Skip to main content

franklinwh-direct-connect-api

This library is a proof-of-concept demonstration of how to talk to a FranklinWH aGate gateway over the (undocumented, unofficial) FranklinWH Direct Connect local API — the JSON cmdType frames exchanged over TCP/9000. It is the lower-level device↔broker channel that the cloud sendMqtt REST relay (see franklinwh-cloud) is layered on top of.

On the names. Direct Connect is FranklinWH's own term for the gateway's local protocol. This project implements that protocol; it is the library and CLI, not an application — the Direct Connect Bridge is the application built on top of it, and is where a REST API, MQTT, Home Assistant entities and a web UI live. Adopting FranklinWH's term implies no affiliation with, endorsement by, or support from FranklinWH.

The distribution on PyPI is franklinwh-direct-connect-api, the import package is franklinwh_direct_connect_api, and the CLI command is franklinwh-direct-connect. The pre-0.4.0 spellings still work, because removing them would break existing code: importing franklinwh_local returns the same module objects (so isinstance and subclassing hold across both spellings), the franklinwh-local command is the same entry point, and LocalClient/LocalTransport remain aliases of DirectConnectClient/ DirectConnectTransport. Importing the old package emits a DeprecationWarning, and the aliases are scheduled for removal in 0.6.0 — the date was previously 0.5.0, which shipped with them still in place.

It is not intended for production use, and there is no guarantee it is compatible with your FranklinWH gateway(s), aPower(s) or connectivity — now or in the future. FranklinWH may change, block or deprecate this interface at any time. It has been tested on a local area network against one aGate X with one aPower, most recently on firmware IBG_VER V12R02B60D00_260924 / protocolVer V1.12.02 (read 2026-10-31). One site on one firmware is a hypothesis, not a compatibility matrix: multi-aPower behaviour in particular is unobserved, and anything this documentation marks UNCONFIRMED has not been proven on any hardware.

You do not need a gateway to try it. Run the built-in emulator and point the whole CLI and library at it — a deterministic synthetic aGate with N aPowers, live telemetry, energy history, smart circuits and writes that persist, so you can see the thing work before you connect real hardware:

franklinwh-direct-connect emulate                       # a fake aGate (port 19000)
franklinwh-direct-connect --host 127.0.0.1 --port 19000 power_flow  # ... talk to it

TCP 9000 is a reserved port and not available to this emulator. It refuses to start on 9000 and defaults to 19000. 9000 belongs to a real aGate and to the FranklinWH Gateway Emulator — the official emulator, which is deliberately transparent, so something answering on 9000 is meant to be indistinguishable from a gateway. This library's mock must stay distinguishable from one: a mock left on 9000 once showed up in a LAN scan as 9000/sendMqtt CONFIRMED, which makes every discovery result untrustworthy.

proxy is the exception and still listens on 0.0.0.0:9000: it relays every byte to a real aGate and never answers on its own behalf, so a client reaching it is talking to the gateway. Sitting on :9000 between the app and the device is the point of that tool.

The emulator is a development aid. It serves what it was told to serve, so it is not evidence of how real hardware behaves.

Status: alpha. The protocol was reverse-engineered from packet captures. Frame parsing/encoding and the offline tooling are well tested; live transport against real hardware should be validated on your own LAN.

This is still work in progress - as some functions have not been fully tested and/or exposed yet.

For example (there may be others):

  • set operating mode specific reserved state of change
  • battery dispatch to force charge and discharge
  • set battery or grid inverter power (in watts) for battery dispatch operations
  • determining battery capabilities for the AC inverter (in watts) and battery capacity (in watt hours)

Why this exists

A FranklinWH aGate can be reached three different ways:

  • The FranklinWH Cloud API — what the official mobile app and the FleetView installer portal use. Capable, but it routes through FranklinWH's servers and needs an account and an internet connection.
  • Modbus TCP (SunSpec) — a standards-based local interface. Good for basic power/energy reads and a few setpoints, but only a narrow slice of what the device actually knows.
  • The aGate's own local broker protocol — the proprietary sendMqtt cmdType channel on TCP/9000 that the app itself speaks under the hood. The official FranklinWH app calls this interface "Direct Connect." This is what this library implements.

The project exists to demonstrate that third path: a fully local, no-cloud, no-account way to query, control, and administer an aGate directly on your LAN — no FranklinWH servers, no Modbus gateway required. Because it's the device's native channel, it surfaces the deep structural telemetry the cloud strips out to keep the app fast (per-cell battery voltages, relay/contactor states, full physics arrays), plus configuration and control (operating mode, off-grid, reboot) — things neither a plain Modbus read nor the cloud expose together in one place.

⚖️ Disclaimer

UNOFFICIAL SOFTWARE — NOT AFFILIATED WITH OR ENDORSED BY FRANKLINWH.

This library speaks FranklinWH's undocumented Direct Connect (local) protocol on TCP/9000 — technically the same private channel the official FranklinWH mobile app uses, intended for that app and not for third-party use. It may change, break, or become unavailable without notice. It is provided AS-IS, without warranty of any kind, express or implied — use entirely at your own risk. The authors accept no liability for service interruptions, data loss, equipment damage, or any other consequences of using this software.

On the name "Direct Connect": the official FranklinWH app uses this label for the local interface; this project adopts the term purely to identify the same channel. It implies no affiliation with, endorsement by, or support from FranklinWH — this is unofficial, reverse-engineered software.

Do NOT contact FranklinWH support about this software. Raise issues, defects, or feature requests on GitHub instead: https://github.com/david2069/franklinwh-direct-connect-api/issues

Compliance & anti-circumvention

You agree to keep your gateway and battery settings, controls, and operation compliant with the configuration set through the official FranklinWH Mobile App and the installer/support FleetView portal.

FranklinWH-managed settings may exist to, among other things: protect the safety and longevity of the battery and gateway; apply automatic software updates and restrict your ability to view or change battery, grid-import, or grid-export controls; enforce your local grid profile and any import/export limits or prohibitions; and enforce restrictions tied to contractual incentives, subsidies, or VPP/grid programmes.

If you use this software to bypass or override any such control, restriction, or compliance measure — deliberately or inadvertently — you do so entirely at your own risk. This is neither condoned nor encouraged by the authors or any other party.

This software is provided for informational and educational purposes, AS-IS, with no warranty of fitness for any purpose. Any use — personal or commercial — is permitted under the MIT License and is entirely at your own risk.

As the MIT License requires, the copyright notice and this notice (including the Additional Terms) should be included in copies or substantial portions of the software — in forks, derivatives, and AI-assisted works alike, so the unofficial-app and compliance context travels with the code. See LICENSE (Additional Terms) for the authoritative text.

Docs: https://david2069.github.io/franklinwh-direct-connect-api/ — Usage (full how-to) · Protocol & catalog (wire format + command catalog) · API reference. The same pages as markdown: docs/.

Setup

Requires Python 3.10+. No runtime dependencies (standard library only).

python3 -m venv .venv          # 1. create a virtualenv
source .venv/bin/activate      # 2. activate it  (Windows: .venv\Scripts\activate)
pip install franklinwh-direct-connect-api

franklinwh-direct-connect --version     # 3. verify
# franklinwh-direct-connect 0.4.0

To work on it instead, install the checkout editable — add [test] for the pytest suite:

git clone https://github.com/david2069/franklinwh-direct-connect-api
cd franklinwh-direct-connect-api
python3 -m venv .venv && source .venv/bin/activate
pip install -e ".[test]"
pytest -m "not live"           # offline suite; "live" tests need a real aGate

How to run it

franklinwh-direct-connect is a console script that pip install puts on your PATH — it is not a .py file in this repo, so these do not work:

python franklinwh-direct-connect ...        # can't open file '.../franklinwh-direct-connect'
python franklinwh_direct_connect_api.py ...     # no such file

Run it one of these three ways:

franklinwh-direct-connect catalog                    # venv activated (recommended)
.venv/bin/franklinwh-direct-connect catalog          # venv not activated — call it by path
python -m franklinwh_direct_connect_api catalog          # module form; works anywhere the package imports

One name throughout, as of 0.4.0: distribution franklinwh-direct-connect-api, import package franklinwh_direct_connect_api, CLI franklinwh-direct-connect. Direct Connect is FranklinWH's own term for this protocol.

Migrating from 0.3.x and earlier

The import package was franklinwh_local and the CLI was franklinwh-local. Both still work and emit a DeprecationWarning; they are scheduled for removal in 0.6.0.

from franklinwh_local import LocalClient                         # 0.3.x — deprecated
from franklinwh_direct_connect_api import DirectConnectClient     # 0.4.0 onward

The alias re-exports the same objects, so isinstance, subclassing and is comparisons hold across both spellings — you can migrate file by file. LocalClient and LocalTransport also remain as aliases of DirectConnectClient / DirectConnectTransport. To find every remaining use, run with PYTHONWARNINGS=error::DeprecationWarning.

For a ready-made application built on this library — REST API, MQTT / Home Assistant entities and a web UI — see the FranklinWH Direct Connect Bridge.

Everything below assumes the venv is activated. Offline commands (catalog, decode, analyze, emulate) need no hardware — start with franklinwh-direct-connect catalog to confirm your install works.

Troubleshooting the install

Symptom Cause / fix
can't open file '.../franklinwh-direct-connect' You ran python franklinwh-direct-connect. Drop the python — it's a command, not a script.
command not found: franklinwh-direct-connect The venv isn't activated (source .venv/bin/activate), or pip install -e . hasn't been run in it.
No module named franklinwh_direct_connect_api You're on a different interpreter than the one you installed into. Check with which python and pip -V — both should point inside .venv.
DeprecationWarning: 'franklinwh_local' was renamed Expected whenever you import the old name (it still works). See Migrating; it stops working at 0.5.0.
error: externally-managed-environment You ran pip install outside a venv on a Homebrew/system Python. Create and activate the venv first.

Quick start

Decode a capture (offline, no hardware):

from franklinwh_direct_connect_api import iter_pcap_frames

for frame in iter_pcap_frames("capture.pcap"):
    print(frame, frame.data_area)

Build and parse a single frame:

from franklinwh_direct_connect_api import encode_frame, decode_frame

wire  = encode_frame(1301, "FAKEGATE90FJ09J6H4F2", {"opt": 0})  # power-flow poll
frame = decode_frame(wire)
assert frame.verify()          # len + crc check

Talk to a live gateway:

from franklinwh_direct_connect_api import DirectConnectClient

with DirectConnectClient("10.100.1.1") as c:   # the hotspot gateway IP
    c.login()                  # 1101 -> 1102 (firmware manifest)
    print(c.power_flow()["soc"])
    print(c.smart_circuits())

    bms = c.battery_cells(1)   # per-cell telemetry, the deep read
    print(bms["batVolt"])      # [3326, 3326, ...] mV per cell
    print(bms["batTemp"])      # [18.8, 18.9, ...] degC per cell
    print(bms["batSoh"])       # 94.9

Battery Management

franklinwh-direct-connect -i 192.0.2.110 battery            # per-cell view
franklinwh-direct-connect -i 192.0.2.110 battery --watch 2 --for 10m

Per-cell voltages and temperatures, pack SoC/SoH, bus rails and states — one session, local only. --watch/--for/--count monitor continuously; Ctrl-C stops.

Per-device reads

Four reads are addressed to a specific device rather than the gateway, and need an id from device_check / battery_modules (devMap[].id):

franklinwh-direct-connect -i 192.0.2.110 battery_cells --id 1      # per-cell V + temps, SoC/SoH
franklinwh-direct-connect -i 192.0.2.110 power_electronics --id 1  # bus/grid/inverter V and A
franklinwh-direct-connect -i 192.0.2.110 device_firmware --id 1    # PE/BMS serials + versions
franklinwh-direct-connect -i 192.0.2.110 device_states --id 1      # DSP/main/PE/BMS states

Called without id they return the same keys with empty or zero values (result=1 reason=-1) — easy to misread as "this command returns nothing".

Connecting (Direct Connection)

The aGate exposes TCP/9000 on its own WiFi hotspot — the same "Direct Connect" path the FranklinWH mobile app uses. To talk to it:

  1. On the gateway/app, start Direct Connect → Connect via aGate hotspot.

  2. Join the WiFi network AP_<serial-suffix> (e.g. AP_F24170091).

  3. The gateway is the hotspot gateway IP (typically 10.100.1.1). Point DirectConnectClient / the CLI at it, or let the scanner find it:

    franklinwh-direct-connect scan gateway        # auto-targets the hotspot gateway
    franklinwh-direct-connect --host 10.100.1.1 power_flow
    

(The app also offers a Bluetooth Direct Connect path; only the WiFi/TCP path is implemented here.)

Discover devices on the LAN

franklinwh-direct-connect scan 10.100.1.0/24    # scan a subnet
franklinwh-direct-connect scan gateway          # just the hotspot gateway
franklinwh-direct-connect scan 10.0.0.0/24 --json

Detects open TCP 9000 (sendMqtt) and TCP 502 (Modbus), and by default confirms a 9000 listener by performing the login handshake.

Test without hardware (emulator)

franklinwh-direct-connect emulate               # fake aGate replaying captured data
# then, in another shell:
franklinwh-direct-connect --host 127.0.0.1 power_flow

CLI

franklinwh-direct-connect catalog                       # list known cmdType codes (grouped)
franklinwh-direct-connect catalog --grep bms            # filter by name/description/cloud call
franklinwh-direct-connect catalog --json                # ... as JSON, with cloud equivalents
franklinwh-direct-connect decode capture.pcap           # decode a pcap
franklinwh-direct-connect decode capture.pcap --json    # ... as JSON

franklinwh-direct-connect --host 10.100.1.1 power_flow  # live read
franklinwh-direct-connect --host 10.100.1.1 call 1301 --data '{"opt":0}'

franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 5          # poll every 5s
franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 5 --count 12

Every name in catalog is a live subcommand — the command list is generated from the catalog, so the two cannot drift. franklinwh-direct-connect -i <ip> grid_ov_trip works just as power_flow does, and anything uncatalogued is still reachable via call <code>.

--watch [SECONDS] (default 5) reuses one logged-in session and prints a line per poll — a friendly summary for power_flow, compact JSON otherwise. --count N stops after N samples (Ctrl-C otherwise).

Control (live writes)

⚠️ These commands change a live energy system. Operating mode, off-grid/island state and reboot all take effect on real hardware immediately, and some are not visibly reversible from this library alone. Read Compliance & anti-circumvention before using them, and confirm every change in the official FranklinWH app afterwards — the app is the authoritative view of what your gateway is actually doing, and a write that this library reports as accepted is not proof the device applied it.

Confirmed working over LAN TCP/9000 (no SPAN unlock, no cloud) — see catalog.WRITES and docs/PROTOCOL.md. The CLI shape mirrors the sibling tools: -i/--ip for the aGate (as in franklinwh-modbus), and a get-or---set command (as in franklinwh-cloud):

franklinwh-direct-connect -i 192.0.2.110 mode                  # just the current mode
franklinwh-direct-connect -i 192.0.2.110 mode --list           # all modes + details
franklinwh-direct-connect -i 192.0.2.110 mode --json           # decoded dataArea (JSON)
franklinwh-direct-connect -i 192.0.2.110 mode --raw            # full on-the-wire frame (cmdType/snno/crc/...)
franklinwh-direct-connect -i 192.0.2.110 mode --set self       # set; alias tou / self / sc / backup
franklinwh-direct-connect -i 192.0.2.110 mode --set 29287      # ...or a programme id

franklinwh-direct-connect -i 192.0.2.110 offgrid               # show off-grid status
franklinwh-direct-connect -i 192.0.2.110 offgrid --set on --soc 5
franklinwh-direct-connect -i 192.0.2.110 offgrid --set off     # reconnect

In Python:

from franklinwh_direct_connect_api import DirectConnectClient
with DirectConnectClient("192.0.2.110") as c:
    c.login()
    c.set_mode("tou")                  # 1727 {opt:3, current_id}; alias or full name or id

These command a real battery system. mode --set reports current_id before→after so you can confirm it took. Some settings (e.g. smart-circuit SoC cut-off) still round-trip through the cloud — use … call <cmd> --data '…' to experiment with codes not yet wrapped.

Finding new (write/control) commands

The catalog so far is reverse-engineered from read traffic. To discover the write/control codes, capture the app while it issues a control action and look for cmdTypes not yet in the catalog. You don't need Wireshark — macOS/Linux ship tcpdump, and this library de-obfuscates the frames (Wireshark would only show ciphered bytes):

# 1. capture phone <-> aGate :9000 (Direct-Connect hotspot or LAN), then in the
#    app do ONE control action at a time (switch mode, start charge, toggle SC).
sudo tcpdump -i <iface> -s0 -w fwh.pcap 'tcp port 9000'

# 2. triage — lists every cmdType seen; flags the ones NOT in the catalog:
franklinwh-direct-connect analyze fwh.pcap
franklinwh-direct-connect analyze fwh.pcap --unknown    # just the candidate write codes

Or watch the conversation live with a transparent decoding proxy — redirect the app's :9000 to it (ARP-spoof + DNAT, or a host route); it forwards every byte verbatim and prints each decoded frame, flagging unknown cmdTypes:

franklinwh-direct-connect proxy 192.0.2.110          # relay :9000 -> aGate:9000
franklinwh-direct-connect proxy 192.0.2.110 --listen 0.0.0.0:9000
franklinwh-direct-connect proxy 192.0.2.110 --record session.pcap   # capture on demand
#   session.pcap opens in Wireshark and re-decodes: franklinwh-direct-connect decode session.pcap

Unknown odd codes captured during a control action are the requests; their dataArea carries the setpoint. Add confirmed codes to catalog.py.

Or sweep the gateway directly with probe, which tries several request payload shapes per code rather than only the usual {"opt":0}:

franklinwh-direct-connect -i 192.0.2.110 probe                      # all uncatalogued odd codes
franklinwh-direct-connect -i 192.0.2.110 probe --range 1413-1699    # one block
franklinwh-direct-connect -i 192.0.2.110 probe --json > probe.json

Some reads are addressed per battery, not per gateway — the cloud API's per-cell BMS read sends {"fhpSn": "<aPower serial>", "type": 2|3}. A code like that answers a plain {"opt":0} probe with silence, so a single-shape sweep cannot find it. probe auto-discovers the battery serials (from battery_modules + the login manifest), tries each shape, reports which one produced data, and flags replies that look like per-cell telemetry. It only ever sends reads — never opt=1.

Caution: this sends cmdTypes whose semantics are unknown to a real battery system. The payload matrix is read-shaped by construction, but scope your sweeps (--codes, --range) rather than blanket-probing a production gateway.

How the protocol works

A frame is one JSON object. The header is cleartext; everything from "type" onward is obfuscated with a trivial position-based additive cipher:

{"cmdType":<N>,"equipNo":"<E>",   <- cleartext header
"type":...,"timeStamp":...,"snno":...,"len":<L>,"crc":"<C>","dataArea":{...}}
\------------------------ ciphered region (i = 0 here) ----------------------/

encrypt: c[i] = (p[i] + seed + i) & 0xFF
decrypt: p[i] = (c[i] - seed - i) & 0xFF

There is no key, and the seed is derived from the serial in the equipNo header — (sum(utf8(equipNo)) + len(equipNo) + 29) mod 256. That yields 0xA5 for the pre-login 1101 handshake ("00000000") and 0x3F for the reference gateway's 20-char serial; another serial gives another seed, so it must be derived, not hardcoded. Because the first plaintext byte is always ", decoding is self-synchronizing — the seed is recovered from the first ciphered byte, so any frame can be read without knowing the serial. (The formula is voidstarr/franklinwh_local's finding; see docs/PROTOCOL.md.)

Field rules: len is the byte length of the compact dataArea JSON, and crc is its CRC32 (uppercase hex). Full details and the command catalog are in docs/PROTOCOL.md.

Security note

The broker channel is plain TCP and the obfuscation is keyless, so anyone on the LAN path can read and forge frames. Decoded payloads expose WiFi credentials, device serials, firmware versions, and GPS/location. Treat the network segment accordingly.

Before you attach anything to an issue. Packet captures, .pcap files and the output of --raw, proxy and probe contain those same values in clear — WiFi credentials, serial numbers, firmware versions and your location. Redact them first: replace serials and MACs with placeholders, and use the documentation address ranges (192.0.2.x) rather than your own. A capture posted to a public issue is a capture published.

Layout

franklinwh_direct_connect_api/
  protocol.py    cipher, Frame, encode/decode, FrameStream, pcap reader
  catalog.py     cmdType catalog + enums (RUN_STATUS, WRITES, OPERATING_MODES)
  transport.py   TCP client: connect, login, request/response (serialised)
  client.py      high-level named commands (reads + the six writes)
  cli.py         command-line entry point
  discover.py    LAN scan for :9000 / :502
  emulator.py    fake aGate broker, backed by synthetic.py
  synthetic.py   deterministic per-seed synthetic site
  energy.py      1303/1407 helpers: rollups, TOU blocks, tariff tiers
  bms.py         per-cell battery rendering for the `battery` command
  probe.py       read-only cmdType sweep with a payload matrix
  proxy.py       transparent decoding relay
franklinwh_local/  deprecated import shim (to be removed in 0.6.0)
tests/           pytest suite (emulator- and capture-driven)
docs/            the published guide (mkdocs): USAGE, PROTOCOL, API, CLOUD_MAPPING

License

MIT, plus Additional Terms — unofficial and not affiliated with or endorsed by FranklinWH, with a compliance and anti-circumvention clause. See LICENSE for the authoritative text and Disclaimer for the readable version.

Metadata

Release files for franklinwh-direct-connect-api 0.6.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for franklinwh-direct-connect-api 0.6.0
File Size Uploaded Provenance Actions
franklinwh_direct_connect_api-0.6.0.tar.gz 174.9 kB With provenance Details for franklinwh_direct_connect_api-0.6.0.tar.gz

Built distribution (wheel)

Table of built distributions (wheels) for franklinwh-direct-connect-api 0.6.0
File Interpreter ABI Platform Actions
franklinwh_direct_connect_api-0.6.0-py3-none-any.whl Python 3 none any Details for franklinwh_direct_connect_api-0.6.0-py3-none-any.whl

Total release size: 304.5 kB

Release files / franklinwh_direct_connect_api-0.6.0.tar.gz

Download URL franklinwh_direct_connect_api-0.6.0.tar.gz
Size 174.9 kB
Tags Source
SHA-256 checksum
How to use checksums
80a0ae9b7b5833ec21c329444741bf6c49f5ff30bd284a08a3ab693f7f46d9cc
BLAKE2b-256 checksum
How to use checksums
2b52ad72d2c64ab6184527018d6d0f16cdb4a4c7b5bdd8dc62a7f3c7ef3d7cbb
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.

Transparency log

Release files / franklinwh_direct_connect_api-0.6.0-py3-none-any.whl

Download URL franklinwh_direct_connect_api-0.6.0-py3-none-any.whl
Size 129.6 kB
Tags Python 3
SHA-256 checksum
How to use checksums
ba4b1b98f05ffcc63328dba7259207bf28255571fe5dfc5284b73b683acf8414
BLAKE2b-256 checksum
How to use checksums
5b7f5daa3a0a87fbde69c7e21bfb57fc2ba9b972b558f8225608207effd3e586
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.16

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.

Transparency log

Security for franklinwh-direct-connect-api 0.6.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

Full provenance

Both files in this release have been uploaded with provenance metadata.

Select from 2 files

Attestation for franklinwh_direct_connect_api-0.6.0.tar.gz

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Nov 3, 2026.

Transparency log

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page