Bench DC Power Supply — MCP Server

Let an AI agent set voltages and current limits, switch outputs on and off, watch constant-voltage / constant-current behaviour and configure over-voltage / over-current protection on programmable DC bench power supplies from Rigol, Siglent and Aim-TTi, using each vendor's documented remote command set. The dialect is detected from *IDN?.

Package labmcp-bench-psu
Instruments Rigol DP832/DP832A, DP831, DP822, DP821, DP811, DP813, DP711, DP712, DP932A/U/E; Siglent SPD3303X/X-E, SPD1168X, SPD1305X; Aim-TTi CPX400D/DP, MX100T/TP, MX180T/TP, QL355/QL564 (P, T/TP), PL-P (PL068/155/303/601, PL303QMD/QMT)
Interfaces USB (USB-TMC via VISA, or virtual COM on Aim-TTi), LAN (VISA/VXI-11 or raw socket), RS-232, GPIB via VISA
Protocol SCPI (Rigol DP800 Programming Guide, DP700, DP900; Siglent SPD3303X Quick Start, SPD1000X User Manual) and Aim-TTi remote commands (CPX400D/DP manual, MX100T/TP manual, manuals index)
Status 🧪 simulated: tested against wire-level simulators of each dialect driving a resistive load, not yet verified on hardware. Report a hardware test

Keysight / Agilent and Rohde & Schwarz supplies are intentionally not covered: both vendors publish official MCP servers. Use the Keysight MCP Server for Instrument Control or the MCP server included in Rohde & Schwarz RsInstrument. This server refuses to connect to them.

Try it without hardware

uvx labmcp-bench-psu --simulate --check                                        # Rigol DP832
uvx labmcp-bench-psu --simulate --option dialect=siglent --check               # Siglent SPD3303X
uvx labmcp-bench-psu --simulate --option dialect=tti --option sim_model=MX100TP --check

The simulated outputs drive resistive loads (CH1 10 Ω, CH2 100 Ω, CH3 open), so you can watch the CV → CC crossover and trip OVP/OCP.

Connect your instrument

  1. Instrument setup: enable the interface you use (Rigol: Utility → I/O Config; Siglent: System → Interface; Aim-TTi: LAN works out of the box, USB appears as a virtual COM port). Note the IP address or VISA resource string.
  2. Find the address: uvx labmcp ports (serial) or python -m pyvisa info / your VISA vendor's tool (USB/LAN).
  3. Test the connection:
    uvx labmcp-bench-psu --address "USB0::0x1AB1::0x0E11::DP8C123456789::INSTR" --check   # Rigol over USB-TMC
    uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --check                 # any LXI/VXI-11 supply
    uvx labmcp-bench-psu --address tcp://192.168.1.51:5025 --check                       # Siglent raw socket
    uvx labmcp-bench-psu --address tcp://192.168.1.52:9221 --check                       # Aim-TTi raw socket
    uvx labmcp-bench-psu --address /dev/ttyACM0 --check                                  # Aim-TTi USB virtual COM
    uvx labmcp-bench-psu --address "serial://COM3?write_termination=CRLF" --check        # Rigol DP800 RS-232
    
    USB-TMC and VXI-11 addresses use PyVISA (installed with this package; add ?backend=@ivi to use NI-VISA / Keysight IO Libraries instead of pyvisa-py).

Add to your MCP client

Claude Code

claude mcp add psu -- uvx labmcp-bench-psu --address "TCPIP0::192.168.1.50::INSTR" --limit max_voltage_v=12 --limit max_current_a=1

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "psu": {
      "command": "uvx",
      "args": ["labmcp-bench-psu", "--address", "TCPIP0::192.168.1.50::INSTR",
               "--limit", "max_voltage_v=12", "--limit", "max_current_a=1"]
    }
  }
}

Add --read-only to allow monitoring only: setpoint changes and output_on are hidden, while output_off and all_outputs_off stay available. For other clients, generate the snippet with uvx labmcp config bench-psu --address TCPIP0::192.168.1.50::INSTR --client vscode.

Tools

Tool Kind Description
all_outputs_off 🛑 safety Switch every output OFF (emergency stop for the whole supply). Each channel is switched individually and read back where the instrument supports it.
clear_protection_trip 🎛 control Clear an OVP/OCP trip after fixing its cause. The output stays OFF; use output_on to re-energise. On Aim-TTi supplies this clears trips on all outputs.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_errors 👁 read Read (and clear) the instrument's error queue / error registers. Empty list = no errors.
get_outputs 👁 read Report each channel: voltage and current-limit setpoints, measured voltage/current/power, output on/off, CV/CC mode, and OVP/OCP levels and trip state where the model supports them.
output_off 🛑 safety Switch a channel's output OFF. Safe to call at any time.
output_on ⚠️ hazard Switch a channel's output ON, energising the connected load at the present setpoints. The setpoints are read back first and the output is refused if they exceed the safety limits (e.g. after someone changed them on the front panel).
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_current_limit 🎛 control Set a channel's current limit (the constant-current setpoint). Refused above max_current_a (checked even with the output off) or above the channel's range.
set_protection 🎛 control Set over-voltage (OVP) and/or over-current (OCP) protection for a channel. When exceeded, the supply switches the output off. Rigol: levels + on/off; Aim-TTi CPX/QL/PL-P: levels (always armed), MX: levels + on/off; Siglent SPD1000X: levels only; SPD3303X: not available.
set_voltage 🎛 control Set a channel's voltage setpoint. Refused above max_voltage_v (checked even with the output off) or above the channel's range. If the output is on, the load sees the new voltage at once.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

Limit Default Meaning
max_voltage_v 30 V Largest voltage setpoint (magnitude) on any channel. Checked when setting the voltage, even with the output off, and again before output_on
max_current_a 3 A Largest current-limit setpoint on any channel, checked the same way

Override at launch, e.g. --limit max_voltage_v=12 --limit max_current_a=0.5. Setpoints are also checked against each model's settable range. output_on reads the setpoints back from the instrument first, so a value changed on the front panel cannot slip past the limits.

Example prompts

  • "Show me all channels of the power supply: setpoints, measured current and whether they're in CV or CC."
  • "Set CH1 to 12 V with a 200 mA current limit, set OVP at 13 V, then turn it on and tell me how much current the LED array draws."
  • "Ramp CH2 from 0 to 5 V in 0.5 V steps, reading the current at each step, and plot the I-V curve of the load."
  • "The heater is drawing more than expected: turn every output off now."
  • "Channel 1 tripped. What happened, and is it safe to clear the trip?"

Notes

  • Dialect detection: *IDN? manufacturer "RIGOL" → Rigol, "Siglent" → Siglent, "THURLBY THANDAR"/"TTi"/"Aim" → Aim-TTi. Force one with --option dialect=rigol|siglent|tti for rebadged units. Models not in the built-in table are treated as --option channels=N channels with no model maxima (the safety limits still apply).
  • Rigol: setpoints via :SOUR<n>:VOLT/CURR, readback via :APPL? CHn and :MEAS:ALL? CHn, mode via :OUTP:MODE? CHn (CV/CC/UR), OVP/OCP via :OUTP:OVP|OCP[:STAT|:VAL|:QUES?]. Trips are cleared with :OUTP:OVP|OCP:CLEAR, which only clears the flag. [:SOUR]:VOLT:PROT:CLE is never sent because the programming guide says it also turns the output on. DP831 CH3 is a negative output: give negative voltages (not yet verified on hardware). Over RS-232 the DP800 needs CR LF line endings (?write_termination=CRLF).
  • Siglent: SPD3303X/X-E have no programmable OVP/OCP and report output state and CV/CC only through the SYST:STAT? status word (CH1/CH2). CH3 is fixed (2.5/3.3/5 V by front-panel switch) and can only be switched on/off; its state is not readable. SPD1000X has OVP/OCP levels only (always armed, trip state not readable). The error reply format (0 No Error) is not SCPI-standard, so settings are verified by reading them back. The server pauses 0.1 s after each command to Siglent supplies (--option write_delay_s= to change); Siglent's own examples wait between commands, but the required delay is not documented.
  • Aim-TTi: there is no live CV/CC query, so mode is inferred from readback vs setpoints (mode_source: "inferred"). Trip flags come from the LSR<n>? limit event register, which latches events and is cleared by reading it. CPX/QL/PL-P protection is always armed (levels only); MX models can also switch OVP/OCP on/off. TRIPRST clears trips on all outputs (not documented for MX100T/TP). Original QL P/T models have no output-state query, so their output_on is reported as unknown. OPALL 0 is sent first in all_outputs_off, then every output individually.
  • Tracking / series / parallel modes, timers, sequences, remote sense and saved set-ups are not exposed. Put the supply in independent mode before handing it to an agent.
  • GW Instek GPP and B&K Precision 9130/9140 supplies are not supported yet: too many reply formats are undocumented in their manuals to implement them safely.

Hardware verification

Model Firmware Interface Verified by Date
none yet: be the first

Release files for labmcp-bench-psu 0.1.2

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-bench-psu 0.1.2
File Size Uploaded
labmcp_bench_psu-0.1.2.tar.gz 25.2 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-bench-psu 0.1.2
File Interpreter ABI Platform
labmcp_bench_psu-0.1.2-py3-none-any.whl Python 3 none any Details

Total release size: 49.3 kB

Release files / labmcp_bench_psu-0.1.2.tar.gz

Download URL labmcp_bench_psu-0.1.2.tar.gz
Size 25.2 kB
Tags Source
SHA-256 checksum
How to use checksums
1fcf6a2666441f648a4b61ab08faae9963b73676d5eb814e0fb89c19f4e02600
BLAKE2b-256 checksum
How to use checksums
0ba241c718d72a6bc4bd92dd258a25a338503b9b82fc169a59cc67f724a2ef17
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_bench_psu-0.1.2-py3-none-any.whl

Download URL labmcp_bench_psu-0.1.2-py3-none-any.whl
Size 24.2 kB
Tags Python 3
SHA-256 checksum
How to use checksums
361ebe6d47733e6340ce21b618e5ff29efdd96a53c233f1fa6f5fd53c38c156a
BLAKE2b-256 checksum
How to use checksums
9963b61e5428cf4a6f100629251aad22d5947b31a7d245124eef933a753e23dc
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

0.1.3

2 release files

This release

0.1.2 This release

2 release files

0.1.1

2 release files

0.1.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page