LC-MS Worklist Builder (MassLynx, SCIEX OS, MassHunter, Xcalibur): MCP Server

Let an AI agent build LC-MS sample queues (worklists, sequences, batches) and export them as import files for Waters MassLynx, SCIEX OS, Agilent MassHunter Acquisition and Thermo Xcalibur. The agent can lay out samples on a tray, insert blanks and QCs, randomise the run order with a recorded seed, check the list for mistakes, convert an existing file from one vendor to another, and write the file for a person to import. It uses only documented import formats. It never starts an acquisition and doesn't talk to the mass spectrometer.

Package labmcp-ms-worklist
Software Waters MassLynx 4.x, SCIEX OS, Agilent MassHunter Acquisition (LC/TQ, LC/Q-TOF), Thermo Xcalibur 2.2+
Interfaces File (writes CSV/TXT import files into one output folder)
Protocol Vendor sample-list import formats (see Formats for sources)
Status 🧪 simulated: tested with golden files and round-trip tests, not yet imported into the vendor software by us. Report a test

Try it without an instrument

uvx labmcp-ms-worklist --simulate --check

--simulate uses a temporary output folder that is deleted when the server stops. Everything else is the same code.

Set up

The "instrument address" is the output folder where worklist files are written (default ./worklists, created if missing):

uvx labmcp-ms-worklist --address "D:\Worklists" --check        # Windows acquisition PC or a shared drive
uvx labmcp-ms-worklist --address ~/lcms/worklists --check        # macOS / Linux, then copy the files over
  • The server only reads and writes inside this folder. It refuses .., absolute paths elsewhere and symlinks that point outside it. It never overwrites an existing file unless the agent passes overwrite=true.
  • To edit or convert an existing file, or to use a vendor template, copy it into the folder first.
  • Point --address at a folder the acquisition software watches only if the vendor documents that behaviour for your setup. Otherwise import the file by hand (instructions below).

Add to your MCP client

Claude Code

claude mcp add ms-worklist -- uvx labmcp-ms-worklist --address ~/lcms/worklists

Claude Desktop / Cursor / Windsurf

{
  "mcpServers": {
    "ms-worklist": { "command": "uvx", "args": ["labmcp-ms-worklist", "--address", "/path/to/worklists"] }
  }
}

--read-only keeps only the tools that inspect things (list_formats, validate_worklist, import_worklist, get_worklist, list_worklists).

Tools

Tool Kind Description
add_samples 🎛 control Append samples to a draft worklist (the worklist's defaults and automatic positions apply; any blank/QC/randomisation plan is re-applied to the longer list with the same seed).
create_worklist 🎛 control Create an in-memory draft worklist from a sample list plus defaults (methods, injection volume, tray positions, data-file naming pattern). Nothing is written to disk until export_worklist. Injection volumes above the max_injection_volume_ul limit are refused.
export_worklist 🎛 control Validate the draft and write the vendor import file into the output folder. Returns the path, a preview of the first lines, warnings and import instructions. Refuses if validation finds errors or the file exists (unless overwrite=true). This does not start an acquisition: a person imports the file into the acquisition software.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_worklist 👁 read Show a draft worklist in run order, with its defaults, blank/QC plan, randomisation seed and the history of operations applied to it.
import_worklist 👁 read Parse an existing MassLynx, SCIEX OS, MassHunter or Xcalibur import file from the output folder into a draft, so it can be validated, edited or exported in another vendor's format. Columns without a neutral equivalent are kept verbatim. Only reads; nothing is written.
insert_qc_blanks 🎛 control Insert blanks and QC injections and optionally randomise the run order (with a recorded seed). Replaces any previous plan, so calling it again does not duplicate blanks. The plan is re-applied whenever samples are added; data-file names follow the new run order.
list_formats 👁 read List the supported import formats (Waters MassLynx, SCIEX OS, Agilent MassHunter, Thermo Xcalibur): columns, required fields, sample-type names, file extensions, how to import, what is verified against vendor documents and what is assumed, and the source URLs. Also lists the position patterns and the formats that were researched but not implemented.
list_worklists 👁 read List the draft worklists in memory and the files in the output folder.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
validate_worklist 👁 read Check a draft against the target format: required fields, duplicate data-file names, characters Windows does not allow in file names, tray/vial position format and plate bounds, injection volume (> 0 and <= the max_injection_volume_ul limit), and method file extensions. Errors block export; warnings don't.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. There are no HAZARD tools: nothing here moves, heats, injects or acquires. The server only writes files. The CONTROL tools change in-memory drafts or write a file, and --read-only hides them.

Typical flow: create_worklist → add_samples (optional) → insert_qc_blanks → validate_worklist → export_worklist, then import the file in the vendor software.

Formats

The table below separates what the vendor documents say (verified) from what the server assumes. list_formats returns the same information to the agent. To be sure of the header for your software version, export an empty batch, sequence or worklist from your own system, put it in the output folder, and pass it to export_worklist as template_path. The server then writes that header, and that delimiter, exactly.

Waters MassLynx: sample list worksheet (waters_masslynx)

  • Import: Sample list > File > Import Worksheet, File of Type "Comma Delimited (*.CSV, *.TXT)".
  • Verified:
    • Row 1 holds the MassLynx FIELD IDs, which are case sensitive. Columns can be in any order, and an Index column is added. Source: WKB63781.
    • The required columns are FILE_NAME, INLET_FILE, MS_FILE, SAMPLE_LOCATION and INJ_VOL. Source: MassLynx 4.2 Getting Started Guide 715009602, Table 5-1. The "Bottle" column's FIELD ID is SAMPLE_LOCATION, not BOTTLE.
    • The example files attached to WKB63781 use CRLF line endings and unquoted fields, TYPE values Blank/Standard/QC/Analyte, and method names without an extension.
  • Mapping: FILE_NAME = data file, FILE_TEXT = sample name, MS_FILE, MS_TUNE_FILE, INLET_FILE, SAMPLE_LOCATION, TYPE, ID, INJ_VOL, Index. You can add any other FIELD ID (for example CONC_A or QUAN_REF) per sample through extra.
  • Assumed:
    • solvent and double_blank are written as Blank.
    • Extension checks: .exp for MS_FILE and .ipr for the tune file, applied only when an extension is given.
    • Files are UTF-8 without a BOM. Non-ASCII text is flagged.
    • The waters_plate_well position pattern (1:A,1) is a common convention. Its comma is CSV-quoted.

SCIEX OS: batch import (sciex_os)

  • Import: Batch workspace > Open > Import from file, then Save As.
  • Verified:
    • Batches import from .txt or .csv, and the column layout must come from a batch exported from SCIEX OS. Source: SCIEX KB.
    • Column names Sample Name (< 252 characters), MS Method, Sample Type, Data File and Processing Method. Source: SCIEX OS Feature Guide RUO-IDV-05-15796-C, Table 4-1.
    • Rack Type, Rack Position, Plate Type, Plate Position and Vial Position columns. Source: SCIEX KB.
    • Sample types Unknown, Blank, Standard, QualityControl, Solvent and Double blank.
    • Several samples can share one data file.
  • Assumed:
    • SCIEX doesn't publish the exact header text of an exported batch. The default header (Sample Name,Sample ID,Sample Type,MS Method,LC Method,Rack Type,Rack Position,Plate Type,Plate Position,Vial Position,Injection Volume,Data File,Processing Method,Comment) is a best guess. Use template_path with your own export. validate_worklist and export_worklist warn when no template was used.
    • Extensions .msm, .lcm and .qmethod produce warnings only.
    • Rack and plate columns are set with vendor_columns or per sample with extra.

Agilent MassHunter Acquisition: worklist CSV import (agilent_masshunter)

  • Import: Worklist, right-click > "Add/Append Samples from... (csv, xlsx)". Older versions call it "Import Worklist...". You don't need a map file because the headers match the worklist column names.
  • Verified:
    • The header Sample Name,Barcode,Rack Code,Sample Position,Method,Data File,Sample Type,Level Name,Inj Vol (µL),Comment, positions like P1-A1, and the types Calibration and Sample come from the example file shipped in D:\MassHunter\Worklist_Import, as quoted on the Agilent Community.
    • Save as UTF-8 when the file contains µ. Source: Agilent Community.
    • Inj Vol = -1 means "As method". Source: Agilent Known Problem Report.
    • Sample Position, Method and Data File must be filled in. Source: Study Manager Quick Start G3335-90140.
  • Assumed:
    • The file has a UTF-8 BOM and CRLF line endings.
    • Data files get a .d suffix.
    • Methods should end in .m.
    • The sample types Blank, QC and DoubleBlank don't appear in the example; solvent is written as Blank.

Thermo Xcalibur: sequence CSV import (thermo_xcalibur)

  • Import: Sequence Setup > File > Import Sequence.
  • Verified in the Xcalibur 2.2 Acquisition and Processing User Guide XCALI-97209 Rev. D, Appendix A:
    • Only .csv files are accepted.
    • The first cell must be Bracket Type=n (1 Overlapped, 2 None, 3 Non-Overlapped, 4 Open).
    • The separator must match the Windows list separator. Use delimiter=";" where that is ;.
    • The sequence column names and the sample types Unknown, Blank, QC, Std Bracket, Std Clear and Std Update.
  • Corroborated, not published by Thermo: the exact row-2 header strings (Sample Type,File Name,Sample ID,Path,Instrument Method,Process Method,Calibration File,Position,Inj Vol,Level,Sample Wt,Sample Vol,ISTD Amt,Dil Factor,L1 Study,L2 Client,L3 Laboratory,L4 Company,L5 Phone,Comment,Sample Name). Open-source generators that target Xcalibur import use them: protti, fgcz/qg and lcms-sequencer. Native exports start with a bare Bracket Type=4 line (Rapid-QC-MS #83). Export one sequence from your Xcalibur as a template if you want certainty.
  • Assumed:
    • Sample Wt 0, Sample Vol 0, ISTD Amt 0 and Dil Factor 1 are written as defaults.
    • standard is written as Std Bracket, which suits bracket type 4.
    • Extension checks: .meth for the instrument method and .pmd for the processing method.

Not implemented

  • MassHunter Walkup Custom Sample Import (G2725-90026): the guide couldn't be retrieved (HTTP 403), so its format couldn't be verified.
  • Native worklist and sequence files (MassHunter .wkl XML, Xcalibur .sld, MassLynx .spl): not implemented. We found no public specification for them, so the server uses the CSV import paths above.

Validation

validate_worklist, which export_worklist also runs, reports errors, which block export, and warnings:

  • Required fields for the format are missing.
  • Duplicate data-file names, compared case-insensitively. For SCIEX OS a shared data file is allowed, but a sample name repeated within one data file is an error.
  • Characters Windows doesn't allow in file names (< > : " / \ | ? *, control characters), a trailing dot or space, and reserved names (CON, NUL, COM1…).
  • The position doesn't match the chosen position_pattern (vial_number, well, agilent_plate_well, waters_plate_well, tray_well) or falls outside the plate_size (24/48/54/96/384) or max_vial.
  • The injection volume is ≤ 0, not a number, or above the max_injection_volume_ul limit. This includes injection-volume columns set through extra or vendor_columns.
  • A text field or extra value contains a line break or another control character, which would break the import file.
  • The method file has the wrong extension, for example an Analyst .dam in a SCIEX OS batch, or a MassHunter .m in an Xcalibur sequence.
  • Fields the target format has no column for, and non-ASCII text in formats without a BOM.

Safety limits

Limit Default Meaning
max_injection_volume_ul 100 µL Largest injection volume allowed in a worklist. Enforced when samples are added and again at export, including volume columns set verbatim through extra or vendor_columns. import_worklist warns about larger volumes, and such a draft can't be exported.

Override at launch, for example --limit max_injection_volume_ul=20 for a 20 µL loop.

Example prompts

  • "Make an Xcalibur sequence for the 40 plasma samples in this list: wells A1 onwards on the R tray, 2 µL, method C:\Xcalibur\methods\DIA_60min. Add a blank after every 10 samples from R:H12 and a pooled QC at the start and end from R:H11. Randomise the samples and tell me the seed."
  • "Import old_batch.csv from the worklist folder and convert it to a MassHunter worklist with method D:\MassHunter\methods\Panel.m."
  • "I put blank_batch.txt (exported from our SCIEX OS) in the folder. Use it as the template for this batch."
  • "Check this MassLynx sample list for duplicate file names and bad vial positions before I import it."

Notes

  • Drafts live in memory. reconnect (or restarting the server) discards them. In --simulate it also deletes the temporary folder. Export files you want to keep.
  • By default, export_worklist also writes <file>.provenance.json next to the worklist (for example Plasma.csv.provenance.json). Like the worklist itself, it is never overwritten unless overwrite=true. It contains the operation history, the randomisation seed and the sample order before randomisation, so the run order can be reproduced. Pass write_provenance=false to skip it.
  • blank_every_n / qc_every_n also add a control after the last sample when the count divides evenly, unless blank_at_end / qc_at_end already adds one there.
  • When a draft is exported in another vendor's format, values kept verbatim from the original vendor for columns the new vendor maps itself (for example Xcalibur's Std Clear sample type) are not copied; the export notes say so.
  • Randomisation shuffles only the types in randomize_types (by default unknown samples) among their own slots, using Python's random.Random(seed). Standards, blanks and QCs stay where they are.
  • Method names must match methods that exist on the acquisition PC. The server can't check that.

Verification

Software Version Format Verified by Date
none yet: be the first

Release files for labmcp-ms-worklist 0.1.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-ms-worklist 0.1.0
File Size Uploaded
labmcp_ms_worklist-0.1.0.tar.gz 42.9 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-ms-worklist 0.1.0
File Interpreter ABI Platform
labmcp_ms_worklist-0.1.0-py3-none-any.whl Python 3 none any Details

Total release size: 80.5 kB

Release files / labmcp_ms_worklist-0.1.0.tar.gz

Download URL labmcp_ms_worklist-0.1.0.tar.gz
Size 42.9 kB
Tags Source
SHA-256 checksum
How to use checksums
a7c7f3426777ad263ca9c38688685df2b2bdaced6fce6c3557afb9cdd9129fc6
BLAKE2b-256 checksum
How to use checksums
1d17f864c778a748189979ed9e1ad9b0c5ce4b74fd4cb36fa3f0ab1c2d6b7f75
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_ms_worklist-0.1.0-py3-none-any.whl

Download URL labmcp_ms_worklist-0.1.0-py3-none-any.whl
Size 37.7 kB
Tags Python 3
SHA-256 checksum
How to use checksums
f4384f275f6e072c0b81e32d368fb50e609adecdb91610ccef2d5241eef3d65f
BLAKE2b-256 checksum
How to use checksums
bf328f4f6a87123c60fc0bd988ea1180f27c4ff255b4c701c836ece925b5de73
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

0.1.1

2 release files

This release

0.1.0 This release

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page