Hue Python SDK
For frozen datasets, local experiments, custom scorers, durable retries and historical rescoring, see Local evaluations.
Python helpers around the official OpenTelemetry trace and log SDKs and OTLP HTTP/protobuf exporters. opentelemetry-api, opentelemetry-sdk and opentelemetry-exporter-otlp-proto-http are accepted as >=1.40,<2; 1.44.0 is the certified lockfile combination and 1.40.0 is tested as the floor in CI. Provider requests run in your application. This package does not proxy model calls or configure global OTel providers.
The distribution is named hue-run (import hue_sdk). Python 3.10+ is supported by the package contract; recorded validation below identifies the tested runtime.
Install
pip install hue-run
# Or, in a uv project:
uv add hue-run
Send a trace
In the consuming application, use only public imports:
import os
from hue_sdk import Hue
with Hue(
api_key=os.environ["HUE_API_KEY"],
capture_content=False, # Required: choose explicitly.
) as hue:
project = hue.validate_project()
with hue.context(session_id="conversation-42", user_id="observed-user-7"):
with hue.span("agent.run") as run:
run.set_input({"question": "What is 2 + 2?"})
with hue.tool("add") as tool:
tool.set_input({"a": 2, "b": 2})
tool.set_output(4)
run.set_output({"answer": 4})
if not hue.force_flush():
raise RuntimeError("Telemetry export failed; inspect Hue export_status.")
The SDK uses https://app.hue.run by default. Set base_url only for a different Hue deployment or a local receiver, using an origin without an API suffix. Existing Hue(base_url, api_key, ...) calls remain supported; a bare key passed as the first positional argument raises TypeError pointing at api_key=. The project service key determines the project. The SDK validates the project at GET /api/v1/projects/current when explicitly requested; construction itself does not perform a request. HTTP is permitted only for localhost and loopback IPs. Userinfo, query strings, fragments, paths and redirects are rejected. The key is sent only as Authorization: Bearer …; repr(hue), SDK errors and status counters omit it.
Content and semantic fields
capture_content has no default. False makes set_input and set_output omit content before it reaches an OTel queue and makes log_inference emit no record. Explicit JSON null, empty strings and absent content stay distinct when capture is enabled. Exception recording includes the exception type and ERROR status; exception messages and stacks are always excluded by these helpers.
When capture is disabled Hue also strips recognized GenAI, OpenInference, OpenLLMetry and Vercel AI SDK content attributes (including OpenInference retrieval documents, embeddings, reranker documents, prompt-template variables and images), legacy gen_ai.* message events, log bodies and status descriptions from every record it exports, including spans produced by third-party instrumentors on the same provider. COMPATIBILITY.md lists the exact keys. This setting is still not a blanket PII filter: custom attribute names, span names, session/user identifiers and resource attributes cannot be classified automatically and remain under your control, and other exporters keep their own policy. The server stores received content; there is no automatic telemetry expiry. Delete scoped data explicitly when required by your retention policy.
Use redactor=lambda field, value: ... to transform content in supported helpers. It runs synchronously before serialization and export. Return a redacted JSON value; failures omit the field and increment export_status.instrumentation_failures without changing application behavior. It does not inspect arbitrary OTel attributes or logs:
def redact(field, value):
if isinstance(value, dict):
return {key: "[redacted]" if key == "email" else item for key, item in value.items()}
return value
The callback should cover your actual nested input format; this small example is only a top-level dictionary transformation.
Before redaction, helpers copy supported content into detached built-in containers; in-place changes by a redactor cannot change application inputs or results. The input and the redactor's returned value each have a 1 MiB conservative value budget, 64 maximum nesting depth and 65,536 visited values/keys. Integers and integer keys are limited to 14,000 bits before decimal conversion. Final serialized content still has the 256 KiB UTF-8 JSON limit. Cyclic, nonfinite, unsupported or over-budget content is omitted and counted as an instrumentation failure. See the Python safety boundary for supported types and callback limits.
| Helper | Attributes / behavior |
|---|---|
span(name) |
Generic input.value / output.value, optional OTel attributes and kind |
model(model, provider=...) |
gen_ai.operation.name, gen_ai.request.model, gen_ai.provider.name; message content in gen_ai.input.messages / gen_ai.output.messages |
tool(name, call_id=...) |
gen_ai.operation.name=execute_tool, gen_ai.tool.name, call ID, arguments and result |
context(session_id=..., user_id=...) |
Task-local gen_ai.conversation.id / user.id on nested Hue helpers; observed users are not Hue account identities |
span.set_usage(...) |
Nonnegative reported gen_ai.usage.input_tokens / output_tokens; None leaves a field absent |
span.log_inference(input=..., output=...) |
Correlated gen_ai.client.inference.operation.details log linked to that span: structured body plus request metadata and session attributes |
span.record_error(error) |
Exception type event and ERROR status; context managers also record escaping errors/cancellation |
Hue.inject(headers) / Hue.extract(headers) |
W3C trace context propagation; pass extracted context to span(parent_context=...) |
Tool/model metadata accepts plain strings; invalid values use stable fallback labels and increment instrumentation failures without invoking custom conversion hooks. Disabled tracing skips metadata validation.
For model helpers, pass the message representation produced by your integration. Prefer current GenAI message conventions when authoring your own messages. Use either span content or correlated logs for a given input/output, avoiding duplicate copies. log_inference sends a structured body (an explicit None field keeps its key with an empty value, distinct from an absent field) and copies gen_ai.operation.name, gen_ai.provider.name and gen_ai.request.model from the enclosing model() block, or from its operation=, provider= and model= keywords, plus gen_ai.conversation.id from context(), onto the record's attributes. A blank or over-long keyword is omitted and counted as an instrumentation failure.
Existing instrumentation
Pass an existing opentelemetry.sdk.trace.TracerProvider through tracer_provider=provider to add Hue's exporter, and an existing opentelemetry.sdk._logs.LoggerProvider through logger_provider= when the application already owns one. A provider Hue creates for the other signal reuses the borrowed provider's resource, so spans and correlated logs report the same service.name; service_name applies only when Hue creates both providers. Hue's processor then exports every span that ends on that provider, the same default as other OpenTelemetry exporters; wrap the processor if only part of the provider's spans should reach Hue. Session/user identifiers from hue.context() are stamped on Hue helper spans only. Hue does not call set_tracer_provider. It exposes hue.tracer_provider, hue.tracer and hue.logger_provider for explicit integration. shutdown() closes Hue's processors; borrowed providers and their other processors stay usable. Finish traced work before shutting Hue down: spans ending or external records emitted afterward increment Hue's dropped-record counters, including emissions through a borrowed provider. New Hue helpers after shutdown are no-ops. Do not repeatedly attach Hue clients to one long-lived provider: OTel has no public processor-removal API. Create one client per provider lifecycle.
An instrumentor that accepts tracer_provider can receive hue.tracer_provider; follow that instrumentor's own capture/redaction configuration. OpenInference and other OTel instrumentors are optional dependencies, not implicitly enabled. Hue's export path strips their recognized content attributes when capture_content is False, but configure their own capture controls as well: unrecognized custom keys pass through, and the instrumentor may still send content to other exporters. The optional compatibility group pins OpenAI 3.14.0, OpenInference OpenAI 0.1.60 and its resolved OpenInference instrumentation 0.1.63. A synthetic HTTP streaming response verifies parentage, canonical model/usage attributes and enabled/disabled message capture with TraceConfig(enable_genai_semconv=True, hide_inputs=..., hide_outputs=..., hide_input_messages=..., hide_output_messages=...). This is a tested adapter combination, not a claim about all OpenAI APIs or live-provider compatibility. See the instrumentor's official source. See the Python integration guide for application setup.
Local development without a Hue account
Hue speaks standard OTLP, so any local collector works. Point base_url at a loopback receiver that accepts /api/v1/otlp/v1/traces and /api/v1/otlp/v1/logs (for example an OpenTelemetry Collector otlp receiver with http.traces_url_path and logs_url_path set to those paths, forwarding to Jaeger or the debug exporter) and pass any placeholder api_key; HTTP is allowed for loopback origins. validate_project() and verify_trace() are Hue-only diagnostics and are not available against a generic collector.
Export behavior and limits
- Traces go to
/api/v1/otlp/v1/traces; correlated logs go to/api/v1/otlp/v1/logs. Both use the official OTLP HTTP/protobuf exporter with gzip-compressed request bodies and ahue-sdk-python/<version>User-Agent ahead of the exporter's own token. The official exporter handles retryable network/service failures; Hue additionally honors 429 and Retry-After within its transport budget. There is no proprietary provider transport. - Exporter work and its HTTP worker run with OpenTelemetry instrumentation suppressed. Hue ignores records emitted within that suppressed scope, preventing HTTP instrumentation and exporter diagnostics from feeding back into its own queues. Application instrumentation resumes outside that scope. If an OpenTelemetry release ever stops exposing its suppression key, Hue warns once at import and keeps exporting: its own queues still ignore its export work, but OTel HTTP instrumentors could then record Hue's export requests on other exporters.
- Batches initially contain at most 64 records and are split by encoded protobuf size to fit 1 MiB, both on wire and after decoding. A single oversized record fails visibly through export status. Helper content exceeding 256 KiB UTF-8 JSON is omitted before enqueue and increments instrumentation failures; it is never silently truncated by Hue. Third-party record validation remains the receiver's responsibility. OTel's own attribute/count/environment limits can still affect externally configured providers.
- Hue accepts at most 2,000 distinct spans per trace. This is enforced by the receiver across distributed producers; the client cannot guarantee a global count.
- HTTP errors, malformed/non-200 success responses and OTLP
partial_successrejected counts cause a failed export status. Partial rejection is not retried wholesale. Receiver error text is not echoed. A warning-only partial-success response with zero rejected records remains successful. force_flush(timeout_millis=30000)drains both processors and returnsFalsefor a timeout, failed export, dropped record or instrumentation omission since this client was created. Hue's processors honor the shared deadline and serialize drains in a bounded background worker. Pending exports continue after timeout.export_statusexposes cumulative failure counters.shutdown()stops new helpers, drains and closes owned exporters within the caller's wait budget; repeated calls wait for the same shutdown. After a timeout, keep the process alive and call shutdown again to confirm completion. Context-manager exit callsshutdown_safe(timeout_millis=1000); check flush explicitly when an exit code must reflect delivery failure.- Hue processors use the public OTel interfaces and bound each signal to 2,048 records and 8 MiB of encoded telemetry by default, including in-flight records (
max_queue_size,max_queue_bytes). Dropped records and instrumentation omissions make cumulativeexport_status.okfalse. Queue overflow, process termination and sampling can lose telemetry. Flush success reports observed exporter outcomes, not durable local delivery or proof that every application operation was instrumented. The exporter timeout controls individual export/retry operations. A caller timeout does not cancel an HTTP request already in flight; background workers continue until the operation completes. - A timed-out HTTP worker can retain one encoded request of up to 1 MiB per signal outside the queue counters. Later records remain queued within the configured limits until that worker finishes; shutdown counts any queued records it must discard. Queue bytes are not total process memory.
- A flush timeout releases drain coordination so later flushes can make progress. Both signals share the caller's remaining wait budget, including time spent waiting for another flush. Shutdown's exporter cleanup can continue after the caller returns without holding that coordination lock. Repeated shutdown calls report current failures and drops as well as cleanup completion.
Dependencies
The tracing core depends on the official OpenTelemetry packages and requests only. JSON Schema
scoring (builtin_scorers.json_schema) runs jsonschema in an isolated process and needs the optional
extra; without it builtin_scorers.json_schema raises ImportError and stored schema scorers report
SchemaValidatorUnavailable:
pip install 'hue-run[evals]'
Import the bundle as from hue_sdk.evals import builtin_scorers. The builtins name remains as an
alias for parity with TypeScript, but it shadows the standard-library module of the same name inside
any file that imports it.
See THIRD_PARTY_NOTICES.md for licenses.
Confirm a trace reached Hue
Hue.verify_trace() checks a server receipt for a known trace from a real application request.
It does not send a synthetic trace, invoke a model, or flush an exporter. Finish the request,
then flush the provider that produced it. If you borrow a provider, call its force_flush()
first, then check Hue's force_flush() result before verifying:
# Retain these IDs while your application's instrumented request runs.
# After the request finishes and the relevant providers have flushed:
confirmation = hue.verify_trace(
request_trace_id,
expected_span_ids=[request_span_id, model_span_id],
required_fields=["input", "output", "model", "usage", "session"],
timeout_millis=10_000,
)
if confirmation.verified:
print(confirmation.receipt.trace_url)
else:
# The latest partial receipt, or None if this trace has not appeared yet.
print(confirmation.receipt)
Only require fields your instrumentation emits and your capture policy permits. For metadata-only
capture, omit input and output. The receipt contains presence booleans and counts, not captured
content. verified=True confirms the requested trace, every supplied expected span, and every
required field; it does not prove that unlisted application operations were instrumented. Missing
spans or fields continue polling until the deadline, then return verified=False with the latest
receipt. Trace IDs must be nonzero and contain 32 lowercase hexadecimal characters; expected span
IDs must be nonzero, contain 16, be unique, and number at most 100. The timeout must be positive
and at most 60,000 ms.
Only trace-not-found responses, HTTP 429 and HTTP 503 are retried. Authentication, unsupported
receipt endpoints, malformed responses and connection failures raise TraceVerificationError
with a safe code and optional status_code; response bodies and keys are omitted. Redirects
are rejected. The deadline covers connection, polling and response-body reads. An in-flight network
read may finish in the background after the caller times out. This helper requires a Hue deployment
that implements /api/v1/traces/{traceId}/receipt.
Supported runtimes and verification
Python 3.10+ is supported. CI tests Python 3.10 and 3.14, source imports and an independently installed wheel. Tests use synthetic loopback HTTP receivers and decode official OTLP protobuf messages to verify trace/log correlation, metadata-only capture, redaction, propagation, existing-provider ownership, authentication failures, redirects, partial rejection, retries and encoded request limits. Compatibility tests also exercise local evaluations and the optional OpenInference adapter. No live model provider is required for these checks.
See the documentation for integration guidance and troubleshooting for export failures.
Managed targets
Start a frozen dataset run in Hue while your existing agent stays in your application:
import os
from hue_sdk.managed import ManagedTargetHandler, ManagedTargetResult
def target(invocation):
# Your function consumes unchanged inputs and verified attachment bytes.
result = run_agent_for_evaluation(invocation)
return ManagedTargetResult(output=result)
handler = ManagedTargetHandler(
machine_credential=os.environ["HUE_MANAGED_TARGET_SECRET"],
target=target,
tracer=hue.tracer, # Required with a Hue-owned client: Hue never sets a global tracer.
flush_telemetry=hue.force_flush, # Existing client; False keeps telemetry pending.
)
Without tracer, the handler falls back to the global OpenTelemetry tracer, its span is not
recorded and every invocation returns uncertain.
Your POST route calls handler.handle(raw_body_bytes, request_headers) and returns
its JSON body, status code and headers. Limit request bodies to 1 MiB; use
asyncio.to_thread from an async route. The target must honor cancelled and
deadline_monotonic. Use a 120-second host limit for the default 90-second callback
and 30-second finalization budget.
For generated files, return ManagedOutputFile entries containing actual bytes,
filename, content type and an optional primary flag. The helper claims the
invocation, verifies files and saves the outcome without automatically rerunning
the agent. See the managed-run guide
and full adapter contract for registration, existing-provider
flush callbacks and recovery. Local/CI runners remain available.
Serving safely
Use create_hue_safe for best-effort startup and enabled=False for a local kill switch. The safe constructor returns a disabled client and records an instrumentation failure if initialization fails. Disabled helpers execute application work without exporting. Initialize after fork, once per serving process. force_flush_safe(timeout_millis=1000) and shutdown_safe(timeout_millis=1000) return booleans without raising; monitor those results and export_status. Keep strict project validation and receipt/delivery checks out of customer request paths. Never rerun application work to recover telemetry.
Queue bytes bound retained telemetry rather than total RSS. Network waits have a wall-clock caller bound and at most one retained HTTP worker per signal; a stuck OS call can outlive that wait. Arbitrary user hooks and third-party instrumentation retain their own behavior. See production safety for lifecycle examples, failure tests and limitations.
Release files for hue-run 0.2.2
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | |
|---|---|---|---|
| hue_run-0.2.2.tar.gz | 212.2 kB | Details |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Reset |
|---|---|---|---|---|
| hue_run-0.2.2-py3-none-any.whl | Python 3 | none | any | Details |
Total release size: 270.2 kB
Release files / hue_run-0.2.2.tar.gz
| Download URL | hue_run-0.2.2.tar.gz |
|---|---|
| Size | 212.2 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
45bef72a434706a9a6d8172a23ed483b54f468b5b363b5ec62e3fcee557996c2
|
|
BLAKE2b-256 checksum How to use checksums |
225586f98061beb31d8f4769dd9c5ec9484f31c7b322d8deb6c0a7153c74e850
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.14
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Sep 18, 2026.
Transparency logRelease files / hue_run-0.2.2-py3-none-any.whl
| Download URL | hue_run-0.2.2-py3-none-any.whl |
|---|---|
| Size | 58.1 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
8eb1f037528de5770df2321f975229dbae5b62d2132ec9f31aac89af6597fcfe
|
|
BLAKE2b-256 checksum How to use checksums |
1a96d7189e2c152afc355ca8d6733c820dd33600e9f85b8188ae30f123b7d14d
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.14
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Sep 18, 2026.
Transparency log