☀️ KPower Forecast 📈
Production-grade solar production and power consumption forecasting.
Built with Facebook Prophet and powered by Open-Meteo. KPower Forecast provides a high-level API for training and predicting energy metrics with physics-informed corrections.
✨ Key Features
- 🔋 Dual Mode: Specialized logic for both Solar Production and Energy Consumption.
- 🌓 Night Masking: Physics-informed clamping using solar elevation to eliminate "ghost production" at night.
- 🌡️ Weather Integration: Automatic fetching and resampling of temperature, cloud cover, and radiation.
- 🌦️ Adaptive Weather Correction: Learns location/model-specific weather bias as forecast history accumulates.
- ⚡ Optional Curtailment Limits: Clips delivered solar forecasts to inverter or export limits when configured.
- 🤖 Prophet Optimized: Pre-configured regressors for maximum accuracy.
- 💾 Smart Persistence: Automatic serialization of models to skip retraining when possible.
- ❄️ Heat Pump Mode: Optional temperature correlation for energy consumption models.
🚀 Quick Start
Installation
# Core package
pip install kpower-forecast
# With CLI support (recommended for interactive use)
pip install "kpower-forecast[cli]"
# With the local Nixtla hybrid ML forecasting backend
pip install "kpower-forecast[ml]"
# With NeuralForecast / AI forecasting support
pip install "kpower-forecast[ai]"
🖥️ CLI Usage
KPower Forecast comes with a powerful CLI for interactive forecasting and visualization.
# Forecast solar production using Home Assistant CSV export
# Supports different data categories: instant_energy, cumulative_energy, power
# Supports different units: kWh, Wh, kW, W
# Optional delivered-energy curtailment limits can be supplied in kW
kpower-forecast solar rooftop-1 46.05 14.50 -i history.csv --category power --unit W --inverter-limit 10 --export-limit 7 --horizon 7
# Forecast power consumption
kpower-forecast consumption main-meter 46.05 14.50 -i history.csv --category cumulative_energy --unit kWh --horizon 3 --heatpump
CLI Features:
- Automatic HA Parsing: Heuristic detection of
last_changedandstatecolumns. - Smart Data Normalization: Handles meter readings (cumulative), power (kW/W), and instant energy.
- Heat Pump Mode: Enable
--heatpumpto correlate consumption with outdoor temperature. - Inconsistent Intervals: Robustly handles measurements with non-uniform time gaps.
- Rich Tables: Beautiful daily summary tables in your terminal.
- Terminal Graphs: Instant visualization of forecasts and confidence intervals via
plotext.
☀️ Solar Production Forecast (API)
from kpower_forecast import KPowerForecast
from kpower_forecast.core import DataCategory, MeasurementUnit
import pandas as pd
# 1. Initialize for your location with specific data types
kp = KPowerForecast(
model_id="rooftop_solar",
latitude=46.0569,
longitude=14.5058,
forecast_type="solar",
data_category=DataCategory.POWER,
unit=MeasurementUnit.W,
inverter_ac_limit_kw=10.0,
grid_export_limit_kw=7.0,
)
# 2. Train with your history
# history_df = pd.DataFrame({'ds': [...], 'y': [...]})
# kp.train(history_df)
# 3. Predict the next 7 days
forecast = kp.predict(days=7)
print(forecast[['ds', 'yhat']].head())
🏠 Energy Consumption Forecast
kp_cons = KPowerForecast(
model_id="house_meter",
latitude=46.0569,
longitude=14.5058,
forecast_type="consumption",
heat_pump_mode=True # Accounts for heating/cooling loads
)
🧠 Optional ML Forecasting Add-on
The core KPowerForecast API remains optimized for lightweight Prophet-based
forecasting. For local classical ML workflows, install the ml extra and use
KPowerMLForecast from the optional namespace:
from kpower_forecast.ml import KPowerMLForecast, MLBackendType, MLForecastType
kp_ml = KPowerMLForecast(
model_id="house_meter_ml",
latitude=46.0569,
longitude=14.5058,
forecast_type=MLForecastType.CONSUMPTION,
backend=MLBackendType.NIXTLA_HYBRID,
)
# history_df = pd.DataFrame({'ds': [...], 'y': [...]})
# kp_ml.train(history_df, force=True)
forecast = kp_ml.predict(days=3)
print(forecast[["ds", "yhat", "yhat_lower_90", "yhat_upper_90"]].head())
The ML add-on uses Nixtla-compatible backends behind a small project-owned
backend interface. NIXTLA_HYBRID combines a statsforecast structural baseline
with an mlforecast/LightGBM residual learner and is suitable for local CPU-only
controller deployments. NEURALFORECAST is also wired as a selectable Nixtla
backend for users who install kpower-forecast[ai] and provide NeuralForecast
model objects in backend_params. Future foundation-model adapters can plug into
the same backend contract without changing the public API.
For PV forecasts, inverter_ac_limit_kw and grid_export_limit_kw cap the
predicted interval energy to account for inverter clipping and static export
curtailment. predict(dynamic_export_limits=...) also accepts a dataframe with
ds plus export_limit_kw, grid_export_limit_kw, curtailment_limit_kw, or
limit_kw for time-varying export controls.
Passive thermal response model
kpower_forecast.thermal is a separate, lightweight heating-regime API. It
identifies a stable first-order effective response from pairs of real indoor
observations at arbitrary spacing. Every pair carries coverage-gated HVAC
electric input; by default a transition needs an hvac_coverage_ratio of at least 0.90
(the EMS adapter reports its least-covered five-minute bucket). train_with_weather obtains historical outdoor temperature
from this package's weather client and integrates it across each actual
observation interval; indoor targets are never interpolated onto a regular
grid. The effective gain is a building response coefficient, not COP.
Training weather combines archive dates with the forecast endpoint's recent
past_days window (one day by default, plus today). Future date padding never
reaches the archive endpoint. Strict thermal callers preserve missing weather
and reject uncovered observation intervals. Recent weather uses the forecast
cache expiry rather than the long-lived archive cache; relative forecast
requests also refresh at UTC midnight.
from kpower_forecast.thermal import KPowerThermalForecast, ThermalObservedTransition
model = KPowerThermalForecast(
model_id="thermal_aggregate",
authority_fingerprint="site-and-zone-configuration-epoch",
storage_path="./data",
latitude=46.0569,
longitude=14.5058,
)
# observations: list[ThermalObservedTransition] from genuine indoor endpoints
# diagnostics = model.train_with_weather(observations)
# model.save() # only when fitted; load() checks lineage and contract
# forecast = model.predict_with_weather(
# origin=aligned_utc_origin,
# initial_temperature_c=fresh_real_indoor_c,
# hvac_electric_power_w=existing_heating_forecast_w,
# hvac_drive_source="legacy_heating_forecast",
# )
Fit. Transitions are linked into chains; a gap of up to 30 minutes
between two covered transitions (typically one rejected for HVAC coverage) is
bridged by filling its inputs from the neighbouring intervals, while the
reading that resumes the chain stays the real target. Overlapping 6-24 hour
windows starting at real readings are simulated with the RC model, and the
loss covers every real reading in each window (output error). The time constant
is a grid search with a weak log-normal prior (median 60 h); gain and offset
are bounded least squares on the simulated response. The one-step transition
fit is also computed (transition_fit). When it is within the hard limits and
replays the holdout better at the skill horizons, it is published instead and
fit_method reads transition; on the reference site this was the case for one
closed-loop TRV zone.
Quality. Acceptance needs the accepted-history gates (72 h, 40
transitions, excitation) and a holdout MAE at +3/+6/+12 h at least 5 % below
persistence on two horizons. Sensors quantised to 0.1-0.2 °C make one-step
error indistinguishable from persistence, so one-step metrics are reported but
do not decide. A fit with a constrained coefficient, a boundary or flat time
constant, or less history (at least 24 h) is published as
quality="low_identifiability" with 1.5x wider bands, unless it is worse than
persistence on the holdout, in which case it is not fitted. Hard limits
(2-240 h, gain at most 20 °C/kW, |offset| at most 12 °C) still apply.
Artifacts. load() restores an artifact of the same model ID, lineage
fingerprint, contract and config. One written by another package version or
weather configuration loads with needs_retrain=True; callers should retrain
on the same history rather than discard the fit.
Derived and naive forecasts. predict(..., equilibrium_shift_c=...) and
evaluate_with_weather(..., equilibrium_shift_c=...) let a caller derive a
zone from the aggregate fit and score that against the zone's own fit.
predict_naive holds the current reading while fading a damped recent trend
(recent_trend_c_per_hour); it is the model-free last fallback.
Training diagnostics include rejected durations/coverage, excitation, fitted time constant and gain, chronological holdout replay at 1/3/6/12 hours, persistence comparison, and empirical temperature error bands. EMS must additionally validate real future origins before granting any electrical forecast authority. The API never chooses HVAC modes or an HVAC electrical schedule.
Offline identification matrix (calibration only)
With the cli extra installed, run:
python -m kpower_forecast.thermal.identification private-bundle.json private-report.json
MatrixBundle is a strict Pydantic boundary. Its frozen manifest declares the
model/source authority epoch, export start, fit cutoff, evaluation start (at least
six hours after fitting), final export cutoff, input provenance, target tolerance
and documented source confidence. Aware input timestamps normalize to UTC before
window arithmetic and serialization. series contains all keys 5, 10, 15, 30,
60, even if empty. Each series is an independently admitted minimum-separation
selection of genuine endpoints, with exact elapsed time, covered HP electrical
exposure and pre-exported outdoor means. source_authority_id must describe the
same selected authority at both endpoints. Data adapters own intermediate source,
receipt, quality and exposure checks; this tool cannot reconstruct them from rows.
Never rename five-minute rows to manufacture a longer-resolution experiment.
The report includes all 7/14/21-day configurations and an unweighted/runtime
baseline versus diagnostic confidence/elapsed weighting. Unknown sensor accuracy
uses a named manifest assumption (default 0.1 C standard deviation); documented
quantization contributes resolution_c**2/12. The conservative two-endpoint
variance bound does not assume independent endpoint errors. Confidence ratios
are capped before elapsed-duration weighting. Precision does not establish accuracy.
The solver and physical acceptance limits are shared with the existing RC model. Rejected boundary/sign optima remain visible as diagnostics; tau remains bounded at 240 h. Neighbor comparisons expose coefficient changes and sign agreement, including rejected fits. Complete requested history must be available within the authority/export boundary; short datasets are explicitly unavailable.
All physically accepted candidates replay the same chronological real calibration targets at 30 min, 1 h, 2 h and 4 h, using observed input exposure and a persistence baseline. A source/gap/value discontinuity breaks replay; no indoor interpolation is allowed. Unmatched targets stay unmatched. These are observed-drive response checks, not operational unseen-origin forecast evidence. Internal blocked holdout status is reported separately; it cannot establish empirical reliability.
This first slice excludes calibrated excitation/cycle scoring, disturbance classification, cycle-balanced weighting, final holdout selection and live-manager integration. It never saves an operational model, requests weather, modifies a controller or grants control/electrical authority. Keep private bundles/reports outside Git. Identical CLI reruns are harmless; different existing outputs are refused. Reports are completed and flushed in a private temporary sibling, then atomically published without replacing an existing final report.
Time and history contract
Forecast timestamps and the ds grid remain UTC. ML calendar and holiday features are derived
temporarily in the configured IANA timezone. Artifact contract version 3 records that timezone and
history policy version 2, so incompatible artifacts are retrained before prediction.
Callers can enable preserve_gaps. Power samples are then converted independently using the fixed
interval duration, cumulative energy is differenced only across adjacent valid samples, and missing
target intervals remain missing through normalization and feature construction.
Prediction weather for an elapsed prefix combines archive and recent-forecast weather. Only the seam between the two sources, at most one hour (the hourly archive ends at 23:00 while the recent forecast starts at 00:00), is interpolated in time; any other missing weather slot still fails grid alignment.
Telemetry with intermittent dropouts can set max_bridged_gap_intervals (default 0, off;
requires preserve_gaps=True, power or instant-energy input and a non-solar target). Interior
missing runs up to that many intervals are bridged linearly after normalization so a single dropped
row no longer splits the latest structural segment. Longer, leading and trailing gaps stay missing.
Bridged rows are excluded from weather-bias fitting and conformal calibration, the persisted
baseline history keeps the original gaps, and the manifest records the limit and bridged row count.
Holdout candidate selection
Consumption and HVAC targets can set candidate_selection=True (default off; not for solar).
Training then scores three candidates on the calibration holdout, each forecasting it from the
same origin with the same historical weather, and serves the one with the lowest RMSE:
kpower_ml: the configured ML backend (ties keep it);degree_hour_regression: ridge regression with per-local-hour intercepts,max(0, regression_base_temperature_c − T_out)(default 16 °C) andregression_extra_features(default shortwave radiation);local_slot_weekday_class_median: the leakage-safe slot/weekday median.
RMSE, not MAE, decides because MAE rewards an always-off forecast of an on/off load. Prediction
intervals are calibrated on the winner's holdout residuals. With fewer than
min_selection_holdout_rows measured holdout rows (default 96) the ML model is kept and
selection_reason is holdout_too_short. selected_candidate, candidate_metrics and the
regression coefficients are persisted in the manifest. An artifact trained with different
selection settings (candidate_selection, regression_base_temperature_c,
regression_extra_features) is retrained.
🛠️ Advanced Configuration
| Parameter | Type | Default | Description |
|---|---|---|---|
model_id |
str |
required | Unique ID for model persistence |
latitude |
float |
required | Location Latitude |
longitude |
float |
required | Location Longitude |
interval_minutes |
`int" | 15 |
Data resolution (15 or 60) |
storage_path |
str |
"./data" |
Directory for saved models |
heat_pump_mode |
bool |
False |
Enable temperature regressor for consumption |
adaptive_weather_correction |
bool |
True |
Learn weather correction from archived forecasts, with historical weather fallback |
inverter_ac_limit_kw |
float | None |
None |
Optional inverter AC output limit in kW |
grid_export_limit_kw |
float | None |
None |
Optional grid export limit in kW |
Adaptive weather correction is conservative on new sites. Initial training works without historical forecast snapshots by falling back to archive weather, then improves as generated forecasts are archived and later matched with actual production.
🔢 Versioning
This project follows a custom Date-Based Versioning scheme:
YYYY.MM.Patch (e.g., 2026.2.1)
- YYYY: Year of release.
- MM: Month of release (no leading zero, 1-12).
- Patch: Incremental counter for releases within the same month.
Enforcement
- CI Validation: Every Pull Request is checked against
scripts/validate_version.pyto ensure adherence. - Consistency: Both
pyproject.tomlandsrc/kpower_forecast/__init__.pymust match exactly.
🧪 Development & Testing
We use uv for lightning-fast dependency management.
# Clone and setup
git clone https://github.com/akorenc/kpower-forecast
cd kpower-forecast
uv sync --all-extras
# Run tests
uv run pytest
# Linting
uv run ruff check .
📄 License
Distributed under the GNU Affero General Public License v3.0. See LICENSE for more information.
Made with ❤️ for a greener future.
Metadata
Release files for kpower-forecast 2026.10.4
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | |
|---|---|---|---|
| kpower_forecast-2026.10.4.tar.gz | 273.5 kB | Details |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Reset |
|---|---|---|---|---|
| kpower_forecast-2026.10.4-py3-none-any.whl | Python 3 | none | any | Details |
Total release size: 383.4 kB
Release files / kpower_forecast-2026.10.4.tar.gz
| Download URL | kpower_forecast-2026.10.4.tar.gz |
|---|---|
| Size | 273.5 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
6613cc58730550bd57489e1993a9b0c1cecbdfa72e1b5ac320befce6da5c241b
|
|
BLAKE2b-256 checksum How to use checksums |
de024bfb03d0514e4451111e0e7383c9204e557fa0f874340601494ad50d9024
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
uv/0.12.22 {"installer":{"name":"uv","version":"0.12.22","subcommand":["publish"]},"python":null,"implementation":{"name":null,"version":null},"distro":{"name":"Ubuntu","version":"24.04","id":"noble","libc":null},"system":{"name":null,"release":null},"cpu":null,"openssl_version":null,"setuptools_version":null,"rustc_version":null,"ci":true}
|
Release files / kpower_forecast-2026.10.4-py3-none-any.whl
| Download URL | kpower_forecast-2026.10.4-py3-none-any.whl |
|---|---|
| Size | 109.9 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
c7457db2ec5e37c10373149862e9a753eaf1e1a158d80be845ff3b9b483bc799
|
|
BLAKE2b-256 checksum How to use checksums |
5e74cb909252496dc1f85c8fee805b6caee9f63b7a5714373d4c1db68012d4cd
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
uv/0.12.22 {"installer":{"name":"uv","version":"0.12.22","subcommand":["publish"]},"python":null,"implementation":{"name":null,"version":null},"distro":{"name":"Ubuntu","version":"24.04","id":"noble","libc":null},"system":{"name":null,"release":null},"cpu":null,"openssl_version":null,"setuptools_version":null,"rustc_version":null,"ci":true}
|