Modbus TCP/RTU Device — MCP Server

Let an AI agent read and control Modbus devices over Ethernet (Modbus TCP) or RS-485/RS-232 (Modbus RTU/ASCII): PID temperature controllers, recirculating chillers, PLCs, process sensors, VFDs and data loggers. You describe the device once in a register map (YAML or JSON). The agent then works with named points in real units, such as process_temperature = 37.2 °C or setpoint, instead of raw registers. The server enforces the map's rules: only writable points can be written by name, every writable number must have a min and max, and out-of-range values are refused before anything is sent. The map can also define a safe state, a list of point writes (heater off, controller to standby) that a SAFETY tool runs on request.

Package labmcp-modbus
Instruments Any Modbus device: temperature controllers (Watlow, Eurotherm, Omega, Autonics, …), chillers and circulators, PLCs and remote I/O, sensors/transmitters, VFDs, power meters, data loggers
Interfaces Ethernet (Modbus TCP, port 502), RS-485 / RS-232 (Modbus RTU or ASCII), serial-to-Ethernet gateways (RTU over TCP)
Protocol MODBUS Application Protocol Specification V1.1b3, MODBUS over Serial Line V1.02, MODBUS Messaging on TCP/IP Implementation Guide V1.0b; client via pymodbus 3.8+
Status 🧪 simulated: tested against an in-memory simulated controller and a local pymodbus server, not yet verified on hardware. Report a hardware test

What this server adds over a plain register-poking Modbus MCP:

  • Typed register maps: int16/uint16/int32/uint32/float32/float64/bool, word and byte order, scale and offset, units, enums (0 = standby, 1 = auto) and descriptions.
  • Per-point limits: writable points need min/max or an enum, and values are checked before sending. Raw writes to addresses that belong to a mapped point are refused, so the limits can't be bypassed.
  • Read-back: every write_point reads the value back and reports whether it matches.
  • Safe state: an apply_safe_state SAFETY tool, defined in the map, that works even in --read-only mode.
  • Read-only mode (--read-only), an audit log of every request and reply, and bounded request sizes.

Try it without hardware

uvx labmcp-modbus --simulate --check

The simulator is a generic single-loop PID temperature controller. Its layout is the bundled example register map. It is illustrative and not a copy of any vendor's map. A heater (3 °C/s at full power) heats a thermal mass that cools towards a 22 °C room (τ = 90 s). The PID loop has a ramping working setpoint and alarm bits. The simulator answers exception 02 for unimplemented addresses, 03 for values outside its own range (e.g. a 500 °C setpoint), and 0B for a wrong unit id. With --simulate --option register_map=my_map.yaml, points that are not in the example layout get zero-initialised storage, so you can test your own map.

Connect your device

  1. Device setup: in the device's communications menu, enable Modbus and note its settings.
    • RTU (RS-485): set the unit (slave) address (1–247), baud rate, parity and stop bits. The server defaults to the Modbus serial default of 19200 baud, 8 data bits, even parity, 1 stop bit. Many devices ship with other settings (e.g. 9600 8N1); put your device's settings in the address. Wire the USB-RS485 adapter's A/B (D−/D+) lines to the device; vendors disagree on the A/B labels, so swap them if nothing answers. Connect the signal ground, and put 120 Ω termination at both ends of longer buses.
    • TCP: set the IP address. The port is 502 unless changed. Many TCP devices ignore the unit id. If yours does not, it is usually 1; the TCP implementation guide recommends 255 for directly addressed devices.
  2. Write a register map for your device from its Modbus manual. Copy the example and see Register map below.
  3. Test the connection:
    uvx labmcp-modbus --address tcp://192.168.1.20:502 --option register_map=~/maps/oven.yaml --check
    uvx labmcp-modbus --address "serial:///dev/ttyUSB0?baudrate=9600&parity=N" --option unit_id=3 \
        --option register_map=~/maps/controller.yaml --check
    uvx labmcp-modbus --address "serial://COM4?baudrate=19200&parity=E" --option register_map=C:/maps/chiller.json --check
    uvx labmcp-modbus --address "tcp://192.168.1.30:4001?framer=rtu" --check      # RTU through a transparent gateway
    
    --check connects, reads the map's first point as a probe and prints probe: ok: … or the error. More address parameters: stopbits=2, bytesize=7, framer=ascii (Modbus ASCII), timeout=1, retries=2.

Register map

device:                 # optional
  name: Incubator oven
  manufacturer: Example
  model: X-100
  unit_id: 1            # --option unit_id overrides it
  word_order: big       # default for 32/64-bit points
  byte_order: big

points:
  chamber_temperature:
    table: input        # holding | input | coil | discrete
    address: 0          # 0-based protocol address ("30001" in the manual -> input 0)
    type: int16         # uint16 | int16 | uint32 | int32 | float32 | float64 | bool
    scale: 0.1          # value = raw * scale + offset
    unit: °C
    description: Chamber temperature
  setpoint:
    table: holding
    address: 0          # "40001" -> holding 0
    type: int16
    scale: 0.1
    unit: °C
    writable: true
    min: 20             # required for writable numbers: checked before sending
    max: 60
  mode:
    table: holding
    address: 1
    writable: true
    enum: {0: standby, 1: run}
  heater_enable:
    table: coil
    address: 0
    writable: true

safe_state:             # optional: run in order by apply_safe_state
  - {point: heater_enable, value: false}
  - {point: mode, value: standby}
Field Default Meaning
table (required) holding (FC03/06/16), input (FC04, read-only), coil (FC01/05), discrete (FC02, read-only)
address (required) 0-based protocol (PDU) address. Manual numbering: 4xxxx → holding xxxx − 1, 3xxxx → input, 1xxxx → discrete, 0xxxx → coil
type uint16 (bool for coils/discretes) 32-bit types use 2 registers, float64 uses 4. bool in a register means 0 = false, anything else = true
word_order / byte_order big / big big/big = ABCD (most significant register first). little/big = CDAB (common on PLCs). big/little = BADC. little/little = DCBA
scale, offset 1, 0 Engineering value = raw × scale + offset. Writes are rounded to the register's resolution and re-checked
unit, description "" Shown to the agent
writable false Only holding registers and coils can be writable
min, max none Engineering-unit limits. Required for writable numeric points (unless enum is used)
enum none {number: label} for integer points. Writes accept the label or the number

The server validates the map when it starts. Unknown fields (e.g. a misspelt maximum) and repeated keys (a second max, or a point defined twice) are errors rather than being silently ignored, so a typo can't remove a limit. Two writable points may not share a register (writing one would bypass the other's limits); read-only views of a writable register are fine. If the map is invalid, list_points shows the error and the device tools refuse to run. The server fails closed.

Add to your MCP client

Claude Code

claude mcp add oven -- uvx labmcp-modbus --address tcp://192.168.1.20:502 --option register_map=/home/me/maps/oven.yaml

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "controller": {
      "command": "uvx",
      "args": [
        "labmcp-modbus", "--address", "serial:///dev/ttyUSB0?baudrate=9600&parity=N",
        "--option", "unit_id=1",
        "--option", "register_map=/home/me/maps/controller.yaml",
        "--option", "raw_writes=false"
      ]
    }
  }
}

Useful flags:

  • --read-only allows reads only. apply_safe_state stays available.
  • --option raw_writes=false removes write_register, write_registers and write_coil, so the agent can only write what the map allows. This is recommended once your map is complete.

Tools

Tool Kind Description
apply_safe_state 🛑 safety Put the device into the safe state defined in the register map (e.g. heater output off, controller to standby), writing each step in order and reading it back. Every step is attempted even if an earlier one fails. Call it immediately if anything looks wrong. all_ok is true only if every step was written AND read back with the requested value; a step the device acknowledged but ignored (e.g. in local mode) is not ok.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
list_points 👁 read Describe the loaded register map: device, every named point (table, 0-based address, type, scaling, unit, writable, min/max, enum) and the safe-state steps. Works without a connection.
read_coils 👁 read Read coils (FC01): single-bit outputs such as run/stop or relay states.
read_discrete_inputs 👁 read Read discrete inputs (FC02): single-bit, read-only status such as alarms or limit switches.
read_points 👁 read Read named points from the register map, decoded and scaled into engineering units (e.g. process_temperature = 25.1 °C). A point that cannot be read gets an error instead of failing the whole call.
read_registers 👁 read Read raw holding or input registers (unsigned 16-bit), optionally decoded as int16, 32-bit or 64-bit values. For exploring a device; prefer read_points when a register map describes it.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
write_coil ⚠️ hazard Switch one raw coil (FC05). Coils often start or stop equipment (heaters, pumps, motors); mapped coils are refused here (use write_point).
write_point ⚠️ hazard Write a named point from the register map (setpoint, mode, output enable...). The value is checked against the point's writable flag, min/max or enum BEFORE sending, converted to raw registers, written, then read back. Changing setpoints and outputs acts on real equipment. If the write succeeds but the read-back fails, read_back_error says why.
write_register ⚠️ hazard Write one raw holding register (FC06). No scaling or limits are applied, so only use it for addresses the register map does not describe (mapped addresses are refused: use write_point). Returns a read-back if the register is readable.
write_registers ⚠️ hazard Write consecutive raw holding registers (FC16), e.g. both halves of a 32-bit value. No scaling or limits are applied; mapped addresses are refused (use write_point).

get_connection_info, get_command_log and reconnect are built into every LabMCP server. apply_safe_state is listed only when the register map defines a safe_state.

Safety limits

This server has no global --limit values: a generic Modbus client can't know what a register means. The protections come from the register map and the server:

Protection Where
writable: false (default) write_point refuses the point
min / max / enum per point write_point refuses out-of-range values before sending, and again after rounding to the register resolution (integer or float32)
Mapped-address protection write_register(s) / write_coil refuse any address that overlaps a mapped point
--option raw_writes=false Removes the raw write tools entirely
--read-only Removes every write tool. apply_safe_state remains
safe_state in the map apply_safe_state writes each step in order and reads it back. Every step is attempted even if one fails. A step is ok only if the read-back matches, so a device that acknowledges but ignores writes (local/keypad mode) is reported, not trusted
Request bounds 1–125 registers (FC03/04), 1–2000 bits (FC01/02), 1–123 registers (FC16) per request, as in the spec
No broadcast Unit id 0 is refused on serial lines: it would write to every device, and devices do not reply to broadcasts

Example prompts

  • "What's the chamber temperature and output power right now? Show every point with its unit."
  • "Ramp the controller to 55 °C at 2 °C/min, switch it to auto, enable the heater, and tell me when it's within 0.5 °C of setpoint."
  • "Set the high alarm to 70 °C, then check whether any alarm or sensor-fault bits are active."
  • "Read holding registers 100–109 and decode them as float32 (try both word orders). I'm mapping a new chiller."
  • "Something's wrong: put the controller in its safe state and confirm the heater is off."

Notes

  • Addresses are 0-based on the wire. Manuals often use 1-based "Modicon" numbers (40001 = holding 0). If every read is off by one register, the map uses the wrong convention.
  • Word order is not standardised for 32-bit values: the Modbus spec only defines byte order within a register. If a float or 32-bit value looks absurd, try word_order: little. read_registers with decode_as helps you find the right order.
  • A float point that reads NaN or infinity (many devices use NaN as "no value", e.g. a sensor fault) comes back with value: null and an error; read_registers with decode_as shows it as "nan"/"inf".
  • write_point uses FC06 for single-register points, FC16 for multi-register points and FC05 for coils. A few devices accept only FC16 even for single registers. For those, map the value as part of a multi-register point or report it so we can add an option.
  • Some controllers save written parameters to non-volatile memory, which survives only a limited number of write cycles. Don't have the agent rewrite setpoints in a tight loop. Check whether the manual offers a RAM-only or remote setpoint register.
  • Reading is normally side-effect free, but a few devices clear counters or alarms when they are read. Leave such registers out of the map or mark them in description.
  • Modbus TCP devices often accept only a few simultaneous connections. Close other SCADA or logging clients if the connection is refused.
  • Timeouts nearly always mean a wrong unit id, baud rate, parity or A/B wiring. Exception 02 means an address the device does not implement. Exception 03 means the device rejected the value by its own internal limits.
  • Works with pymodbus 3.8 or newer (the unit keyword changed from slave= to device_id= in 3.10; both are handled).
  • The bundled map is an illustrative example. Contributions of real device maps are welcome: include the manual title and revision the addresses came from.

Hardware verification

Model Firmware Interface Verified by Date
none yet: be the first

Release files for labmcp-modbus 0.1.2

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-modbus 0.1.2
File Size Uploaded
labmcp_modbus-0.1.2.tar.gz 36.9 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-modbus 0.1.2
File Interpreter ABI Platform
labmcp_modbus-0.1.2-py3-none-any.whl Python 3 none any Details

Total release size: 69.2 kB

Release files / labmcp_modbus-0.1.2.tar.gz

Download URL labmcp_modbus-0.1.2.tar.gz
Size 36.9 kB
Tags Source
SHA-256 checksum
How to use checksums
5be3a6f7b6de9505fe299fe1e9b3790627a980a5965f416b63544723f0201378
BLAKE2b-256 checksum
How to use checksums
9eafaf5fb8e6c28ac8fa72aa7dcda39ca3e1bca097678fd484392b159407aa47
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_modbus-0.1.2-py3-none-any.whl

Download URL labmcp_modbus-0.1.2-py3-none-any.whl
Size 32.3 kB
Tags Python 3
SHA-256 checksum
How to use checksums
07fe05407b88d91f4df5ff620a4e5b43f7ed4c84285ab22be1ff30d8e5064e8f
BLAKE2b-256 checksum
How to use checksums
acb26ba278dc531e6f8e0aa1048c0cc707bb01b3ca288fa6e9481826e11c2dd6
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

0.1.3

2 release files

This release

0.1.2 This release

2 release files

0.1.1

2 release files

0.1.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page