Keithley SourceMeter SMU — MCP Server

Let an AI agent source voltage or current with a compliance limit, measure V and I, and run bounded IV sweeps (linear, log, dual) on Keithley (Tektronix) SourceMeter SMUs. Every sweep ends with the output switched off, even when something goes wrong. The server speaks all three Keithley remote dialects: 2400-series SCPI, 2450-family SCPI, and 2600B TSP.

Package labmcp-keithley-smu
Instruments 2400, 2400-LV, 2401, 2410, 2420, 2425, 2430 (DC mode), 2440 · 2450, 2460, 2461, 2470 (SCPI command set) · 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, 2636B
Interfaces GPIB, USB (USBTMC), Ethernet (VXI-11 / raw socket 5025), RS-232 (2400 series), via VISA or tcp://
Protocol SCPI: 2400 Series User's Manual 2400S-900-01 Rev. K §18, 2450 Reference Manual 2450-901-01 Rev. D §6. TSP: 2600B Reference Manual 2600BS-901-01 Rev. F §9
Status 🧪 simulated: tested against wire-level simulators of all three dialects, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-keithley-smu --simulate --check                                   # 2450 + 1 kΩ resistor
uvx labmcp-keithley-smu --simulate --option dialect=2600 --option sim_dut=diode --check
uvx labmcp-keithley-smu --simulate --option dialect=2400 --option sim_resistance_ohm=47 --check

The simulated DUT is a resistor (1 kΩ by default) or a 1N4148-like diode (Shockley equation, I_s = 2.52 nA, n = 1.752, R_s = 0.568 Ω). Compliance clamping behaves as on a real SMU.

Connect your SMU

  1. Instrument side.
    • 2400 series: GPIB (default address 24) or RS-232. For RS-232 set MENU > COMMUNICATION > RS-232: 9600 baud, 8 data bits, no parity, TERMINATOR LF, no flow control.
    • 2450 / 2460 / 2461 / 2470: use the SCPI command set (MENU > System > Settings > Command Set > SCPI, then reboot). If the instrument is in TSP mode the server stops with instructions. In SCPI2400 emulation mode it is driven with the 2400 dialect. Above ±21 V the 2450 needs its safety interlock closed.
    • 2600B: works as shipped (TSP). Leave localnode.prompts disabled (the default); prompts would be mixed into replies.
  2. Find the address: uvx labmcp ports (or python -m pyvisa info). GPIB and USBTMC need a VISA library with GPIB support. NI-VISA works everywhere; pyvisa-py covers USBTMC/LAN (and GPIB with gpib-ctypes/linux-gpib).
  3. Test the connection:
    uvx labmcp-keithley-smu --address GPIB0::24::INSTR --check
    uvx labmcp-keithley-smu --address USB0::0x05E6::0x2450::04096331::INSTR --check
    uvx labmcp-keithley-smu --address tcp://192.168.1.50:5025 --check             # 2450 / 2600B LAN
    uvx labmcp-keithley-smu --address TCPIP0::192.168.1.51::inst0::INSTR --option channel=b --check   # 2602B, SMU B
    
    The dialect is detected from *IDN? (and *LANG? on the 2450 family). Force it with --option dialect=2400|2450|2600.

Add to your MCP client

Claude Code

claude mcp add smu -- uvx labmcp-keithley-smu --address GPIB0::24::INSTR --limit max_voltage_v=5 --limit max_current_a=0.02

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "smu": {
      "command": "uvx",
      "args": ["labmcp-keithley-smu", "--address", "USB0::0x05E6::0x2450::04096331::INSTR",
               "--limit", "max_voltage_v=5", "--limit", "max_current_a=0.02"]
    }
  }
}

Add --read-only to allow status and measurements but block configuration, output-on and sweeps (output_off stays available). For other clients, generate the snippet with uvx labmcp config keithley-smu --address <resource> --client vscode (also cursor, codex, claude-code).

Tools

Tool Kind Description
configure_source 🎛 control Set up the source (function, level, compliance, range, measurement speed) while the output is OFF. Measures V and I with auto-ranging. Refused if the output is on; turn it off first or use set_source_level. Limits are checked before anything is sent.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info 👁 read Identify the SMU: manufacturer, model, serial, firmware, command dialect (2400 / 2450 / 2600), channel (2600B) and the model's maximum source voltage and current.
get_status 👁 read Report whether the output is on, the source function (voltage/current), programmed level, compliance limit, whether the source is in compliance, terminals and 2/4-wire sense.
measure 👁 read Take one source-measure reading (voltage, current, V/I, power, compliance flag) of the energised DUT. Does not change any setting; refused if the output is off.
output_off 🛑 safety Switch the SMU output OFF immediately (and abort any IV sweep in progress). Always available, including in read-only mode.
output_on ⚠️ hazard Switch the SMU output ON: the configured voltage or current is applied to the DUT. The programmed level and compliance are read back from the instrument and checked against the safety limits first. Confirm with the user that the DUT is connected and safe to energise.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
run_iv_sweep ⚠️ hazard Run a stepped IV sweep: configure the source, switch the output ON, step through the levels measuring V and I at each, then ALWAYS switch the output OFF (also on errors or when output_off is called). Returns the curve (downsampled), compliance flags, a linear fit and optional full CSV (a new file; an existing file is never overwritten). The output must be off beforehand. Limits are checked first.
set_4wire 🎛 control Select 4-wire (remote sense, Kelvin) or 2-wire measurement. 4-wire removes lead resistance for low-resistance DUTs but needs the SENSE leads connected. Refused while the output is on.
set_source_level ⚠️ hazard Change the level of the configured source. If the output is ON the new voltage/current is applied to the DUT immediately. The level and the present compliance are checked against the safety limits first.

get_connection_info, get_command_log and reconnect are built into every LabMCP server.

Safety limits

Limit Default Meaning
max_voltage_v 20 V Largest |voltage| an agent may source, or allow as voltage compliance
max_current_a 0.1 A Largest |current| an agent may source, or allow as current compliance
max_power_w 2 W Largest worst-case power |source level × compliance|
max_sweep_points 501 Most points in one IV sweep (the return leg of a dual sweep counts)
max_sweep_duration_s 600 s Longest estimated sweep duration (points × (delay + 2·NPLC/50 s + 20 ms))

The limits are checked before anything is sent: by configure_source and set_source_level, by run_iv_sweep (on the largest |start|, |stop|), and by output_on, which reads the programmed level and compliance back from the instrument. A level set on the front panel is therefore caught too. Requests beyond the model's own maximum (e.g. 40 V on a 2602B) are also refused. Override at launch: --limit max_voltage_v=60 --limit max_power_w=10. Tighten the defaults for fragile DUTs.

Example prompts

  • "Measure the IV curve of this LED from 0 to 3 V in 61 steps with a 20 mA compliance, then tell me the turn-on voltage at 1 mA."
  • "Source 1 mA through the sample in 4-wire mode and give me its resistance; then turn the output off."
  • "Run a dual sweep from −1 V to +1 V on the memristor with 1 mA compliance and 0.1 s per point, and save it to ~/data/memristor_run3.csv."
  • "Do a log current sweep from 1 nA to 10 mA on the photodiode with a 2 V limit and fit the ideality factor."
  • "What is the SMU doing right now? If the output is on, turn it off."

Notes

  • Simple, verifiable commands. Sweeps are stepped loops: set the level, wait delay_s, take one reading, check compliance. Built-in instrument sweeps and trigger models are not used, so every point shows up in get_command_log. The output is switched off in a try/finally at the end of every sweep. Calling output_off while a sweep runs (even while it is still configuring) sets an abort flag and switches the output off at once; the sweep then stops without switching the output on again and reports aborted: true.

  • Sweep duration. Besides max_sweep_duration_s, one sweep can take at most 1740 s (the tool's 30-minute timeout minus a margin): longer estimates are refused, and a sweep that runs slower than estimated stops early with the output off and returns the points measured so far (stop_reason says why).

  • save_path must end in .csv and must not exist yet (an existing file is never overwritten); missing folders are created. It is checked before the output is switched on.

  • Overflow readings (the SMU's +9.9E37 marker) are returned as null in the sweep curve, counted in overflow_points and left out of the statistics and the fit; measure reports them as an error.

  • What is measured.

    • 2400: concurrent V and I (:SENS:FUNC:CONC ON, :SENS:FUNC "VOLT","CURR"), read with :READ? (:FORM:ELEM VOLT,CURR,STAT). Compliance comes from status-word bit 3.
    • 2450: the measure function is the non-sourced quantity, source readback is on, and :READ? "defbuffer1",SOUR,READ returns both. Compliance comes from :SOUR:VOLT:ILIM:TRIP? / :SOUR:CURR:VLIM:TRIP?.
    • 2600B: print(smuX.measure.iv()) and print(smuX.source.compliance).

    In compliance, the reported V and I are the measured values, not the programmed level.

  • The 2400's :MEAS? turns the output on by itself (manual p. 18-72), so it is never used. measure refuses to run when the output is off.

  • Reconfiguration happens with the output off. configure_source and set_4wire refuse while the output is on. Use set_source_level (a hazard tool) to change a running source.

  • Output-off state (normal / zero / high-Z / guard) is left as configured on the instrument. With the default normal state, a current source turned off becomes a 0 V source. For batteries, charged capacitors or solar cells, select high-impedance first (2450 manual p. 6-40).

  • The 2460/2461/2470 maxima are not built in (their manuals weren't reviewed). The safety limits still apply, and the instrument rejects anything beyond its range. The 2430 pulse mode and the 2600B's limitp power compliance are not used.

  • Timing: NPLC sets the integration time (1 PLC = 16.7 ms at 60 Hz, 20 ms at 50 Hz). Source auto-delay stays at the instrument default (on), and delay_s adds settling time per point.

  • Simulator error replies follow the manuals' error lists (+802 "Not permitted with OUTPUT off", -222, -113; 2600B 1101 "Parameter too big", -285/-286). The exact message wording on real firmware may differ.

Hardware verification

Model Firmware Interface Verified by Date
none yet: be the first

Release files for labmcp-keithley-smu 0.1.2

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-keithley-smu 0.1.2
File Size Uploaded
labmcp_keithley_smu-0.1.2.tar.gz 29.1 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-keithley-smu 0.1.2
File Interpreter ABI Platform
labmcp_keithley_smu-0.1.2-py3-none-any.whl Python 3 none any Details

Total release size: 55.8 kB

Release files / labmcp_keithley_smu-0.1.2.tar.gz

Download URL labmcp_keithley_smu-0.1.2.tar.gz
Size 29.1 kB
Tags Source
SHA-256 checksum
How to use checksums
049ef67402cf4b849d8fcf4898c32d9a9840af78217c6a337b16b2e65a7d973f
BLAKE2b-256 checksum
How to use checksums
dc7e3c560ab632fd35e9359bf3d063fd24aabc87481d5fc2347442a6f44f6038
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_keithley_smu-0.1.2-py3-none-any.whl

Download URL labmcp_keithley_smu-0.1.2-py3-none-any.whl
Size 26.7 kB
Tags Python 3
SHA-256 checksum
How to use checksums
4c3528fd3cd9908c83466bc2db564ad143ff11bd108b2694b79a0bf82bf9e0f9
BLAKE2b-256 checksum
How to use checksums
445deba7f414f929e717453b4cf470e6eb4a3afe018a1b233f07f56cd79edc6b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

This release

0.1.2 This release

2 release files

0.1.1

2 release files

0.1.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page