iec61850
Async-first, type-hinted IEC 61850 MMS client and server for Python.
Scope and protocol boundaries
This package is an MMS-only facade over
iec61850-rust — an independent
Rust implementation of IEC 61850 by the same author, itself open source under
the same MIT OR Apache-2.0 terms and published on crates.io as the
iec61850-* crates. This facade covers
the connection-oriented, application-level services that fit Python's runtime
characteristics naturally:
- Client: read / write / control / dataset / reporting (URCB + BRCB) / log query / GOOSE control block administration / SCL parsing / directory queries / server identity and status / TLS
- Server hosting: MMS server with URCB / BRCB / LCB / GoCB / SGCB /
control handlers, declared from SCL or from a Python
dictspec
Out of scope by design: GOOSE (IEC 61850-8-1) and Sampled Values (IEC 61850-9-2) are hard-real-time L2 protocols (GOOSE T1 = 4 ms, SV = 250 us / 4 kHz). Their timing budgets fit Rust + SCHED_FIFO, not a GIL-bound runtime with non-deterministic GC pauses. Misrepresenting them as "supported" in Python would invite production protection-scheme failures.
If you need GOOSE / SV publish or subscribe, use the upstream Rust crates directly (same author, same wire-level implementation):
iec61850-goose— GOOSE publisher / subscriber / receiver (Ethernet L2 raw socket, frame template, retransmission state machine)iec61850-sv— Sampled Values 4 kHz publisher + subscriber (Linux SCHED_FIFO publish loop, p99 jitter target < 200 us)
The PICS table below uses a four-column Py-C / Py-S / Rust-C / Rust-S
breakdown precisely so an unsupported Python row points you at the right
Rust crate.
Features
- TCP connect / disconnect with timeout
- TLS connect (IEC 62351-3 cipher whitelist, mutual TLS, TLS 1.2 + 1.3,
known-peer pinning, CRL, hostname and time validation knobs; the
certificate chain is always validated, and a failed handshake raises
IedTlsErrornaming its kind) - Per-connection tuning: request timeout, max outstanding invocations, local max PDU size
- High-level
Iec61850Clientasync context manager wrapping the lifecycle of anIedConnectionplus an optional backgroundReportDispatcher - Typed scalar read / write:
bool,int32,int64,uint32,float,float64,string,timestamp(decoded todatetime),quality(decoded to aQualitydataclass), andbit_stringas(data, padding) - Generic
read/writewith array-element and sub-component selection;writealso takes a tagged value dict for types no Python type selects - Directory queries:
get_server_directory,get_logical_device_directory,get_logical_node_directory(AcsiClass),get_data_directory; a walk stops pastmax_name_list_namesnames - Server identity and state:
get_server_identity(MMS Identify) andget_server_status(MMS Status) - Schema introspection:
get_variable_specification(ref, fc)(recursive MMS type tree) andget_device_model()(per-LD named-variable index) - Dataset admin:
create_data_set,delete_data_set,get_data_set_values,set_data_set_values - Connection control:
disconnect(graceful) andabort(rude close — drop TCP without sending MMS Conclude) - URCB / BRCB reporting:
get_rcb_values,set_rcb_values,install_report_handler,poll_reports, backgroundReportDispatcher; each report says which members it carries (included) and which segment of a segmented report it is - Log service:
query_journal(log_ref, JournalQuery)for one ReadJournal request with any selection,query_journal_allto read every page, and thequery_journal_by_time/query_journal_after_entryshorthands; a journal is named by its LogRef - GOOSE control block administration over MMS:
get_gocb_valuesandset_gocb_values(GOOSE frames themselves stay out of scope) - SCL / ICD / CID document parser:
load_scl(path)/parse_scl(xml)→Sclhandle exposing IED inventory, the full document as a nested dict, and a canonical text summary per IED - Server hosting:
IedServer.from_scl(path, ied_name=...)instantiates an MMS server from an SCL document, orIedServer.from_model_spec(spec)from a declarative Python dict when the IED is generated in code rather than authored as XML. Bind, configure (vendor / model name / max connections / association timeouts / run-time data set limits), enter viaasync with, push value updates with typedupdate_*methods and whole arrays withupdate_array, intercept reads / writes withon_read/on_writecallbacks (optionally with the request context), serve control commands (SBO / direct, normal / enhanced) withon_control—operateandwaitcallbacks may be either sync orasync— register every data set, report, GOOSE and log control block and control object the model declares withregister_from_model(), or expose URCB / BRCB reporting viaadd_dataset/register_urcb/register_brcband Log Control Blocks viaregister_log_control(in-memory journal recorded from the data set members,ReadJournalover MMS,log_valuefor further entries), wire Setting Group callbacks per LD withregister_setting_group_handler+force_active_setting_groupand read or replace the values of each group; choose the edition (set_edition) and the functional constraints clients may write (set_write_access_policy); group updates withwith server.batch():so they report and log as one batch; terminate TLS at the server withwith_tls()(same IEC 62351-3 profile as the client, plus client-cert pinning) - Control:
select,select_with_value,operate,cancelacross the four IEC 61850 control models (direct-normal/direct-enhanced/sbo-normal/sbo-enhanced), each returning aControlOutcomethat carries the add cause and theLastApplErrorthe server reported - Typed exception hierarchy:
IedError,IedConnectionError,IedSessionRefusedError,IedTlsError,IedTimeoutError,IedDataAccessError,IedServiceError,IedControlError,IedServerError; each carries attributes naming the cause - SNTP / NTP client:
query_sntp(addr, timeout_s)returns anSntpResponsewith server time, clock offset, and round-trip estimate computed per RFC 4330 §5;addris an IP address and port such as"192.0.2.10:123"or"[2001:db8::1]:123" - Type stubs (
_native.pyi) and apy.typedmarker for full mypy / pyright coverage of the public surface - Cookbook of runnable examples under
examples/(quickstart client, server from SCL, server from model dict, BRCB reporting, control SBO, SNTP query)
Install
pip install iec61850
Requires Python 3.11+. Wheels are published for Windows x86_64 and Linux x86_64
(manylinux 2014); macOS arm64 is built and tested in CI but not yet published.
They are abi3 wheels: one build serves every supported Python 3.11 or later.
Building from source
Only needed to work on the package itself; installing from PyPI needs no Rust
toolchain. You will need a stable Rust toolchain (edition 2021, MSRV 1.88) and
uv.
The Rust side is not vendored. Cargo.toml takes each crate from the
implementation repository at the release tag this version tracks:
iec61850-client = { git = "https://github.com/csp0924/iec61850-rust", tag = "v0.4.0", features = ["tls"] }
With that tag published, a build is just:
uv sync # dev environment, including maturin and pytest
uv run maturin develop --release
uv run pytest -q
Building against a local checkout
To build against an unreleased iec61850-rust — a tag not yet published, or
changes made to both repositories together — clone it next to this one so the two
share a parent directory:
<parent>/
iec61850-rust/
iec61850-python/
Then create .cargo/config.toml, which is git-ignored precisely so this
override never ships:
[patch."https://github.com/csp0924/iec61850-rust"]
iec61850-client = { path = "../iec61850-rust/crates/iec61850-client" }
iec61850-model = { path = "../iec61850-rust/crates/iec61850-model" }
iec61850-mms = { path = "../iec61850-rust/crates/iec61850-mms" }
iec61850-scl = { path = "../iec61850-rust/crates/iec61850-scl" }
iec61850-server = { path = "../iec61850-rust/crates/iec61850-server" }
iec61850-sntp = { path = "../iec61850-rust/crates/iec61850-sntp" }
iec61850-tls = { path = "../iec61850-rust/crates/iec61850-tls" }
A patch redirects a package, but Cargo still loads the git source it is patching before applying the patch. So while the tag is not published, that config alone is not enough — resolution fails with:
failed to load source for dependency `iec61850-client`
Unable to update https://github.com/csp0924/iec61850-rust?tag=v0.4.0
Seed a lock file once and the patch takes over. Cargo's git backend needs an absolute URL here, so derive one rather than hard-coding it. From the repository root, with the sibling checkout in place:
# Absolute path to the sibling checkout. `pwd -W` is the Git-for-Windows
# spelling that yields `D:/...`; plain `pwd` covers Linux and macOS.
RUST_REPO=$(cd ../iec61850-rust && { pwd -W 2>/dev/null || pwd; })
# 1. Point the manifest at that checkout, just long enough to resolve.
sed -i "s|https://github.com/csp0924/iec61850-rust\", tag = \"v0.4.0|file://${RUST_REPO}\", branch = \"main|g" Cargo.toml
cargo generate-lockfile
# 2. Restore the manifest and relabel the source lines the lock recorded.
# Cargo canonicalises the URL it stores, so match on the branch suffix
# rather than on the exact spelling passed in above.
git checkout Cargo.toml
sed -i -E "s|git\+file://[^\"]*\?branch=main|git+https://github.com/csp0924/iec61850-rust?tag=v0.4.0|g" Cargo.lock
Cargo.lock is git-ignored for the same reason: it pins a revision the
published repository does not carry yet. After this, cargo metadata resolves
offline and reports the patched packages coming from
../iec61850-rust/crates/*, and uv run maturin develop --release builds
against your working tree — edits on the Rust side are picked up without a
commit.
Once the tag Cargo.toml names is published, delete .cargo/config.toml and
Cargo.lock and build normally; none of this is needed any more.
Conformance (PICS)
ACSI service support per IEC 61850-7-2 Edition 2; the section numbers below follow that edition.
- Py-C / Py-S — exposed through this Python package (client / server).
- Rust-C / Rust-S — supported somewhere in the upstream
iec61850-rustworkspace.
Legend: yes supported; — not yet implemented; partial a stated subset
(see the footnote); no, by design deliberately not in Python (use the named
Rust crate instead); n/a not applicable; (n) footnote. The Rust columns
follow the upstream conformance statement,
docs/PICS.md,
which carries the full per-service detail.
Application Association (§8)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| Associate (Two-Party, MMS/TCP) | yes | yes | yes | yes |
| Abort (graceful Conclude) | yes | yes | yes | yes |
| Abort (rude — TCP drop) | yes | yes | yes | yes |
| Release | yes | yes | yes | yes |
| Configurable ISO addressing | yes | — | yes | — |
| TLS 1.2 / 1.3 (IEC 62351-3) | yes (1) | yes (1) | yes | yes |
| Mutual TLS / pinned peer / CRL | yes | yes | yes | yes |
| Authentication (ACSE password) | yes (15) | yes (15) | yes | yes |
| Association gating (AP-title) | — | yes (15) | — | yes |
-
Includes 62351-3 cipher whitelist,
verify_hostnameandtime_validationknobs, version pinning, and known-peer profile; the certificate chain is always validated. A failed client handshake raisesIedTlsErrorwith itskind. Backed byiec61850-tls. -
The client sends
IsoConnectionParameters(password=...)as the ACSE password mechanism; a refusal naming the calling identity or the credentials raisesIedAuthenticationError. The server decides on each association throughIedServer.set_authenticator. The IEC 62351-4 certificate mechanism is not implemented; peer authentication by certificate is done by TLS.
Server class (§7)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetServerDirectory | yes | yes | yes | yes |
| GetServerCapabilities (Ed.2) | — | — | — | — |
| MMS Identify | yes | yes | yes | yes |
| MMS Status | yes | yes | yes | yes |
The hosted server answers Identify with the vendor, model_name and
revision it is configured with.
Logical Device class (§9)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetLogicalDeviceDirectory | yes | yes | yes | yes |
Logical Node class (§10)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetLogicalNodeDirectory | yes | yes | yes | yes |
| GetAllDataValues | — | — | — | yes |
Data class (§11)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetDataValues | yes | yes (2) | yes | yes |
| SetDataValues | yes | yes (2) | yes | yes |
| GetDataDirectory | yes | yes | yes | yes |
| GetDataDefinition / GetVariableSpec | yes | yes | yes | yes |
| Array element access (read / write) | yes | yes | yes | yes |
- Server applies the write access policy (default
SP | SV | SE;set_write_access_policyalso opensDC,CFandBL, beforestart()or while running) and any registeredon_read/on_writecallbacks, which are asked for reads and writes above and below their own path and can receive the request context.update_arrayupdates a whole array attribute as one batch.
GetDataValues covers both the single read (read) and the batched form
(read_multiple), which carries any set of references in one MMS Read.
Data Set class (§13)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetDataSetValues | yes | yes | yes | yes |
| SetDataSetValues | yes | yes | yes | yes |
| CreateDataSet (dynamic) | yes | yes | yes | yes |
| DeleteDataSet | yes | yes | yes | yes |
| GetDataSetDirectory (members) | yes | yes | yes | yes |
| List data set names (GetLogicalNodeDirectory DS) | yes | yes | yes | yes |
| Static (SCL-defined) datasets | yes | yes (3) | yes | yes |
- Server registers static datasets through
add_dataset()or, for every data set the model declares,register_from_model(); either bound to a control block or exposed standalone forGetDataSetValues.
Substitution (§5.3.3)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| Set substituted value (FC=SV writes) | partial (12) | partial (12) | partial (12) | partial (12) |
| Dedicated Substitution service API | — | — | — | — |
- The
SVfunctional constraint is writable by the default write access policy, andMV,CMVandSAVcarry the substitution attributes, but a read does not itself switch to the substituted value.
Setting Group Control Block — SGCB (§16)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| SelectActiveSG / SelectEditSG | partial (6) | yes (6) | partial (6) | yes |
| GetSGCBValues / SetSGCBValues | partial (6) | yes (6) | partial (6) | yes |
| ConfirmEditSGValues | partial (6) | yes (6) | partial (6) | yes |
| Setting access (FC=SG / FC=SE writes) | yes | yes | yes | yes |
| Values of every setting group | n/a | yes | n/a | yes |
- Server-side SGCB is declared via SCL
<SettingControl numOfSGs="N"/>on LN0; runtime ActSG / EditSG / ConfirmEditSG state machine plus reservation timeout are owned by the server, which also holds the values of every group: SelectActiveSG loads the group into the FC=SG attributes and ConfirmEditSGValues stores the FC=SE buffer into it. Python applications install per-LD callbacks (on_act_sg/on_edit_sg/on_confirm) throughregister_setting_group_handler(), canforce_active_setting_group()on startup, and read or replace the value a group holds withget_setting_group_value()/set_setting_group_value(). Clients, in Python and in Rust alike, drive SGCB through the generic write API on the special MMS path (e.g.write("IED1LD0/LLN0.SGCB.ActSG", FC.SP, {"type": "uint", "value": 2})); neither has a dedicated setting-group API.
Reporting — URCB / BRCB (§17.2)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| URCB — GetURCBValues / SetURCBValues | yes | yes | yes | yes |
| URCB — Report (TrgOps, OptFlds, BufTm, IntgPd) | yes | yes | yes | yes |
| URCB — General Interrogation | yes | yes | yes | yes |
| BRCB — GetBRCBValues / SetBRCBValues / Report | yes | yes (4) | yes | yes |
Segmentation (SubSeqNum / MoreFollows) |
yes | yes | yes | yes |
| Per-member inclusion of a report | yes | yes | yes | yes |
| Instances from the model | n/a | yes | n/a | yes |
| Background report dispatcher | yes | n/a | yes | n/a |
- Server BRCB hosting via
register_brcb()orregister_from_model()with in-memory ring buffer (entry-count semantics), EntryID resync, and theupdate_*trigger path. The first report after each enable carriesBufOvflset.
Logging — LCB / Log (§17.3)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| Log (recording on trigger) | n/a | yes (5) | n/a | yes |
| ReadJournal (every optional field) | yes | yes (5) | yes | yes |
| ReadJournal pagination (read to end) | yes | yes | yes | yes |
| LCB — GetLCBValues | — | yes | — | yes |
| LCB — SetLCBValues | — | — | — | — |
| GetLogStatusValues | — | yes | — | yes |
| QueryLogByTime / QueryLogAfter | yes | yes (5) | yes | yes |
| Log purging | — | — | — | — |
- Server LCB hosting via
register_log_control()orregister_from_model()with an in-memory journal backend (optionally capacity-bounded, evicts oldest on overflow). The server writes an entry whenever a member of the block's data set changes value or quality or is updated, as itsTrgOpsenable, and one entry holding the whole data set everyIntgPd; general interrogation writes none.log_valueadds entries of the application's own.LogEnatoggles at runtime viaset_log_ena. A journal is named by the block'sLogRef.
Generic Substation Event — GOOSE / GSE (§18)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GoCB — Get / Set values | partial (14) | partial (14) | partial (14) | partial (14) |
| GOOSE publish | no, by design (7) | no, by design (7) | n/a | yes |
| GOOSE subscribe | no, by design (7) | no, by design (7) | yes | n/a |
- By design, not on the Python roadmap. GOOSE is a hard-real-time L2
protocol (IEC 61850-8-1; T1 retransmission floor = 4 ms; protection
schemes require deterministic dispatch). Python's GIL + non-deterministic
GC make it unsuitable for the GOOSE hot path. Use
iec61850-goosedirectly — it providesGoosePublisher(frame template + retransmission state machine),GooseSubscriber(smpCnt continuity + Q4), and a typestateGooseReceiver. - MMS administration of a GOOSE control block, which involves no
Ethernet frame. The client reads the nine components with
get_gocb_valuesand writesGoEna,GoIDandDatSetwithset_gocb_values, one attribute per request. The hosted server serves the GoCBsregister_from_model()registers;GoIDandDatSetare writable whileGoEnais false, and read-only underset_edition("ed2.1"). The other six components are read-only, andFixedOffsalways reads false.
Transmission of Sampled Values — SVCB (§19) (8)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| MSVCB / SVCB — Get / Set values | no, by design | no, by design | — | — |
| Sampled-value publish | no, by design | no, by design | n/a | yes |
| Sampled-value subscribe | no, by design | no, by design | yes | n/a |
- By design, not on the Python roadmap. SV runs at 4 kHz with a
p99 jitter budget < 200 us (protection profile 256 samples/cycle is
even tighter). This is achievable on Linux with SCHED_FIFO + raw
socket — not from a GIL-bound runtime. Use
iec61850-svdirectly — it providesSvPublisherwith frame-template + hot-path setters, a Linuxpublish_thread(clock_nanosleep-based), andSvSubscriberwith smpCnt continuity tracking.
Control (§20)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| status-only | yes | yes | yes | yes |
| direct-normal | yes | yes | yes | yes |
| sbo-normal | yes | yes | yes | yes |
| direct-enhanced | yes | yes | yes | yes |
| sbo-enhanced | yes | yes | yes | yes |
| Select / SelectWithValue | yes | yes | yes | yes |
| Operate / Cancel | yes | yes | yes | yes |
| Test mode, ctlNum, origin | yes | yes | yes | yes |
| TimeActivatedOperate | — | — | — | — (13) |
| AddCause / LastApplError | yes | yes | yes | yes |
| Control settings from the model | n/a | yes | n/a | yes |
| Operate timeout | n/a | yes | n/a | yes |
- The Rust server refuses an
Opercarrying anoperTmother than 0 with the add cause Not-supported.
A ctlModel, sboTimeout, sboClass or operTimeout the model declares
takes precedence over the arguments of on_control; register_from_model()
registers every controllable data object of the model.
Time and Time Synchronization (§21)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| UTC time read (Timestamp DA) | yes | yes | yes | yes |
| Time-quality flags on update | n/a | yes | n/a | yes |
| SNTP / NTP responder | — | — | n/a | yes (9) |
| SNTP / NTP client | yes (10) | n/a | yes (10) | n/a |
- SNTPv4 unicast server in
iec61850-sntp(mode 3 → mode 4 reply). Not exposed from Python by design: answering time requests with useful accuracy needs the host clock, timestamping close to the socket and a UDP port of its own, which an IED's operating system time service provides; the package covers the client side (footnote 10). - SNTPv4 unicast client. From Python use
iec61850.query_sntp(addr, timeout_s); from Rust useiec61850_sntp::SntpClient. Single-sample offset / round-trip via RFC 4330 §5 four-timestamp formula.addris an IP address with its port ("192.0.2.10:123"); a host name is not resolved and raisesValueError, so resolve it first, for example withloop.getaddrinfo.
File Transfer (§23)
| Service | Py-C | Py-S | Rust-C | Rust-S |
|---|---|---|---|---|
| GetFile / SetFile / DeleteFile | — (11) | — (11) | — (11) | — (11) |
| GetFileAttributeValues | — (11) | — (11) | — (11) | — (11) |
| GetServerDirectory(FILE) | — (11) | — (11) | — (11) | — (11) |
- File services are deferred until the upstream Rust workspace ships PDU encode / decode, a client API, and server-side dispatch. The Python package will pick them up once that Rust client surface lands.
Tooling (out-of-band)
| Capability | Python | Rust |
|---|---|---|
| SCL / ICD / CID parser | yes | yes |
| Two-stage SCL pipeline (XML + cross-element resolution) | yes | yes |
Typed-spec introspection (TypeSpec) |
yes | yes |
Code-driven IedModel construction |
yes | yes |
| Async SNTP / NTP client | yes | yes |
Not exposed from Python
Beyond GOOSE and Sampled Values frames (footnotes 7 and 8), a few parts of the Rust API stay out of this package on purpose:
- Raw Ethernet access and the choice of an L2 backend: they need platform privileges and driver-level setup.
IedServer::tick_log_integrity: it takes astd::time::Instant, which Python cannot supply; the server drives integrity logging from its own timer.IedServer::lock_data_model: its guard holds the data-model lock across calls, which deadlocks easily from Python;batch()covers grouped updates.BlockingMmsClient: the package is async throughout.- Building GOOSE or Sampled Values publisher settings from the model
(
CommParameters::from_address,SvPublisherBuilder::with_address): they configure frame publishing, which stays out of the package (footnotes 7 and 8);gse_addressandsmv_addressread the addresses. - The internal registries, the reporting engine and the storage traits:
they bypass the
update_*path; the server methods above cover what they do. - Request blocking on a server connection (
block_requests/set_block_requests): the server uses it for maintenance and while it aborts a connection; aborting the connection drops a client outright. IedServer::set_ignore_read_access: it bypasses every read handler at once; register or omiton_readhandlers instead.IedConnection::get_logical_node_variables: it returns the raw MMS variable names of one logical node, whichget_device_model()already lists for the whole device.IedConnection::get_data_directory_by_fc:get_variable_specificationwith that functional constraint names the same children, with their types.ControlObjectClient::wait_command_termination:operate()under an enhanced-security model already waits for the CommandTermination and reports its outcome.- The options of
IedServer::register_from_model_with(log storage factory, GOOSE destination factory, wall clock): they supply Rust objects the server calls from its own threads on every log entry and publication, which from Python would take the GIL on those paths;register_from_model()uses in-memory logs and the system clock, andregister_log_controlconfigures one log explicitly. DataAttribute::assign: it writes the model without raising reports or log entries;update_*,update_arrayandbatch()do the same with triggers.- The SNTP server (footnote 9).
TlsStream::negotiated_cipher_suite: the client keeps its TLS stream inside the connection and exposes none, so there is nothing to ask; the suite is always one of the fixed list under TLS.- Persistent report buffers (the SQLite backend): it needs the
sqlite-backendfeature, which the wheels do not build, plus a database path and a lifetime the application manages;register_brcbbuffers in memory. - The TLS 1.3 session ticket count of a hosted server
(
tls13_session_tickets): it stays at 0, as some TLS 1.3 clients close the connection when a ticket arrives; TLS 1.2 session resumption works. - The IEC 62351-3 TLS event handler (
with_event_handler): the TLS layer calls it synchronously on its own threads for every event, so a Python callback would take the GIL inside each handshake; handshake failures surface asIedTlsErroron the client.
Quick start
import asyncio
import iec61850
async def main():
conn = await iec61850.IedConnection.connect("127.0.0.1:102", timeout_ms=5000)
try:
status = await conn.read_int32("DemoIEDLD0/LLN0.Mod.stVal", iec61850.FC.ST)
vendor = await conn.read_string("DemoIEDLD0/LLN0.NamPlt.vendor", iec61850.FC.DC)
quality = await conn.read_quality("DemoIEDLD0/GGIO1.Ind1.q", iec61850.FC.ST)
print(status, vendor, quality.validity)
finally:
await conn.disconnect()
asyncio.run(main())
TLS
ca_pem = open("ca.pem", "rb").read()
tls = iec61850.TlsConfig(ca_pem=ca_pem)
conn = await iec61850.IedConnection.connect_tls(
"ied.example.com:3782",
tls,
server_name="ied.example.com",
timeout_ms=5000,
)
Mutual TLS adds a client cert and key:
tls = iec61850.TlsConfig(
ca_pem=open("ca.pem", "rb").read(),
client_cert_pem=open("client.crt", "rb").read(),
client_key_pem=open("client.key", "rb").read(),
)
The certificate chain is always validated against ca_pem; there is no
switch to turn that off. Defaults: TLS 1.2-1.3, IEC 62351-3 cipher
whitelist, time validation on, session resumption on. Set
verify_hostname=False on TlsConfig to skip SNI / SAN hostname matching
for closed-network commissioning, or time_validation=False to accept a
certificate outside its validity period (chain validation still applies).
The cipher suites are fixed to the IEC 62351-3 list the underlying TLS library implements, on the client and on the hosted server alike, and no argument adds or removes one:
| Version | Cipher suites |
|---|---|
| TLS 1.2 | TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384, TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256, TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384 |
| TLS 1.3 | TLS13_AES_128_GCM_SHA256, TLS13_AES_256_GCM_SHA384 |
The TLS_DHE_RSA_* suites IEC 62351-3 also permits are not offered, so a
peer that supports only those fails the handshake.
Pinned peers, CRL, version pinning
tls = iec61850.TlsConfig(
ca_pem=open("ca.pem", "rb").read(),
# Restrict accepted server certificates to a fixed allow-list
# (IEC 62351-3 known-peer profile): the server's leaf certificate must
# equal one of these, compared as whole DER certificates.
allow_only_known_peers=True,
known_peer_pems=(open("ied1.crt", "rb").read(),),
# Pin a single TLS version.
min_version=iec61850.TlsVersion.TLS_1_3,
max_version=iec61850.TlsVersion.TLS_1_3,
# Revocation checks.
crl_pems=(open("ca.crl.pem", "rb").read(),),
)
Handshake failures
A handshake that fails while the connection is being established raises
IedTlsError, a subclass of IedConnectionError. Its kind says why:
"verification" (the peer certificate was not accepted),
"alert_received" (the peer refused, for example the client certificate),
"version_unsupported", "cipher_unsupported", "timeout", "io" or
"other"; message holds the TLS error text.
try:
conn = await iec61850.IedConnection.connect_tls("10.0.0.1:3782", tls)
except iec61850.IedTlsError as e:
print("TLS refused:", e.kind, e.message)
High-level client
Iec61850Client wraps IedConnection as an async context manager and
optionally runs a background report dispatcher:
cfg = iec61850.Iec61850ClientConfig(
address="ied.example.com",
port=102,
timeout_ms=5000,
# Tuning that flows down into the underlying MMS client.
request_timeout_ms=3000,
max_outstanding=4,
local_max_pdu_size=16384,
# Background dispatcher; None to disable.
report_dispatcher_interval_ms=100,
)
async with iec61850.Iec61850Client(cfg) as cli:
val = await cli.connection.read_float(
"DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX
)
For TLS, pass a TlsConfig on the config and (optionally) override the SNI:
cfg = iec61850.Iec61850ClientConfig(
address="10.0.0.1", # network address
port=3782,
tls=iec61850.TlsConfig(ca_pem=ca_pem),
tls_server_name="ied.example.com", # SNI; defaults to `address`
)
The same request_timeout_ms / max_outstanding / local_max_pdu_size
keyword arguments are also accepted on IedConnection.connect and
IedConnection.connect_tls for callers that prefer to manage the connection
lifecycle directly. max_outstanding is limited to 65535.
max_name_list_names (on both, and on Iec61850ClientConfig) caps the
names one directory walk collects; past it the walk fails with
IedServiceError whose reason is "name-list-limit".
Generic read / write
# Native Python types: scalars surface as bool / int / float / str;
# bytes-like kinds as bytes; arrays and structures as list.
value = await conn.read("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX)
# A remote Write is accepted for FC=SP, SV, and SE by default; the
# server-side write access policy decides the rest.
await conn.write(
"DemoIEDLD0/GGIO1.SetPt1.setVal", iec61850.FC.SP, 42
)
A value no Python type selects is written as a tagged dict, the form
IedServer.from_model_spec takes. A BIT STRING carries its octets first bit
first, in the most significant bit of the first octet, and the number of
unused trailing bits in the last octet:
# Dbpos "on" (binary 10): one octet, six unused trailing bits.
await conn.write(
"LD/XCBR1.PosSet.setVal",
iec61850.FC.SP,
{"type": "bit_string", "padding": 6, "data": b"\x80"},
)
# The typed pair does the same and keeps the padding on the way back.
await conn.write_bit_string("LD/XCBR1.PosSet.setVal", iec61850.FC.SP, b"\x80", 6)
data, padding = await conn.read_bit_string("LD/XCBR1.Pos.stVal", iec61850.FC.ST)
A structure is written as {"type": "structure", "value": [...]}: its
components in order, each a plain value or a tagged dict, so structures nest.
A structure read back, or handed to a server callback, is a list of its
components.
# AnalogueValue with its f component only.
await conn.write(
"LD/GGIO1.AnOut1.setMag",
iec61850.FC.SP,
{"type": "structure", "value": [{"type": "float32", "value": 1.5}]},
)
Array elements and sub-components are addressed with keyword arguments:
# Reads the third element of an array DA.
elem = await conn.read("LD/LN.Arr", iec61850.FC.ST, array_index=2)
# Reads `stVal` inside the third element.
sub = await conn.read(
"LD/LN.Arr", iec61850.FC.ST, array_index=2, component="stVal"
)
Schema introspection
# Per-variable MMS TypeSpecification, returned as a nested dict.
ts = await conn.get_variable_specification(
"DemoIEDLD0/LLN0.Mod", iec61850.FC.ST
)
# ts == {"kind": "structure", "components": [
# {"name": "stVal", "type": {"kind": "integer", "width_bits": 32}},
# {"name": "q", "type": {"kind": "bit_string", "bits": 13}},
# ...
# ]}
# Whole device-model index — list of logical devices with their MMS
# NamedVariable names. First call fetches; subsequent calls hit a cache.
model = await conn.get_device_model()
for ld in model["logical_devices"]:
print(ld["name"], len(ld["variables"]))
# Force a re-fetch if the server model may have changed.
fresh = await conn.get_device_model(refresh=True)
Every type-spec node carries a "kind" discriminator. Scalar kinds add
payload fields appropriate for the type (width_bits, format_width /
exponent_width, max_chars, bits, ...). "array" adds element_count
plus a recursive element_type. "structure" adds components — a list of
{"name", "type"} entries. "unknown" surfaces the raw ASN.1 tag for
forward compatibility.
Datasets
await conn.create_data_set(
"DemoIEDLD0/LLN0.ds1",
[
iec61850.DataSetMember("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX),
iec61850.DataSetMember("DemoIEDLD0/GGIO1.Ind1.stVal", iec61850.FC.ST),
],
)
values = await conn.get_data_set_values("DemoIEDLD0/LLN0.ds1")
# values is a list ordered to match the data set members.
await conn.set_data_set_values("DemoIEDLD0/LLN0.ds1", [3.14, True])
deleted = await conn.delete_data_set("DemoIEDLD0/LLN0.ds1")
DataSetMember accepts optional array_index / component to target an
array element or a sub-component (component requires array_index); the
facade composes the alternate-access reference for you.
get_data_set_values and set_data_set_values raise IedDataAccessError
when any single entry's access or write fails on the server, with the entry
index in the error message.
What a data set holds
directory = await conn.get_data_set_directory("DemoIEDLD0/LLN0.dsStatus")
directory.deletable # False for an SCL-declared set, True for a
# set built with create_data_set()
for member in directory.members:
print(member.fc.value, member.object_ref)
Members come back in the order the server holds them, which is the order
get_data_set_values returns its entries in, and in the reference form
create_data_set accepts — so a directory read clones a data set:
await conn.create_data_set("DemoIEDLD0/LLN0.ds_clone", directory.members)
Listing the data set names of a logical node is a different service:
get_logical_node_directory(ln_ref, iec61850.AcsiClass.DATASET).
Reading several objects in one round trip
values = await conn.read_multiple(
[
("DemoIEDLD0/GGIO1.Ind1.stVal", iec61850.FC.ST),
("DemoIEDLD0/MMXU1.TotW.mag.f", iec61850.FC.MX),
],
)
The result follows the request order and has the same length. No named variable list has to exist on the server, so any set of attributes can be polled with a single MMS Read.
Per-entry failures
By default one failing entry raises IedDataAccessError. Pass
strict=False to read_multiple or get_data_set_values to keep the
successful values and receive a DataAccessFailure in the failing position:
values = await conn.read_multiple(targets, strict=False)
for target, value in zip(targets, values, strict=True):
if isinstance(value, iec61850.DataAccessFailure):
print(f"{target[0]} unavailable: {value.error}")
DataAccessFailure.error is the symbolic MMS DataAccessError name (for
example "ObjectNonExistent") and .code the value carried on the wire.
Connection control
# Normal close — MMS Conclude exchange, then TCP shutdown.
await conn.disconnect()
# Rude close — drop the TCP socket without negotiation. Use when the peer
# stops responding or a normal disconnect would block.
await conn.abort()
Server identity and status
identity = await conn.get_server_identity() # MMS Identify
print(identity.vendor, identity.model, identity.revision)
status = await conn.get_server_status() # MMS Status
print(status.logical, status.physical) # e.g. "state-changes-allowed", "operational"
ServerIdentity.abstract_syntaxes lists the abstract syntaxes the server
announces as dotted OIDs. ServerStatus names a value outside the
standard set "other" and keeps the wire value in logical_code /
physical_code; local_detail is the optional detail bit string as a
tuple of bool. get_server_status(extended_derivation=True) asks the
server to derive the state from a fresh self-check.
ISO addressing
The association a client opens carries the transport, session and presentation
selectors and the ACSE application-entity titles. The default selectors are the
values IEC 61850-8-1 specifies for an MMS association, and the default AP-titles
and AE-qualifier are the values IEDs customarily expect, which the standard
leaves to the configuration; pass an IsoConnectionParameters when a device
expects something else.
| Field | Default | Limit |
|---|---|---|
local_t_sel |
b"\x00\x01" |
4 bytes |
remote_t_sel |
b"\x00\x01" |
4 bytes |
local_s_sel |
b"\x00\x01" |
16 bytes |
remote_s_sel |
b"\x00\x01" |
16 bytes |
local_p_sel |
b"\x00\x00\x00\x01" |
16 bytes |
remote_p_sel |
b"\x00\x00\x00\x01" |
16 bytes |
local_ap_title |
"1.1.1.999" |
dotted OID |
remote_ap_title |
"1.1.1.999.1" |
dotted OID |
local_ae_qualifier |
12 |
signed 32-bit |
remote_ae_qualifier |
12 |
signed 32-bit |
iso = iec61850.IsoConnectionParameters(
remote_p_sel=b"\x00\x00\x00\x02",
remote_ap_title="1.3.9999.13",
)
conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)
# The same parameter is accepted by connect_tls() and by
# Iec61850ClientConfig(iso=...).
An over-long selector or a malformed AP-title raises ValueError when the
parameters are built, before any socket is opened. An AP-title of None leaves
that field out of the ACSE AARQ.
password sends the ACSE password mechanism (a str goes out as its UTF-8
octets). It travels in clear unless the association runs over TLS, and the
dataclass repr leaves it out. A server that refuses the calling identity or
the credentials raises IedAuthenticationError, a subclass of
IedConnectionError, whose diagnostic and diagnostic_name give the
acse-service-user diagnostic of the refusal:
iso = iec61850.IsoConnectionParameters(password="s3cret")
try:
conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)
except iec61850.IedAuthenticationError as e:
print(e.diagnostic, e.diagnostic_name) # 13 authentication-failure
Releases before 0.14.0 always offered empty presentation selectors and no AP-title or AE-qualifier at all. A peer configured to expect that addressing can be given it back:
iso = iec61850.IsoConnectionParameters(
local_p_sel=b"",
remote_p_sel=b"",
local_ap_title=None,
remote_ap_title=None,
local_ae_qualifier=None,
remote_ae_qualifier=None,
)
A peer that does not recognise the addressing it is offered answers the session
CONNECT with a REFUSE SPDU, which surfaces as IedSessionRefusedError:
try:
conn = await iec61850.IedConnection.connect("10.0.0.1:102", iso=iso)
except iec61850.IedSessionRefusedError as e:
# ISO 8327-1 reason code, transport-disconnect parameter, and the
# presentation provider-reason; each is None when the refusal omits it.
print(e.reason_code, e.transport_disconnect, e.provider_reason)
Log service
A journal is named by the LogRef of its log control block,
"<domain>/<LN>$<name>", not by the control block's own reference.
LOG_REF = "IED1LD0/LLN0$EventLog"
# One ReadJournal request. ``more_follows`` signals that the server stopped
# at the PDU size and the caller should resume.
query = iec61850.JournalQuery.by_time(start_ms, end_ms)
entries, more = await conn.query_journal(LOG_REF, query)
for e in entries:
print(e.time_ms, e.entry_id.hex(), len(e.variables))
# Every entry the selection covers, following ``more_follows``.
entries = await conn.query_journal_all(LOG_REF, query)
# Resume after the last seen entry.
cursor = entries[-1]
later = await conn.query_journal_all(
LOG_REF, iec61850.JournalQuery.starting_after(cursor.time_ms, cursor.entry_id)
)
JournalQuery carries every selection ReadJournal defines: a start
(start_time_ms or start_entry), a stop (end_time_ms or
max_entries), the variables to return, and after_entry as a
(time_ms, entry_id) pair; it raises ValueError for a combination the
service does not allow. query_journal_all keeps the selection on every
continuation, returns each entry once, none past end_time_ms and no more
than max_entries, and raises IedServiceError with
reason == "journal-not-advancing" when a server reports more entries but
sends none it has not sent before. query_journal_by_time(log_ref, start_ms, end_ms) and query_journal_after_entry(log_ref, time_ms, entry_id) remain as shorthands for one request.
JournalEntry.variables is a tuple of JournalEntryVariable(data_ref, value, reason_code). Values follow the same conversion rules as
IedConnection.read — scalars surface natively; bytes-like kinds
(BIT_STRING / OCTET_STRING / UTC_TIME / BINARY_TIME) as bytes;
composites as list.
Reporting
def on_report(report: iec61850.ClientReport) -> None:
print(report.rcb_reference, len(report.entries))
rcb = await conn.get_rcb_values("DemoIEDLD0/LLN0$RP$urcbMeas")
rcb.resv = True
rcb.rpt_ena = True
await conn.set_rcb_values(rcb, iec61850.RcbWriteMask.fields("resv", "rpt_ena"))
await conn.install_report_handler(rcb.object_reference, on_report)
dispatcher = conn.spawn_report_dispatcher(interval_ms=100)
try:
await asyncio.sleep(10)
finally:
await dispatcher.aclose()
ClientReport.entries holds one entry per data set member, keeping the last
value an earlier report carried for a member this one omits;
ClientReport.included holds one flag per member, set for the members this
report carries:
def on_report(report: iec61850.ClientReport) -> None:
for entry, carried in zip(report.entries, report.included, strict=True):
if carried:
print(entry.ref, entry.value, entry.reason)
A report larger than the PDU size the association negotiated arrives in
segments, each delivered to the handler as its own ClientReport with the
same sequence_number: sub_seq_num counts them from zero,
more_segments_follow is true on every segment but the last, and
included marks only the members of that segment. sub_seq_num is None
for an unsegmented report. The client does not reassemble segments.
Against a 0.4.0 server (including the one this package hosts):
RcbHandle.datasetandClientReport.dataset_nameread back with the logical device,"<LD>/<LN>$<name>"; a write may omit it.- Enabling an unreserved URCB reserves it for the writer; writing any other
attribute of an unreserved URCB does not reserve it. It stays reserved
after
rpt_ena=Falseuntil the holder writesresv=Falseor its association ends.resvcannot be written while the URCB is enabled. gi=Trueon a disabled control block fails withTemporarilyUnavailable.- Writing
rpt_id,dataset,opt_flds,buf_time,trigger_options,integrity_period,purge_buf,entry_idorresv_tmsof an enabled BRCB (as named inRcbWriteMask) fails withTemporarilyUnavailable.conf_revcountsDatSetchanges only, and after a purgeentry_idreads all zeros until the next report is sent. - The first report after every enable of a BRCB carries
buffer_overflowset, whicheverEntryIDthe client resynchronised from. - A member reports only the triggers its attribute declares (
dchg,qchg,dupdin the SCL); an update to the value an attribute already holds sends no data change, only a data update wheredupdis declared.
Control
spc = conn.create_control_object(
"IED1LD0/GGIO1.SPCSO1",
iec61850.ControlModel.SBO_ENHANCED,
)
spc.set_origin(iec61850.OriginValue(or_cat=3, or_ident=b"py-client"))
if await spc.select_with_value(True):
outcome = await spc.operate(True)
if not outcome:
print("operate failed:", outcome.add_cause)
if outcome.last_appl_error is not None:
print(outcome.last_appl_error.error, outcome.last_appl_error.ctl_num)
select, select_with_value, operate and cancel all return a
ControlOutcome, which is truthy exactly when the command succeeded.
add_cause is the ControlAddCause of a refusal and last_appl_error the
LastApplError the server reported with it (ctl_obj, error, or_cat,
or_ident, ctl_num, add_cause), or None when it sent none. The
enhanced-security models always report one; a normal-security server may
not, and a refused normal-security select (a read of SBO) carries no
cause at all, so it reads unknown. Add cause 24 is
ControlAddCause.BLOCKED_BY_COMMAND ("blocked-by-command");
ABORTION_BY_COMMAND remains an alias.
The value given to select_with_value, operate and cancel has to encode
as the ctlVal type of the object's common data class (IEC 61850-7-3
§7.5): a bool is sent as BOOLEAN, an int as a signed INTEGER and a
float as a single FLOAT32, and a tagged dict, the form write takes, as
the type it names.
| CDC | ctlVal |
Python value |
|---|---|---|
| SPC, DPC | BOOLEAN | bool |
| INC | INT32 | int |
| ENC | ENUMERATED | int |
| ISC | INT8 | int |
| BSC, BAC | CODED ENUM (stop, lower, higher) | {"type": "bit_string", "padding": 6, "data": b"\x40"} (lower) |
| APC | AnalogueValue (a structure) | {"type": "structure", "value": [{"type": "float32", "value": 1.5}]} |
A double point control takes a bool, like a single point one; an int
is sent as an INTEGER, which a server that checks the type refuses:
dpc = conn.create_control_object(
"IED1LD0/XCBR1.Pos", iec61850.ControlModel.SBO_ENHANCED
)
if await dpc.select_with_value(True): # True closes, False opens
outcome = await dpc.operate(True)
An APC's ctlVal is an AnalogueValue structure; send it as a tagged
structure whose elements follow the server's declaration, here f alone. A
bare float goes out as a lone FLOAT32, which a server that checks the type
refuses:
apc = conn.create_control_object(
"IED1LD0/GGIO1.AnOut1", iec61850.ControlModel.DIRECT_NORMAL
)
await apc.operate(
{"type": "structure", "value": [{"type": "float32", "value": 1.5}]}
)
GOOSE control blocks
A GOOSE control block is administered over MMS like any other control block; publishing and subscribing to the frames themselves is out of scope (see the PICS footnote 7).
gocb = "IED1LD0/LLN0.gcbStatus" # or "IED1LD0/LLN0$GO$gcbStatus"
values = await conn.get_gocb_values(gocb)
print(values.go_id, values.dat_set, values.conf_rev, values.dst_address)
await conn.set_gocb_values(gocb, go_id="BayStatus") # while GoEna is false
await conn.set_gocb_values(gocb, go_ena=True)
GoCBValues carries go_ena, go_id, dat_set (with the logical device),
conf_rev, nds_com, dst_address (a PhyComAddress of addr,
priority, vlan_id, app_id), min_time_ms, max_time_ms and
fixed_offs; a component the server omits reads None.
set_gocb_values writes only the arguments given, one attribute per
request. A 0.4.0 server refuses go_id and dat_set with
TemporarilyUnavailable while the block is enabled, and with
ObjectAccessDenied when it presents Edition 2.1.
A dst_address.addr of six zero octets means the block has no destination.
When the SCL holds a connected access point of the IED (a system
configuration), a server registers a GOOSE control block that has no <GSE>
(or a <GSE> without a MAC-Address) disabled, with that destination, and
refuses to enable it with TemporarilyUnavailable. Without a
<Communication> section for the IED, as in an ICD or a model spec, the block
keeps the default destination 01-0C-CD-01-00-00, APPID 0, and can be
enabled.
SCL / ICD / CID parser
Load an IED configuration document and inspect it as plain Python data:
scl = iec61850.load_scl("MyDevice.icd")
scl.ieds() # ['IED1']
doc = scl.to_dict()
doc["ieds"][0]["name"] # 'IED1'
doc["ieds"][0]["manufacturer"] # 'ACME'
ld = doc["ieds"][0]["access_points"][0]["server"]["logical_devices"][0]
ld["inst"] # 'GenericIO'
[ln["ln_class"] for ln in ld["logical_nodes"]] # ['LLN0', 'GGIO', ...]
# Resolve a logical-node's data objects via the DataTypeTemplates section:
ln_type_id = ld["logical_nodes"][0]["ln_type"]
ln_type = doc["data_type_templates"]["ln_node_types"][ln_type_id]
[do["name"] for do in ln_type["dos"]] # ['Mod', 'Beh', ...]
Both load_scl and parse_scl run the full two-stage pipeline (XML syntax
→ cross-element type-reference resolution). The returned dict mirrors the
SCL XML structure; type references stay as strings so callers can index
into doc["data_type_templates"] (ln_node_types / do_types /
da_types / enum_types) themselves.
For a stable text representation — useful as a regression / diff oracle — ask for the canonical summary of a single IED:
print(scl.summary("IED1"))
# IED name=IED1
# lds count=1
# LD inst=GenericIO ld_name=<None> lns=2
# LN class=LLN0 inst= prefix= dos=2 ...
# ...
Parse failures surface as SclError, a subclass of IedError, with
line, column, element_path, attribute, kind, and message
attributes set so the offending location is directly reachable:
try:
iec61850.load_scl("broken.icd")
except iec61850.SclError as e:
print(e.kind, "at", e.line, ":", e.column, "→", e.element_path, "@", e.attribute)
# e.g. UnresolvedTypeReference at 42 : 7 → SCL/IED[name="IED1"]/.../LN[...] @ lnType
Server hosting
Host an IED defined by an SCL / ICD / CID document as an MMS server.
IedServer.from_scl() builds the runtime model, bind() selects the
TCP address (port 0 requests an OS-assigned port), and async with
manages the lifecycle. While running, push value updates with the typed
update_* methods, addressing data attributes by
"<LD>/<LN>.<DO>.<DA>[.<sub>]*".
import asyncio
import iec61850
async def main():
server = iec61850.IedServer.from_scl("plant.icd", ied_name="IED1")
server.bind("0.0.0.0:0")
server.vendor = "ACME"
server.model_name = "Generic-IO"
server.max_connections = 5
async with server:
print("listening on", server.bound_addr)
while True:
server.update_bool("GenericIO/GGIO1.Ind1.stVal", True)
server.update_float32("GenericIO/MMXU1.TotW.mag.f", measure_power())
await asyncio.sleep(0.1)
asyncio.run(main())
Configuration setters (vendor, model_name, revision, max_connections,
the association limits below and set_edition) must be called before
start(); set_write_access_policy also works on a running server. vendor, model_name, revision,
max_connections and the association limits are write-only: reading one
raises AttributeError.
A hosted server raises these exceptions:
| Exception | When |
|---|---|
OSError |
start() cannot listen on the bound address, for example because the port is in use; from_scl cannot read its file |
RuntimeError |
a call in the wrong lifecycle state: a setter or register_* after start(), start() without bind() or twice, a running-only call (bound_addr, connection_count, stop(), batch(), log_value, …) while the server is not running, a second with_tls(), concurrent batch() blocks |
ValueError |
an argument that does not parse: a bind() address, a model spec, a token such as ctl_model |
KeyError |
a path, logical device or data set the model does not hold: an update_* path, a report control block whose data set is unknown at start(), a setting group handler for a logical device without an SGCB |
IedDataAccessError |
an update_* value that does not fit the attribute's type (e.g. update_float32 on a BOOLEAN) |
IedServerError |
a model or registration the server refuses at start() or register_from_model(), such as a duplicate data set or control block (reference names it) |
SclError |
an SCL document from_scl cannot parse or resolve |
While running, connection_count reports the open connections,
abort_connection(conn_id) aborts the one association a callback's conn_id
names and returns whether it found it, abort_all_connections() aborts every
association and returns how many it marked, and dynamic_dataset_count() counts the data sets clients have
created.
The server bounds what a client can hold open:
| Setter | Default | Effect |
|---|---|---|
association_setup_timeout_ms |
10 000 | a connection that has not associated by then is closed |
association_idle_timeout_ms |
300 000 | an association with no traffic for this long is aborted; None keeps it |
association_send_timeout_ms |
10 000 | a client that does not accept a PDU within this time is disconnected |
max_dynamic_datasets |
64 | data sets clients may create at run time, across all associations |
max_dynamic_datasets_per_association |
16 | run-time data sets one association may have created |
A report the client accepts counts as traffic, so a client that only receives reports stays associated.
The supported typed updates are update_bool, update_int32,
update_int64, update_uint32, update_float32, update_float64,
update_string, update_bit_string, and update_bit_string_from_int.
A BIT STRING such as a Dbpos or a Quality is updated from its octets and
padding, or from an int. The int form takes the declared size n of the
attribute and writes value as an n-bit number, most significant bit first:
bit 0 of the string, the first on the wire, carries 2**(n-1).
# Dbpos: 0 intermediate, 1 off, 2 on, 3 bad. 2 is stored as 0x80, padding 6.
server.update_bit_string_from_int("Bay/XCBR1.Pos.stVal", 2)
# The same value from its octets; the unused trailing bits are stored as zero.
server.update_bit_string("Bay/XCBR1.Pos.stVal", bytes([0x80]), 6)
The bit count has to fit the declared size, as a remote Write must: exactly
two bits for a Dbpos, one to thirteen for a Quality. A mismatch raises
IedDataAccessError and leaves the attribute unchanged.
An update raises only the trigger options the attribute declares: a changed
value raises a data change for dchg and a quality change for qchg, and
every update raises a data update for dupd. Writing the value an attribute
already holds sends no data change. The sub-attributes of a constructed
attribute take its trigger options, so mag.f triggers on what mag
declares. A value a client writes raises the same triggers.
Arrays
An attribute or sub-data object declared with count is an array. A client
reads and writes an element by index ("LD/LN.DO.da(2)"); the server
updates the whole array in one step:
server.update_array("LD/GGIO1.Arr.stVal", [True, False, True])
update_array takes one item per element, in index order; an element of a
constructed type is a list in model order or a dict keyed by sub-attribute
name. The shape is checked before any element changes, and the changes go
out as one batch, so a report control block without a buffer time sends one
report for the whole array. An on_read handler on an array returns a list
of the same length, and an on_write handler on an array receives the whole
array when a client writes one element.
Communication addressing
The SCL <Communication> section is read into the model and is available
before and after start():
[ap] = server.connected_access_point("AP1")
ap["sub_network"], ap["address"]["ip"], ap["address"]["parameters"]["MMS-Port"]
gse = server.gse_address("LD0", "gcbStatus") # None when there is no <GSE>
gse["mac_address"], gse["app_id"], gse["vlan_id"], gse["vlan_priority"]
gse["min_time_ms"], gse["max_time_ms"]
server.smv_address("LD0", "MSVCB01") # an <SMV> address, or None
Each address carries every <P> under parameters (type to text) and the
typed mac_address (6 bytes), app_id, vlan_id, vlan_priority and ip,
None when absent. register_from_model() sets the DstAddress, MinTime
and MaxTime of a GOOSE control block from its <GSE>; a server hosted from
Python sends no GOOSE frames (footnote 7). A <P> value written another
way than the schema form of its type (a one-digit VLAN-ID, a lower-case MAC
address, an AP title or selector with white space) is read as written, with
a warning. A value that cannot be read still loads: it stays under
parameters, its typed key reads None, and register_from_model()
registers the GOOSE control block it addresses without a destination, with a
warning. A connected access point of the loaded IED that names an access
point or control block the IED does not declare raises SclError; a
<ConnectedAP> of an IED the file does not declare, and the other references
of the section that name nothing, are skipped with a warning.
Registering what the model declares
Loading SCL or a model spec builds the model; the control blocks it declares
are served only once they are registered. register_from_model() registers
every data set, report control block instance, GOOSE control block, log
control block and controllable data object of the model:
server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1")
server.bind("0.0.0.0:102")
server.register_from_model() # queued; runs at start()
async with server:
...
Queued before start(), it runs after every explicit add_dataset /
register_urcb / register_brcb / register_log_control / on_control
registration and before the server accepts connections. Called while
running, it registers at once and returns the counts (data_sets, urcbs,
brcbs, gocbs, lcbs, sgcbs, control_objects). A report control
block declared with RptEnabled max="N" is registered once per instance,
named <name>01 to <name>NN when indexed. A data set or control block
registered under the same reference already raises IedServerError with
reference; a control object registered by on_control keeps its handlers.
Setting group control blocks are served either way.
Edition and write access
set_edition("ed1" | "ed2" | "ed2.1") selects the edition the server
presents; "ed2" is the default and "ed1" behaves as "ed2". The only
difference is that under "ed2.1" a client may not write the GoID and
DatSet of a GOOSE control block.
set_write_access_policy(fc, allow) allows or refuses remote writes under
"DC", "CF", "SP", "SV", "SE" or "BL"; SP, SV and SE are
allowed by default. A refused write fails with ObjectAccessDenied before
any on_write handler runs. On a running server a change applies to every
write that arrives afterwards, on associations already open as well.
write_access_allowed(fc) reports the policy.
Association authentication
set_authenticator(callable) installs a callable that decides on every
association request; set_authenticator(None) removes it, and without one
every association is accepted. It receives a mapping with peer,
calling_ap_title, calling_ae_qualifier, called_ap_title,
called_ae_qualifier, mechanism ("none", "password", "certificate"
or "other") and password (bytes or None), and returns None or
True to accept, False to refuse with authentication-failure, or the
name or code of an acse-service-user diagnostic that refuses the calling
identity or the credentials (3 to 6: calling AP-title, AP-invocation
identifier, AE-qualifier or AE-invocation identifier not recognized; 11 to
14: authentication mechanism name not recognized or required,
authentication failure, authentication required) to refuse with that
diagnostic. Any other value, including any other diagnostic such as 0
(null), an unknown name, or a raised exception refuses with
authentication-failure. The refused client receives a Session REFUSE whose
AARE carries the diagnostic and an Initiate-ErrorPDU with access
object-access-denied; this package's client raises IedAuthenticationError
for diagnostics 3 to 6 and 11 to 14, so every refusal by an authenticator
reaches it as that exception.
def authenticate(request: dict) -> bool | str | None:
if request["calling_ap_title"] not in ALLOWED_AP_TITLES:
return "calling-AP-title-not-recognized"
return request["password"] == b"s3cret"
server.set_authenticator(authenticate)
The server calls the callable while the association is set up, on a thread
of its bounded blocking pool, not on a runtime worker (as it calls the other
Python callbacks, see Read / write callbacks). A
wait that releases the GIL (threading.Event.wait, socket I/O,
time.sleep) does not hold up other associations, though while the pool is
full further callbacks queue; computation that holds the GIL stalls every
Python callback of the process. Keep it short. Installed before
start(), it is in place before the first association; on a running server
it applies to the associations requested afterwards. A password reaches it in
clear unless the association runs over TLS.
Server-side TLS
with_tls() wraps the listener in an IEC 62351-3 TLS acceptor. Only
valid before start(); calling it more than once raises RuntimeError.
server.with_tls(
server_cert_pem=open("server.crt", "rb").read(),
server_key_pem=open("server.key", "rb").read(),
)
Mutual TLS adds a CA bundle for client-chain validation and, optionally, a pinned peer list (only a client whose leaf certificate is byte for byte the DER of one of the known peers is accepted; the whole certificate is compared, not its public key, so a renewed certificate has to be added to the list):
server.with_tls(
server_cert_pem=server_cert,
server_key_pem=server_key,
client_ca_pem=ca_pem,
allow_only_known_peers=True,
known_peer_pems=[peer1_pem, peer2_pem],
crl_pems=[crl_pem],
)
Defaults: TLS 1.2 - 1.3, the IEC 62351-3 cipher suites listed under
TLS, time validation on, session resumption on (TLS 1.2 session
IDs; the server sends no TLS 1.3 session ticket, so a TLS 1.3 session does
not resume), no client-cert pinning; a client certificate
chain is always validated against client_ca_pem. min_tls_version and
max_tls_version accept "tls1.2" / "tls1.3".
Read / write callbacks
Register per-attribute callbacks to override cached reads or intercept
incoming writes. Both on_read and on_write may be called before
start() (queued and installed at startup) or while the server is running
(installed immediately). Re-registering the same path replaces the
previous callback.
def measure_indication(path: str) -> bool:
# Sampled from physical I/O on every client read.
return read_io(path)
def validate_setpoint(path: str, value: int) -> bool:
if value < 0 or value > 100:
err = iec61850.IedDataAccessError("setpoint out of range")
err.code = "ObjectValueInvalid"
raise err
apply_setpoint(value)
return True # also store value in the server-side cache
server.on_read("GenericIO/GGIO1.Ind1.stVal", measure_indication)
server.on_write("GenericIO/GGIO1.SetPt1.setVal", validate_setpoint)
on_read return values:
| Return | Behavior |
|---|---|
| any scalar | the value is returned to the client |
| tagged dict | the value is returned to the client |
None |
fall through to the cached value |
| raises | read fails with IedDataAccessError |
A tagged dict takes the form from_model_spec accepts for value, so a
callback can serve a BIT STRING such as Dbpos:
{"type": "bit_string", "padding": 6, "data": b"\x80"} reads as the on
state. A dict that does not convert fails the read with TypeInconsistent
and prints the reason through the standard exception hook.
on_write return values:
| Return | Behavior |
|---|---|
True |
accept; cache is updated with the incoming value |
False / None |
accept; cache is not updated (you manage it) |
| raises | reject; client sees IedDataAccessError |
Set a code attribute on the raised exception to control the reported
DataAccessError variant — "HardwareFault", "TemporarilyUnavailable",
"ObjectAccessDenied", "ObjectValueInvalid", etc. Without code the
server reports ObjectAccessDenied.
A handler decides every request that covers its attribute: a read of the
attribute itself, of a node above it (its data object, its logical node, a
functional-constraint group), of a node below it, and of a data set holding
it; a write to the attribute or to any node above or below it. A handler on
a data object or constructed attribute returns its value as a list in model
order. The server holds no lock while a handler runs, so it may call the
update_* methods.
The Python callbacks of a hosted server (read, write, control check, a
synchronous control operate or wait, setting group and authenticator)
run on a thread of the server's bounded blocking pool, not on a runtime
worker, and take the GIL there; an async def operate or wait is called
there too and its coroutine then runs on the event loop that started the
server. A blocking wait in one does not hold up other associations, though
while the pool is full further callbacks queue; computation that holds the
GIL stalls every Python callback. Successive calls may run on different threads, so
threading.local state does not carry over, and callbacks of different
associations may interleave.
Pass with_context=True to receive the request as well:
def on_read(path: str, ctx: dict) -> object:
# ctx: {"path": "GGIO1$ST$Ind1$stVal", "fc": "ST", "conn_id": 3,
# "requested": "GGIO1$ST$Ind1"}
return read_io(path)
server.on_read("GenericIO/GGIO1.Ind1.stVal", on_read, with_context=True)
server.on_write("GenericIO/GGIO1.SetPt1.setVal",
lambda path, value, ctx: True, with_context=True)
path is the canonical path the handler is registered against and
requested the path the client named.
Control callbacks
on_control binds the server-side execution of a control object. Address
it at the DO ("<LD>/<LN>.<DO>") and declare which IEC 61850 control
model the DO uses. Up to three callbacks may be supplied, and they differ in
how they refuse a command:
| Callback | Kind | Runs | Refuses the command when it |
|---|---|---|---|
check |
sync only | on Select (ctl_val is None), SelectWithValue and Operate, first |
raises; its return value is ignored |
wait |
sync or async |
on Operate, after check and before the Operate response, under every control model |
raises, or returns False |
operate |
sync or async |
on Operate, after a positive Operate response | raises, or returns False |
checkis static validation: interlocks, mode, permissions. It is called as a plain function, so anasync defcheck is never awaited and never refuses anything.waitis the dynamic check, the WaitForExecution state of IEC 61850-7-2 (for example waiting for a synchro-check confirmation). Its outcome decides the Operate response.operateexecutes the command. An Operate on an object registered without one is refused withNotSupported.
A raised exception refuses with the add cause it carries (see below); a
False return refuses with Unknown. None, True and any other return
value accept.
operate runs only after the client has received a positive Operate
response. Under the enhanced-security models its failure reaches the client
as a negative CommandTermination carrying the add cause. Under the
normal-security models it is not reported to the client at all, so refuse
a command from check or wait instead.
Each callback receives (path, ctl_val, action). action is a dict with
ctl_num, test, synchro_check, interlock_check, is_select, t
(the request timestamp as eight UTC_TIME octets), conn_id (the
association that issued it), and origin (a sub-dict with or_cat and
or_ident).
The server refuses a time-activated operate (an Oper with an operTm)
with NotSupported.
async def operate(path: str, value: bool, action: dict) -> None:
if action["test"]:
return # test command — no I/O
await drive_breaker(path, value)
def check(_path: str, _value: bool, _action: dict) -> None:
if interlock_blocked():
err = iec61850.IedControlError("interlocked")
err.add_cause = "BlockedByInterlocking"
raise err
server.on_control(
"GenericIO/GGIO1.SPCSO1",
ctl_model="direct-normal",
check=check,
operate=operate,
)
ctl_model is one of "status-only", "direct-normal", "sbo-normal",
"direct-enhanced", "sbo-enhanced". For SBO models the optional
sbo_timeout_ms (default 30000) and sbo_class ("operate-once" or
"operate-many", default "operate-once") configure the select-phase
behavior. oper_timeout_ms (default 0, none) ends a command that executes
for longer with TimeLimitOver. A ctlModel, sboTimeout, sboClass or
operTimeout the model declares takes precedence over these arguments, so
declare the control model in the SCL rather than only passing it here. The
server maintains stSeld itself.
Raise an exception from any callback to reject the command. Set
add_cause on the exception to the variant name (e.g.
"BlockedByInterlocking", "BlockedByProcess", "NotSupported") or
its numeric MMS code; absence falls back to "Unknown".
Datasets and unbuffered reporting
Declare a server-side dataset and bind it to an Unbuffered Report Control
Block (URCB) before start(). The same client APIs (get_rcb_values,
set_rcb_values, install_report_handler) consume reports from the URCB
once the server is running.
The server stores log entries and delivers reports without calling Python
code. An update_* that arrives while another thread's update is being
delivered waits for that delivery, so triggers are delivered in the order the
values were stored; a value overwritten within one client write request is
not delivered on its own.
server.add_dataset(
"GGIO1$ds1",
[
"GenericIO/GGIO1.Ind1.stVal",
"GenericIO/GGIO1.AnIn1.mag.f",
],
)
server.register_urcb(
"GenericIO/LLN0.urcb01",
dataset="GGIO1$ds1",
trg_ops=["data_changed", "gi"],
opt_flds=["seq_num", "time_stamp", "reason", "data_set"],
buf_tm_ms=50,
)
Dataset names follow the IEC 61850 convention "<LN>$<dsName>". Every
entry in a dataset must belong to the same logical device. register_urcb
accepts rpt_id (defaults to "<domain>/<LN>$RP$<rcb_name>"),
conf_rev, trg_ops, opt_flds, buf_tm_ms, and intg_pd_ms.
Trigger options: "data_changed", "quality_changed", "data_update",
"integrity", "gi", plus the aliases "all" and "none".
Optional fields: "seq_num", "time_stamp", "reason", "data_set",
"data_reference", "conf_rev", "buffer_overflow", "entry_id". An
unbuffered control block has no buffer and no EntryID (IEC 61850-7-2
§17.2.4), so the server clears buffer_overflow and entry_id from its
reports.
Datasets without a URCB are still reachable via get_data_set_values.
A report carries only the reasons the control block's TrgOps enable, for
the triggers each member's attribute declares: an SCL attribute without
dchg="true" (or qchg, dupd) sends no report on that trigger. A data
object or constructed attribute member is included whole when any attribute
beneath it triggers. A client reads DatSet back as
"<LD>/<LN>$<name>".
Buffered reporting (BRCB)
register_brcb mirrors register_urcb but binds the dataset to a
Buffered Report Control Block ($BR$ MMS path). Reports are held in a
per-RCB ring buffer until a client connects, so transient disconnects
do not lose updates.
server.register_brcb(
"GenericIO/LLN0.brcb01",
dataset="GGIO1$ds1",
trg_ops=["data_changed", "gi"],
opt_flds=[
"seq_num", "time_stamp", "reason", "data_set",
"buffer_overflow", "entry_id",
],
buf_tm_ms=50,
buffer_capacity=128,
)
A BRCB sends buffer_overflow and entry_id when they are selected
(IEC 61850-7-2 §17.2.2.8); a URCB clears them. Additional knobs:
buffer_capacity(default64) — entry-count ring size; the buffer evicts oldest entries when full and surfaces overflow through thebuffer_overflowfield on the next report. The first report after every enable also carriesbuffer_overflowset.with_resv_tms(defaultTrue) — expose the Edition 2+ResvTmsfield for client reservation.with_owner(defaultFalse) — expose the Edition 2+Ownerfield.
The same dataset can back both a URCB and a BRCB; client-side APIs
(get_rcb_values, set_rcb_values, install_report_handler,
ReportDispatcher) handle both transparently — RcbHandle.is_buffered
discriminates them.
Logging (LCB)
register_log_control declares a Log Control Block ($LG$ MMS path).
Each block backs onto an in-memory journal (InMemoryLogStorage), which
can be unbounded (default) or capped to a fixed entry count (oldest
entries are evicted on overflow). Clients name the journal by the block's
log_ref and pull it over MMS ReadJournal with query_journal /
query_journal_all.
server.add_dataset("LLN0$evlogds", ["GenericIO/GGIO1.Ind1.stVal"])
server.register_log_control(
"GenericIO/LLN0.lcb01",
dataset="LLN0$evlogds",
log_ref="IED1GenericIO/LLN0$EventLog",
trg_ops=["data_changed", "integrity"],
intg_pd_ms=60_000,
storage_capacity=1000,
)
async with server:
server.update_bool("GenericIO/GGIO1.Ind1.stVal", True) # logged
server.log_value(
"GenericIO/LLN0.lcb01",
data_ref="IED1GenericIO/GGIO1$ST$Ind2$stVal",
value=True,
reason_code=0x02, # bit 1 = data_changed
)
The server records the journal itself: an update of a member of the
block's data set (registered with add_dataset or register_from_model)
writes an entry when the block's trg_ops enable a reason the update
raises — data change, quality change or data update — and integrity writes
one entry holding the whole data set every intg_pd_ms. General
interrogation writes none. Updates made inside batch() write one entry per
block. log_value adds an entry of the application's own, for example for
a value outside the data set or with a chosen timestamp, and returns its
8-byte entry id (as an int), or None when the block's LogEna is
disabled. Toggle the enable state at runtime with set_log_ena(path, on).
Setting groups (SGCB)
A Setting Group Control Block is declared in SCL on <LN0>:
<LN0 lnClass="LLN0" inst="" lnType="LLN0_0">
<SettingControl numOfSGs="3" actSG="1" resvTms="60"/>
</LN0>
The server tracks ActSG / EditSG / ConfirmEditSG state, enforces the
single-client edit-session lock, and times out abandoned reservations.
Python applications opt into the three veto / commit points per LD.
on_act_sg(new_sg, conn_id), on_edit_sg(new_sg, conn_id) and
on_confirm(edit_sg, conn_id) all return bool | None. None or True
accepts the request. False, any other return value, or a raised exception
refuses it with ObjectAccessDenied: the client's write raises
IedDataAccessError with code == 3. A refused confirmation commits nothing
and leaves the edit session open. on_confirm runs before the staged FC=SE
values are committed, so it is where an application persists them.
def on_act_sg(new_sg: int, conn_id: int) -> bool:
return new_sg in allowed_sgs # return False → ObjectAccessDenied
def on_confirm(edit_sg: int, conn_id: int) -> None:
persist_pending_settings(edit_sg) # None accepts; False refuses
server.register_setting_group_handler(
"GenericIO",
on_act_sg=on_act_sg,
on_confirm=on_confirm,
)
get_setting_group_info(ld_inst) returns the live snapshot
(num_of_sg / act_sg / edit_sg / cnf_edit / last_act_tm_ms /
resv_tms_s). force_active_setting_group(ld_inst, sg) switches the
active group without consulting the callback — intended for startup
state restoration. Calling register_setting_group_handler again at
runtime atomically replaces the previous handler.
The server holds the values of every group. SelectActiveSG loads the values of the new group into the FC=SG attributes, SelectEditSG loads the edited group into FC=SE, and ConfirmEditSGValues stores FC=SE back into the group (and into FC=SG when it is the active one). Read or replace a group's value from the application with:
server.get_setting_group_value("GenericIO/PTOC1.StrVal.setMag.f", 2)
server.set_setting_group_value("GenericIO/PTOC1.StrVal.setMag.f", 2, 1.25)
Replacing a value of the active group updates the served attribute too; a
value of another group takes effect when that group is activated. In SCL a
setting carries one <Val sGroup="n"> per group.
Clients drive SGCB through the regular write API on the special MMS
path. ActSG and EditSG are INT8U, so write them as a tagged unsigned
value (or with write_uint32); a plain Python int is sent as a signed
MMS INTEGER, which a server that checks the declared type refuses:
group = {"type": "uint", "value": 2}
await conn.write("IED1GenericIO/LLN0.SGCB.ActSG", FC.SP, group) # SelectActiveSG
await conn.write("IED1GenericIO/LLN0.SGCB.EditSG", FC.SP, group) # open edit
await conn.write("IED1GenericIO/LLN0.SGCB.CnfEdit", FC.SP, True) # commit
The server this package hosts also accepts a non-negative INTEGER there.
Building a server from a model dict (no SCL)
When the IED schema is generated in Python — code-driven test rigs,
dynamic device skeletons, or runtimes that prefer dict-driven
configuration over XML — from_model_spec consumes a declarative
spec dict that maps onto the same model the SCL parser produces. The
RCB / LCB / SGCB declarations land in the model exactly as SCL-derived ones
would: the SGCB is served on its own, and register_from_model() registers
the data sets, RCBs and LCBs. Every callback and register_* method works
against the same "<LD>/<LN>.<DO>[.<DA>]*" paths.
spec = {
"ied_name": "IED1",
"lds": [{
"inst": "GenericIO",
"lns": [
{
"lln0": True,
"dos": [{
"name": "Mod",
"das": [
{"name": "stVal", "fc": "ST", "type": "Enumerated",
"trg_ops": ["data_changed"],
"value": {"type": "int", "value": 1}},
{"name": "q", "fc": "ST", "type": "Quality"},
{"name": "t", "fc": "ST", "type": "Timestamp"},
],
}],
"sgcb": {"num_of_sg": 3, "act_sg": 1},
},
{
"class": "GGIO", "inst": "1",
"dos": [{
"name": "Ind1",
"das": [
{"name": "stVal", "fc": "ST", "type": "Boolean"},
{"name": "q", "fc": "ST", "type": "Quality"},
{"name": "t", "fc": "ST", "type": "Timestamp"},
],
}],
"datasets": [{
"name": "Events", "entries": [
{"ln_name": "GGIO1", "fc": "ST",
"do_path": ["Ind1", "stVal"]},
],
}],
"rcbs": [{
"name": "Events01", "buffered": False,
"dataset_ref": "Events", "conf_rev": 1,
"trg_ops": ["data_changed", "integrity"],
"opt_flds": ["seq_num", "time_stamp", "reason"],
"buf_tm_ms": 100,
}],
},
],
}],
}
server = iec61850.IedServer.from_model_spec(spec)
server.bind("127.0.0.1:0")
async with server:
...
type takes one of these tokens, spelled exactly so:
| Group | Tokens |
|---|---|
| Boolean | "Boolean" |
| Signed integers | "Int8", "Int16", "Int24", "Int32", "Int64", "Int128" |
| Unsigned | "Int8U", "Int16U", "Int24U", "Int32U" |
| Floating point | "Float32", "Float64" |
| Enumerations | "Enumerated", "CodedEnum" (two bits, such as a Dbpos) |
| Strings | "VisibleString", "OctetString", "UnicodeString255" |
| Bit strings | "GenericBitString", "Quality", "Check", "OptFlds", "TrgOpsBits", "SvOptFlds", "LogOptFlds" |
| Time | "Timestamp", "EntryTime" |
| Other | "PhyComAddr", "Currency", "Constructed" |
"VisibleString" and "OctetString" take a maximum length in bytes and
"GenericBitString" one in bits, through the object form
{"type": "OctetString", "max_len": 64}; without it they default to 64,
64 and 8. Any other spelling raises ValueError, and so does an SCL
bType name (BOOLEAN, INT32, Dbpos, VisString64, …), which is not a
token. The SCL types translate as follows:
SCL bType |
type |
|---|---|
BOOLEAN, INT8 … INT128, INT8U … INT32U, FLOAT32, FLOAT64 |
the token of the same name in the case above ("Boolean", "Int8", "Int8U", "Float32", …) |
Enum |
"Enumerated" |
Dbpos, Tcmd |
"CodedEnum" |
VisString32 … VisString255 |
{"type": "VisibleString", "max_len": n} |
ObjRef |
{"type": "VisibleString", "max_len": 129} |
Octet6, Octet16, Octet64 |
{"type": "OctetString", "max_len": n} |
EntryID |
{"type": "OctetString", "max_len": 8} |
Unicode255 |
"UnicodeString255" |
TrgOps |
"TrgOpsBits" |
Struct |
an entry under "constructed_das" (below) |
Quality, Timestamp, Check, EntryTime, PhyComAddr, Currency, OptFlds, SvOptFlds, LogOptFlds |
the same name |
value is a tagged dict ({"type": "int", "value": 1}, `{"type": |
|
| "bit_string", "padding": 3, "data": b"\x00\x00"}`, …) or | |
{"type": "default"} for the type's zero. Constructed (SDA-bearing) |
|
DAs go under "constructed_das" with a "children" list; nested DOs |
|
go under "sub_dos". The underlying IedModelBuilder enforces all |
|
| invariants (LLN0 first, SGCB only on LLN0, dataset entries resolve to | |
real LN/DO) and surfaces violations as ValueError. |
Batch updates
server.batch() returns a synchronous context manager that holds the
server's data-model lock for the duration of the with block. The
triggers of the updates made inside it are raised together when the block
exits: a report control block without a buffer time sends one report, a
buffered one stores one entry, and a log control block writes one entry.
Buffer-time expiry and integrity and general-interrogation reports wait
until the block exits, so keep it short. Client reads are not held back.
Concurrent batches raise RuntimeError rather than deadlocking, so callers
can choose to retry or fail fast.
with server.batch():
server.update_bool("GenericIO/GGIO1.Ind1.stVal", True)
server.update_float32("GenericIO/GGIO1.AnIn1.mag.f", 12.5)
server.update_int32("GenericIO/GGIO1.SetPt1.setVal", 7)
Error handling
try:
conn = await iec61850.IedConnection.connect("10.0.0.1:102", timeout_ms=2000)
except iec61850.IedTimeoutError as e:
... # connection timed out after e.timeout_ms
except iec61850.IedSessionRefusedError:
... # peer refused the association at the session layer
except iec61850.IedTlsError as e:
... # TLS handshake failed; e.kind says why
except iec61850.IedConnectionError as e:
... # TCP / OSI stack failure; e.reason says which
except iec61850.IedError:
... # catch-all base for any IEC 61850 error
Each exception carries attributes a caller can branch on; an attribute that
does not apply reads None.
| Exception | Attributes |
|---|---|
IedConnectionError |
reason ("connection-lost", "released-by-peer", "transport", "associate-failed", "initiate-failed"), kind and detail of a transport failure, code of a refused Initiate |
IedSessionRefusedError |
reason_code, transport_disconnect, provider_reason |
IedAuthenticationError |
diagnostic and diagnostic_name of the refusing AARE; reason is "authentication-rejected" |
IedTlsError |
kind ("verification", "alert_received", "version_unsupported", "cipher_unsupported", "timeout", "io", "other"), message |
IedTimeoutError |
timeout_ms |
IedServiceError |
reason ("service-error", "reject", "conclude-rejected", "outstanding-limit", "pdu-too-large", "name-list-limit", "name-list-not-advancing", "journal-not-advancing"), error_class, code, reject_type, number_deleted, pdu_size, max_size, limit |
IedDataAccessError |
code, the MMS DataAccessError value |
IedServerError |
reference of a refused duplicate registration |
IedSessionRefusedError and IedTlsError derive from
IedConnectionError. IedTimeoutError derives from IedError only: a
request, connect or command-termination timeout is not caught by
except IedServiceError. A connection that drops after it was established
raises IedConnectionError (reason "connection-lost",
"released-by-peer" or "transport"), not IedServiceError.
reason == "transport" is an I/O failure other than a close, such as a
refused connection; a connection the peer resets or closes is
"connection-lost".
timeout_ms of connect and connect_tls bounds the TCP connection, the TLS
handshake (connect_tls) and the COTP handshake together. Running out of it
raises IedTimeoutError whose timeout_ms is the value given; running out of
it during the TLS handshake raises IedTlsError with kind == "timeout". The
Session, ACSE and MMS Initiate exchange that follows is bounded by
request_timeout_ms (5000 ms when not given), whose expiry raises
IedTimeoutError carrying that value.
Release notes
0.16.0
Tracks iec61850-rust v0.4.0.
Breaking changes
-
TlsConfig,IedConnection.connect_tlsandIedServer.with_tlslosechain_validation: the certificate chain is always validated. Drop the argument.# 0.15 tls = iec61850.TlsConfig(ca_pem=ca, chain_validation=True) # 0.16 tls = iec61850.TlsConfig(ca_pem=ca)
-
ControlObjectClient.select()returns aControlOutcomeinstead of abool. An outcome is truthy exactly when it succeeded, soif await ctl.select():keeps working; compare.successwhere the code tested identity.# 0.15 assert await ctl.select() is True # 0.16 assert (await ctl.select()).success
-
A
ControlOutcomeis truthy exactly when the command succeeded. In 0.15 it had no truth value of its own, soif await ctl.operate(v):andif await ctl.cancel(v):were always true; they now take the failure branch when the server refuses. Handle the refusal there, or drop the test where the code has to run either way.# 0.15: always entered if await ctl.operate(True): ... # 0.16: entered only on success outcome = await ctl.operate(True) if outcome: ... else: print(outcome.add_cause)
-
Add cause 24 reads as
"blocked-by-command"instead of"abortion-by-command".ControlAddCause.ABORTION_BY_COMMANDstays an alias ofBLOCKED_BY_COMMANDand the old token still parses, but code that compares the string no longer matches. Compare the enum member.# 0.15 if outcome.add_cause == "abortion-by-command": ... # 0.16 if outcome.add_cause is iec61850.ControlAddCause.BLOCKED_BY_COMMAND: ...
-
The
actiondict passed toon_controlcallbacks carriest(the request timestamp as eight UTC_TIME octets) andconn_idinstead ofctl_time_ms.# 0.15 when_ms = action["ctl_time_ms"] # 0.16 t_octets, conn = action["t"], action["conn_id"]
-
Client failures raise the exception class of their cause. The class hierarchy is unchanged (
IedTimeoutErrorderives fromIedErroronly, as before); what moves is which class a failure raises:Failure 0.15 0.16 A request times out IedServiceErrorIedTimeoutErrorA connect times out in the TCP or COTP stage IedConnectionErrorIedTimeoutErrorAn established connection is lost, released by the peer, or fails in transport IedServiceErrorIedConnectionErrorwithreason"connection-lost","released-by-peer"or"transport"The peer refuses the association for the calling identity or the credentials IedSessionRefusedErrorIedAuthenticationError(a subclass ofIedConnectionError, not ofIedSessionRefusedError)except IedServiceErrorno longer catches a request timeout or a lost connection,except IedConnectionErroraroundconnectno longer catches a connect timeout, andexcept IedSessionRefusedErrorno longer catches an authentication refusal. Catch the classes together, or branch onreason:# 0.15 except iec61850.IedServiceError: ... # also caught timeouts and disconnects # 0.16 except (iec61850.IedServiceError, iec61850.IedTimeoutError, iec61850.IedConnectionError): ... # or except iec61850.IedConnectionError as e: if e.reason in ("connection-lost", "released-by-peer", "transport"): ... # reconnect
-
The data sets, report, GOOSE and log control blocks and control objects a model declares are served only once registered. Call
register_from_model(), or keep the explicitadd_dataset/register_*/on_controlcalls. A report control block registered from the model is named per instance,<name>01when indexed.# 0.15 server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1") # 0.16 server = iec61850.IedServer.from_scl("plant.cid", ied_name="IED1") server.register_from_model()
-
A journal is named by the
LogRefof its log control block, not by the control block reference.# 0.15 await conn.query_journal_by_time("IED1LD0/LLN0$LG$lcb01", t0, t1) # 0.16 await conn.query_journal_by_time("IED1LD0/LLN0$EventLog", t0, t1)
-
A hosted server writes the journal itself for every member of an LCB's data set (data change, quality change, data update and integrity, as the block's
TrgOpsselect). Stop callinglog_valuefor those members, or each change is logged twice; register the data set so the block can record it.# 0.15 server.update_bool("LD0/GGIO1.Ind1.stVal", True) server.log_value("LD0/LLN0.lcb01", data_ref=ref, value=True) # 0.16 server.add_dataset("LLN0$dsStatus", ["LD0/GGIO1.Ind1.stVal"]) ... server.update_bool("LD0/GGIO1.Ind1.stVal", True) # logged
-
Under the normal-security control models a failing
operatecallback is no longer reported to the client. Refuse the command fromcheckorwait.# 0.15 server.on_control(path, ctl_model="direct-normal", operate=refuse_if_blocked) # 0.16 server.on_control(path, ctl_model="direct-normal", check=refuse_if_blocked, operate=operate)
-
A
ctlModel,sboTimeout,sboClassoroperTimeoutthe model declares takes precedence over the arguments ofon_control. Declare the control model in the SCL.<!-- 0.15: on_control(..., ctl_model="sbo-normal") overrode this --> <DAI name="ctlModel"><Val>direct-with-normal-security</Val></DAI> <!-- 0.16 --> <DAI name="ctlModel"><Val>sbo-with-normal-security</Val></DAI>
-
An attribute reports only the trigger options it declares. Declare
dchg(orqchg,dupd) on an SCL attribute that should report, and give a model-spec attribute that should report atrg_opslist; one without it raises none.<!-- 0.15 --> <DA name="stVal" fc="ST" bType="BOOLEAN"/> <!-- 0.16 --> <DA name="stVal" fc="ST" bType="BOOLEAN" dchg="true"/>
-
max_outstandingis limited to 65535. -
MmsValueandControlParamsare removed. No method returned or took either: a genericread()returns native values (list,bytes, ...), andControlObjectClienttakes its settings through its setters. Drop the imports.A value written as an
MmsValueis written as a native or tagged value:0.15 0.16 MmsValue.structure(...){"type": "structure", "value": [...]}MmsValue.array(...)a listMmsValue.octet_string(b)bytesEach
ControlParamsfield has a setter or an argument of its own:ControlParamsfield0.16 ctl_valthe argument of operate(value)testset_test(True)check_synchrocheckset_synchro_check(True)check_interlockset_interlock_check(True)origin_orcat,origin_oridentset_origin(OriginValue(or_cat=..., or_ident=...))operate_timeno replacement: a 0.4.0 server refuses an Opercarrying anoperTmwithNotSupported# 0.15 await ctl.operate(iec61850.ControlParams(ctl_val=True, test=True)) # never accepted # 0.16 ctl.set_test(True) await ctl.operate(True)
-
InclusionReason.application_triggeris removed. It was never set: the client decodes data change, quality change, data update, integrity and general interrogation. The ReasonCode bit it stood for, bit 6, is not used for reports by IEC 61850-8-1, so no report carries it and no capability is lost. Drop the reads. -
A TLS handshake that stalls past
timeout_msraisesIedTlsErrorwithkind == "timeout"(a subclass ofIedConnectionError) instead ofIedTimeoutError. Catch both aroundconnect_tls:try: conn = await IedConnection.connect_tls(addr, tls, "ied1", timeout_ms=3000) except (iec61850.IedTimeoutError, iec61850.IedTlsError) as e: ...
-
on_confirmcan refuse a confirmation. In 0.15 its return value was ignored and an exception was only reported, so the commit always went ahead. NowFalse, a return value other thanNoneor a bool, or an exception refuses the ConfirmEditSGValues with ObjectAccessDenied. A callback that raised to report a problem but still wants the commit must catch it, and one that returned a truthy non-bool must returnTrueorNone:def on_confirm(edit_sg: int, conn_id: int) -> None: try: persist(edit_sg) except OSError: log.exception("persisting setting group %d failed", edit_sg) # returning None accepts the confirmation
Added
-
IedConnection.get_server_identity()(MMS Identify) returns aServerIdentity;get_server_status(extended_derivation=False)(MMS Status) returns aServerStatus. -
JournalQueryandIedConnection.query_journal(log_ref, query), one ReadJournal request with any selection, andquery_journal_all, which followsmore_followsand returns each entry once. -
max_name_list_namesonconnect,connect_tlsandIec61850ClientConfigcaps the names one directory walk collects. -
ClientReport.included,sub_seq_numandmore_segments_follow. -
IedConnection.get_gocb_valuesandset_gocb_values, with theGoCBValuesandPhyComAddressdataclasses. -
ControlOutcome.last_appl_errorand theLastApplErrordataclass;ControlAddCause.BLOCKED_BY_COMMAND("blocked-by-command"), withABORTION_BY_COMMANDkept as an alias and its token still parsed. -
IedTlsError, a subclass ofIedConnectionError, for a failed TLS handshake, withkindandmessage; 0.15 raised a plainIedConnectionError, soexcept IedConnectionErrorstill catches it.IedConnectionError,IedServiceError,IedTimeoutError,IedDataAccessErrorandIedServerErrorcarry attributes naming the cause (see Error handling). -
IedServer.register_from_model(),update_array(path, values),set_edition(edition),get_setting_group_value(path, group),set_setting_group_value(path, group, value),set_write_access_policy(fc, allow),write_access_allowed(fc),abort_all_connections()anddynamic_dataset_count(). -
on_readandon_writetakewith_context=Trueto receive the request context (path,fc,conn_id,requested). -
on_controltakesoper_timeout_ms. -
Raw SCL type dictionaries carry
countandcount_reffor DA, BDA and SDO declarations, and a report control dictionary carriesindexed. -
from_model_specaccepts the attribute typesInt24,SvOptFldsandLogOptFlds, and a report control block in a spec takesindexedandmax_instances(not indexed unless asked, so its name is kept). -
IedServer.update_quality(path, quality)takes aQualityor the integerQuality.to_bits()returns, in the bit orderread_qualitydecodes;update_bit_string_from_intkeeps its most-significant-bit-first order. -
spawn_report_dispatchertakeson_error, called once with the exception that ends polling;ReportDispatcher.doneandexception()report it. -
IedConnection.read_timestamp_with_quality(ref, fc)returns the time and itsTimeQuality(leap_second_known,clock_failure,clock_not_synchronized,time_accuracy). -
IedServer.with_tlstakesrequire_client_auth: with aclient_ca_pem,Truerefuses a client that presents no certificate (by default such a client is admitted); without aclient_ca_pem,start()raisesValueError. -
AcsiClass.LOG_CONTROL("LCB") lists the log control blocks of a logical node;AcsiClass.LOGlists its logs (journals). -
IedServer.abort_connection(conn_id)aborts the one association named by theconn_idthe read, write and control callbacks receive. That connection sends an ACSE A-ABORT and closes, possibly after the call returns; every other association stays open. It returnsTruewhen it found the association andFalsefor an id naming no open association. RaisesRuntimeErrorwhen the server is not running. -
Tagged value
{"type": "structure", "value": [...]}: the components in order, each a plain value or a tagged dict, so structures nest.write,select_with_value,operateandcancelaccept it; an APC sends its AnalogueValuectlValas{"type": "structure", "value": [{"type": "float32", "value": 1.5}]}. A server control callback receives a structure as a list of its components. -
SclError.kindreads"UnresolvedDataSetReference"for a control block whosedatSetnames no data set of its logical node, which the SCL reader refuses. -
ACSE authentication:
IsoConnectionParameters.password(the ACSE password mechanism),IedAuthenticationErrorwithdiagnosticanddiagnostic_name, andIedServer.set_authenticator(callable), which decides on every association request from its AP-titles, AE-qualifiers and credentials. -
IedServer.set_write_access_policyalso applies on a running server, to the writes that arrive afterwards. -
IedServer.connected_access_point(ap_name),gse_address(ld_inst, cb_name)andsmv_address(ld_inst, cb_name)read the SCL<Communication>addressing from the model.
Fixed
connectandconnect_tlshonour atimeout_msabove 10 s. The attempt used to end after 10 s withtimeout_ms == 10000, and a shorter deadline raisedIedTimeoutErrorwithtimeout_msunset; it now carries the value given.timeout_msnow bounds the TCP connection, the TLS handshake and the COTP handshake only, no longer the Session, ACSE and MMS Initiate exchange that follows, whichrequest_timeout_msbounds (5000 ms when not given): a peer that answers COTP but not the session can holdconnect(timeout_ms=2000)for about 5 s.
Changed behavior (from iec61850-rust 0.4.0)
- Reports: a report larger than the negotiated PDU size arrives in
segments, each delivered separately; a report carries only the reasons
its control block's
TrgOpsenable; rewriting a value with itself sends no data change; the sub-attributes of a constructed attribute take its trigger options, somag.ftriggers on whatmagdeclares; a value a client writes raises the triggers its attribute declares. batch()raises the triggers of its updates as one batch on exit (one report without a buffer time, one log entry per log control block); periodic reports wait for it, and client reads are not held back.- Logging: data update and integrity are recorded as well as data and quality change; general interrogation writes no entry.
- Report control blocks:
DatSetreads back as"<LD>/<LN>$<name>"; enabling an unreserved URCB reserves it and disabling keeps the reservation untilresv=False; writing any other attribute of an unreserved URCB does not reserve it;gi=Trueon a disabled block, and configuration,purge_bufandentry_idwrites on an enabled BRCB, fail withTemporarilyUnavailable;conf_revcountsDatSetchanges only; the first report after every BRCB enable carriesBufOvfl; a full report channel no longer clearsRptEnaorResv. OwnerandResvTmsof an SCL-built control block exist only when its<ReportSettings>declaresowner="true"/resvTms="true"; an SCL<TrgOps>that omitsginow enables it.- Setting groups: the server holds the values of every group and
SelectActiveSG loads them into FC=SG; reading or writing FC=SE outside an
edit session answers
TemporarilyUnavailable. - Control: an
Operwith anoperTmis refused withNotSupported; a second select of a selected object fails; cancelling an idle direct control fails; a selection ends on its ownsboTimeout; the server maintainsstSeld; a refused operate reports the add cause the server sends instead ofunknown. - Arrays: an attribute or sub-data object declared with
countis an MMS array whose elements a client reads and writes by index; a read handler on an array returns a list of the element count. - Writes: a whole data object can be written; an integer out of range
answers
ObjectValueInvalidand a string or octet string of a wrong lengthTypeInconsistent; a Quality written with fewer bits reads back with 13. - Read and write handlers are asked for reads and writes above and below their own path, and for data set reads; a handler on a data object or constructed attribute answers in model order.
- Data sets: CreateDataSet takes data objects, constructed attributes and array elements as members, up to 1024 members and 4096 attributes, and a Write up to 4096 items; beyond, the error is resource capability-unavailable instead of access other. GetDataSetDirectory lists an array element member as the array with an alternate access.
- GI and integrity reports read a data object or constructed attribute written concurrently whole or not at all.
- A GoCB
DatSetreads as"<LD>/LLN0$<name>". - Python callbacks of a hosted server, a synchronous control
operateorwaitincluded, run on a thread of the server's blocking pool instead of a runtime worker: a blocking wait no longer holds up other associations,oper_timeout_msends a synchronousoperatethat runs past it (the callback finishes on its thread, its result ignored), successive calls may run on different threads, and callbacks of different associations may interleave. - Report and log triggers are delivered in the order the values were stored; a value overwritten within one client write request is not delivered on its own.
- A GOOSE control block registered from the model takes
DstAddress,MinTimeandMaxTimefrom its SCL<GSE>. When the SCL holds a connected access point of the IED, one without a<GSE>(or without aMAC-Address) is disabled, reads a destination of six zero octets, and cannot be enabled; without a<Communication>section it keeps the default destination and can be enabled. - The SCL
<Communication>section is read into the model. A<P>value written another way than its schema form is read with a warning; one that cannot be read loads, readsNonefrom its typed key, and leaves the GOOSE control block it addresses without a destination. A connected access point of the loaded IED naming what the IED does not declare raisesSclError; a<ConnectedAP>of an IED the file does not declare is skipped with a warning.Scl.summary()lists the connected access points and GSE / SMV addresses. - A client refused at Initiate raises
IedSessionRefusedError; one refused for its calling identity or credentials raisesIedAuthenticationError; a client refused by TLS gets the alert reason. - Directory walks keep the server's order without duplicates, and SCL
errors start with
"SCL error at"; data object members follow the DOType declaration order.
0.15.2
Tracks iec61850-rust v0.3.2. No API changes; the entries below are what a hosted server and a client now do differently.
ClientReport.entries: a member the report does not carry has every reason flag cleared. Its value is still the last one received, and an entry does not yet say whether the report carried it.- A buffered report control block enabled over MMS sends its reports to the
association that enabled it; enabled without an
EntryIDwrite, it starts from the oldest buffered entry. While it is enabled, a write from another association fails withObjectAccessDenied. When the association ends the block is disabled but keeps buffering, and a client that enables it again resumes after the last entry sent. - Integrity reports run for a report control block enabled over MMS whose
TrgOpsincludes integrity and whoseIntgPdis above zero, one everyIntgPdmilliseconds from the momentRptEnais written true. - A buffered report control block reserved with a positive
ResvTmsis held for the peer address that reserved it, forResvTmsseconds after that association ends; a write from any other address fails withObjectAccessDenied.ResvTmswritten as the 16-bit integerset_rcb_valuessends is accepted, and a value outside 0..=32767, or an unsigned report control block value wider than 32 bits, fails withobject-value-invalidinstead of being truncated. - A hosted server clears the unused trailing bits of a bit string it receives in a Write or SetDataSetValues, and of one it sends in a Read.
0.15.1
Tracks iec61850-rust v0.3.1.
IedServer.update_bit_string(path, data, padding)andIedServer.update_bit_string_from_int(path, value)— update a BIT STRING attribute such as aDbposor aQualityon a running server. The bit count has to fit the declared size of the attribute, exactly 2 for aDbposand 1 to 13 for aQuality, or the call raisesIedDataAccessErrorand the value stays.update_bit_string_from_intwrites an unsigned value as many bits wide as the declared size, most significant bit first, so aDbposof 2 is stored asb"\x80"with padding 6. Both trigger reports by the trigger options of the attribute.write_bit_stringand the taggedbit_stringvalue, wherever it is accepted, clear the unused trailing bits of the last octet before the value is sent or stored; they used to pass them through.- A remote Write, a SetDataSetValues member or an
on_readreturn value whose bit string does not fit the declared size of the attribute is refused: the Write fails withIedDataAccessErrorand leaves the value, and the read answers object-value-invalid. Only the type used to be checked, so an empty or 13-bit string could replace a two-bitDbpos. - A typed update of an attribute whose trigger options name
qchgand notdchg, such asq, triggers a quality change, so a report control block enabled fordchgalone no longer reports it; every update used to count as a data change.
0.15.0
Tracks iec61850-rust v0.3.0, whose server limits and checks change what a client and a hosted server observe; the entries below say how.
IedConnection.read_bit_stringandwrite_bit_string— typed access to a BIT STRING attribute as its data octets and padding count, most significant bit first: aDbposof on is(b"\x80", 6).- Tagged values —
on_readcallbacks,IedConnection.write,set_data_set_values,log_valueand the controlselect_with_value,operateandcancelaccept the{"type": ...}dictionariesfrom_model_spectakes, so a callback can answer aDbposread with{"type": "bit_string", "padding": 6, "data": b"\x80"}. IedServer.association_setup_timeout_ms,association_idle_timeout_ms,association_send_timeout_ms,max_dynamic_datasetsandmax_dynamic_datasets_per_association— settable beforestart().- A hosted server closes a connection that has not completed the MMS Initiate within 10 s of being accepted, aborts an association that neither sends nor receives a PDU for 300 s (a client that only receives reports stays connected), and closes a connection whose peer stops accepting PDUs for 10 s.
- A hosted server bounds the data sets clients create at run time, 64 in total
and 16 per association by default; past either limit CreateDataSet fails
with
IedServiceError. max_connectionscounts a connection from the moment it is accepted rather than from a completed Initiate.- SetDataSetValues applies the checks of a single write to every member: a
member under a read-only functional constraint, or one the
on_writehandler refuses, keeps its value and reports an error while the others are written. - URCB reservations and control selections are released when a connection
ends on a transport or protocol error as well as on a normal close, and a
setting-group edit session is released whenever its connection closes. BRCB
reservations still wait for
ResvTms, so a client can resume after reconnecting. - Read and Write requests are decoded under the nesting level the association negotiated. A reassembled TSDU past 73 192 bytes on the client, or past the negotiated PDU size plus 8 192 bytes on the server, closes the connection.
from_model_specrefuses a taggedbit_stringwhosepaddingis outside 0..=7, or non-zero with empty data. When anon_readreturn value cannot be converted, the reason is printed through the standard exception hook before the read fails withTypeInconsistent.
0.14.0
get_data_set_directory— the ACSI GetDataSetDirectory service, returning aDataSetDirectorywith each data set member as an IEC reference and its functional constraint.read_multiple— reads several object references with their functional constraints in a single MMS Read, in request order.get_data_set_valuesandread_multipleacceptstrict=False, returning aDataAccessFailurefor a failing entry in place of raisingIedDataAccessError.- Corrected the documented
iec61850.AcsiClassmember for listing a logical node's data set names:AcsiClass.DATASET. IsoConnectionParameters— the ISO addressing an association offers is now settable per connection throughIedConnection.connect(),connect_tls()andIec61850ClientConfig. The default selectors follow IEC 61850-8-1 (P-SEL00 00 00 01); the default AP-titles1.1.1.999and1.1.1.999.1with AE-qualifier 12 on both sides are the values IEDs customarily expect. Previous releases sent empty presentation selectors and no AP-title.IedSessionRefusedError— a session REFUSE SPDU now raises a dedicated subclass ofIedConnectionErrorcarryingreason_code,transport_disconnectandprovider_reason, instead of a generic connection failure.- The
ServiceErrorerrorClasssubcodes now follow the ISO 9506-2ServiceErrorASN.1 named numbers, and a Confirmed-ErrorPDU decodes per its[0] IMPLICITinvokeID tag. A server refusal now surfaces throughIedServiceErrorcarrying the standardErrorClassrather than a generic parse failure.
Who is using this?
The project is free to use in any setting, commercial deployments included, and
no registration is required. If you do run it somewhere, saying so helps other
readers judge where the implementation has been exercised. Add an entry to
ADOPTERS.md
by opening an issue with the
adopter template,
or open a GitHub Discussion if you would rather ask something first. Naming an
organization is optional; a description of the use case on its own is welcome.
License
MIT OR Apache-2.0, at your option. See
LICENSE-MIT
and
LICENSE-APACHE.
The upstream iec61850-rust
workspace is licensed under the same terms.
Metadata
Release files for iec61850 0.16.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Built distributions (wheels)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| iec61850-0.16.0-cp311-abi3-win_amd64.whl | CPython 3.11 | abi3 | Windows x86-64 | Details for iec61850-0.16.0-cp311-abi3-win_amd64.whl |
| iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl | CPython 3.11 | abi3 | Linux glibc 2.17+ x86-64 | Details for iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl |
Total release size: 7.5 MB
Release files / iec61850-0.16.0-cp311-abi3-win_amd64.whl
| Download URL | iec61850-0.16.0-cp311-abi3-win_amd64.whl |
|---|---|
| Size | 3.9 MB |
| Tags | CPython 3.11 Windows x86-64 abi3 |
|
SHA-256 checksum How to use checksums |
4a52e4795090e51a09da41a098ecf41e7bad0e906fd40c4bc4dd768640e5e50b
|
|
BLAKE2b-256 checksum How to use checksums |
9b11d5cc30fbe1871764898c955439590be7ef39c9e67ad6acc6fbcdbc680d0c
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.14.8
|
Release files / iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl
| Download URL | iec61850-0.16.0-cp311-abi3-manylinux2014_x86_64.manylinux_2_17_x86_64.whl |
|---|---|
| Size | 3.6 MB |
| Tags | CPython 3.11 Linux glibc 2.17+ x86-64 abi3 |
|
SHA-256 checksum How to use checksums |
d958b3dad9693e9e0b8a86a74313459675fafa080ae2b6fa3ccf714ee0a510c1
|
|
BLAKE2b-256 checksum How to use checksums |
c57414fdc1dddb15ab57ea0922ac069012418a510d117614268705fe3f4320f1
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.14.8
|
Security for iec61850 0.16.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
No provenance found
None of the files in this release were uploaded with provenance metadata.
A note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.