The Heat Pump Lab
The Heat Pump Lab, from the Ahuora Centre at the University of Waikato, is a Python package for building and analysing high-temperature heat pump cycles. It solves steady-state cycle designs with real-fluid properties, including zeotropic refrigerant mixtures and transcritical and supercritical operation, and reports COP, pressures, compressor duties and heat-exchanger approaches.
The package contains eleven cycle models. Each is a module under HeatPumpLab.cycles:
| Cycle | Module | What it models | Reference |
|---|---|---|---|
| Recuperative heat pump (RHP) | RecuperativeHeatPump |
One or two compressors with up to three recuperative heat exchangers (RHX) placed between the gas coolers, for high-temperature glide heating. Includes Bayesian optimisation of the design. | [1] |
| Split-stream heat pump (SLTHP) | SplitHeatPump |
Two-stage cycle with RHX1 in parallel with the low-temperature gas cooler. | [1] |
| Steam-generating heat pump | ConventionalHeatPump |
Single-stage rating model with compressor maps, heat losses and steam raising. | [2] |
| Transcritical–transcritical CO₂ cascade | TTCascadeHeatPump |
The bottom cycle gives its heat to the top cycle's suction gas in a cascade gas cooler; the top cycle heats the air in two gas coolers, with optional secondary air. IHXs in both cycles, optional expanders. | [3–5] |
| n-level cascade | CascadeHeatPump |
Two to four levels heating the air in series through each level's subcooler and its share of condenser heat. Optional IHX per level and expanders. | [6] |
| Heat pump with MVR steam | MVRHeatPump |
A vapour-compression cycle heats the air and raises low-pressure steam, which a chain of mechanical vapour recompression fans, with water injection and splits to the process, lifts to heat the air to the target. | [2] |
| sCO₂ reverse Brayton heat pump | BraytonHeatPump |
Supercritical CO₂ cycle with split compression, a preheater, an IHX and a turbine expander, architectures 1 and 2. | [7] |
| Two-stage economiser heat pump | EconomiserHeatPump |
Two-stage cycle with a flash tank, a closed economiser (vapour injection) or parallel compression, or single-stage for comparison; optimises the intermediate pressure. | [8, 9] |
| Multi-pressure condensation heat pump | MultiPressureHeatPump |
One evaporator and n condensing pressures (2–5) in series on the air, each with its own compressor; each condenser's liquid is throttled into the one below. Optimises the lower condensing temperatures. DualPressureHeatPump is the two-pressure case. |
[10] |
| Reverse-Stirling heat pump | StirlingHeatPump |
Semi-empirical block: a fraction of the Carnot COP per unit, one to four units in series on the air. Indicative only. | [11, 12] |
| Ammonia–water hybrid heat pump | HybridHeatPump |
Absorption–compression (Osenbrück) cycle: desorber, separator, compressor with optional wet compression, solution pump and absorber heating the air. Properties from the IAPWS 2001 ammonia–water formulation through teqp (ammonia-water extra). |
[13, 14] |
Web apps
Two of the models also run in the browser, with CoolProp compiled to WebAssembly. Nothing is installed and no inputs leave the browser:
- Advanced dryer heat pumps (
apps/dryer): the RHP, SLTHP, cascade, HP + MVR, sCO₂ Brayton, flash tank / economiser, multi-pressure, Stirling and ammonia–water hybrid cycles, solved live, plus the results of the REFPROP design study. - Steam-generating heat pump (
apps/steam): the single-stage cycle raising steam, with compressor maps, saved cases, side-by-side comparison and sweeps.
A landing page (apps/index.html) links the two, and their sources and build scripts are
in apps/src. The apps are published at
https://waikato-ahuora-smart-energy-systems.github.io/HeatPumpLab/. To run them locally:
python3 -m http.server 8000 --directory apps
Then open http://localhost:8000. The Python models reproduce the apps' results.
Requirements
-
Python 3.12 to 3.14, and uv (recommended) or pip.
-
Fluid properties come from CoolProp (free, installed with the package) by default, for every cycle. Mixtures use phase-imposed flashes with cached bubble and dew points, plus a phase-envelope fallback near the critical point, so zeotropic blends solve robustly and quickly.
-
NIST REFPROP 10 (optional) can be used instead. REFPROP is commercial software and is not included; you need your own licence. HeatPumpLab looks for it at:
- macOS:
/Library/REFPROP/(librefprop.dylib,librefprop-source.dylib,librefprop-sink.dylib) - Windows:
C:/Program Files (x86)/REFPROP/(REFPROP.DLL,REFPROP-source.DLL,REFPROP-sink.DLL)
The three library files are copies of the same REFPROP library, so the refrigerant, source and sink fluids can be loaded at the same time.
- macOS:
Installation
From PyPI:
pip install heatpumplab # or: uv add heatpumplab
pip install "heatpumplab[refprop]" # optional: the REFPROP backend (needs a REFPROP installation)
pip install "heatpumplab[ammonia-water]" # optional: ammonia-water properties (teqp) for HybridHeatPump
From source, to run the tests, the research scripts or the latest development version:
git clone https://github.com/waikato-ahuora-smart-energy-systems/HeatPumpLab.git
cd HeatPumpLab
uv sync # core dependencies (including CoolProp), and the package itself
uv sync --extra refprop # optional: the REFPROP backend (needs a REFPROP installation)
uv sync --extra ammonia-water # optional: ammonia-water properties (teqp) for HybridHeatPump
uv sync --group dev # optional: pytest and ruff
To use REFPROP, set HEATPUMPLAB_PROPERTY_BACKEND=refprop, or pass property_backend="refprop"
to the steam-generating heat pump's configuration (ConventionalHPConfig). The two backends
agree closely; mixture results can differ slightly where their binary interaction parameters
differ, and absolute enthalpies and entropies of some mixtures differ by a constant (reference
state), which does not affect cycle results. The fluid property overview table
(get_fluid_prop_overview_table) uses REFPROP-only outputs such as ODP and GWP.
Run the examples below with python your_script.py, or uv run python your_script.py in a source checkout.
Quick start
Recuperative heat pump
from HeatPumpLab.cycles.RecuperativeHeatPump import RecuperativeHP
hp = RecuperativeHP(
refrigerant="Propane;Isopentane|0.2;0.8|mass", # components; fractions; basis
T_source_in=40.0, # heat source (water) inlet, °C
Tref_evap_inlet=10.0, # refrigerant entering the evaporator, °C
T_air_inlet=15.0, # sink (air) inlet, °C
T_air_tar=200.0, # sink outlet target, °C
dT_GC_min_tar=20.0, # gas-cooler minimum approach, K
dTmin_rhx=5.0, # recuperator minimum approach, K
n_comp=2, # compression stages
dT_rhx1_cold=60.0, # RHX1 lift on the stage-1 suction, K
dT_rhx2_cold=0.0, # RHX2 lift before stage 2, K
comp2_power_frac=0.5, # pressure-ratio allocation to stage 2
sink="Air",
source="water",
).solve()
print(hp.converged, hp.COP) # True 2.59
print(hp.get_report()["Pmax"]) # maximum pressure, kPa
Design optimisation
optimise_recuperative_heat_pump searches the RHX lifts, stage allocation and, optionally, the
mixture composition with Bayesian optimisation (BoTorch). Solves run in worker processes, so
call it from a script with a main guard:
from HeatPumpLab.cycles.RecuperativeHeatPump.optimisation import (
OuterDesignOptimisationConfig, optimise_recuperative_heat_pump,
)
if __name__ == "__main__":
result = optimise_recuperative_heat_pump(
refrigerant="Propane;Butane|0.3;0.7|mass",
config=OuterDesignOptimisationConfig(
max_exact_evaluations=200, seed=20260910,
vary_composition=False, preserve_incumbent=False,
),
)
print(result.best.cop, result.best.x)
A 200-evaluation search takes roughly ten to fifteen minutes on a laptop. See the optimisation protocol for the settings and their limits.
Split-stream heat pump
from HeatPumpLab.cycles.SplitHeatPump import SplitHeatPump, SplitHPConfig
res = SplitHeatPump(SplitHPConfig(
refrigerant="Propane;Isopentane|0.2;0.8|mass",
dT_rhx1_cold=80.0, # RHX1 lift, K
)).solve()
print(res.success, res.COP, res.P_H) # gas-cooler pressure, MPa
Steam-generating heat pump
from HeatPumpLab.cycles.ConventionalHeatPump import ConventionalHeatPump, ConventionalHPConfig
res = ConventionalHeatPump(ConventionalHPConfig()).solve() # n-butane, Recip-M compressor map
res = ConventionalHeatPump(ConventionalHPConfig(T_evap=40.0, T_cond=110.0)).solve()
print(res.COP, res.report["Q_heat_kW"], res.report["T_discharge"])
# REFPROP instead of CoolProp (needs `uv sync --extra refprop` and a REFPROP installation)
res = ConventionalHeatPump(ConventionalHPConfig(property_backend="refprop")).solve()
The defaults model n-butane on the Recip-M reciprocating compressor map, raising 120 °C steam from a 55 °C
heat source, with hot water from the subcooler. Compressors can be described by efficiency maps,
efficiency against pressure ratio, or EN 12900 polynomials (compressor_curves.py).
Refrigerants
Fluids use REFPROP-style names (Propane, Butane, Isopentane, ...), which are mapped to
CoolProp's names automatically. A mixture is written as "Fluid1;Fluid2|x1;x2|basis" with basis mass
or mol, for example "Propane;Isopentane|0.2;0.8|mass". Ternary mixtures use the same form.
Repository layout
HeatPumpLab/
components/ compressors, heat exchangers, valves, streams and solver relationships
cycles/ one module per cycle (see the table above), and shared helpers in common/
utils/ property packages (CoolProp, REFPROP), caching, parallel solving, plotting
apps/ web apps: landing page, dryer/ and steam/ (published with GitHub Pages)
src/ the apps' JavaScript sources and build scripts
docs/dev-notes/ development notes (recuperative heat pump solver and optimiser)
tests/ test suite
scripts/ research search scripts for the recuperative heat pump (Pareto, MOBO, trust region)
Tests
uv sync --group dev
uv run pytest
Tests that check the REFPROP backend skip automatically when it is not installed.
Further documentation
- ABOUT.md: the recuperative heat pump cycle variants
- BAYESIAN_OPTIMISATION.md: the production optimiser
docs/dev-notes/rhp/: development notes on the recuperative heat pump solver and optimiser, including the optimiser benchmarks (OPTIMISER_COMPARISON.md, ORIGIN_OPTIMISER_COMPARISON.md) and the solver fixes by evaluation versionapps/src/: the web apps' sources and how to rebuild them
References
- T.G. Walmsley, K.-M. Adamson, C. Arpagaus, F. Schlosser, Recuperative heat pump cycle concept for high-temperature glide process heating applications, Applied Thermal Engineering 301 (2026) 131660. https://doi.org/10.1016/j.applthermaleng.2026.131660
- T.G. Walmsley, B. Ong, K. Hall, B. Lincoln, F. Schlosser, J. Walden, R. Padullés, D. Hoang, M. Walmsley, C. Arpagaus, Steam cogeneration heat pumps for the food, dairy and meat industries, in: 5th High-Temperature Heat Pump Symposium 2026, Book of Presentations, Copenhagen, Denmark, February 2026, pp. 270–275.
- L. Kong, New high temperature transcritical CO₂ heat pump concept for spray drying, PhD thesis, The University of Waikato (2026). https://hdl.handle.net/10289/18056 (the TT cascade model follows cycle TT-4, with the additional gas cooler)
- L. Kong, T.G. Walmsley, D.K. Hoang, F. Schlosser, Q. Chen, J.K. Carson, D.J. Cleland, Transcritical-transcritical cascade CO₂ heat pump cycles for high-temperature heating: A numerical evaluation, Applied Thermal Engineering 238 (2024) 122005. https://doi.org/10.1016/j.applthermaleng.2023.122005
- L. Kong, F. Schlosser, S. Kloeppel, J.K. Carson, D.J. Cleland, T.G. Walmsley, Transcritical–transcritical cascade CO₂ heat pump with expansion work recovery: A thermodynamic analysis, Energies 19 (2026) 3767. https://doi.org/10.3390/en19163767
- D.K. Hoang, T.G. Walmsley, D.J. Cleland, Q. Chen, J.K. Carson, Thermo-economic investigation and multi objective optimization of cascade high temperature heat pump using low global warming refrigerants, Applied Thermal Engineering 279 (2025) 127901. https://doi.org/10.1016/j.applthermaleng.2025.127901
- V. Dalal, S. Klöppel, C. Rose, T.G. Walmsley, Evaluating sCO₂ heat pump architectures for large-scale industrial air drying above 150 °C, European sCO₂ Conference (Euro sCO₂ 2027), under review.
- C. Arpagaus, F. Bless, M. Uhlmann, J. Schiffmann, S.S. Bertsch, High temperature heat pumps: Market overview, state of the art, research status, refrigerants, and application potentials, Energy 152 (2018) 985–1010. https://doi.org/10.1016/j.energy.2018.03.166
- K.-M. Adamson, T.G. Walmsley, J.K. Carson, Q. Chen, F. Schlosser, L. Kong, D.J. Cleland, High-temperature and transcritical heat pump cycles and advancements: A review, Renewable and Sustainable Energy Reviews 167 (2022) 112798. https://doi.org/10.1016/j.rser.2022.112798
- B. Dai, X. Liu, S. Liu, Y. Zhang, D. Zhong, Y. Feng, V. Nian, Y. Hao, Dual-pressure condensation high temperature heat pump system for waste heat recovery: Energetic and exergetic assessment, Energy Conversion and Management 218 (2020) 112997. https://doi.org/10.1016/j.enconman.2020.112997
- N. Häggqvist, T. Tveit, R. Zevenhoven, Combining measurements and simulation for condition monitoring and performance optimization of an alpha-configuration double-acting high-temperature Stirling cycle-based heat pump, Case Studies in Thermal Engineering 47 (2023) 103066. https://doi.org/10.1016/j.csite.2023.103066
- Høeg et al., Performance evaluation of industrial heat pump based on reversed Stirling cycle for ultra-high temperature applications, IEA Heat Pump Conference (2026).
- J.K. Jensen, W.B. Markussen, L. Reinholdt, B. Elmegaard, On the development of high temperature ammonia–water hybrid absorption–compression heat pumps, International Journal of Refrigeration 58 (2015) 79–89. https://doi.org/10.1016/j.ijrefrig.2015.06.006
- R. Tillner-Roth, D.G. Friend, A Helmholtz free energy formulation of the thermodynamic properties of the mixture {water + ammonia}, Journal of Physical and Chemical Reference Data 27 (1998) 63–96. https://doi.org/10.1063/1.556015 (IAPWS Guideline G4-01, 2001)
Citing
If you use HeatPumpLab in published work, please cite reference [1], and the reference for any
other cycle you use. To cite the software itself, use its Zenodo DOI,
10.5281/zenodo.23604060, which always resolves to the
latest release. GitHub's "Cite this repository" button gives both, from CITATION.cff.
Contributing
Bug reports, questions and contributions are welcome; see CONTRIBUTING.md.
Licence
Copyright 2021–2026 The University of Waikato.
Licensed under the Apache License, Version 2.0. See LICENSE.
Contact
Tim Walmsley, Ahuora Centre, University of Waikato: tim.walmsley@waikato.ac.nz
Metadata
Release files for heatpumplab 0.2.1
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| heatpumplab-0.2.1.tar.gz | 246.4 kB | With provenance | Details for heatpumplab-0.2.1.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| heatpumplab-0.2.1-py3-none-any.whl | Python 3 | none | any | Details for heatpumplab-0.2.1-py3-none-any.whl |
Total release size: 550.1 kB
Release files / heatpumplab-0.2.1.tar.gz
| Download URL | heatpumplab-0.2.1.tar.gz |
|---|---|
| Size | 246.4 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
b73da30cfb1a02e107ba3a5f6b8af35ddaba1d9a4d67c02db8fd6233ee77e3d0
|
|
BLAKE2b-256 checksum How to use checksums |
f9f230aa9c8d4576bb0a91ea7b66232e82f20d2540cbe4d1b7efe03adf5c0ef9
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Oct 28, 2026.
Transparency logRelease files / heatpumplab-0.2.1-py3-none-any.whl
| Download URL | heatpumplab-0.2.1-py3-none-any.whl |
|---|---|
| Size | 303.7 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
c9fdd447f1c3c1ddfb9ec6760f2f28e32a865935c44c80b545a074271c58134a
|
|
BLAKE2b-256 checksum How to use checksums |
c3d43fae5462618cfb03fabe1647754c4af7fa6127c941f701148e40be793ffe
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Oct 28, 2026.
Transparency logSecurity for heatpumplab 0.2.1
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
Both files in this release have been uploaded with provenance metadata.
Attestation for heatpumplab-0.2.1.tar.gz
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Oct 28, 2026.
Transparency logA note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.