inverter-climate
Energy-aware climate coordination on Venus OS, using local D-Bus and Home Assistant. Google Nest remains connected through Home Assistant's existing integration; this package needs no Google credentials or additional Google project. A small supervised Python process runs beside the existing Venus services, including on Raspberry Pi 3. It reads system energy over D-Bus and exposes optional native thermostat controls.
The first use case is a gas furnace that consumes approximately 500 W of electricity while heating. Gas supplies the heat; electricity runs the furnace and associated equipment. This service can shift useful heating toward measured solar export. It does not measure gas usage, guarantee financial savings, or create a reason to burn additional gas just to consume electricity.
Observation mode is the default. Automatic preheating only writes when
mode = "active". Separately, [device] control_enabled = true enables explicit
user commands from the native Switch pane. Both forms of control are disabled
by default; enabling manual controls does not enable automatic preheating.
Connections
flowchart LR
subgraph Venus[Venus OS / Raspberry Pi]
DBus[Local system D-Bus] --> Climate[inverter-climate]
GUI[GUI v2 / VRM Remote Console] -->|Manual controls| Climate
end
Climate <-->|State and temperature setpoint| HA[Home Assistant]
HA <-->|Existing Nest integration| Google[Google Nest]
Google <--> Thermostat[Thermostat]
The native installation needs neither Kubernetes, Docker, inverter-gateway, Cloudflare Access nor Node-RED. Network requests run in this separate low-rate process, outside the inverter-control loop. HA still provides the Nest cloud connection. This third-party Venus OS package publishes a temperature device in Remote Console; HA owns the Nest protocol and authentication.
Native Venus OS installation
Install through SetupHelper/PackageManager: package inverter-climate, GitHub
user victron-venus, branch latest. This branch contains the verified
stable package with its locked pure-Python dependencies. The development main
branch is source code. Firmware provides Python 3.12+, D-Bus, GLib and
velib_python; no global Python installation or firmware replacement is needed.
A first installation stays disabled until configured. Put private config.toml
and environment files under /data/setupOptions/inverter-climate, readable
only by root. Use examples/venus.toml, select your actual
HA entity, complete PV paths and grid phases, and retain mode = "observe".
The environment contains only HA_BASE_URL and HA_TOKEN.
python3 -B /data/inverter-climate/payload/deploy/venus/install.py start
svstat /service/inverter-climate
cat /run/inverter-climate/status.json
PackageManager owns the source package at /data/inverter-climate; the running
payload and previous version are isolated under /data/inverter-climate-runtime.
Private configuration and the ownership journal survive package replacement.
Status and bounded logs live in /run (RAM). Stable observation does not rewrite
the journal every poll; ownership and command changes remain immediately durable.
See the SetupHelper lifecycle guide for archive installation, updating, uninstalling, rollback and migration from the original 0.2 native installation. Migrate that installation before PackageManager replaces its old source directory.
Device list and D-Bus publication
The native daemon publishes Inverter Climate as a supported Venus temperature
device, with TemperatureType = 3 (Room). The stock GUI shows the thermostat's
measured room temperature and device metadata. Its standard Switch pane can
also display a temperature slider and a Heating mode dropdown (Off / Heat).
These controls use Victron's Switchable Output API on the same temperature
service and work through GUI v2 and VRM Remote Console without GUI patches.
HA continues to provide the Nest connection.
The service name is com.victronenergy.temperature.inverter_climate_<identity>.
The suffix is a stable hash, not the private HA address or entity name. Local
settings persist the device instance and custom display name across upgrades.
The custom name and the explicitly enabled Switch pane controls are writable;
temperature and climate telemetry remain read-only. Upgrading does not enable
controls or change the device identity or its temperature history.
To enable manual controls, add control_enabled = true to the existing
[device] section of the private native configuration and restart the service.
Keep mode = "observe" when only manual control is wanted. GUI v2 1.2.40 provides
the supported controls; the classic GUI has no equivalent Switch pane.
The slider uses the thermostat's advertised limits and temperature step, with
automatic conversion between Celsius and Fahrenheit. Off hides the slider
when Nest has no target temperature, while the mode dropdown remains available
to select Heat. Manual requests run serially outside the D-Bus thread. D-Bus readback remains
the last HA observation; the stock GUI may briefly show a requested value while
waiting, which is not confirmation. Pending,
stale or unsupported controls are unavailable. The temperature device remains
visible while the thermostat is off.
The supported /Temperature path is in degrees Celsius. Read-only /Climate/*
extensions describe the target, HVAC mode/action, coordination state and
integration health. /Climate/EstimatedHeatingPower explicitly identifies the
500 W policy estimate. The device publishes no AC/DC power or energy counters,
so it cannot add that estimate to measured household consumption.
One dedicated GLib worker serves GUI requests and emits batched changes while HA requests run outside that event loop. Energy uses a separate persistent bus connection and one root system snapshot per observation, with service-owner checks around the read. No D-Bus subprocess is launched in the polling path.
Optional external gateway deployment
The previous external backend remains available for installations that want it. Requires Python 3.12+ and uv.
uv sync --frozen
cp examples/config.toml config.toml
cp .env.example .env
# Fill .env locally; never commit it. Use your actual climate entity in config.toml.
uv run --env-file .env inverter-climate --discover
uv run --env-file .env inverter-climate --config config.toml --once
uv run --env-file .env inverter-climate --config config.toml
--discover only reads Home Assistant. --once exits 1 on an integration error,
2 on configuration/state failure, and 0 on a completed observation. The persistent
service continues polling on transient upstream errors, recording the reason.
Both integrations are needed before a boost is eligible; unavailable energy is
never converted to zero or inferred from other readings.
Private environment variables:
HA_BASE_URL,HA_TOKEN: configured HA origin and long-lived access token.GATEWAY_BASE_URL,GATEWAY_READ_TOKEN: gateway origin and read-only token.CF_ACCESS_CLIENT_ID,CF_ACCESS_CLIENT_SECRET: optional Access service credentials.
Base URLs must be origins, optionally ending in /; proxy path prefixes are not
supported in this version. HTTPS certificate validation stays enabled, redirects
are rejected and environment proxies are ignored. HTTP is supported for a trusted
local network. Tokens are sent only to the explicitly configured origin. The same
TLS connection also checks every verified certificate, including its trust
anchor, against the documented public-key minimums.
Policy
All policy temperatures use °C. Actual HA temperatures/commands are converted
using /api/config's temperature unit. The default comfort band of 17–19 °C is an
example to review for your household, not a universal heating recommendation.
- Respect the existing thermostat target as the baseline. Only
heatmode,idle/heatingaction, no preset, and target-temperature capability qualify.off, cooling, heat/cool ranges, eco presets, and unavailable devices receive no new boost. The automatic policy never changes HVAC mode or switches furnace power. Explicit Switch pane commands can selectHeatorOffthrough HA. - Require a valid energy observation for solar, grid power, battery power and
state of charge. Native mode reads one coherent root snapshot from
com.victronenergy.system, checking the service owner around the read. Explicit grid phases must matchAc/Grid/NumberOfPhases; missing/null selected PV components invalidate the sample. Native freshness means a recent local service read, not proof of the age of a physical measurement. In gateway mode, the existing schema-v1 receipt freshness rules still apply. Positive grid power means import; negative means export. Positive battery power means charging. External deployments use the gateway energy contract. - Require at least 600 W of export for 180 seconds by default: 500 W estimated furnace draw plus 100 W margin, solar output at least 500 W, battery SoC at least 90%, and no battery discharge above the 50 W tolerance.
- Raise the existing target by up to 0.5 °C, bounded by the comfort ceiling and device limits/step. Do nothing if the room is already warm enough. A missing device step uses 0.5 °C or 1 °F; for Fahrenheit devices configure a boost delta of at least 5/9 °C (for example 0.6) to permit one native degree.
- Normally retain a boost for at least 15 minutes and at most 30. While already heating, its estimated 500 W is added back only when checking whether an existing boost can continue. This is an estimate, not a dedicated wattmeter.
- Restore the original target on expiry, loss of valid energy data, excessive grid import/battery discharge, low SoC, or the comfort ceiling. These release conditions can override the minimum boost duration. Restoring a setpoint is not direct burner switching; the thermostat retains its own cycle protection.
- Any observed external target/mode/preset change relinquishes ownership and suspends boosts for two hours. Completed restoration also starts a cooldown.
This first policy uses measured net export only. It does not count battery charging as spare power, estimate curtailed PV, infer whole-house consumption, or optimize tariffs/gas prices. A zero-export ESS may therefore never qualify even when additional solar generation could be available. These are deliberate limits for initial observation, to be improved with measured evidence.
Commands and recovery
Explicit Switch pane commands have a separate identity-bound journal beside the
ownership journal (state.json.manual with the default native paths). Only one
command is sent at a time. A manual request relinquishes a confirmed automatic
boost and starts the configured manual hold. An unresolved automatic command
temporarily blocks manual commands. An unresolved manual command blocks further
commands and automation across restarts, including when manual control has been
disabled. Fresh observations resolve its outcome; restarting never resends it.
Before a service call, re-read the thermostat and persist the exact command
intent atomically. A later observed setpoint confirms the command. A timeout or
ambiguous result is not retried; the journal retains the intent so late
confirmation can still be recognized. A command that never confirms is shown
as boost_unconfirmed_no_retry or restore_unconfirmed_no_retry and needs local
inspection before resetting the journal. Do not delete a journal blindly.
Manual changes made through Nest, HA, a schedule or another controller are all treated alike. HA/Nest has no compare-and-set operation; a change made between the final read and service call can race with it. A manual write of the same numeric target is also indistinguishable from our own confirmation. This is not a hardware safety controller or a replacement for the thermostat's protections.
The journal binds to the HA origin and entity and survives restarts. Corruption or an identity mismatch stops the service. A filesystem lock prevents two local instances sharing that journal. Operate exactly one active instance per thermostat; separate hosts/journals do not provide a distributed lock.
To stop active coordination cleanly, first stop the existing daemon/container
without deleting its journal or volume. A second process cannot acquire its lock.
Retain mode = "active" and run exactly one foreground release instance with
the same configuration, credentials and persistent state:
uv run --env-file .env inverter-climate --config config.toml --release
This releases only a still-owned boost and never begins another one. It exits once the journal is idle; after confirmed restoration, switch to observation mode before restarting your usual service. Switching directly to observe, terminating the process, losing HA/Google access, or powering off the host cannot guarantee immediate restoration. The thermostat continues its own current setpoint; restarting active mode reconciles the journal.
The status JSON contains observations, the last decision, and integration health.
Logs omit endpoint/entity identity and credentials. Keep the journal on private
persistent storage and status private; on Venus, status belongs in /run.
Do not publish household observations. Native stop/release commands are in the
native lifecycle guide.
Container and systemd
See deployment for Docker Compose and systemd examples.
The container runs as a non-root user; mount writable persistent /data and a
read-only configuration file. No public HTTP listener is opened.
Development
uv sync --frozen
uv run ruff check .
uv run ruff format --check .
uv run pytest
uv build
Tests cover transport boundaries, malformed/stale data, temperature units, control transitions, manual changes, restart journals, and uncertain command outcomes. CI runs on Python 3.12 and 3.13. Public source contains example identifiers only; tokens and household configuration belong outside Git.
CI and release publication use the shared venus-os-ci-toolkit conventions.
Renovate uses the organization preset and central repository registry.
See release workflow for checked candidates, protected
stable promotion, and the verified SetupHelper package branch.
Repository infrastructure is owned by the isolated
terraform-github-4alvit/stacks/inverter-climate-repository Terraform stack.
Upstream references
- Home Assistant REST API
- Home Assistant climate
- Google Nest integration
- Victron D-Bus API
- Victron D-Bus paths
- Victron GX Opportunity Loads
This is an independent integration using the documented Venus D-Bus interface.
Related Projects
- inverter-control — ESS grid-zero controller; thermostat coordination remains a separate service.
- dbus-emporia-vue — optional AC-load telemetry for measured household circuits; required sources are selected explicitly in climate configuration.
- SetupHelper — Venus OS package-management helpers; use this project’s native installation guide for its lifecycle.
- venus-os-observability — optional Venus D-Bus metrics and diagnostics.
Browse the public project catalog for other Venus OS packages and companion tools. Each project documents its own installation, compatibility and release requirements.
Contributing and security
See CONTRIBUTING.md for reports, development checks and pull requests, SECURITY.md for private vulnerability reporting and deployment trust boundaries, and the OpenSSF evidence index for assessment references and remaining verification.
Release-candidate fuzzing
The real Climate parser and temperature-command validator receive synthetic thermostat observations. Accepted ranges, step sizes and commands must be finite and bounded. No thermostat, Home Assistant or D-Bus action is performed.
RC-only fuzzing policy, local reproduction and failure handling.
Metadata
Release files for inverter-climate 0.4.6
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| inverter_climate-0.4.6-py3-none-any.whl | Python 3 | none | any | Details for inverter_climate-0.4.6-py3-none-any.whl |
Release files / inverter_climate-0.4.6-py3-none-any.whl
| Download URL | inverter_climate-0.4.6-py3-none-any.whl |
|---|---|
| Size | 43.4 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
9e49b58f6cc825ccb287ca052ef605852c4f4b482d1f6c3dcc4b00614c2e69e2
|
|
BLAKE2b-256 checksum How to use checksums |
4d0b8d0b81543d0932953176f8707f3ab368fb20f452ed21084915aefd00676e
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 2, 2026.
Transparency logSecurity for inverter-climate 0.4.6
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
1 file in this release has been uploaded with provenance metadata.
Attestation for inverter_climate-0.4.6-py3-none-any.whl
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 2, 2026.