot, EN on the pod's reset pin (nreset), a .bin at load_address. swclk, swdio, target, file, nreset, load_address, target_power, verify=true, reset=true, connect_under_reset, extra_configs, extra_args, timeout=300, connect_attempts=5, build, repo, ref, artifact, server_side, rx, tx, boot

SPI flash and SPI devices

Tool Purpose Parameters
spi_flash_info Read the JEDEC ID and size of the SPI NOR flash on the SPI pins. sck, mosi, miso, cs, hz=1000000, mode=0
spi_flash_program Erase, write and verify an image in the SPI NOR flash. file, addr=0, erase=true, verify=true, hold_reset=false, sck, mosi, miso, cs, hz=6000000, mode=0
spi_flash_read Read flash bytes to a file, or up to 4096 bytes as hex. addr, length, file, sck, mosi, miso, cs, hz=6000000, mode=0
spi_transfer One full-duplex SPI transaction with any device on the SPI pins. tx_hex, sck, mosi, miso, cs, hz=1000000, mode=0

mode is 0 to 3; modes 1 and 2 need gateware v55+.

I2C master

The pod as an I2C master on two LA pins (gateware v55+), to read and write registers of a chip on the DUT's board. The bus needs pull-ups: the pod's on LA1-LA6 (set_pull first, LA voltage 3.3), or the board's with pullups="external".

Tool Purpose Parameters
i2c_open Make the pod an I2C master on two LA pins; hz in the result is the SCL rate the pod runs (a real bus is somewhat slower: the rise time adds to each period). sda, scl, hz=100000, pullups=pod
i2c_transfer Write, read, or write then read (repeated START); neither is a probe. A NACK returns ack: false and nack_at. addr, write_hex, read=0
i2c_scan Which addresses answer. start=8, end=119
i2c_close Release the I2C master's pins. none

UART

Tool Purpose Parameters
capture_uart Record the DUT's UART for a window, or until a regex matches. duration, rx, tx, baud, until_regex
power_cycle_and_capture Power-cycle the target and capture UART across the boot. rx, tx, efuse, delay=1, duration=4, baud, until_regex, off_settle=0.3
uart_open Start buffering the DUT's UART in the background. rx, tx, baud
uart_write Send text to the DUT through the open UART session. text, line_ending=lf
uart_read Return output received since the last read, optionally waiting for a match. until_regex, timeout=2
uart_close Stop the background UART session. none

Emulated sensors

The pod plays I2C, SPI, UART and analog sensors from a definition (YAML or JSON, the format of the public sensor library): a library entry such as bme280, sht4x, mpu6050 or gps_nmea, or one the agent writes from a datasheet. Up to 4 I2C sensors, 1 SPI and 1 UART sensor run at once, each a named instance. Needs pod firmware with the sensors capability; older firmware fails with "this pod's firmware is too old for sensor emulation; update the firmware". The library tools need no pod. The server uses the library version the SDK pins (0.1.0, bundled) unless BENCHPOD_SENSOR_LIBRARY, the CLI's sensor_library setting or a version argument says otherwise.

Tool Purpose Parameters
sensor_library The library's sensors and stimuli (name, kind, label) and the version in use; version switches it for the other sensor tools. version (latest, 0.2.0, default)
sensor_show One library entry: its YAML (a starting point for your own part) and the params sensor_set takes. name, version
sensor_format The definition and stimulus format reference (Markdown), to write a definition from a datasheet. version
sensor_validate Check a definition: the header here, then a dry-run compile on the pod (header only when no pod is connected). definition (a library name, YAML/JSON text, a JSON object or a path)
sensor_start Upload a definition and start it on pins (set the LA voltage and, for I2C, the pull-ups first); returns the params and whether the emulation FPGA image was loaded. definition, instance (1 to 16 characters; default: its name), pins (sda/scl/drdy, sclk/mosi/miso/cs (no data-ready pin on SPI), tx/rx, output; channels or wiring names, I2C and SPI default to the profile), address, baud, values
sensor_set Change what a running sensor reports; out-of-range values are refused with the range. instance, values
sensor_stimulus_load Upload values over time (and timed faults) for the running sensors. stimulus (YAML/JSON text, a JSON object or a path)
sensor_stimulus_start Play the loaded stimulus. at_s
sensor_stimulus_stop Stop it; values stay where it left them. none
sensor_fault Make a sensor misbehave now: stuck, offset, gain, no_response, corrupt, bus_stuck, garbage, drop, baud_error, open, short. instance, type, duration_s (default: until cleared), param, value, at, mask, rate_hz
sensor_fault_clear End a sensor's faults. instance
sensor_stop Stop one sensor, or all; the pod releases the pins and forgets the definition; returns the names it stopped. The emulation image stays loaded. instance (default: all)
sensor_status Running sensors (slot, pins, values, faults with left_s, bus counters such as writes; transfers is always null), the stimulus and the FPGA image, every page in one reply. none
sensor_regs The bytes an I2C/SPI sensor answers now. instance, start=0 (0..255), length (default: to the end of the 256-byte image)
sensor_capture Wait for the DUT's next transaction on an I2C sensor's bus (up to 2 s; firmware with sensor_la_trigger, older firmware captures at once), capture it and decode it into a transaction trace (I2C only; capture_la for SPI and UART sensors). instance, samples=4096 (1..4096 packed bytes), address, register

Pull resistors

Tool Purpose Parameters
set_pull Engage or release the bias resistors: LA1-LA6 pull up, LA7/LA8 pull down. las, enabled
pull_status State, direction and value of the bias resistor on LA1-LA8. none
lan_tls The pod's LAN API over TLS (firmware 3.9.3+): port 8443, the HTTPS-only setting and the certificate's sha256 (what clients pin). Turning HTTPS-only off and regenerating need a TLS, USB or cloud connection. https_only, regenerate
usb_network Read the pod's USB network setting (firmware 3.9.0+), or turn the adapter off over the USB link. Only the device changes it; turning it back on is benchpod usb-network on on the USB console. set=off

GPIO on the LA pins

Tool Purpose Parameters
la_pins What owns each of the 14 LA channels, with GPIO mode, level and bias resistor. none
gpio_mode Claim LA channels as GPIO (input, output or open drain). la, mode=output, level
gpio_write Set the level of GPIO output and open-drain channels. la, level
gpio_read The live level of LA channels (all 14 when la is omitted). la
gpio_wait Wait until an LA channel reads a level (reached: false on timeout). la, level=1, timeout=5
gpio_pulse FPGA-timed pulses on an LA channel: width 4 us to 65.535 ms, count up to 65535. la, width, count=1
gpio_release Return channels to high-Z, watched by captures. la
la_dir Which way each pin's DUT signal goes (dut_input, dut_output, bidir, unknown); on a DUT output the pod refuses push-pull drivers. connect and set_wiring already send the wiring profile's; from_wiring sends them again; no arguments lists every pin. la, dir, from_wiring=false

Analog

Tool Purpose Parameters
analog_path Set every analog mux and relay for a named path in one step; range sets the ADC input range too. path, range
dac_output Route a DAC output and drive a calibrated DC voltage on it. path, volts
current_out Hold a current on the 4-20 mA output (J9), in amps, or read its range. current
adc_read One calibrated reading: front SMA, DAC loopbacks or the 4-20 mA input (J8); reports the ADC range, its full scale and overrange. source=ext, range
adc_range Read or switch the ADC input range: normal ±32.8 V or low ±5.46 V at 6x the resolution (analog module v3r4+, firmware 3.9.5+; 1x leads, the low range's input is 1.82 MΩ), or self-test it through the cal1 loopback. range, test=false
calibration The stored calibration: the ADC offset (measured on the 4-20 mA input) and the fit it uses, plus the DMM lines and gains (firmware 3.9.4+). none
calibrate Measure and store the ADC offset on the 4-20 mA input (J8 open), or clear the calibration (all of it, or one part). source=current_in, clear=false, clear_part
calibrate_dac Store this pod's line for a DAC output from two DMM readings of set points driven with dac_output (firmware 3.9.4+). path, code1, volts1, code2, volts2
calibrate_adc_gain Measure an ADC source's gain through a loopback against a DMM-calibrated output (firmware 3.9.4+); range=low the ADC low range's gain through cal1 (firmware 3.9.5+). source, range=normal

Capture and decode

Tool Purpose Parameters
capture_adc Capture the ADC: calibrated statistics, dominant frequency and a min/max envelope; clipped_samples counts samples past the range's full scale. oversample converts at 400 kS/s and averages down to sample_rate_hz for lower noise, about 5 s at most. samples=4096, sample_rate_hz, source, points=200, trigger_la, trigger_edge=rising, trigger_timeout=10, range, oversample
capture_la Capture all 14 LA channels: levels, edge count, first edge and frequency per channel. Up to 48 MS/s on gateware v50+. send (gateware v55+) runs one transaction right after the capture arms: {"bus":"i2c","addr":118,"write_hex":"d0","read":1} (the i2c_open session, else one from the wiring), {"bus":"spi","tx_hex":"9f00"} (SPI pins from the wiring) or {"bus":"gpio","la":6,"level":0} (a GPIO output); without trigger_la it triggers on SDA or CS falling or the pin's edge, and the result's send has the reply. samples=4096, sample_rate_hz, stop_dac_after, trigger_la, trigger_edge=rising, trigger_timeout=10, trigger_pre_samples=0, send
capture_correlated ADC and LA from one hardware trigger, on one timebase. adc_samples=4096, adc_sample_rate_hz, la_samples=4096, la_sample_rate_hz, stop_dac_after, points=200, trigger_la, trigger_edge=rising, trigger_timeout=10, source
decode_la Decode I2C, UART or SPI from the last LA capture (or a new one). protocol, sda, scl, rx, baud, sclk, mosi, miso, cs, mode=0, capture=last, samples=16384, sample_rate_hz=1000000, max_items=200
la_timing Edge timestamps, pulse widths, frequency, duty cycle and channel-to-channel delay from the last capture. la, edge=rising, to_la, to_edge=rising, after=0, max_edges=100

DAC

Tool Purpose Parameters
generate Drive a sine, square or sawtooth on a DAC output (volts, or amps on current_out). waveform, freq_hz, amplitude, offset, dac_path=3v3, duration, sample_rate_hz, on_capture=false, route=true
dac_stop Stop any DAC output: generator, replay or control loop. none
replay Loop your own samples, or the last ADC capture, out of the DAC. volts, from_last_capture=false, dac_path=3v3, mapping=faithful, sample_rate_hz, fault, on_capture=false, route=true, switch_image=true
list_waveforms The organization's cloud waveform library. none
replay_waveform Loop a cloud-library waveform out of the DAC. waveform_id, dac_path, mapping=faithful, sample_rate_hz, window_start=0, window_len=0, target_samples=0, fault, on_capture=false, switch_image=true
save_capture_as_recording Save the last ADC capture to the cloud waveform library. name, full_scale_v

Control loop

Tool Purpose Parameters
control_loop Run a tabulated transfer function in the FPGA (for example a solar panel I-V curve). curve, voc_code, sharpness=4, points=256, k=8192, vmin=0, vmax=65535, tick_div=64, source, input_code=0, step=0, input_map, switch_image=true
loop_input Re-target the running loop's input without re-arming. input_code, source, step
loop_probe The running loop's live operating point. none
fpga_image Switch the FPGA to the loop, deep_replay or emulation gateware image (~2-3 s); refused while I2C, SPI or UART sensors run on the emulation image. image

CAN

Tool Purpose Parameters
can_open Bring up the pod's CAN interface (normal, loopback or listen-only): classic CAN, or CAN FD with data_bitrate (firmware 3.10.2+, up to 8 Mbit/s, 64-byte frames). bitrate=500000, mode=normal, term=false, data_bitrate
can_write Queue one CAN frame: up to 8 bytes, or 64 on a CAN FD bus (FD with bit-rate switching unless fd=false / brs=false). can_id, data, ext=false, rtr=false, fd, brs
can_read Read received frames, or wait for one id. timeout=0, can_id, max_frames=32
can_respond Answer a CAN id from the pod firmware (ECU simulation), or clear all rules. match_id, reply_id, reply_data, match_ext=false, reply_ext=false, reply_fd, reply_brs, clear=false
can_status Link state: mode, bitrate, error counters, bus-off. none
can_close Clear responder rules, stop CAN and switch the 120 Ω termination off. none

Other

Tool Purpose Parameters
la_step Step pulses for step/dir motor drivers: delay is half the step period (4 us to 65.535 ms), steps up to 65535. la, steps, delay, dir_la, direction=0
command Raw firmware JSON command, for anything no tool covers. request

AI Vision board

For a bench with an AI Vision board (ai-vision-2): a camera on the DUT's screen that reads text, finds buttons and presses them through its actuator. Its connection is separate from the pod's, so one session drives both. Without vision_connect, the first vision_* call connects to AIVISION_CONNECTION (token in AIVISION_TOKEN). Boxes and taps are in screen pixels once the screen is calibrated.

A board paired with embeddedci.com is reached from anywhere as embeddedci:<name>: vision_cloud_boards lists the organization's boards, and vision_connect takes the connection it returns. Over embeddedci.com the server's sign-in applies (BENCHPOD_API_KEY, an API key with the "Control AI Vision" scope, else the benchpod login session) and lease_as takes the server's device lease, the one the web app and other runs see.

Tool Purpose Parameters
vision_cloud_boards The AI Vision boards on embeddedci.com, online or not, with the connection to pass to vision_connect. none
vision_connect Open the AI Vision connection (a LAN address, discover or embeddedci:<name>; closing a previous one) and report its status. connection, token, lease_as
vision_disconnect Close the connection and release its lease. none
vision_status Version, calibration, camera lock, actuators, lease, capabilities, with warnings. none
vision_look The screen as an image (an image content block), or what the camera sees; a region zooms in at full sensor resolution. space=screen, overlay, region
vision_ocr All text on the screen or in a region, in reading order, with boxes. region, zoom
vision_find Elements matching text, a kind (button, icon, text) or a template, best first. text, label, template, match, region
vision_wait_for Wait until text appears (or with gone, disappears); met: false on timeout. text, timeout_s=10, gone=false, match, region
vision_compare Similarity of the screen to a stored reference screen. reference, mask
vision_screen_health Black, dim, frozen, flickering or stuck pixels over a window. window_ms=1000, expect_motion=false
vision_calibrate Map camera pixels to screen pixels: four corners and the screen size, or method auto/markers. corners, screen_size, method
vision_add_reference Store the current screen (or a region, as a template) as a reference. name, kind=screen, region, overwrite=false
vision_press Find an element, tap its center, optionally wait for verify_text. Fails with the visible text when it is not there. text, verify_text, verify_timeout_s=5, match, actuator
vision_tap Tap a point in screen pixels (hold_ms for a long press). x, y, hold_ms=0, actuator

Resources: benchpod://wiring (the connected bench's own wiring profile, then LA channels, bias resistors and analog paths) and benchpod://help (the server instructions). For drawing captures in an app (the BenchPod desktop app's capture view), three more give the last capture in full:

Resource JSON
benchpod://capture/la The last capture_la / capture_correlated as run-length edges, [sample index, 14-bit word] from sample 0, plus sample_rate_hz, count, pre_samples, seq, correlated.
benchpod://capture/adc The last capture_adc / capture_correlated: samples in volts (or mA for current_in), unit, sample_rate_hz, source, seq, correlated.
benchpod://capture/decode The last decode_la: protocol, channels, and I2C transactions with timed segments, or UART / SPI frames with start_us / end_us; seq is the capture it decoded.

Each is {"seq": 0} before the first capture. seq numbers the captures, and correlated says the LA and ADC captures share one timebase. They can be megabytes: an agent should read the capture tools' summaries, la_timing and decode_la instead.

How it behaves

  • Instructions. The server sends usage instructions at initialisation — session start, typical flows, units, error contract — so the agent knows to connect and set_la_voltage before anything else.

  • Typed, structured results. Every tool has an input schema with enums and ranges (paths, sources, LA channels 1-14, internal 5 V (efuse 1) or external (efuse 2), …) and an output schema; results come back as structured content. Units are volts, seconds and hertz.

  • Errors. A tool that cannot do what was asked fails with an MCP tool error whose message names the cause, e.g. FirmwareError: la voltage not set or NotConnectedError: …. A completed operation with a negative outcome is a normal result: flash returns ok: false with its logs, a UART capture matched: false.

  • Refusals. When the pod or the server refuses a command, the error names the kind and ends with a one-line hint on what to do: PodLockedError (the pod's LAN policy keeps the command for the cloud or USB), PodLeasedError (a cloud job holds the pod; the message names who and for how long), PodBusyError (a capture or upload is running), PermissionDeniedError (the credential lacks the right, for example an API key without the benchpod:admin scope) and TransportTimeout (the pod did not answer). A dropped link is a ConnectionClosedError. UnsupportedFeatureError means the pod cannot do it at all: its firmware or gateware lacks the feature, or it is the digital-only board without the analog front end; the hint says which. status also warns when a cloud job holds the pod or the LAN policy is locked. Refusals whose fix the firmware spells as a raw protocol command name the tool instead: FirmwareError: uart_proxy_start: la voltage not set; call set_la_voltage first with the DUT's I/O voltage (1.8 or 3.3) and PinConflictError: uart_proxy_start: pin conflict: LA4 is in use by gpio; release it with gpio_release(la=[4]). The other pin owners point to uart_close and sensor_stop; a pull conflict to set_pull(las=[7], enabled=false).

  • Capabilities. connect and status report what the pod can do as flags, so an agent can check before it calls a tool: for example la_pins, capture_trigger, power_profile, nrst_pin, can, calibrate, cal_dmm, current_out, pod_current, sensors and analog (false on the digital-only board), plus the pod's policy and cloud settings (dac_limits, flash_kb, ota_sig, sig_policy, lan_policy, tunnel_max_tier, lease_state, cloud_ca, cloud_proxy).

  • Wiring profile. wiring is the bench's map of DUT signal → LA channel, plus the target-power rail, the UART baud and the SWD target. Omitted channel / baud / rail / SWD arguments come from it, and channel arguments also accept its names (trigger_la: "READY", rx: "uart_rx"), so an agent that read wiring once can call flash(), uart_open() or power_on() with no pin numbers at all. set_wiring replaces it for the connection, or stores it on embeddedci.com with save: true.

    It is the same profile the web UI's Wiring tab edits. The SDK resolves it, first match wins: BENCHPOD_WIRING (a file); the profile stored on embeddedci.com for this pod (a cloud pod by name; a LAN or USB pod by the device it reports it is registered as, when BENCHPOD_API_KEY or the benchpod login session is available and that device is on the same account); the defaults. wiring and connect/status (wiring_source) report where it came from: server, file, dict (from set_wiring) or defaults. When the lookup fails (not signed in, pod not registered, server unreachable, another account) the defaults apply and nothing fails; over the LAN or USB it gives up after about 3 seconds. The STM32 pod's USB text console cannot report its registration, so over USB the defaults apply. BENCHPOD_WIRING_SOURCE=local skips the lookup.

  • Pin directions on by default. Every wired role and signal has a DUT direction, shown per channel in wiring (dut_dir): uart_rx and spi_miso are DUT outputs; uart_tx, the other SPI pins and SWCLK DUT inputs; I2C and SWDIO bidirectional; a signal the pod watches (input) a DUT output, one it drives (output) a DUT input. The profile's dut_dirs overrides any of them. On firmware 3.10.4+ connect and set_wiring send them to the pod (la_dir), which then refuses a push-pull driver on a DUT output pin, so the pod never drives against the DUT. Older firmware is skipped quietly. wiring and set_wiring report directions, and status warns when a driven pin kept them from going out.

  • Agent-sized captures. capture_adc returns calibrated statistics, the dominant frequency and a min/max envelope; capture_la returns per-channel levels, edges and frequencies. The last captures stay in the session, so decode_la, replay(from_last_capture=true) and save_capture_as_recording don't capture again.

  • Triggered captures. capture_adc, capture_la and capture_correlated take trigger_la (+ trigger_edge rising/falling/high/low and trigger_timeout) so sampling starts on an event — t = 0 is the trigger — and the summary echoes it as trigger: "LA9 rising". A condition that never happens fails with TriggerTimeout: ….

  • Pins and GPIO. Each LA channel has one owner at a time: none, GPIO, a UART proxy, SWD, the an emulated sensor (owner sensor:<instance>) or a step train. la_pins shows the table, gpio_mode / gpio_write / gpio_read / gpio_wait / gpio_pulse drive and watch channels, gpio_release frees them. A second claim fails with PinConflictError: pin conflict: LA5 is in use by uart_rx; … naming the owner and how to free it — so the agent releases GPIO before opening a UART session on that channel. Captures observe all 14 channels whatever owns them.

  • Power profiles. measure_power(duration) reports average, minimum and peak current, voltage, energy and charge. Every sample is timestamped and the integrals run over those timestamps, so energy is integrated rather than estimated. rate_hz (100-500, default 500) tracks the request to ~200 Hz and then flattens near 365 Hz — the result reports the rate actually delivered in rate_hz and the sensor's configured rate in adc_rate_hz. Optional downsampled trace (points). power_profile_start / power_profile_stop bracket other tool calls; the running profile lives on the session (status reports it) and is dropped on disconnect.

  • Sessions. uart_open buffers the DUT's console in the background (open it before power_on, then uart_read / uart_write); can_open keeps a CAN bus open across calls.

  • Gateware images. The pod's FPGA runs either the loop image (control_loop) or the deep_replay image (replays longer than 2048 samples). control_loop, replay and replay_waveform switch automatically (~3 s) and report it as switched_image; switch_image: false fails instead. A switch resets the FPGA — a running DAC output, UART session or sensor emulation stops — and the server instructions tell the agent to start those after it. fpga_image switches explicitly. I2C, SPI and UART sensors run on a third, emulation image that sensor_start loads by itself; the pod never switches back, so control_loop and the deep replays switch back once no such sensor runs (and name sensor_stop while one does).

  • Non-blocking. Tools run on worker threads under one device lock: a 5-minute flash doesn't freeze the server, sends progress notifications, and concurrent calls can't interleave commands.

  • Annotations. Read-only tools (status, power_status, adc_read, …) are marked so clients can auto-approve them; tools that power, flash or drive voltages are marked destructive.

Example

Connect to the bench, flash build/app.elf to the STM32F4 (SWCLK on LA11, SWDIO on LA12, reset wired), then power-cycle it and tell me whether it reaches APP_OK on the UART (DUT TX on LA5, RX on LA4).

connect()                                   # BENCHPOD_CONNECTION + BENCHPOD_LA_VOLTAGE
flash(swclk=11, swdio=12, nreset=true, target="target/stm32f4x.cfg", file="build/app.elf", target_power=1)
power_cycle_and_capture(rx=5, tx=4, delay=1.0, duration=5.0, until_regex="APP_OK")

With a wiring profile stored for the bench, the same run needs no pin numbers:

connect()
wiring()                                    # SWCLK on LA11, DUT TX on LA5, rail internal 5 V (efuse 1), …
flash(file="build/app.elf")
power_cycle_and_capture(delay=1.0, duration=5.0, until_regex="APP_OK")
measure_power(duration=2.0, points=100)     # what the firmware draws once it is up

Stability

2.x freezes the tool names, input schemas and annotations (tests/tools_surface.json; CI fails on any unreviewed change): tools and optional parameters may be added, nothing is renamed or removed within a major version. See CHANGELOG.md for migrating from 0.1.

Publishing to the MCP Registry

server.json describes this package for the MCP Registry. The embeddedci-mcp-v* release workflow publishes it after the PyPI upload (which is what makes uvx embeddedci-mcp work), logged in with GitHub OIDC. Bump both version fields in server.json together with pyproject.toml: the release fails when they differ, and so does CI.

To publish by hand instead:

mcp-publisher login github
mcp-publisher publish

The registry verifies PyPI ownership through the mcp-name comment at the top of this README.

Development

pip install -e "../embeddedci[dev]" -e ".[dev]"
pytest

Metadata

Release files for embeddedci-mcp 2.13.19

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for embeddedci-mcp 2.13.19
File Size Uploaded Provenance Actions
embeddedci_mcp-2.13.19.tar.gz 170.0 kB With provenance Details for embeddedci_mcp-2.13.19.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for embeddedci-mcp 2.13.19
File Interpreter ABI Platform Actions
embeddedci_mcp-2.13.19-py3-none-any.whl Python 3 none any Details for embeddedci_mcp-2.13.19-py3-none-any.whl

Total release size: 263.8 kB

Release files / embeddedci_mcp-2.13.19.tar.gz

Download URL embeddedci_mcp-2.13.19.tar.gz
Size 170.0 kB
Tags Source
SHA-256 checksum
How to use checksums
68bdf95f62fea9c9a54daab6313f3eda3ea7b77af516cabeaef4858701cafbb3
BLAKE2b-256 checksum
How to use checksums
30119b1c192b3d82f5d98ac1ba5d4ed16e9db4fb6e158c43642290625dd61e71
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 16, 2026.

Transparency log

Release files / embeddedci_mcp-2.13.19-py3-none-any.whl

Download URL embeddedci_mcp-2.13.19-py3-none-any.whl
Size 93.7 kB
Tags Python 3
SHA-256 checksum
How to use checksums
24eb40be0d2924162c2865da265b7b800241de90696ce9e5bf5ace38843c6960
BLAKE2b-256 checksum
How to use checksums
afeb42614fa88d3ca1628e099b5d1b6007fe4573cea8d473e0e3bc75e812d6f0
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 16, 2026.

Transparency log

Security for embeddedci-mcp 2.13.19

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for embeddedci_mcp-2.13.19.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 16, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Release history Release notifications | RSS feed

This release

2.13.19 This release

2 release files Full provenance

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page