Skip to main content

iec61850

Async-first, type-hinted IEC 61850 MMS client and server for Python.

Scope and protocol boundaries

This package is an MMS-only facade over iec61850-rust — an independent Rust implementation of IEC 61850 by the same author, itself open source under the same MIT OR Apache-2.0 terms and published on crates.io as the iec61850-* crates. This facade covers the connection-oriented, application-level services that fit Python's runtime characteristics naturally:

  • Client: read / write / control / dataset / reporting (URCB + BRCB) / log query / GOOSE control block administration / SCL parsing / directory queries / server identity and status / TLS
  • Server hosting: MMS server with URCB / BRCB / LCB / GoCB / SGCB / control handlers, declared from SCL or from a Python dict spec

Out of scope by design: GOOSE (IEC 61850-8-1) and Sampled Values (IEC 61850-9-2) are hard-real-time L2 protocols (GOOSE T1 = 4 ms, SV = 250 us / 4 kHz). Their timing budgets fit Rust + SCHED_FIFO, not a GIL-bound runtime with non-deterministic GC pauses. Misrepresenting them as "supported" in Python would invite production protection-scheme failures.

If you need GOOSE / SV publish or subscribe, use the upstream Rust crates directly (same author, same wire-level implementation):

  • iec61850-goose — GOOSE publisher / subscriber / receiver (Ethernet L2 raw socket, frame template, retransmission state machine)
  • iec61850-sv — Sampled Values 4 kHz publisher + subscriber (Linux SCHED_FIFO publish loop, p99 jitter target < 200 us)

The PICS table below uses a four-column Py-C / Py-S / Rust-C / Rust-S breakdown precisely so an unsupported Python row points you at the right Rust crate.

Features

  • TCP connect / disconnect with timeout
  • TLS connect (IEC 62351-3 cipher whitelist, mutual TLS, TLS 1.2 + 1.3, known-peer pinning, CRL, hostname and time validation knobs; the certificate chain is always validated, and a failed handshake raises IedTlsError naming its kind)
  • Per-connection tuning: request timeout, max outstanding invocations, local max PDU size
  • High-level Iec61850Client async context manager wrapping the lifecycle of an IedConnection plus an optional background ReportDispatcher
  • Typed scalar read / write: bool, int32, int64, uint32, float, float64, string, timestamp (decoded to datetime), quality (decoded to a Quality dataclass), and bit_string as (data, padding)
  • Generic read / write with array-element and sub-component selection; write also takes a tagged value dict for types no Python type selects
  • Directory queries: get_server_directory, get_logical_device_directory, get_logical_node_directory(AcsiClass), get_data_directory; a walk stops past max_name_list_names names
  • Server identity and state: get_server_identity (MMS Identify) and get_server_status (MMS Status)
  • Schema introspection: get_variable_specification(ref, fc) (recursive MMS type tree) and get_device_model() (per-LD named-variable index)
  • Dataset admin: create_data_set, delete_data_set, get_data_set_values, set_data_set_values
  • Connection control: disconnect (graceful) and abort (rude close — drop TCP without sending MMS Conclude)
  • URCB / BRCB reporting: get_rcb_values, set_rcb_values, install_report_handler, poll_reports, background ReportDispatcher; each report says which members it carries (included) and which segment of a segmented report it is
  • Log service: query_journal(log_ref, JournalQuery) for one ReadJournal request with any selection, query_journal_all to read every page, and the query_journal_by_time / query_journal_after_entry shorthands; a journal is named by its LogRef
  • GOOSE control block administration over MMS: get_gocb_values and set_gocb_values (GOOSE frames themselves stay out of scope)
  • SCL / ICD / CID document parser: load_scl(path) / parse_scl(xml) → Scl handle exposing IED inventory, the full document as a nested dict, and a canonical text summary per IED
  • Server hosting: IedServer.from_scl(path, ied_name=...) instantiates an MMS server from an SCL document, or IedServer.from_model_spec(spec) from a declarative Python dict when the IED is generated in code rather than authored as XML. Bind, configure (vendor / model name / max connections / association timeouts / run-time data set limits), enter via async with, push value updates with typed update_* methods and whole arrays with update_array, intercept reads / writes with on_read / on_write callbacks (optionally with the request context), serve control commands (SBO / direct, normal / enhanced) with on_control — operate and wait callbacks may be either sync or async — register every data set, report, GOOSE and log control block and control object the model declares with register_from_model(), or expose URCB / BRCB reporting via add_dataset / register_urcb / register_brcb and Log Control Blocks via register_log_control (in-memory journal recorded from the data set members, ReadJournal over MMS, log_value for further entries), wire Setting Group callbacks per LD with register_setting_group_handler + force_active_setting_group and read or replace the values of each group; choose the edition (set_edition) and the functional constraints clients may write (set_write_access_policy); group updates with with server.batch(): so they report and log as one batch; terminate TLS at the server with with_tls() (same IEC 62351-3 profile as the client, plus client-cert pinning)
  • Control: select, select_with_value, operate, cancel across the four IEC 61850 control models (direct-normal / direct-enhanced / sbo-normal / sbo-enhanced), each returning a ControlOutcome that carries the add cause and the LastApplError the server reported
  • Typed exception hierarchy: IedError, IedConnectionError, IedSessionRefusedError, IedTlsError, IedTimeoutError, IedDataAccessError, IedServiceError, IedControlError, IedServerError; each carries attributes naming the cause
  • SNTP / NTP client: query_sntp(addr, timeout_s) returns an SntpResponse with server time, clock offset, and round-trip estimate computed per RFC 4330 §5; addr is an IP address and port such as "192.0.2.10:123" or "[2001:db8::1]:123"
  • Type stubs (_native.pyi) and a py.typed marker for full mypy / pyright coverage of the public surface
  • Cookbook of runnable examples under examples/ (quickstart client, server from SCL, server from model dict, BRCB reporting, control SBO, SNTP query)

Install

pip install iec61850

Requires Python 3.11+. Wheels are published for Windows x86_64 and Linux x86_64 (manylinux 2014); macOS arm64 is built and tested in CI but not yet published. They are abi3 wheels: one build serves every supported Python 3.11 or later.

Building from source

Only needed to work on the package itself; installing from PyPI needs no Rust toolchain. You will need a stable Rust toolchain (edition 2021, MSRV 1.88) and uv.

The Rust side is not vendored. Cargo.toml takes each crate from the implementation repository at the release tag this version tracks:

iec61850-client = { git = "https://github.com/csp0924/iec61850-rust", tag = "v0.4.0", features = ["tls"] }

With that tag published, a build is just:

uv sync                       # dev environment, including maturin and pytest
uv run maturin develop --release
uv run pytest -q

Building against a local checkout

To build against an unreleased iec61850-rust — a tag not yet published, or changes made to both repositories together — clone it next to this one so the two share a parent directory:

<parent>/
  iec61850-rust/
  iec61850-python/

Then create .cargo/config.toml, which is git-ignored precisely so this override never ships:

[patch."https://github.com/csp0924/iec61850-rust"]
iec61850-client = { path = "../iec61850-rust/crates/iec61850-client" }
iec61850-model  = { path = "../iec61850-rust/crates/iec61850-model" }
iec61850-mms    = { path = "../iec61850-rust/crates/iec61850-mms" }
iec61850-scl    = { path = "../iec61850-rust/crates/iec61850-scl" }
iec61850-server = { path = "../iec61850-rust/crates/iec61850-server" }
iec61850-sntp   = { path = "../iec61850-rust/crates/iec61850-sntp" }
iec61850-tls    = { path = "../iec61850-rust/crates/iec61850-tls" }

A patch redirects a package, but Cargo still loads the git source it is patching before applying the patch. So while the tag is not published, that config alone is not enough — resolution fails with:

failed to load source for dependency `iec61850-client`
  Unable to update https://github.com/csp0924/iec61850-rust?tag=v0.4.0

Seed a lock file once and the patch takes over. Cargo's git backend needs an absolute URL here, so derive one rather than hard-coding it. From the repository root, with the sibling checkout in place:

# Absolute path to the sibling checkout. `pwd -W` is the Git-for-Windows
# spelling that yields `D:/...`; plain `pwd` covers Linux and macOS.
RUST_REPO=$(cd ../iec61850-rust && { pwd -W 2>/dev/null || pwd; })

# 1. Point the manifest at that checkout, just long enough to resolve.
sed -i "s|https://github.com/csp0924/iec61850-rust\", tag = \"v0.4.0|file://${RUST_REPO}\", branch = \"main|g" Cargo.toml
cargo generate-lockfile

# 2. Restore the manifest and relabel the source lines the lock recorded.
#    Cargo canonicalises the URL it stores, so match on the branch suffix
#    rather than on the exact spelling passed in above.
git checkout Cargo.toml
sed -i -E "s|git\+file://[^\"]*\?branch=main|git+https://github.com/csp0924/iec61850-rust?tag=v0.4.0|g" Cargo.lock

Cargo.lock is git-ignored for the same reason: it pins a revision the published repository does not carry yet. After this, cargo metadata resolves offline and reports the patched packages coming from ../iec61850-rust/crates/*, and uv run maturin develop --release builds against your working tree — edits on the Rust side are picked up without a commit.

Once the tag Cargo.toml names is published, delete .cargo/config.toml and Cargo.lock and build normally; none of this is needed any more.

Conformance (PICS)

ACSI service support per IEC 61850-7-2 Edition 2; the section numbers below follow that edition.

  • Py-C / Py-S — exposed through this Python package (client / server).
  • Rust-C / Rust-S — supported somewhere in the upstream iec61850-rust workspace.

Legend: yes supported; — not yet implemented; partial a stated subset (see the footnote); no, by design deliberately not in Python (use the named Rust crate instead); n/a not applicable; (n) footnote. The Rust columns follow the upstream conformance statement, docs/PICS.md, which carries the full per-service detail.

Application Association (§8)

Service Py-C Py-S Rust-C Rust-S
Associate (Two-Party, MMS/TCP) yes yes yes yes
Abort (graceful Conclude) yes yes yes yes
Abort (rude — TCP drop) yes yes yes yes
Release yes yes yes yes
Configurable ISO addressing yes — yes —
TLS 1.2 / 1.3 (IEC 62351-3) yes (1) yes (1) yes yes
Mutual TLS / pinned peer / CRL yes yes yes yes
Authentication (ACSE password) yes (15) yes (15) yes yes
Association gating (AP-title) — yes (15) — yes
  1. Includes 62351-3 cipher whitelist, verify_hostname and time_validation knobs, version pinning, and known-peer profile; the certificate chain is always validated. A failed client handshake raises IedTlsError with its kind. Backed by iec61850-tls.

  2. The client sends IsoConnectionParameters(password=...) as the ACSE password mechanism; a refusal naming the calling identity or the credentials raises IedAuthenticationError. The server decides on each association through IedServer.set_authenticator. The IEC 62351-4 certificate mechanism is not implemented; peer authentication by certificate is done by TLS.

Server class (§7)

Service Py-C Py-S Rust-C Rust-S
GetServerDirectory yes yes yes yes
GetServerCapabilities (Ed.2) — — — —
MMS Identify yes yes yes yes
MMS Status yes yes yes yes

The hosted server answers Identify with the vendor, model_name and revision it is configured with.

Logical Device class (§9)

Service Py-C Py-S Rust-C Rust-S
GetLogicalDeviceDirectory yes yes yes yes

Logical Node class (§10)

Service Py-C Py-S Rust-C Rust-S
GetLogicalNodeDirectory yes yes yes yes
GetAllDataValues — — — yes

Data class (§11)

Service Py-C Py-S Rust-C Rust-S
GetDataValues yes yes (2) yes yes
SetDataValues yes yes (2) yes yes
GetDataDirectory yes yes yes yes
GetDataDefinition / GetVariableSpec yes yes yes yes
Array element access (read / write) yes yes yes yes
  1. Server applies the write access policy (default SP | SV | SE; set_write_access_policy also opens DC, CF and BL, before start() or while running) and any registered on_read / on_write callbacks, which are asked for reads and writes above and below their own path and can receive the request context. update_array updates a whole array attribute as one batch.

GetDataValues covers both the single read (read) and the batched form (read_multiple), which carries any set of references in one MMS Read.

Data Set class (§13)

Service Py-C Py-S Rust-C Rust-S
GetDataSetValues yes yes yes yes
SetDataSetValues yes yes yes yes
CreateDataSet (dynamic) yes yes yes yes
DeleteDataSet yes yes yes yes
GetDataSetDirectory (members) yes yes yes yes
List data set names (GetLogicalNodeDirectory DS) yes yes yes yes
Static (SCL-defined) datasets yes yes (3) yes yes
  1. Server registers static datasets through add_dataset() or, for every data set the model declares, register_from_model(); either bound to a control block or exposed standalone for GetDataSetValues.

Substitution (§5.3.3)

Service Py-C Py-S Rust-C Rust-S
Set substituted value (FC=SV writes) partial (12) partial (12) partial (12) partial (12)
Dedicated Substitution service API — — — —
  1. The SV functional constraint is writable by the default write access policy, and MV, CMV and SAV carry the substitution attributes, but a read does not itself switch to the substituted value.

Setting Group Control Block — SGCB (§16)

Service Py-C Py-S Rust-C Rust-S
SelectActiveSG / SelectEditSG partial (6) yes (6) partial (6) yes
GetSGCBValues / SetSGCBValues partial (6) yes (6) partial (6) yes
ConfirmEditSGValues partial (6) yes (6) partial (6) yes
Setting access (FC=SG / FC=SE writes) yes yes yes yes
Values of every setting group n/a yes n/a yes
  1. Server-side SGCB is declared via SCL <SettingControl numOfSGs="N"/> on LN0; runtime ActSG / EditSG / ConfirmEditSG state machine plus reservation timeout are owned by the server, which also holds the values of every group: SelectActiveSG loads the group into the FC=SG attributes and ConfirmEditSGValues stores the FC=SE buffer into it. Python applications install per-LD callbacks (on_act_sg / on_edit_sg / on_confirm) through register_setting_group_handler(), can force_active_setting_group() on startup, and read or replace the value a group holds with get_setting_group_value() / set_setting_group_value(). Clients, in Python and in Rust alike, drive SGCB through the generic write API on the special MMS path (e.g. write("IED1LD0/LLN0.SGCB.ActSG", FC.SP, {"type": "uint", "value": 2})); neither has a dedicated setting-group API.

Reporting — URCB / BRCB (§17.2)

Service Py-C Py-S Rust-C Rust-S
URCB — GetURCBValues / SetURCBValues yes yes yes yes
URCB — Report (TrgOps, OptFlds, BufTm, IntgPd) yes yes yes yes
URCB — General Interrogation yes yes yes yes
BRCB — GetBRCBValues / SetBRCBValues / Report yes yes (4) yes yes
Segmentation (SubSeqNum / MoreFollows) yes yes yes yes
Per-member inclusion of a report yes yes yes yes
Instances from the model n/a yes n/a yes
Background report dispatcher yes n/a yes n/a
  1. Server BRCB hosting via register_brcb() or register_from_model() with in-memory ring buffer (entry-count semantics), EntryID resync, and the update_* trigger path. The first report after each enable carries BufOvfl set.

Logging — LCB / Log (§17.3)

Service Py-C Py-S Rust-C Rust-S
Log (recording on trigger) n/a yes (5) n/a yes
ReadJournal (every optional field) yes yes (5) yes yes
ReadJournal pagination (read to end) yes yes yes yes
LCB — GetLCBValues — yes — yes
LCB — SetLCBValues — — — —
GetLogStatusValues — yes — yes
QueryLogByTime / QueryLogAfter yes yes (5) yes yes
Log purging — — — —
  1. Server LCB hosting via register_log_control() or register_from_model() with an in-memory journal backend (optionally capacity-bounded, evicts oldest on overflow). The server writes an entry whenever a member of the block's data set changes value or quality or is updated, as its TrgOps enable, and one entry holding the whole data set every IntgPd; general interrogation writes none. log_value adds entries of the application's own. LogEna toggles at runtime via set_log_ena. A journal is named by the block's LogRef.

Generic Substation Event — GOOSE / GSE (§18)

Service Py-C Py-S Rust-C Rust-S
GoCB — Get / Set values partial (14) partial (14) partial (14) partial (14)
GOOSE publish no, by design (7) no, by design (7) n/a yes
GOOSE subscribe no, by design (7) no, by design (7) yes n/a
  1. By design, not on the Python roadmap. GOOSE is a hard-real-time L2 protocol (IEC 61850-8-1; T1 retransmission floor = 4 ms; protection schemes require deterministic dispatch). Python's GIL + non-deterministic GC make it unsuitable for the GOOSE hot path. Use iec61850-goose directly — it provides GoosePublisher (frame template + retransmission state machine), GooseSubscriber (smpCnt continuity + Q4), and a typestate GooseReceiver.
  2. MMS administration of a GOOSE control block, which involves no Ethernet frame. The client reads the nine components with get_gocb_values and writes GoEna, GoID and DatSet with set_gocb_values, one attribute per request. The hosted server serves the GoCBs register_from_model() registers; GoID and DatSet are writable while GoEna is false, and read-only under set_edition("ed2.1"). The other six components are read-only, and FixedOffs always reads false.

Transmission of Sampled Values — SVCB (§19) (8)

Service Py-C Py-S Rust-C Rust-S
MSVCB / SVCB — Get / Set values no, by design no, by design — —
Sampled-value publish no, by design no, by design n/a yes
Sampled-value subscribe no, by design no, by design yes n/a
  1. By design, not on the Python roadmap. SV runs at 4 kHz with a p99 jitter budget < 200 us (protection profile 256 samples/cycle is even tighter). This is achievable on Linux with SCHED_FIFO + raw socket — not from a GIL-bound runtime. Use iec61850-sv directly — it provides SvPublisher with frame-template + hot-path setters, a Linux publish_thread (clock_nanosleep-based), and SvSubscriber with smpCnt continuity tracking.

Control (§20)

Service Py-C Py-S Rust-C Rust-S
status-only yes yes yes yes
direct-normal yes yes yes yes
sbo-normal yes yes yes yes
direct-enhanced yes yes yes yes
sbo-enhanced yes yes yes yes
Select / SelectWithValue yes yes yes yes
Operate / Cancel yes yes yes yes
Test mode, ctlNum, origin yes yes yes yes
TimeActivatedOperate — — — — (13)
AddCause / LastApplError yes yes yes yes
Control settings from the model n/a yes n/a yes
Operate timeout n/a yes n/a yes
  1. The Rust server refuses an Oper carrying an operTm other than 0 with the add cause Not-supported.

A ctlModel, sboTimeout, sboClass or operTimeout the model declares takes precedence over the arguments of on_control; register_from_model() registers every controllable data object of the model.

Time and Time Synchronization (§21)

Service Py-C Py-S Rust-C Rust-S
UTC time read (Timestamp DA) yes yes yes yes
Time-quality flags on update n/a yes n/a yes
SNTP / NTP responder — — n/a yes (9)
SNTP / NTP client yes (10) n/a yes (10) n/a
  1. SNTPv4 unicast server in iec61850-sntp (mode 3 → mode 4 reply). Not exposed from Python by design: answering time requests with useful accuracy needs the host clock, timestamping close to the socket and a UDP port of its own, which an IED's operating system time service provides; the package covers the client side (footnote 10).
  2. SNTPv4 unicast client. From Python use iec61850.query_sntp(addr, timeout_s); from Rust use iec61850_sntp::SntpClient. Single-sample offset / round-trip via RFC 4330 §5 four-timestamp formula. addr is an IP address with its port ("192.0.2.10:123"); a host name is not resolved and raises ValueError, so resolve it first, for example with loop.getaddrinfo.

File Transfer (§23)

Service Py-C Py-S Rust-C Rust-S
GetFile / SetFile / DeleteFile — (11) — (11) — (11) — (11)
GetFileAttributeValues — (11) — (11) — (11) — (11)
GetServerDirectory(FILE) — (11) — (11) — (11) — (11)
  1. File services are deferred until the upstream Rust workspace ships PDU encode / decode, a client API, and server-side dispatch. The Python package will pick them up once that Rust client surface lands.

Tooling (out-of-band)

Capability Python Rust
SCL / ICD / CID parser yes yes
Two-stage SCL pipeline (XML + cross-element resolution) yes yes
Typed-spec introspection (TypeSpec) yes yes
Code-driven IedModel construction yes yes
Async SNTP / NTP client yes yes

Not exposed from Python

Beyond GOOSE and Sampled Values frames (footnotes 7 and 8), a few parts of the Rust API stay out of this package on purpose:

  • Raw Ethernet access and the choice of an L2 backend: they need platform privileges and driver-level setup.
  • IedServer::tick_log_integrity: it takes a std::time::Instant, which Python cannot supply; the server drives integrity logging from its own timer.
  • IedServer::lock_data_model: its guard holds the data-model lock across calls, which deadlocks easily from Python; batch() covers grouped updates.
  • BlockingMmsClient: the package is async throughout.
  • Building GOOSE or Sampled Values publisher settings from the model (CommParameters::from_address, SvPublisherBuilder::with_address): they configure frame publishing, which stays out of the package (footnotes 7 and 8); gse_address and smv_address read the addresses.
  • The internal registries, the reporting engine and the storage traits: they bypass the update_* path; the server methods above cover what they do.
  • Request blocking on a server connection (block_requests / set_block_requests): the server uses it for maintenance and while it aborts a connection; aborting the connection drops a client outright.
  • IedServer::set_ignore_read_access: it bypasses every read handler at once; register or omit on_read handlers instead.
  • IedConnection::get_logical_node_variables: it returns the raw MMS variable names of one logical node, which get_device_model() already lists for the whole device.
  • IedConnection::get_data_directory_by_fc: get_variable_specification with that functional constraint names the same children, with their types.
  • ControlObjectClient::wait_command_termination: operate() under an enhanced-security model already waits for the CommandTermination and reports its outcome.
  • The options of IedServer::register_from_model_with (log storage factory, GOOSE destination factory, wall clock): they supply Rust objects the server calls from its own threads on every log entry and publication, which from Python would take the GIL on those paths; register_from_model() uses in-memory logs and the system clock, and register_log_control configures one log explicitly.
  • DataAttribute::assign: it writes the model without raising reports or log entries; update_*, update_array and batch() do the same with triggers.
  • The SNTP server (footnote 9).
  • TlsStream::negotiated_cipher_suite: the client keeps its TLS stream inside the connection and exposes none, so there is nothing to ask; the suite is always one of the fixed list under TLS.
  • Persistent report buffers (the SQLite backend): it needs the sqlite-backend feature, which the wheels do not build, plus a database path and a lifetime the application manages; register_brcb buffers in memory.
  • The TLS 1.3 session ticket count of a hosted server (tls13_session_tickets): it stays at 0, as some TLS 1.3 clients close the connection when a ticket arrives; TLS 1.2 session resumption works.
  • The IEC 62351-3 TLS event handler (with_event_handler): the TLS layer calls it synchronously on its own threads for every event, so a Python callback would take the GIL inside each handshake; handshake failures surface as IedTlsError on the client.

Quick start

import asyncio
import iec61850

async def main():
    conn = await iec61850.IedConnection.connect("127.0.0.1:102", timeout_ms=5000)
    try:
        status = await conn.read_int32("DemoIEDLD0/LLN0.Mod.stVal", iec61850.FC.ST)
        vendor = await conn.read_string("DemoIEDLD0/LLN0.NamPlt.vendor", iec61850.FC.DC)
        quality = await conn.read_quality("DemoIEDLD0/GGIO1.Ind1.q", iec61850.FC.ST)
        print(status, vendor, quality.validity)
    finally:
        await conn.disconnect()

asyncio.run(main())

TLS

ca_pem = open("ca.pem", "rb").read()
tls = iec61850.TlsConfig(ca_pem=ca_pem)

conn = await iec61850.IedConnection.connect_tls(
    "ied.example.com:3782",
    tls,
    server_name="ied.example.com",
    timeout_ms=5000,
)

Mutual TLS adds a client cert and key:

tls = iec61850.TlsConfig(
    ca_pem=open("ca.pem", "rb").read(),
    client_cert_pem=open("client.crt", "rb").read(),
    client_key_pem=open("client.key", "rb").read(),
)

The certificate chain is always validated against ca_pem; there is no switch to turn that off. Defaults: TLS 1.2-1.3, IEC 62351-3 cipher whitelist, time validation on, session resumption on. Set verify_hostname=False on TlsConfig to skip SNI / SAN hostname matching for closed-network commissioning, or time_validation=False to accept a certificate outside its validity period (chain validation still applies).

The cipher suites are fixed to the IEC 62351-3 list the underlying TLS library implements, on the client and on the hosted server alike, and no argument adds or removes one:

Version Cipher suites
TLS 1.2 TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384
TLS 1.3 TLS13_AES_128_GCM_SHA256, TLS13_AES_256_GCM_SHA384

The TLS_DHE_RSA_* suites IEC 62351-3 also permits are not offered, so a peer that supports only those fails the handshake.

Pinned peers, CRL, version pinning

tls = iec61850.TlsConfig(
    ca_pem=open("ca.pem", "rb").read(),
    # Restrict accepted server certificates to a fixed allow-list
    # (IEC 62351-3 known-peer profile): the server's leaf certificate must
    # equal one of these, compared as whole DER certificates.
    allow_only_known_peers=True,
    known_peer_pems=(open("ied1.crt", "rb").read(),),
    # Pin a single TLS version.
    min_version=iec61850.TlsVersion.TLS_1_3,
    max_version=iec61850.TlsVersion.TLS_1_3,
    # Revocation checks.
    crl_pems=(open("ca.crl.pem", "rb").read(),),
)

Handshake failures

A handshake that fails while the connection is being established raises IedTlsError, a subclass of IedConnectionError. Its kind says why: "verification" (the peer certificate was not accepted), "alert_received" (the peer refused, for example the client certificate), "version_unsupported", "cipher_unsupported", "timeout", "io" or "other"; message holds the TLS error text.

try:
    conn = await iec61850.IedConnection.connect_tls("10.0.0.1:3782", tls)
except iec61850.IedTlsError as e:
    print("TLS refused:", e.kind, e.message)

High-level client

Iec61850Client wraps IedConnection as an async context manager and optionally runs a background report dispatcher:

cfg = iec61850.Iec61850ClientConfig(
    address="ied.example.com",
    port=102,
    timeout_ms=5000,
    # Tuning that flows down into the underlying MMS client.
    request_timeout_ms=3000,
    max_outstanding=4,
    local_max_pdu_size=16384,
    # Background dispatcher; None to disable.
    report_dispatcher_interval_ms=100,
)

async with iec61850.Iec61850Client(cfg) as cli:
    val = await cli.connection.read_float(
        "DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX
    )

For TLS, pass a TlsConfig on the config and (optionally) override the SNI:

cfg = iec61850.Iec61850ClientConfig(
    address="10.0.0.1",            # network address
    port=3782,
    tls=iec61850.TlsConfig(ca_pem=ca_pem),
    tls_server_name="ied.example.com",  # SNI; defaults to `address`
)

The same request_timeout_ms / max_outstanding / local_max_pdu_size keyword arguments are also accepted on IedConnection.connect and IedConnection.connect_tls for callers that prefer to manage the connection lifecycle directly. max_outstanding is limited to 65535. max_name_list_names (on both, and on Iec61850ClientConfig) caps the names one directory walk collects; past it the walk fails with IedServiceError whose reason is "name-list-limit".

Generic read / write

# Native Python types: scalars surface as bool / int / float / str;
# bytes-like kinds as bytes; arrays and structures as list.
value = await conn.read("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX)

# A remote Write is accepted for FC=SP, SV, and SE by default; the
# server-side write access policy decides the rest.
await conn.write(
    "DemoIEDLD0/GGIO1.SetPt1.setVal", iec61850.FC.SP, 42
)

A value no Python type selects is written as a tagged dict, the form IedServer.from_model_spec takes. A BIT STRING carries its octets first bit first, in the most significant bit of the first octet, and the number of unused trailing bits in the last octet:

# Dbpos "on" (binary 10): one octet, six unused trailing bits.
await conn.write(
    "LD/XCBR1.PosSet.setVal",
    iec61850.FC.SP,
    {"type": "bit_string", "padding": 6, "data": b"\x80"},
)

# The typed pair does the same and keeps the padding on the way back.
await conn.write_bit_string("LD/XCBR1.PosSet.setVal", iec61850.FC.SP, b"\x80", 6)
data, padding = await conn.read_bit_string("LD/XCBR1.Pos.stVal", iec61850.FC.ST)

A structure is written as {"type": "structure", "value": [...]}: its components in order, each a plain value or a tagged dict, so structures nest. A structure read back, or handed to a server callback, is a list of its components.

# AnalogueValue with its f component only.
await conn.write(
    "LD/GGIO1.AnOut1.setMag",
    iec61850.FC.SP,
    {"type": "structure", "value": [{"type": "float32", "value": 1.5}]},
)

Array elements and sub-components are addressed with keyword arguments:

# Reads the third element of an array DA.
elem = await conn.read("LD/LN.Arr", iec61850.FC.ST, array_index=2)

# Reads `stVal` inside the third element.
sub = await conn.read(
    "LD/LN.Arr", iec61850.FC.ST, array_index=2, component="stVal"
)

Schema introspection

# Per-variable MMS TypeSpecification, returned as a nested dict.
ts = await conn.get_variable_specification(
    "DemoIEDLD0/LLN0.Mod", iec61850.FC.ST
)
# ts == {"kind": "structure", "components": [
#   {"name": "stVal", "type": {"kind": "integer", "width_bits": 32}},
#   {"name": "q",     "type": {"kind": "bit_string", "bits": 13}},
#   ...
# ]}

# Whole device-model index — list of logical devices with their MMS
# NamedVariable names. First call fetches; subsequent calls hit a cache.
model = await conn.get_device_model()
for ld in model["logical_devices"]:
    print(ld["name"], len(ld["variables"]))

# Force a re-fetch if the server model may have changed.
fresh = await conn.get_device_model(refresh=True)

Every type-spec node carries a "kind" discriminator. Scalar kinds add payload fields appropriate for the type (width_bits, format_width / exponent_width, max_chars, bits, ...). "array" adds element_count plus a recursive element_type. "structure" adds components — a list of {"name", "type"} entries. "unknown" surfaces the raw ASN.1 tag for forward compatibility.

Datasets

await conn.create_data_set(
    "DemoIEDLD0/LLN0.ds1",
    [
        iec61850.DataSetMember("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX),
        iec61850.DataSetMember("DemoIEDLD0/GGIO1.Ind1.stVal", iec61850.FC.ST),
    ],
)

values = await conn.get_data_set_values("DemoIEDLD0/LLN0.ds1")
# values is a list ordered to match the data set members.

await conn.set_data_set_values("DemoIEDLD0/LLN0.ds1", [3.14, True])

deleted = await conn.delete_data_set("DemoIEDLD0/LLN0.ds1")

DataSetMember accepts optional array_index / component to target an array element or a sub-component (component requires array_index); the facade composes the alternate-access reference for you.

get_data_set_values and set_data_set_values raise IedDataAccessError when any single entry's access or write fails on the server, with the entry index in the error message.

What a data set holds

directory = await conn.get_data_set_directory("DemoIEDLD0/LLN0.dsStatus")

directory.deletable          # False for an SCL-declared set, True for a
                             # set built with create_data_set()
for member in directory.members:
    print(member.fc.value, member.object_ref)

Members come back in the order the server holds them, which is the order get_data_set_values returns its entries in, and in the reference form create_data_set accepts — so a directory read clones a data set:

await conn.create_data_set("DemoIEDLD0/LLN0.ds_clone", directory.members)

Listing the data set names of a logical node is a different service: get_logical_node_directory(ln_ref, iec61850.AcsiClass.DATASET).

Reading several objects in one round trip

values = await conn.read_multiple(
    [
        ("DemoIEDLD0/GGIO1.Ind1.stVal", iec61850.FC.ST),
        ("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX),
    ],
)

The result follows the request order and has the same length. No named variable list has to exist on the server, so any set of attributes can be polled with a single MMS Read.

Per-entry failures

By default one failing entry raises IedDataAccessError. Pass strict=False to read_multiple or get_data_set_values to keep the successful values and receive a DataAccessFailure in the failing position:

values = await conn.read_multiple(targets, strict=False)
for target, value in zip(targets, values, strict=True):
    if isinstance(value, iec61850.DataAccessFailure):
        print(f"{target[0]} unavailable: {value.error}")

DataAccessFailure.error is the symbolic MMS DataAccessError name (for example "ObjectNonExistent") and .code the value carried on the wire.

Connection control

# Normal close — MMS Conclude exchange, then TCP shutdown.
await conn.disconnect()

# Rude close — drop the TCP socket without negotiation. Use when the peer
# stops responding or a normal disconnect would block.
await conn.abort()

Server identity and status

identity = await conn.get_server_identity()      # MMS Identify
print(identity.vendor, identity.model, identity.revision)

status = await conn.get_server_status()          # MMS Status
print(status.logical, status.physical)           # e.g. "state-changes-allowed", "operational"

ServerIdentity.abstract_syntaxes lists the abstract syntaxes the server announces as dotted OIDs. ServerStatus names a value outside the standard set "other" and keeps the wire value in logical_code / physical_code; local_detail is the optional detail bit string as a tuple of bool. get_server_status(extended_derivation=True) asks the server to derive the state from a fresh self-check.

ISO addressing

The association a client opens carries the transport, session and presentation selectors and the ACSE application-entity titles. The default selectors are the values IEC 61850-8-1 specifies for an MMS association, and the default AP-titles and AE-qualifier are the values IEDs customarily expect, which the standard leaves to the configuration; pass an IsoConnectionParameters when a device expects something else.

Field Default Limit
local_t_sel b"\x00\x01" 4 bytes
remote_t_sel b"\x00\x01" 4 bytes
local_s_sel b"\x00\x01" 16 bytes
remote_s_sel b"\x00\x01" 16 bytes
local_p_sel b"\x00\x00\x00\x01" 16 bytes
remote_p_sel b"\x00\x00\x00\x01" 16 bytes
local_ap_title "1.1.1.999" dotted OID
remote_ap_title "1.1.1.999.1" dotted OID
local_ae_qualifier 12 signed 32-bit
remote_ae_qualifier 12 signed 32-bit
iso = iec61850.IsoConnectionParameters(
    remote_p_sel=b"\x00\x00\x00\x02",
    remote_ap_title="1.3.9999.13",
)

conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)

# The same parameter is accepted by connect_tls() and by
# Iec61850ClientConfig(iso=...).

An over-long selector or a malformed AP-title raises ValueError when the parameters are built, before any socket is opened. An AP-title of None leaves that field out of the ACSE AARQ.

password sends the ACSE password mechanism (a str goes out as its UTF-8 octets). It travels in clear unless the association runs over TLS, and the dataclass repr leaves it out. A server that refuses the calling identity or the credentials raises IedAuthenticationError, a subclass of IedConnectionError, whose diagnostic and diagnostic_name give the acse-service-user diagnostic of the refusal:

iso = iec61850.IsoConnectionParameters(password="s3cret")
try:
    conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)
except iec61850.IedAuthenticationError as e:
    print(e.diagnostic, e.diagnostic_name)   # 13 authentication-failure

Releases before 0.14.0 always offered empty presentation selectors and no AP-title or AE-qualifier at all. A peer configured to expect that addressing can be given it back:

iso = iec61850.IsoConnectionParameters(
    local_p_sel=b"",
    remote_p_sel=b"",
    local_ap_title=None,
    remote_ap_title=None,
    local_ae_qualifier=None,
    remote_ae_qualifier=None,
)

A peer that does not recognise the addressing it is offered answers the session CONNECT with a REFUSE SPDU, which surfaces as IedSessionRefusedError:

try:
    conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)
except iec61850.IedSessionRefusedError as e:
    # ISO 8327-1 reason code, transport-disconnect parameter, and the
    # presentation provider-reason; each is None when the refusal omits it.
    print(e.reason_code, e.transport_disconnect, e.provider_reason)

Log service

A journal is named by the LogRef of its log control block, "<domain>/<LN>$<name>", not by the control block's own reference.

LOG_REF = "IED1LD0/LLN0$EventLog"

# One ReadJournal request. ``more_follows`` signals that the server stopped
# at the PDU size and the caller should resume.
query = iec61850.JournalQuery.by_time(start_ms, end_ms)
entries, more = await conn.query_journal(LOG_REF, query)
for e in entries:
    print(e.time_ms, e.entry_id.hex(), len(e.variables))

# Every entry the selection covers, following ``more_follows``.
entries = await conn.query_journal_all(LOG_REF, query)

# Resume after the last seen entry.
cursor = entries[-1]
later = await conn.query_journal_all(
    LOG_REF, iec61850.JournalQuery.starting_after(cursor.time_ms, cursor.entry_id)
)

JournalQuery carries every selection ReadJournal defines: a start (start_time_ms or start_entry), a stop (end_time_ms or max_entries), the variables to return, and after_entry as a (time_ms, entry_id) pair; it raises ValueError for a combination the service does not allow. query_journal_all keeps the selection on every continuation, returns each entry once, none past end_time_ms and no more than max_entries, and raises IedServiceError with reason == "journal-not-advancing" when a server reports more entries but sends none it has not sent before. query_journal_by_time(log_ref, start_ms, end_ms) and query_journal_after_entry(log_ref, time_ms, entry_id) remain as shorthands for one request.

JournalEntry.variables is a tuple of JournalEntryVariable(data_ref, value, reason_code). Values follow the same conversion rules as IedConnection.read — scalars surface natively; bytes-like kinds (BIT_STRING / OCTET_STRING / UTC_TIME / BINARY_TIME) as bytes; composites as list.

Reporting

def on_report(report: iec61850.ClientReport) -> None:
    print(report.rcb_reference, len(report.entries))

rcb = await conn.get_rcb_values("DemoIEDLD0/LLN0$RP$urcbMeas")
rcb.resv = True
rcb.rpt_ena = True
await conn.set_rcb_values(rcb, iec61850.RcbWriteMask.fields("resv", "rpt_ena"))
await conn.install_report_handler(rcb.object_reference, on_report)

dispatcher = conn.spawn_report_dispatcher(interval_ms=100)
try:
    await asyncio.sleep(10)
finally:
    await dispatcher.aclose()

ClientReport.entries holds one entry per data set member, keeping the last value an earlier report carried for a member this one omits; ClientReport.included holds one flag per member, set for the members this report carries:

def on_report(report: iec61850.ClientReport) -> None:
    for entry, carried in zip(report.entries, report.included, strict=True):
        if carried:
            print(entry.ref, entry.value, entry.reason)

A report larger than the PDU size the association negotiated arrives in segments, each delivered to the handler as its own ClientReport with the same sequence_number: sub_seq_num counts them from zero, more_segments_follow is true on every segment but the last, and included marks only the members of that segment. sub_seq_num is None for an unsegmented report. The client does not reassemble segments.

Against a 0.4.0 server (including the one this package hosts):

  • RcbHandle.dataset and ClientReport.dataset_name read back with the logical device, "<LD>/<LN>$<name>"; a write may omit it.
  • Enabling an unreserved URCB reserves it for the writer; writing any other attribute of an unreserved URCB does not reserve it. It stays reserved after rpt_ena=False until the holder writes resv=False or its association ends. resv cannot be written while the URCB is enabled.
  • gi=True on a disabled control block fails with TemporarilyUnavailable.
  • Writing rpt_id, dataset, opt_flds, buf_time, trigger_options, integrity_period, purge_buf, entry_id or resv_tms of an enabled BRCB (as named in RcbWriteMask) fails with TemporarilyUnavailable. conf_rev counts DatSet changes only, and after a purge entry_id reads all zeros until the next report is sent.
  • The first report after every enable of a BRCB carries buffer_overflow set, whichever EntryID the client resynchronised from.
  • A member reports only the triggers its attribute declares (dchg, qchg, dupd in the SCL); an update to the value an attribute already holds sends no data change, only a data update where dupd is declared.

Control

spc = conn.create_control_object(
    "IED1LD0/GGIO1.SPCSO1",
    iec61850.ControlModel.SBO_ENHANCED,
)
spc.set_origin(iec61850.OriginValue(or_cat=3, or_ident=b"py-client"))

if await spc.select_with_value(True):
    outcome = await spc.operate(True)
    if not outcome:
        print("operate failed:", outcome.add_cause)
        if outcome.last_appl_error is not None:
            print(outcome.last_appl_error.error, outcome.last_appl_error.ctl_num)

select, select_with_value, operate and cancel all return a ControlOutcome, which is truthy exactly when the command succeeded. add_cause is the ControlAddCause of a refusal and last_appl_error the LastApplError the server reported with it (ctl_obj, error, or_cat, or_ident, ctl_num, add_cause), or None when it sent none. The enhanced-security models always report one; a normal-security server may not, and a refused normal-security select (a read of SBO) carries no cause at all, so it reads unknown. Add cause 24 is ControlAddCause.BLOCKED_BY_COMMAND ("blocked-by-command"); ABORTION_BY_COMMAND remains an alias.

The value given to select_with_value, operate and cancel has to encode as the ctlVal type of the object's common data class (IEC 61850-7-3 §7.5): a bool is sent as BOOLEAN, an int as a signed INTEGER and a float as a single FLOAT32, and a tagged dict, the form write takes, as the type it names.

CDC ctlVal Python value
SPC, DPC BOOLEAN bool
INC INT32 int
ENC ENUMERATED int
ISC INT8 int
BSC, BAC CODED ENUM (stop, lower, higher) {"type": "bit_string", "padding": 6, "data": b"\x40"} (lower)
APC AnalogueValue (a structure) {"type": "structure", "value": [{"type": "float32", "value": 1.5}]}

A double point control takes a bool, like a single point one; an int is sent as an INTEGER, which a server that checks the type refuses:

dpc = conn.create_control_object(
    "IED1LD0/XCBR1.Pos", iec61850.ControlModel.SBO_ENHANCED
)
if await dpc.select_with_value(True):    # True closes, False opens
    outcome = await dpc.operate(True)

An APC's ctlVal is an AnalogueValue structure; send it as a tagged structure whose elements follow the server's declaration, here f alone. A bare float goes out as a lone FLOAT32, which a server that checks the type refuses:

apc = conn.create_control_object(
    "IED1LD0/GGIO1.AnOut1", iec61850.ControlModel.DIRECT_NORMAL
)
await apc.operate(
    {"type": "structure", "value": [{"type": "float32", "value": 1.5}]}
)

GOOSE control blocks

A GOOSE control block is administered over MMS like any other control block; publishing and subscribing to the frames themselves is out of scope (see the PICS footnote 7).

gocb = "IED1LD0/LLN0.gcbStatus"          # or "IED1LD0/LLN0$GO$gcbStatus"

values = await conn.get_gocb_values(gocb)
print(values.go_id, values.dat_set, values.conf_rev, values.dst_address)

await conn.set_gocb_values(gocb, go_id="BayStatus")   # while GoEna is false
await conn.set_gocb_values(gocb, go_ena=True)

GoCBValues carries go_ena, go_id, dat_set (with the logical device), conf_rev, nds_com, dst_address (a PhyComAddress of addr, priority, vlan_id, app_id), min_time_ms, max_time_ms and fixed_offs; a component the server omits reads None. set_gocb_values writes only the arguments given, one attribute per request. A 0.4.0 server refuses go_id and dat_set with TemporarilyUnavailable while the block is enabled, and with ObjectAccessDenied when it presents Edition 2.1.

A dst_address.addr of six zero octets means the block has no destination. When the SCL holds a connected access point of the IED (a system configuration), a server registers a GOOSE control block that has no <GSE> (or a <GSE> without a MAC-Address) disabled, with that destination, and refuses to enable it with TemporarilyUnavailable. Without a <Communication> section for the IED, as in an ICD or a model spec, the block keeps the default destination 01-0C-CD-01-00-00, APPID 0, and can be enabled.

SCL / ICD / CID parser

Load an IED configuration document and inspect it as plain Python data:

scl = iec61850.load_scl("MyDevice.icd")

scl.ieds()                          # ['IED1']

doc = scl.to_dict()
doc["ieds"][0]["name"]              # 'IED1'
doc["ieds"][0]["manufacturer"]      # 'ACME'

ld = doc["ieds"][0]["access_points"][0]["server"]["logical_devices"][0]
ld["inst"]                          # 'GenericIO'
[ln["ln_class"] for ln in ld["logical_nodes"]]   # ['LLN0', 'GGIO', ...]

# Resolve a logical-node's data objects via the DataTypeTemplates section:
ln_type_id = ld["logical_nodes"][0]["ln_type"]
ln_type = doc["data_type_templates"]["ln_node_types"][ln_type_id]
[do["name"] for do in ln_type["dos"]]            # ['Mod', 'Beh', ...]

Both load_scl and parse_scl run the full two-stage pipeline (XML syntax → cross-element type-reference resolution). The returned dict mirrors the SCL XML structure; type references stay as strings so callers can index into doc["data_type_templates"] (ln_node_types / do_types / da_types / enum_types) themselves.

For a stable text representation — useful as a regression / diff oracle — ask for the canonical summary of a single IED:

print(scl.summary("IED1"))
# IED name=IED1
#   lds count=1
#     LD inst=GenericIO ld_name=<None> lns=2
#       LN class=LLN0 inst= prefix= dos=2 ...
#       ...

Parse failures surface as SclError, a subclass of IedError, with line, column, element_path, attribute, kind, and message attributes set so the offending location is directly reachable:

try:
    iec61850.load_scl("broken.icd")
except iec61850.SclError as e:
    print(e.kind, "at", e.line, ":", e.column, "→", e.element_path, "@", e.attribute)
    # e.g. UnresolvedTypeReference at 42 : 7 → SCL/IED[name="IED1"]/.../LN[...] @ lnType

Server hosting

Host an IED defined by an SCL / ICD / CID document as an MMS server. IedServer.from_scl() builds the runtime model, bind() selects the TCP address (port 0 requests an OS-assigned port), and async with manages the lifecycle. While running, push value updates with the typed update_* methods, addressing data attributes by "<LD>/<LN>.<DO>.<DA>[.<sub>]*".

import asyncio
import iec61850

async def main():
    server = iec61850.IedServer.from_scl("plant.icd", ied_name="IED1")
    server.bind("0.0.0.0:0")
    server.vendor = "ACME"
    server.model_name = "Generic-IO"
    server.max_connections = 5

    async with server:
        print("listening on", server.bound_addr)
        while True:
            server.update_bool("GenericIO/GGIO1.Ind1.stVal", True)
            server.update_float32("GenericIO/MMXU1.TotW.mag.f", measure_power())
            await asyncio.sleep(0.1)

asyncio.run(main())

Configuration setters (vendor, model_name, revision, max_connections, the association limits below and set_edition) must be called before start(); set_write_access_policy also works on a running server. vendor, model_name, revision, max_connections and the association limits are write-only: reading one raises AttributeError.

A hosted server raises these exceptions:

Exception When
OSError start() cannot listen on the bound address, for example because the port is in use; from_scl cannot read its file
RuntimeError a call in the wrong lifecycle state: a setter or register_* after start(), start() without bind() or twice, a running-only call (bound_addr, connection_count, stop(), batch(), log_value, …) while the server is not running, a second with_tls(), concurrent batch() blocks
ValueError an argument that does not parse: a bind() address, a model spec, a token such as ctl_model
KeyError a path, logical device or data set the model does not hold: an update_* path, a report control block whose data set is unknown at start(), a setting group handler for a logical device without an SGCB
IedDataAccessError an update_* value that does not fit the attribute's type (e.g. update_float32 on a BOOLEAN)
IedServerError a model or registration the server refuses at start() or register_from_model(), such as a duplicate data set or control block (reference names it)
SclError an SCL document from_scl cannot parse or resolve

While running, connection_count reports the open connections, abort_connection(conn_id) aborts the one association a callback's conn_id names and returns whether it found it, abort_all_connections() aborts every association and returns how many it marked, and dynamic_dataset_count() counts the data sets clients have created.

The server bounds what a client can hold open:

Setter Default Effect
association_setup_timeout_ms 10 000 a connection that has not associated by then is closed
association_idle_timeout_ms 300 000 an association with no traffic for this long is aborted; None keeps it
association_send_timeout_ms 10 000 a client that does not accept a PDU within this time is disconnected
max_dynamic_datasets 64 data sets clients may create at run time, across all associations
max_dynamic_datasets_per_association 16 run-time data sets one association may have created

A report the client accepts counts as traffic, so a client that only receives reports stays associated.

The supported typed updates are update_bool, update_int32, update_int64, update_uint32, update_float32, update_float64, update_string, update_bit_string, and update_bit_string_from_int.

A BIT STRING such as a Dbpos or a Quality is updated from its octets and padding, or from an int. The int form takes the declared size n of the attribute and writes value as an n-bit number, most significant bit first: bit 0 of the string, the first on the wire, carries 2**(n-1).

# Dbpos: 0 intermediate, 1 off, 2 on, 3 bad. 2 is stored as 0x80, padding 6.
server.update_bit_string_from_int("Bay/XCBR1.Pos.stVal", 2)

# The same value from its octets; the unused trailing bits are stored as zero.
server.update_bit_string("Bay/XCBR1.Pos.stVal", bytes([0x80]), 6)

The bit count has to fit the declared size, as a remote Write must: exactly two bits for a Dbpos, one to thirteen for a Quality. A mismatch raises IedDataAccessError and leaves the attribute unchanged.

An update raises only the trigger options the attribute declares: a changed value raises a data change for dchg and a quality change for qchg, and every update raises a data update for dupd. Writing the value an attribute already holds sends no data change. The sub-attributes of a constructed attribute take its trigger options, so mag.f triggers on what mag declares. A value a client writes raises the same triggers.

Arrays

An attribute or sub-data object declared with count is an array. A client reads and writes an element by index ("LD/LN.DO.da(2)"); the server updates the whole array in one step:

server.update_array("LD/GGIO1.Arr.stVal", [True, False, True])

update_array takes one item per element, in index order; an element of a constructed type is a list in model order or a dict keyed by sub-attribute name. The shape is checked before any element changes, and the changes go out as one batch, so a report control block without a buffer time sends one report for the whole array. An on_read handler on an array returns a list of the same length, and an on_write handler on an array receives the whole array when a client writes one element.

Communication addressing

The SCL <Communication> section is read into the model and is available before and after start():

[ap] = server.connected_access_point("AP1")
ap["sub_network"], ap["address"]["ip"], ap["address"]["parameters"]["MMS-Port"]

gse = server.gse_address("LD0", "gcbStatus")   # None when there is no <GSE>
gse["mac_address"], gse["app_id"], gse["vlan_id"], gse["vlan_priority"]
gse["min_time_ms"], gse["max_time_ms"]

server.smv_address("LD0", "MSVCB01")            # an <SMV> address, or None

Each address carries every <P> under parameters (type to text) and the typed mac_address (6 bytes), app_id, vlan_id, vlan_priority and ip, None when absent. register_from_model() sets the DstAddress, MinTime and MaxTime of a GOOSE control block from its <GSE>; a server hosted from Python sends no GOOSE frames (footnote 7). A <P> value written another way than the schema form of its type (a one-digit VLAN-ID, a lower-case MAC address, an AP title or selector with white space) is read as written, with a warning. A value that cannot be read still loads: it stays under parameters, its typed key reads None, and register_from_model() registers the GOOSE control block it addresses without a destination, with a warning. A connected access point of the loaded IED that names an access point or control block the IED does not declare raises SclError; a <ConnectedAP> of an IED the file does not declare, and the other references of the section that name nothing, are skipped with a warning.

Registering what the model declares

Loading SCL or a model spec builds the model; the control blocks it declares are served only once they are registered. register_from_model() registers every data set, report control block instance, GOOSE control block, log control block and controllable data object of the model:

server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1")
server.bind("0.0.0.0:102")
server.register_from_model()        # queued; runs at start()
async with server:
    ...

Queued before start(), it runs after every explicit add_dataset / register_urcb / register_brcb / register_log_control / on_control registration and before the server accepts connections. Called while running, it registers at once and returns the counts (data_sets, urcbs, brcbs, gocbs, lcbs, sgcbs, control_objects). A report control block declared with RptEnabled max="N" is registered once per instance, named <name>01 to <name>NN when indexed. A data set or control block registered under the same reference already raises IedServerError with reference; a control object registered by on_control keeps its handlers. Setting group control blocks are served either way.

Edition and write access

set_edition("ed1" | "ed2" | "ed2.1") selects the edition the server presents; "ed2" is the default and "ed1" behaves as "ed2". The only difference is that under "ed2.1" a client may not write the GoID and DatSet of a GOOSE control block.

set_write_access_policy(fc, allow) allows or refuses remote writes under "DC", "CF", "SP", "SV", "SE" or "BL"; SP, SV and SE are allowed by default. A refused write fails with ObjectAccessDenied before any on_write handler runs. On a running server a change applies to every write that arrives afterwards, on associations already open as well. write_access_allowed(fc) reports the policy.

Association authentication

set_authenticator(callable) installs a callable that decides on every association request; set_authenticator(None) removes it, and without one every association is accepted. It receives a mapping with peer, calling_ap_title, calling_ae_qualifier, called_ap_title, called_ae_qualifier, mechanism ("none", "password", "certificate" or "other") and password (bytes or None), and returns None or True to accept, False to refuse with authentication-failure, or the name or code of an acse-service-user diagnostic that refuses the calling identity or the credentials (3 to 6: calling AP-title, AP-invocation identifier, AE-qualifier or AE-invocation identifier not recognized; 11 to 14: authentication mechanism name not recognized or required, authentication failure, authentication required) to refuse with that diagnostic. Any other value, including any other diagnostic such as 0 (null), an unknown name, or a raised exception refuses with authentication-failure. The refused client receives a Session REFUSE whose AARE carries the diagnostic and an Initiate-ErrorPDU with access object-access-denied; this package's client raises IedAuthenticationError for diagnostics 3 to 6 and 11 to 14, so every refusal by an authenticator reaches it as that exception.

def authenticate(request: dict) -> bool | str | None:
    if request["calling_ap_title"] not in ALLOWED_AP_TITLES:
        return "calling-AP-title-not-recognized"
    return request["password"] == b"s3cret"

server.set_authenticator(authenticate)

The server calls the callable while the association is set up, on a thread of its bounded blocking pool, not on a runtime worker (as it calls the other Python callbacks, see Read / write callbacks). A wait that releases the GIL (threading.Event.wait, socket I/O, time.sleep) does not hold up other associations, though while the pool is full further callbacks queue; computation that holds the GIL stalls every Python callback of the process. Keep it short. Installed before start(), it is in place before the first association; on a running server it applies to the associations requested afterwards. A password reaches it in clear unless the association runs over TLS.

Server-side TLS

with_tls() wraps the listener in an IEC 62351-3 TLS acceptor. Only valid before start(); calling it more than once raises RuntimeError.

server.with_tls(
    server_cert_pem=open("server.crt", "rb").read(),
    server_key_pem=open("server.key", "rb").read(),
)

Mutual TLS adds a CA bundle for client-chain validation and, optionally, a pinned peer list (only a client whose leaf certificate is byte for byte the DER of one of the known peers is accepted; the whole certificate is compared, not its public key, so a renewed certificate has to be added to the list):

server.with_tls(
    server_cert_pem=server_cert,
    server_key_pem=server_key,
    client_ca_pem=ca_pem,
    allow_only_known_peers=True,
    known_peer_pems=[peer1_pem, peer2_pem],
    crl_pems=[crl_pem],
)

Defaults: TLS 1.2 - 1.3, the IEC 62351-3 cipher suites listed under TLS, time validation on, session resumption on (TLS 1.2 session IDs; the server sends no TLS 1.3 session ticket, so a TLS 1.3 session does not resume), no client-cert pinning; a client certificate chain is always validated against client_ca_pem. min_tls_version and max_tls_version accept "tls1.2" / "tls1.3".

Read / write callbacks

Register per-attribute callbacks to override cached reads or intercept incoming writes. Both on_read and on_write may be called before start() (queued and installed at startup) or while the server is running (installed immediately). Re-registering the same path replaces the previous callback.

def measure_indication(path: str) -> bool:
    # Sampled from physical I/O on every client read.
    return read_io(path)

def validate_setpoint(path: str, value: int) -> bool:
    if value < 0 or value > 100:
        err = iec61850.IedDataAccessError("setpoint out of range")
        err.code = "ObjectValueInvalid"
        raise err
    apply_setpoint(value)
    return True   # also store value in the server-side cache

server.on_read("GenericIO/GGIO1.Ind1.stVal", measure_indication)
server.on_write("GenericIO/GGIO1.SetPt1.setVal", validate_setpoint)

on_read return values:

Return Behavior
any scalar the value is returned to the client
tagged dict the value is returned to the client
None fall through to the cached value
raises read fails with IedDataAccessError

A tagged dict takes the form from_model_spec accepts for value, so a callback can serve a BIT STRING such as Dbpos: {"type": "bit_string", "padding": 6, "data": b"\x80"} reads as the on state. A dict that does not convert fails the read with TypeInconsistent and prints the reason through the standard exception hook.

on_write return values:

Return Behavior
True accept; cache is updated with the incoming value
False / None accept; cache is not updated (you manage it)
raises reject; client sees IedDataAccessError

Set a code attribute on the raised exception to control the reported DataAccessError variant — "HardwareFault", "TemporarilyUnavailable", "ObjectAccessDenied", "ObjectValueInvalid", etc. Without code the server reports ObjectAccessDenied.

A handler decides every request that covers its attribute: a read of the attribute itself, of a node above it (its data object, its logical node, a functional-constraint group), of a node below it, and of a data set holding it; a write to the attribute or to any node above or below it. A handler on a data object or constructed attribute returns its value as a list in model order. The server holds no lock while a handler runs, so it may call the update_* methods.

The Python callbacks of a hosted server (read, write, control check, a synchronous control operate or wait, setting group and authenticator) run on a thread of the server's bounded blocking pool, not on a runtime worker, and take the GIL there; an async def operate or wait is called there too and its coroutine then runs on the event loop that started the server. A blocking wait in one does not hold up other associations, though while the pool is full further callbacks queue; computation that holds the GIL stalls every Python callback. Successive calls may run on different threads, so threading.local state does not carry over, and callbacks of different associations may interleave.

Pass with_context=True to receive the request as well:

def on_read(path: str, ctx: dict) -> object:
    # ctx: {"path": "GGIO1$ST$Ind1$stVal", "fc": "ST", "conn_id": 3,
    #       "requested": "GGIO1$ST$Ind1"}
    return read_io(path)

server.on_read("GenericIO/GGIO1.Ind1.stVal", on_read, with_context=True)
server.on_write("GenericIO/GGIO1.SetPt1.setVal",
                lambda path, value, ctx: True, with_context=True)

path is the canonical path the handler is registered against and requested the path the client named.

Control callbacks

on_control binds the server-side execution of a control object. Address it at the DO ("<LD>/<LN>.<DO>") and declare which IEC 61850 control model the DO uses. Up to three callbacks may be supplied, and they differ in how they refuse a command:

Callback Kind Runs Refuses the command when it
check sync only on Select (ctl_val is None), SelectWithValue and Operate, first raises; its return value is ignored
wait sync or async on Operate, after check and before the Operate response, under every control model raises, or returns False
operate sync or async on Operate, after a positive Operate response raises, or returns False
  • check is static validation: interlocks, mode, permissions. It is called as a plain function, so an async def check is never awaited and never refuses anything.
  • wait is the dynamic check, the WaitForExecution state of IEC 61850-7-2 (for example waiting for a synchro-check confirmation). Its outcome decides the Operate response.
  • operate executes the command. An Operate on an object registered without one is refused with NotSupported.

A raised exception refuses with the add cause it carries (see below); a False return refuses with Unknown. None, True and any other return value accept.

operate runs only after the client has received a positive Operate response. Under the enhanced-security models its failure reaches the client as a negative CommandTermination carrying the add cause. Under the normal-security models it is not reported to the client at all, so refuse a command from check or wait instead.

Each callback receives (path, ctl_val, action). action is a dict with ctl_num, test, synchro_check, interlock_check, is_select, t (the request timestamp as eight UTC_TIME octets), conn_id (the association that issued it), and origin (a sub-dict with or_cat and or_ident).

The server refuses a time-activated operate (an Oper with an operTm) with NotSupported.

async def operate(path: str, value: bool, action: dict) -> None:
    if action["test"]:
        return                                  # test command — no I/O
    await drive_breaker(path, value)

def check(_path: str, _value: bool, _action: dict) -> None:
    if interlock_blocked():
        err = iec61850.IedControlError("interlocked")
        err.add_cause = "BlockedByInterlocking"
        raise err

server.on_control(
    "GenericIO/GGIO1.SPCSO1",
    ctl_model="direct-normal",
    check=check,
    operate=operate,
)

ctl_model is one of "status-only", "direct-normal", "sbo-normal", "direct-enhanced", "sbo-enhanced". For SBO models the optional sbo_timeout_ms (default 30000) and sbo_class ("operate-once" or "operate-many", default "operate-once") configure the select-phase behavior. oper_timeout_ms (default 0, none) ends a command that executes for longer with TimeLimitOver. A ctlModel, sboTimeout, sboClass or operTimeout the model declares takes precedence over these arguments, so declare the control model in the SCL rather than only passing it here. The server maintains stSeld itself.

Raise an exception from any callback to reject the command. Set add_cause on the exception to the variant name (e.g. "BlockedByInterlocking", "BlockedByProcess", "NotSupported") or its numeric MMS code; absence falls back to "Unknown".

Datasets and unbuffered reporting

Declare a server-side dataset and bind it to an Unbuffered Report Control Block (URCB) before start(). The same client APIs (get_rcb_values, set_rcb_values, install_report_handler) consume reports from the URCB once the server is running.

The server stores log entries and delivers reports without calling Python code. An update_* that arrives while another thread's update is being delivered waits for that delivery, so triggers are delivered in the order the values were stored; a value overwritten within one client write request is not delivered on its own.

server.add_dataset(
    "GGIO1$ds1",
    [
        "GenericIO/GGIO1.Ind1.stVal",
        "GenericIO/GGIO1.AnIn1.mag.f",
    ],
)

server.register_urcb(
    "GenericIO/LLN0.urcb01",
    dataset="GGIO1$ds1",
    trg_ops=["data_changed", "gi"],
    opt_flds=["seq_num", "time_stamp", "reason", "data_set"],
    buf_tm_ms=50,
)

Dataset names follow the IEC 61850 convention "<LN>$<dsName>". Every entry in a dataset must belong to the same logical device. register_urcb accepts rpt_id (defaults to "<domain>/<LN>$RP$<rcb_name>"), conf_rev, trg_ops, opt_flds, buf_tm_ms, and intg_pd_ms.

Trigger options: "data_changed", "quality_changed", "data_update", "integrity", "gi", plus the aliases "all" and "none".

Optional fields: "seq_num", "time_stamp", "reason", "data_set", "data_reference", "conf_rev", "buffer_overflow", "entry_id". An unbuffered control block has no buffer and no EntryID (IEC 61850-7-2 §17.2.4), so the server clears buffer_overflow and entry_id from its reports.

Datasets without a URCB are still reachable via get_data_set_values.

A report carries only the reasons the control block's TrgOps enable, for the triggers each member's attribute declares: an SCL attribute without dchg="true" (or qchg, dupd) sends no report on that trigger. A data object or constructed attribute member is included whole when any attribute beneath it triggers. A client reads DatSet back as "<LD>/<LN>$<name>".

Buffered reporting (BRCB)

register_brcb mirrors register_urcb but binds the dataset to a Buffered Report Control Block ($BR$ MMS path). Reports are held in a per-RCB ring buffer until a client connects, so transient disconnects do not lose updates.

server.register_brcb(
    "GenericIO/LLN0.brcb01",
    dataset="GGIO1$ds1",
    trg_ops=["data_changed", "gi"],
    opt_flds=[
        "seq_num", "time_stamp", "reason", "data_set",
        "buffer_overflow", "entry_id",
    ],
    buf_tm_ms=50,
    buffer_capacity=128,
)

A BRCB sends buffer_overflow and entry_id when they are selected (IEC 61850-7-2 §17.2.2.8); a URCB clears them. Additional knobs:

  • buffer_capacity (default 64) — entry-count ring size; the buffer evicts oldest entries when full and surfaces overflow through the buffer_overflow field on the next report. The first report after every enable also carries buffer_overflow set.
  • with_resv_tms (default True) — expose the Edition 2+ ResvTms field for client reservation.
  • with_owner (default False) — expose the Edition 2+ Owner field.

The same dataset can back both a URCB and a BRCB; client-side APIs (get_rcb_values, set_rcb_values, install_report_handler, ReportDispatcher) handle both transparently — RcbHandle.is_buffered discriminates them.

Logging (LCB)

register_log_control declares a Log Control Block ($LG$ MMS path). Each block backs onto an in-memory journal (InMemoryLogStorage), which can be unbounded (default) or capped to a fixed entry count (oldest entries are evicted on overflow). Clients name the journal by the block's log_ref and pull it over MMS ReadJournal with query_journal / query_journal_all.

server.add_dataset("LLN0$evlogds", ["GenericIO/GGIO1.Ind1.stVal"])
server.register_log_control(
    "GenericIO/LLN0.lcb01",
    dataset="LLN0$evlogds",
    log_ref="IED1GenericIO/LLN0$EventLog",
    trg_ops=["data_changed", "integrity"],
    intg_pd_ms=60_000,
    storage_capacity=1000,
)

async with server:
    server.update_bool("GenericIO/GGIO1.Ind1.stVal", True)   # logged
    server.log_value(
        "GenericIO/LLN0.lcb01",
        data_ref="IED1GenericIO/GGIO1$ST$Ind2$stVal",
        value=True,
        reason_code=0x02,            # bit 1 = data_changed
    )

The server records the journal itself: an update of a member of the block's data set (registered with add_dataset or register_from_model) writes an entry when the block's trg_ops enable a reason the update raises — data change, quality change or data update — and integrity writes one entry holding the whole data set every intg_pd_ms. General interrogation writes none. Updates made inside batch() write one entry per block. log_value adds an entry of the application's own, for example for a value outside the data set or with a chosen timestamp, and returns its 8-byte entry id (as an int), or None when the block's LogEna is disabled. Toggle the enable state at runtime with set_log_ena(path, on).

Setting groups (SGCB)

A Setting Group Control Block is declared in SCL on <LN0>:

<LN0 lnClass="LLN0" inst="" lnType="LLN0_0">
  <SettingControl numOfSGs="3" actSG="1" resvTms="60"/>
</LN0>

The server tracks ActSG / EditSG / ConfirmEditSG state, enforces the single-client edit-session lock, and times out abandoned reservations. Python applications opt into the three veto / commit points per LD. on_act_sg(new_sg, conn_id), on_edit_sg(new_sg, conn_id) and on_confirm(edit_sg, conn_id) all return bool | None. None or True accepts the request. False, any other return value, or a raised exception refuses it with ObjectAccessDenied: the client's write raises IedDataAccessError with code == 3. A refused confirmation commits nothing and leaves the edit session open. on_confirm runs before the staged FC=SE values are committed, so it is where an application persists them.

def on_act_sg(new_sg: int, conn_id: int) -> bool:
    return new_sg in allowed_sgs        # return False → ObjectAccessDenied

def on_confirm(edit_sg: int, conn_id: int) -> None:
    persist_pending_settings(edit_sg)   # None accepts; False refuses

server.register_setting_group_handler(
    "GenericIO",
    on_act_sg=on_act_sg,
    on_confirm=on_confirm,
)

get_setting_group_info(ld_inst) returns the live snapshot (num_of_sg / act_sg / edit_sg / cnf_edit / last_act_tm_ms / resv_tms_s). force_active_setting_group(ld_inst, sg) switches the active group without consulting the callback — intended for startup state restoration. Calling register_setting_group_handler again at runtime atomically replaces the previous handler.

The server holds the values of every group. SelectActiveSG loads the values of the new group into the FC=SG attributes, SelectEditSG loads the edited group into FC=SE, and ConfirmEditSGValues stores FC=SE back into the group (and into FC=SG when it is the active one). Read or replace a group's value from the application with:

server.get_setting_group_value("GenericIO/PTOC1.StrVal.setMag.f", 2)
server.set_setting_group_value("GenericIO/PTOC1.StrVal.setMag.f", 2, 1.25)

Replacing a value of the active group updates the served attribute too; a value of another group takes effect when that group is activated. In SCL a setting carries one <Val sGroup="n"> per group.

Clients drive SGCB through the regular write API on the special MMS path. ActSG and EditSG are INT8U, so write them as a tagged unsigned value (or with write_uint32); a plain Python int is sent as a signed MMS INTEGER, which a server that checks the declared type refuses:

group = {"type": "uint", "value": 2}
await conn.write("IED1GenericIO/LLN0.SGCB.ActSG", FC.SP, group)   # SelectActiveSG
await conn.write("IED1GenericIO/LLN0.SGCB.EditSG", FC.SP, group)  # open edit
await conn.write("IED1GenericIO/LLN0.SGCB.CnfEdit", FC.SP, True)  # commit

The server this package hosts also accepts a non-negative INTEGER there.

Building a server from a model dict (no SCL)

When the IED schema is generated in Python — code-driven test rigs, dynamic device skeletons, or runtimes that prefer dict-driven configuration over XML — from_model_spec consumes a declarative spec dict that maps onto the same model the SCL parser produces. The RCB / LCB / SGCB declarations land in the model exactly as SCL-derived ones would: the SGCB is served on its own, and register_from_model() registers the data sets, RCBs and LCBs. Every callback and register_* method works against the same "<LD>/<LN>.<DO>[.<DA>]*" paths.

spec = {
    "ied_name": "IED1",
    "lds": [{
        "inst": "GenericIO",
        "lns": [
            {
                "lln0": True,
                "dos": [{
                    "name": "Mod",
                    "das": [
                        {"name": "stVal", "fc": "ST", "type": "Enumerated",
                         "trg_ops": ["data_changed"],
                         "value": {"type": "int", "value": 1}},
                        {"name": "q", "fc": "ST", "type": "Quality"},
                        {"name": "t", "fc": "ST", "type": "Timestamp"},
                    ],
                }],
                "sgcb": {"num_of_sg": 3, "act_sg": 1},
            },
            {
                "class": "GGIO", "inst": "1",
                "dos": [{
                    "name": "Ind1",
                    "das": [
                        {"name": "stVal", "fc": "ST", "type": "Boolean"},
                        {"name": "q", "fc": "ST", "type": "Quality"},
                        {"name": "t", "fc": "ST", "type": "Timestamp"},
                    ],
                }],
                "datasets": [{
                    "name": "Events", "entries": [
                        {"ln_name": "GGIO1", "fc": "ST",
                         "do_path": ["Ind1", "stVal"]},
                    ],
                }],
                "rcbs": [{
                    "name": "Events01", "buffered": False,
                    "dataset_ref": "Events", "conf_rev": 1,
                    "trg_ops": ["data_changed", "integrity"],
                    "opt_flds": ["seq_num", "time_stamp", "reason"],
                    "buf_tm_ms": 100,
                }],
            },
        ],
    }],
}

server = iec61850.IedServer.from_model_spec(spec)
server.bind("127.0.0.1:0")
async with server:
    ...

type takes one of these tokens, spelled exactly so:

Group Tokens
Boolean "Boolean"
Signed integers "Int8", "Int16", "Int24", "Int32", "Int64", "Int128"
Unsigned "Int8U", "Int16U", "Int24U", "Int32U"
Floating point "Float32", "Float64"
Enumerations "Enumerated", "CodedEnum" (two bits, such as a Dbpos)
Strings "VisibleString", "OctetString", "UnicodeString255"
Bit strings "GenericBitString", "Quality", "Check", "OptFlds", "TrgOpsBits", "SvOptFlds", "LogOptFlds"
Time "Timestamp", "EntryTime"
Other "PhyComAddr", "Currency", "Constructed"

"VisibleString" and "OctetString" take a maximum length in bytes and "GenericBitString" one in bits, through the object form {"type": "OctetString", "max_len": 64}; without it they default to 64, 64 and 8. Any other spelling raises ValueError, and so does an SCL bType name (BOOLEAN, INT32, Dbpos, VisString64, …), which is not a token. The SCL types translate as follows:

SCL bType type
BOOLEAN, INT8 … INT128, INT8U … INT32U, FLOAT32, FLOAT64 the token of the same name in the case above ("Boolean", "Int8", "Int8U", "Float32", …)
Enum "Enumerated"
Dbpos, Tcmd "CodedEnum"
VisString32 … VisString255 {"type": "VisibleString", "max_len": n}
ObjRef {"type": "VisibleString", "max_len": 129}
Octet6, Octet16, Octet64 {"type": "OctetString", "max_len": n}
EntryID {"type": "OctetString", "max_len": 8}
Unicode255 "UnicodeString255"
TrgOps "TrgOpsBits"
Struct an entry under "constructed_das" (below)
Quality, Timestamp, Check, EntryTime, PhyComAddr, Currency, OptFlds, SvOptFlds, LogOptFlds the same name
value is a tagged dict ({"type": "int", "value": 1}, `{"type":
"bit_string", "padding": 3, "data": b"\x00\x00"}`, …) or
{"type": "default"} for the type's zero. Constructed (SDA-bearing)
DAs go under "constructed_das" with a "children" list; nested DOs
go under "sub_dos". The underlying IedModelBuilder enforces all
invariants (LLN0 first, SGCB only on LLN0, dataset entries resolve to
real LN/DO) and surfaces violations as ValueError.

Batch updates

server.batch() returns a synchronous context manager that holds the server's data-model lock for the duration of the with block. The triggers of the updates made inside it are raised together when the block exits: a report control block without a buffer time sends one report, a buffered one stores one entry, and a log control block writes one entry. Buffer-time expiry and integrity and general-interrogation reports wait until the block exits, so keep it short. Client reads are not held back. Concurrent batches raise RuntimeError rather than deadlocking, so callers can choose to retry or fail fast.

with server.batch():
    server.update_bool("GenericIO/GGIO1.Ind1.stVal", True)
    server.update_float32("GenericIO/GGIO1.AnIn1.mag.f", 12.5)
    server.update_int32("GenericIO/GGIO1.SetPt1.setVal", 7)

Error handling

try:
    conn = await iec61850.IedConnection.connect("10.0.0.1:102", timeout_ms=2000)
except iec61850.IedTimeoutError as e:
    ...   # connection timed out after e.timeout_ms
except iec61850.IedSessionRefusedError:
    ...   # peer refused the association at the session layer
except iec61850.IedTlsError as e:
    ...   # TLS handshake failed; e.kind says why
except iec61850.IedConnectionError as e:
    ...   # TCP / OSI stack failure; e.reason says which
except iec61850.IedError:
    ...   # catch-all base for any IEC 61850 error

Each exception carries attributes a caller can branch on; an attribute that does not apply reads None.

Exception Attributes
IedConnectionError reason ("connection-lost", "released-by-peer", "transport", "associate-failed", "initiate-failed"), kind and detail of a transport failure, code of a refused Initiate
IedSessionRefusedError reason_code, transport_disconnect, provider_reason
IedAuthenticationError diagnostic and diagnostic_name of the refusing AARE; reason is "authentication-rejected"
IedTlsError kind ("verification", "alert_received", "version_unsupported", "cipher_unsupported", "timeout", "io", "other"), message
IedTimeoutError timeout_ms
IedServiceError reason ("service-error", "reject", "conclude-rejected", "outstanding-limit", "pdu-too-large", "name-list-limit", "name-list-not-advancing", "journal-not-advancing"), error_class, code, reject_type, number_deleted, pdu_size, max_size, limit
IedDataAccessError code, the MMS DataAccessError value
IedServerError reference of a refused duplicate registration

IedSessionRefusedError and IedTlsError derive from IedConnectionError. IedTimeoutError derives from IedError only: a request, connect or command-termination timeout is not caught by except IedServiceError. A connection that drops after it was established raises IedConnectionError (reason "connection-lost", "released-by-peer" or "transport"), not IedServiceError. reason == "transport" is an I/O failure other than a close, such as a refused connection; a connection the peer resets or closes is "connection-lost".

timeout_ms of connect and connect_tls bounds the TCP connection, the TLS handshake (connect_tls) and the COTP handshake together. Running out of it raises IedTimeoutError whose timeout_ms is the value given; running out of it during the TLS handshake raises IedTlsError with kind == "timeout". The Session, ACSE and MMS Initiate exchange that follows is bounded by request_timeout_ms (5000 ms when not given), whose expiry raises IedTimeoutError carrying that value.

Release notes

0.16.0

Tracks iec61850-rust v0.4.0.

Breaking changes

  • TlsConfig, IedConnection.connect_tls and IedServer.with_tls lose chain_validation: the certificate chain is always validated. Drop the argument.

    # 0.15
    tls = iec61850.TlsConfig(ca_pem=ca, chain_validation=True)
    # 0.16
    tls = iec61850.TlsConfig(ca_pem=ca)
    
  • ControlObjectClient.select() returns a ControlOutcome instead of a bool. An outcome is truthy exactly when it succeeded, so if await ctl.select(): keeps working; compare .success where the code tested identity.

    # 0.15
    assert await ctl.select() is True
    # 0.16
    assert (await ctl.select()).success
    
  • A ControlOutcome is truthy exactly when the command succeeded. In 0.15 it had no truth value of its own, so if await ctl.operate(v): and if await ctl.cancel(v): were always true; they now take the failure branch when the server refuses. Handle the refusal there, or drop the test where the code has to run either way.

    # 0.15: always entered
    if await ctl.operate(True): ...
    # 0.16: entered only on success
    outcome = await ctl.operate(True)
    if outcome: ...
    else: print(outcome.add_cause)
    
  • Add cause 24 reads as "blocked-by-command" instead of "abortion-by-command". ControlAddCause.ABORTION_BY_COMMAND stays an alias of BLOCKED_BY_COMMAND and the old token still parses, but code that compares the string no longer matches. Compare the enum member.

    # 0.15
    if outcome.add_cause == "abortion-by-command": ...
    # 0.16
    if outcome.add_cause is iec61850.ControlAddCause.BLOCKED_BY_COMMAND: ...
    
  • The action dict passed to on_control callbacks carries t (the request timestamp as eight UTC_TIME octets) and conn_id instead of ctl_time_ms.

    # 0.15
    when_ms = action["ctl_time_ms"]
    # 0.16
    t_octets, conn = action["t"], action["conn_id"]
    
  • Client failures raise the exception class of their cause. The class hierarchy is unchanged (IedTimeoutError derives from IedError only, as before); what moves is which class a failure raises:

    Failure 0.15 0.16
    A request times out IedServiceError IedTimeoutError
    A connect times out in the TCP or COTP stage IedConnectionError IedTimeoutError
    An established connection is lost, released by the peer, or fails in transport IedServiceError IedConnectionError with reason "connection-lost", "released-by-peer" or "transport"
    The peer refuses the association for the calling identity or the credentials IedSessionRefusedError IedAuthenticationError (a subclass of IedConnectionError, not of IedSessionRefusedError)

    except IedServiceError no longer catches a request timeout or a lost connection, except IedConnectionError around connect no longer catches a connect timeout, and except IedSessionRefusedError no longer catches an authentication refusal. Catch the classes together, or branch on reason:

    # 0.15
    except iec61850.IedServiceError: ...   # also caught timeouts and disconnects
    # 0.16
    except (iec61850.IedServiceError, iec61850.IedTimeoutError,
            iec61850.IedConnectionError): ...
    # or
    except iec61850.IedConnectionError as e:
        if e.reason in ("connection-lost", "released-by-peer", "transport"):
            ...   # reconnect
    
  • The data sets, report, GOOSE and log control blocks and control objects a model declares are served only once registered. Call register_from_model(), or keep the explicit add_dataset / register_* / on_control calls. A report control block registered from the model is named per instance, <name>01 when indexed.

    # 0.15
    server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1")
    # 0.16
    server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1")
    server.register_from_model()
    
  • A journal is named by the LogRef of its log control block, not by the control block reference.

    # 0.15
    await conn.query_journal_by_time("IED1LD0/LLN0$LG$lcb01", t0, t1)
    # 0.16
    await conn.query_journal_by_time("IED1LD0/LLN0$EventLog", t0, t1)
    
  • A hosted server writes the journal itself for every member of an LCB's data set (data change, quality change, data update and integrity, as the block's TrgOps select). Stop calling log_value for those members, or each change is logged twice; register the data set so the block can record it.

    # 0.15
    server.update_bool("LD0/GGIO1.Ind1.stVal", True)
    server.log_value("LD0/LLN0.lcb01", data_ref=ref, value=True)
    # 0.16
    server.add_dataset("LLN0$dsStatus", ["LD0/GGIO1.Ind1.stVal"])
    ...
    server.update_bool("LD0/GGIO1.Ind1.stVal", True)    # logged
    
  • Under the normal-security control models a failing operate callback is no longer reported to the client. Refuse the command from check or wait.

    # 0.15
    server.on_control(path, ctl_model="direct-normal", operate=refuse_if_blocked)
    # 0.16
    server.on_control(path, ctl_model="direct-normal",
                      check=refuse_if_blocked, operate=operate)
    
  • A ctlModel, sboTimeout, sboClass or operTimeout the model declares takes precedence over the arguments of on_control. Declare the control model in the SCL.

    <!-- 0.15: on_control(..., ctl_model="sbo-normal") overrode this -->
    <DAI name="ctlModel"><Val>direct-with-normal-security</Val></DAI>
    <!-- 0.16 -->
    <DAI name="ctlModel"><Val>sbo-with-normal-security</Val></DAI>
    
  • An attribute reports only the trigger options it declares. Declare dchg (or qchg, dupd) on an SCL attribute that should report, and give a model-spec attribute that should report a trg_ops list; one without it raises none.

    <!-- 0.15 -->
    <DA name="stVal" fc="ST" bType="BOOLEAN"/>
    <!-- 0.16 -->
    <DA name="stVal" fc="ST" bType="BOOLEAN" dchg="true"/>
    
  • max_outstanding is limited to 65535.

  • MmsValue and ControlParams are removed. No method returned or took either: a generic read() returns native values (list, bytes, ...), and ControlObjectClient takes its settings through its setters. Drop the imports.

    A value written as an MmsValue is written as a native or tagged value:

    0.15 0.16
    MmsValue.structure(...) {"type": "structure", "value": [...]}
    MmsValue.array(...) a list
    MmsValue.octet_string(b) bytes

    Each ControlParams field has a setter or an argument of its own:

    ControlParams field 0.16
    ctl_val the argument of operate(value)
    test set_test(True)
    check_synchrocheck set_synchro_check(True)
    check_interlock set_interlock_check(True)
    origin_orcat, origin_orident set_origin(OriginValue(or_cat=..., or_ident=...))
    operate_time no replacement: a 0.4.0 server refuses an Oper carrying an operTm with NotSupported
    # 0.15
    await ctl.operate(iec61850.ControlParams(ctl_val=True, test=True))  # never accepted
    # 0.16
    ctl.set_test(True)
    await ctl.operate(True)
    
  • InclusionReason.application_trigger is removed. It was never set: the client decodes data change, quality change, data update, integrity and general interrogation. The ReasonCode bit it stood for, bit 6, is not used for reports by IEC 61850-8-1, so no report carries it and no capability is lost. Drop the reads.

  • A TLS handshake that stalls past timeout_ms raises IedTlsError with kind == "timeout" (a subclass of IedConnectionError) instead of IedTimeoutError. Catch both around connect_tls:

    try:
        conn = await IedConnection.connect_tls(addr, tls, "ied1", timeout_ms=3000)
    except (iec61850.IedTimeoutError, iec61850.IedTlsError) as e:
        ...
    
  • on_confirm can refuse a confirmation. In 0.15 its return value was ignored and an exception was only reported, so the commit always went ahead. Now False, a return value other than None or a bool, or an exception refuses the ConfirmEditSGValues with ObjectAccessDenied. A callback that raised to report a problem but still wants the commit must catch it, and one that returned a truthy non-bool must return True or None:

    def on_confirm(edit_sg: int, conn_id: int) -> None:
        try:
            persist(edit_sg)
        except OSError:
            log.exception("persisting setting group %d failed", edit_sg)
        # returning None accepts the confirmation
    

Added

  • IedConnection.get_server_identity() (MMS Identify) returns a ServerIdentity; get_server_status(extended_derivation=False) (MMS Status) returns a ServerStatus.

  • JournalQuery and IedConnection.query_journal(log_ref, query), one ReadJournal request with any selection, and query_journal_all, which follows more_follows and returns each entry once.

  • max_name_list_names on connect, connect_tls and Iec61850ClientConfig caps the names one directory walk collects.

  • ClientReport.included, sub_seq_num and more_segments_follow.

  • IedConnection.get_gocb_values and set_gocb_values, with the GoCBValues and PhyComAddress dataclasses.

  • ControlOutcome.last_appl_error and the LastApplError dataclass; ControlAddCause.BLOCKED_BY_COMMAND ("blocked-by-command"), with ABORTION_BY_COMMAND kept as an alias and its token still parsed.

  • IedTlsError, a subclass of IedConnectionError, for a failed TLS handshake, with kind and message; 0.15 raised a plain IedConnectionError, so except IedConnectionError still catches it. IedConnectionError, IedServiceError, IedTimeoutError, IedDataAccessError and IedServerError carry attributes naming the cause (see Error handling).

  • IedServer.register_from_model(), update_array(path, values), set_edition(edition), get_setting_group_value(path, group), set_setting_group_value(path, group, value), set_write_access_policy(fc, allow), write_access_allowed(fc), abort_all_connections() and dynamic_dataset_count().

  • on_read and on_write take with_context=True to receive the request context (path, fc, conn_id, requested).

  • on_control takes oper_timeout_ms.

  • Raw SCL type dictionaries carry count and count_ref for DA, BDA and SDO declarations, and a report control dictionary carries indexed.

  • from_model_spec accepts the attribute types Int24, SvOptFlds and LogOptFlds, and a report control block in a spec takes indexed and max_instances (not indexed unless asked, so its name is kept).

  • IedServer.update_quality(path, quality) takes a Quality or the integer Quality.to_bits() returns, in the bit order read_quality decodes; update_bit_string_from_int keeps its most-significant-bit-first order.

  • spawn_report_dispatcher takes on_error, called once with the exception that ends polling; ReportDispatcher.done and exception() report it.

  • IedConnection.read_timestamp_with_quality(ref, fc) returns the time and its TimeQuality (leap_second_known, clock_failure, clock_not_synchronized, time_accuracy).

  • IedServer.with_tls takes require_client_auth: with a client_ca_pem, True refuses a client that presents no certificate (by default such a client is admitted); without a client_ca_pem, start() raises ValueError.

  • AcsiClass.LOG_CONTROL ("LCB") lists the log control blocks of a logical node; AcsiClass.LOG lists its logs (journals).

  • IedServer.abort_connection(conn_id) aborts the one association named by the conn_id the read, write and control callbacks receive. That connection sends an ACSE A-ABORT and closes, possibly after the call returns; every other association stays open. It returns True when it found the association and False for an id naming no open association. Raises RuntimeError when the server is not running.

  • Tagged value {"type": "structure", "value": [...]}: the components in order, each a plain value or a tagged dict, so structures nest. write, select_with_value, operate and cancel accept it; an APC sends its AnalogueValue ctlVal as {"type": "structure", "value": [{"type": "float32", "value": 1.5}]}. A server control callback receives a structure as a list of its components.

  • SclError.kind reads "UnresolvedDataSetReference" for a control block whose datSet names no data set of its logical node, which the SCL reader refuses.

  • ACSE authentication: IsoConnectionParameters.password (the ACSE password mechanism), IedAuthenticationError with diagnostic and diagnostic_name, and IedServer.set_authenticator(callable), which decides on every association request from its AP-titles, AE-qualifiers and credentials.

  • IedServer.set_write_access_policy also applies on a running server, to the writes that arrive afterwards.

  • IedServer.connected_access_point(ap_name), gse_address(ld_inst, cb_name) and smv_address(ld_inst, cb_name) read the SCL <Communication> addressing from the model.

Fixed

  • connect and connect_tls honour a timeout_ms above 10 s. The attempt used to end after 10 s with timeout_ms == 10000, and a shorter deadline raised IedTimeoutError with timeout_ms unset; it now carries the value given. timeout_ms now bounds the TCP connection, the TLS handshake and the COTP handshake only, no longer the Session, ACSE and MMS Initiate exchange that follows, which request_timeout_ms bounds (5000 ms when not given): a peer that answers COTP but not the session can hold connect(timeout_ms=2000) for about 5 s.

Changed behavior (from iec61850-rust 0.4.0)

  • Reports: a report larger than the negotiated PDU size arrives in segments, each delivered separately; a report carries only the reasons its control block's TrgOps enable; rewriting a value with itself sends no data change; the sub-attributes of a constructed attribute take its trigger options, so mag.f triggers on what mag declares; a value a client writes raises the triggers its attribute declares.
  • batch() raises the triggers of its updates as one batch on exit (one report without a buffer time, one log entry per log control block); periodic reports wait for it, and client reads are not held back.
  • Logging: data update and integrity are recorded as well as data and quality change; general interrogation writes no entry.
  • Report control blocks: DatSet reads back as "<LD>/<LN>$<name>"; enabling an unreserved URCB reserves it and disabling keeps the reservation until resv=False; writing any other attribute of an unreserved URCB does not reserve it; gi=True on a disabled block, and configuration, purge_buf and entry_id writes on an enabled BRCB, fail with TemporarilyUnavailable; conf_rev counts DatSet changes only; the first report after every BRCB enable carries BufOvfl; a full report channel no longer clears RptEna or Resv.
  • Owner and ResvTms of an SCL-built control block exist only when its <ReportSettings> declares owner="true" / resvTms="true"; an SCL <TrgOps> that omits gi now enables it.
  • Setting groups: the server holds the values of every group and SelectActiveSG loads them into FC=SG; reading or writing FC=SE outside an edit session answers TemporarilyUnavailable.
  • Control: an Oper with an operTm is refused with NotSupported; a second select of a selected object fails; cancelling an idle direct control fails; a selection ends on its own sboTimeout; the server maintains stSeld; a refused operate reports the add cause the server sends instead of unknown.
  • Arrays: an attribute or sub-data object declared with count is an MMS array whose elements a client reads and writes by index; a read handler on an array returns a list of the element count.
  • Writes: a whole data object can be written; an integer out of range answers ObjectValueInvalid and a string or octet string of a wrong length TypeInconsistent; a Quality written with fewer bits reads back with 13.
  • Read and write handlers are asked for reads and writes above and below their own path, and for data set reads; a handler on a data object or constructed attribute answers in model order.
  • Data sets: CreateDataSet takes data objects, constructed attributes and array elements as members, up to 1024 members and 4096 attributes, and a Write up to 4096 items; beyond, the error is resource capability-unavailable instead of access other. GetDataSetDirectory lists an array element member as the array with an alternate access.
  • GI and integrity reports read a data object or constructed attribute written concurrently whole or not at all.
  • A GoCB DatSet reads as "<LD>/LLN0$<name>".
  • Python callbacks of a hosted server, a synchronous control operate or wait included, run on a thread of the server's blocking pool instead of a runtime worker: a blocking wait no longer holds up other associations, oper_timeout_ms ends a synchronous operate that runs past it (the callback finishes on its thread, its result ignored), successive calls may run on different threads, and callbacks of different associations may interleave.
  • Report and log triggers are delivered in the order the values were stored; a value overwritten within one client write request is not delivered on its own.
  • A GOOSE control block registered from the model takes DstAddress, MinTime and MaxTime from its SCL <GSE>. When the SCL holds a connected access point of the IED, one without a <GSE> (or without a MAC-Address) is disabled, reads a destination of six zero octets, and cannot be enabled; without a <Communication> section it keeps the default destination and can be enabled.
  • The SCL <Communication> section is read into the model. A <P> value written another way than its schema form is read with a warning; one that cannot be read loads, reads None from its typed key, and leaves the GOOSE control block it addresses without a destination. A connected access point of the loaded IED naming what the IED does not declare raises SclError; a <ConnectedAP> of an IED the file does not declare is skipped with a warning. Scl.summary() lists the connected access points and GSE / SMV addresses.
  • A client refused at Initiate raises IedSessionRefusedError; one refused for its calling identity or credentials raises IedAuthenticationError; a client refused by TLS gets the alert reason.
  • Directory walks keep the server's order without duplicates, and SCL errors start with "SCL error at"; data object members follow the DOType declaration order.

0.15.2

Tracks iec61850-rust v0.3.2. No API changes; the entries below are what a hosted server and a client now do differently.

  • ClientReport.entries: a member the report does not carry has every reason flag cleared. Its value is still the last one received, and an entry does not yet say whether the report carried it.
  • A buffered report control block enabled over MMS sends its reports to the association that enabled it; enabled without an EntryID write, it starts from the oldest buffered entry. While it is enabled, a write from another association fails with ObjectAccessDenied. When the association ends the block is disabled but keeps buffering, and a client that enables it again resumes after the last entry sent.
  • Integrity reports run for a report control block enabled over MMS whose TrgOps includes integrity and whose IntgPd is above zero, one every IntgPd milliseconds from the moment RptEna is written true.
  • A buffered report control block reserved with a positive ResvTms is held for the peer address that reserved it, for ResvTms seconds after that association ends; a write from any other address fails with ObjectAccessDenied. ResvTms written as the 16-bit integer set_rcb_values sends is accepted, and a value outside 0..=32767, or an unsigned report control block value wider than 32 bits, fails with object-value-invalid instead of being truncated.
  • A hosted server clears the unused trailing bits of a bit string it receives in a Write or SetDataSetValues, and of one it sends in a Read.

0.15.1

Tracks iec61850-rust v0.3.1.

  • IedServer.update_bit_string(path, data, padding) and IedServer.update_bit_string_from_int(path, value) — update a BIT STRING attribute such as a Dbpos or a Quality on a running server. The bit count has to fit the declared size of the attribute, exactly 2 for a Dbpos and 1 to 13 for a Quality, or the call raises IedDataAccessError and the value stays. update_bit_string_from_int writes an unsigned value as many bits wide as the declared size, most significant bit first, so a Dbpos of 2 is stored as b"\x80" with padding 6. Both trigger reports by the trigger options of the attribute.
  • write_bit_string and the tagged bit_string value, wherever it is accepted, clear the unused trailing bits of the last octet before the value is sent or stored; they used to pass them through.
  • A remote Write, a SetDataSetValues member or an on_read return value whose bit string does not fit the declared size of the attribute is refused: the Write fails with IedDataAccessError and leaves the value, and the read answers object-value-invalid. Only the type used to be checked, so an empty or 13-bit string could replace a two-bit Dbpos.
  • A typed update of an attribute whose trigger options name qchg and not dchg, such as q, triggers a quality change, so a report control block enabled for dchg alone no longer reports it; every update used to count as a data change.

0.15.0

Tracks iec61850-rust v0.3.0, whose server limits and checks change what a client and a hosted server observe; the entries below say how.

  • IedConnection.read_bit_string and write_bit_string — typed access to a BIT STRING attribute as its data octets and padding count, most significant bit first: a Dbpos of on is (b"\x80", 6).
  • Tagged values — on_read callbacks, IedConnection.write, set_data_set_values, log_value and the control select_with_value, operate and cancel accept the {"type": ...} dictionaries from_model_spec takes, so a callback can answer a Dbpos read with {"type": "bit_string", "padding": 6, "data": b"\x80"}.
  • IedServer.association_setup_timeout_ms, association_idle_timeout_ms, association_send_timeout_ms, max_dynamic_datasets and max_dynamic_datasets_per_association — settable before start().
  • A hosted server closes a connection that has not completed the MMS Initiate within 10 s of being accepted, aborts an association that neither sends nor receives a PDU for 300 s (a client that only receives reports stays connected), and closes a connection whose peer stops accepting PDUs for 10 s.
  • A hosted server bounds the data sets clients create at run time, 64 in total and 16 per association by default; past either limit CreateDataSet fails with IedServiceError.
  • max_connections counts a connection from the moment it is accepted rather than from a completed Initiate.
  • SetDataSetValues applies the checks of a single write to every member: a member under a read-only functional constraint, or one the on_write handler refuses, keeps its value and reports an error while the others are written.
  • URCB reservations and control selections are released when a connection ends on a transport or protocol error as well as on a normal close, and a setting-group edit session is released whenever its connection closes. BRCB reservations still wait for ResvTms, so a client can resume after reconnecting.
  • Read and Write requests are decoded under the nesting level the association negotiated. A reassembled TSDU past 73 192 bytes on the client, or past the negotiated PDU size plus 8 192 bytes on the server, closes the connection.
  • from_model_spec refuses a tagged bit_string whose padding is outside 0..=7, or non-zero with empty data. When an on_read return value cannot be converted, the reason is printed through the standard exception hook before the read fails with TypeInconsistent.

0.14.0

  • get_data_set_directory — the ACSI GetDataSetDirectory service, returning a DataSetDirectory with each data set member as an IEC reference and its functional constraint.
  • read_multiple — reads several object references with their functional constraints in a single MMS Read, in request order.
  • get_data_set_values and read_multiple accept strict=False, returning a DataAccessFailure for a failing entry in place of raising IedDataAccessError.
  • Corrected the documented iec61850.AcsiClass member for listing a logical node's data set names: AcsiClass.DATASET.
  • IsoConnectionParameters — the ISO addressing an association offers is now settable per connection through IedConnection.connect(), connect_tls() and Iec61850ClientConfig. The default selectors follow IEC 61850-8-1 (P-SEL 00 00 00 01); the default AP-titles 1.1.1.999 and 1.1.1.999.1 with AE-qualifier 12 on both sides are the values IEDs customarily expect. Previous releases sent empty presentation selectors and no AP-title.
  • IedSessionRefusedError — a session REFUSE SPDU now raises a dedicated subclass of IedConnectionError carrying reason_code, transport_disconnect and provider_reason, instead of a generic connection failure.
  • The ServiceError errorClass subcodes now follow the ISO 9506-2 ServiceError ASN.1 named numbers, and a Confirmed-ErrorPDU decodes per its [0] IMPLICIT invokeID tag. A server refusal now surfaces through IedServiceError carrying the standard ErrorClass rather than a generic parse failure.

Who is using this?

The project is free to use in any setting, commercial deployments included, and no registration is required. If you do run it somewhere, saying so helps other readers judge where the implementation has been exercised. Add an entry to ADOPTERS.md by opening an issue with the adopter template, or open a GitHub Discussion if you would rather ask something first. Naming an organization is optional; a description of the use case on its own is welcome.

License

MIT OR Apache-2.0, at your option. See LICENSE-MIT and LICENSE-APACHE. The upstream iec61850-rust workspace is licensed under the same terms.

Metadata

Release files for iec61850 0.16.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Built distributions (wheels)

Table of built distributions (wheels) for iec61850 0.16.0
File Interpreter ABI Platform Actions
iec61850-0.16.0-cp311-abi3-win_amd64.whl CPython 3.11 abi3 Windows x86-64 Details for iec61850-0.16.0-cp311-abi3-win_amd64.whl
iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl CPython 3.11 abi3 Linux glibc 2.17+ x86-64 Details for iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl

Total release size: 7.5 MB

Release files / iec61850-0.16.0-cp311-abi3-win_amd64.whl

Download URL iec61850-0.16.0-cp311-abi3-win_amd64.whl
Size 3.9 MB
Tags CPython 3.11 Windows x86-64 abi3
SHA-256 checksum
How to use checksums
4a52e4795090e51a09da41a098ecf41e7bad0e906fd40c4bc4dd768640e5e50b
BLAKE2b-256 checksum
How to use checksums
9b11d5cc30fbe1871764898c955439590be7ef39c9e67ad6acc6fbcdbc680d0c
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.14.8

Release files / iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl

Download URL iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl
Size 3.6 MB
Tags CPython 3.11 Linux glibc 2.17+ x86-64 abi3
SHA-256 checksum
How to use checksums
d958b3dad9693e9e0b8a86a74313459675fafa080ae2b6fa3ccf714ee0a510c1
BLAKE2b-256 checksum
How to use checksums
c57414fdc1dddb15ab57ea0922ac069012418a510d117614268705fe3f4320f1
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.14.8

Security for iec61850 0.16.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

To learn more about protecting yourself from malicious actors, visit our package security documentation.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page