Micro-Manager Microscope — MCP Server

Let an AI agent snap images, acquire z-stacks and time-lapses, move the stage and focus within limits you set, switch channels and objectives, set exposure, operate shutters and run autofocus on any microscope controlled by Micro-Manager, through its open device layer (MMCore) and pymmcore-plus.

Package labmcp-micro-manager
Instruments Any hardware with a Micro-Manager device adapter (hundreds of cameras, XY/Z stages, microscope stands, filter wheels, shutters and light sources from Hamamatsu, Photometrics, Andor, PCO, Basler, ASI, Prior, Ludl, Märzhäuser, Nikon, Zeiss, Olympus/Evident, Leica, Lumencor, CoolLED and others), described by a Micro-Manager .cfg hardware configuration
Interfaces Whatever the device adapters use: USB, serial, Camera Link / CoaXPress / GigE frame grabbers
Protocol Micro-Manager MMCore API via pymmcore-plus CMMCorePlus (MMCore API reference, pymmcore-plus API, configuration guide)
Status 🧪 simulated: tested against a simulated microscope and against pymmcore-plus' real core with Python test devices, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-micro-manager --simulate --check

The simulator is a widefield fluorescence microscope with a 512 x 512, 12-bit camera, an XY stage, a focus drive, a shutter, a DAPI / FITC / TRITC / Brightfield filter wheel, a 10x / 20x / 40x turret and a hardware autofocus, looking at a field of cell nuclei. Its images defocus with Z, scale with exposure, bleach with light dose, saturate at 4095 and carry shot and read noise, so focusing, exposure and bleaching behave like on a real microscope.

Connect your microscope

  1. Hardware configuration: create and test a .cfg file with Micro-Manager's Hardware Configuration Wizard (in the Micro-Manager app), including config groups for channels (usually Channel) and objectives (Objective) and a pixel-size calibration. Close the Micro-Manager app afterwards: a device can only be opened by one program.
  2. Device adapters: pymmcore-plus needs Micro-Manager's device adapter libraries in a version that matches its pymmcore build. Either download them with pymmcore-plus' own installer:
    uvx --from labmcp-micro-manager mmcore install     # into pymmcore-plus' data folder
    uvx --from labmcp-micro-manager mmcore list        # show what was found
    
    or point to an existing Micro-Manager installation with --option mm_path=/path/to/Micro-Manager (it must be a build whose device interface matches pymmcore; mmcore info shows the version). Vendor camera SDKs and drivers must be installed separately, as for Micro-Manager itself.
  3. Test the connection:
    uvx labmcp-micro-manager --address ~/scopes/Ti2_Prime95B.cfg --check
    uvx labmcp-micro-manager --address MMConfig_demo.cfg --check      # Micro-Manager demo devices
    
    --check loads the configuration and prints the camera, stages and other device roles.

Add to your MCP client

Claude Code

claude mcp add microscope -- uvx labmcp-micro-manager --address /path/to/MyScope.cfg --option z_min_um=0 --option z_max_um=4500

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "microscope": {
      "command": "uvx",
      "args": ["labmcp-micro-manager", "--address", "/path/to/MyScope.cfg",
               "--option", "z_min_um=0", "--option", "z_max_um=4500",
               "--option", "data_dir=/data/microscope"]
    }
  }
}

Add --read-only to let the agent read positions and settings without imaging or moving anything (stop_stage and close_shutter stay available). For other clients, generate the snippet with uvx labmcp config micro-manager --address /path/to/MyScope.cfg --client vscode (also cursor, codex, claude-code).

Tools

Tool Kind Description
acquire_time_lapse ⚠️ hazard Acquire a time-lapse at the current position: images every interval_s (optionally several channels per timepoint), saves a multi-page TIFF and reports per-frame statistics and the intensity change (bleaching). Bounded by max_frames and max_acquisition_duration_s; stop_stage aborts it.
acquire_z_stack ⚠️ hazard Acquire a z-stack around the current focus: moves Z through the slices (optionally imaging several channels at each), saves a multi-page TIFF, reports per-slice statistics and the sharpest slice, and returns Z to where it started. Every slice must stay within max_z_step_um of the start and the Z soft limits.
autofocus ⚠️ hazard Run the configured autofocus device (e.g. a hardware focus lock) once; it moves the focus drive. If the result is outside the Z step or soft limits, the focus is moved back and an error is raised.
close_shutter 🛑 safety Close the shutter (stop illuminating the sample) and abort any running acquisition.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_exposure 👁 read Return the camera exposure time in milliseconds.
get_position 👁 read Read the XY stage and focus (Z) positions in micrometres, and which way increasing Z moves the objective.
get_system_info 👁 read Describe the microscope: loaded devices (camera, stages, shutters, filter wheels...), which device has which role, camera size/bit depth/exposure, pixel size, config groups with their presets, the current position, and the soft limits. Call this first.
list_config_groups 👁 read List Micro-Manager config groups (e.g. Channel, Objective) with their presets and the preset currently active.
move_stage_xy ⚠️ hazard Move the XY stage. Moves longer than max_xy_step_um or outside the XY soft limits are refused before anything moves. Make sure the objective and condenser clear the sample holder.
move_z ⚠️ hazard Move the focus drive (Z). Moving the objective toward the sample can crash it into the slide: moves larger than max_z_step_um or outside the Z soft limits are refused before anything moves.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_config 🎛 control Apply a config-group preset (e.g. switch the channel: filter cube, light source, emission filter). Objective/turret groups are refused here: use set_objective.
set_exposure 🎛 control Set the camera exposure time (ms). Longer exposures give brighter images but more photobleaching. Returns the exposure the camera accepted.
set_objective ⚠️ hazard Switch the objective (rotates the nosepiece/turret). A longer or immersion objective can hit the sample holder or need oil/water: confirm with the user first. Pixel size changes with the objective.
set_shutter 🎛 control Open or close the current shutter, and optionally switch auto-shutter. An open shutter illuminates (and bleaches) the sample until it is closed again.
snap_image 🎛 control Acquire one image with the current channel, exposure and position. The sample is illuminated during the exposure. Saves the full image as TIFF and returns summary statistics (min/max/mean, saturation, sharpness) plus an optional contrast-stretched preview.
stop_stage 🛑 safety Immediately stop XY and Z stage motion and abort any z-stack or time-lapse in progress.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. get_command_log lists every state-changing MMCore call (setPosition(1502.0), setConfig('Channel', 'FITC'), snapImage(), ...).

Safety limits

Limit Default Meaning
max_z_step_um 50 µm Largest focus move from the current position (also the largest z-stack offset, and the largest autofocus correction accepted)
max_xy_step_um 20000 µm Largest XY stage move in one call (straight-line distance)
max_exposure_ms 10000 ms Longest camera exposure
max_frames 500 Most images in one z-stack or time-lapse (slices or timepoints x channels)
max_acquisition_duration_s 3600 s Longest time-lapse

Override at launch, e.g. --limit max_z_step_um=10 --limit max_frames=2000.

Soft limits (recommended): absolute stage bounds in micrometres, set with driver options. Find them by moving to the safe extremes in Micro-Manager (e.g. Z with the objective just below the coverslip) and reading the positions:

Option Meaning
z_min_um, z_max_um Allowed focus range. Set the side that moves the objective toward the sample tightly.
x_min_um, x_max_um, y_min_um, y_max_um Allowed XY range (e.g. the area of your slide or plate holder)

Every Z and XY move, every z-stack slice and every autofocus result is checked against the step limits and soft limits before anything moves (autofocus results are checked afterwards and undone if out of range).

Example prompts

  • "What's on this microscope? List the channels and objectives, and the current position."
  • "Switch to FITC, find an exposure that uses about half the camera's range without saturating, then snap an image and show me."
  • "Autofocus, then take a z-stack from −10 to +10 µm in 1 µm steps in DAPI and FITC and tell me which slice is sharpest."
  • "Move 500 µm to the right and snap a DAPI image; repeat three more times to make a row of four fields."
  • "Record a time-lapse in TRITC every 30 s for 20 minutes and tell me how much the signal bleached."
  • "Something is wrong — stop the stage and close the shutter."

Notes

  • Objective crashes. Moving the focus drive toward the sample can drive the objective into the coverslip or dish. get_position / get_system_info report focus_direction (whether increasing Z moves the objective toward the sample, as declared by the device adapter; often unknown). Configure z_min_um / z_max_um for every microscope you connect.
  • Objective changes (set_objective) rotate the nosepiece and are marked as hazardous; set_config refuses config groups whose names look like objective or turret groups (Objective, Nosepiece, Turret, Magnification, Lens). Other groups are applied as-is: if one of your presets moves hardware near the sample, name the group accordingly or leave it out of the configuration.
  • Light exposure. With auto-shutter on (the default), the light path only opens while the camera exposes. set_shutter(open=True) leaves the sample lit until close_shutter is called.
  • Images are saved as TIFF files (ImageJ hyperstacks with pixel size, Z spacing and frame interval) in save_path, or in --option data_dir=... (default: the system temp folder, labmcp-micro-manager/). Existing files are never overwritten. Tools return statistics (min/max/mean/std, saturated fraction, a sharpness score) and a small contrast-stretched PNG preview, never the full image.
  • Acquisitions (acquire_z_stack, acquire_time_lapse) snap image by image with the current camera settings; they do not use hardware-triggered sequencing, so they are slower than Micro-Manager's MDA engine but behave identically on every device. stop_stage or close_shutter aborts them between frames; partial data is saved. A z-stack returns the focus to its starting position unless it was aborted.
  • Autofocus uses the configured autofocus device (fullFocus). Software autofocus plugins from the Micro-Manager Java app are not available.
  • pymmcore-plus is imported only when a real configuration is loaded, so --simulate works without Micro-Manager's native libraries.

Hardware verification

Microscope / camera / stage Micro-Manager adapters Interface Verified by Date
none yet: be the first

Release files for labmcp-micro-manager 0.1.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-micro-manager 0.1.0
File Size Uploaded
labmcp_micro_manager-0.1.0.tar.gz 28.4 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-micro-manager 0.1.0
File Interpreter ABI Platform
labmcp_micro_manager-0.1.0-py3-none-any.whl Python 3 none any Details

Total release size: 54.0 kB

Release files / labmcp_micro_manager-0.1.0.tar.gz

Download URL labmcp_micro_manager-0.1.0.tar.gz
Size 28.4 kB
Tags Source
SHA-256 checksum
How to use checksums
afd0e73bbd68eaa055b927d082d941f9e601fc781bba5f9c031ea40b4aba8c91
BLAKE2b-256 checksum
How to use checksums
f91dea15bc55ce228fc11531ef65e1ca058f29743093b2c0e563c33973779a04
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 25, 2026.

Transparency log

Release files / labmcp_micro_manager-0.1.0-py3-none-any.whl

Download URL labmcp_micro_manager-0.1.0-py3-none-any.whl
Size 25.6 kB
Tags Python 3
SHA-256 checksum
How to use checksums
5f892e4e2bb078d3b92dad4ad4c4c11e4bae7f31fb7a2d3d4e94ce9716af20fa
BLAKE2b-256 checksum
How to use checksums
0e382af5143254097783e2e19fa5c46c5270f14017c321ac9990e339c1c2bc13
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 25, 2026.

Transparency log

Release history Release notifications | RSS feed

This release

0.1.0 This release

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page