NI-DAQmx DAQ Devices — MCP Server

Let an AI agent acquire voltages and thermocouple temperatures, read digital lines and (with your permission) set analog and digital outputs on National Instruments DAQ hardware through the official NI-DAQmx driver and its Python API.

Package labmcp-ni-daqmx
Instruments NI-DAQmx devices: USB-6001/6002/6003, USB-6008/6009, USB-6211/6212/6218, USB/PCIe M and X Series (62xx/63xx), CompactDAQ C Series modules (e.g. NI 9201, 9211, 9263, 9401), NI MAX simulated devices
Interfaces USB, PCI/PCIe, PXI, Ethernet (cDAQ chassis)
Protocol NI-DAQmx via the nidaqmx Python API (API docs, source, NI-DAQmx driver)
Status 🧪 simulated: tested against a simulated nidaqmx backend, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-ni-daqmx --simulate --check

The built-in simulator is a USB-6341-like X Series device Dev1: a 1 V / 50 Hz sine on ai0, a 2.5 V sensor on ai1, ao0/ao1 looped back to ai2/ai3, a ~37 °C thermocouple on ai4, and an external "interlock" holding port1/line0 high. It reproduces NI-DAQmx behaviour such as error codes (e.g. -200170 channel does not exist, -200576 no built-in CJC) and the shapes task.read() returns.

Testing the real NI-DAQmx path without hardware: in NI MAX (Windows) choose Devices and Interfaces → Create New… → Simulated NI-DAQmx Device, then run the server without --simulate against that device, e.g. --address SimDev1. NI MAX simulated devices return synthetic data, and get_connection_info reports ni_max_simulated_device: True. On Linux, simulated-device support is limited (NI's configuration tools can import a configuration file that defines one, with mixed results); use --simulate there.

Connect your instrument

  1. Install NI-DAQmx (Windows or Linux; macOS is not supported by NI-DAQmx) from ni.com. The nidaqmx Python package is installed with this server; python -m nidaqmx installdriver can also install the driver.
  2. Find the device name in NI MAX (Devices and Interfaces) or with nilsdev on Linux, e.g. Dev1 or cDAQ1Mod1. Close NI MAX test panels before connecting.
  3. Test the connection:
    uvx labmcp-ni-daqmx --check                    # works if exactly one device is present
    uvx labmcp-ni-daqmx --address Dev1 --check
    
    --address is the NI-DAQmx device name. It is optional when exactly one device exists.

Add to your MCP client

Claude Code

claude mcp add ni-daq -- uvx labmcp-ni-daqmx --address Dev1

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "ni-daq": {
      "command": "uvx",
      "args": ["labmcp-ni-daqmx", "--address", "Dev1"]
    }
  }
}

Add --read-only to allow acquisitions but block the output tools (set_outputs_safe stays available). Add --option safe_do_lines=port0/line0:3 to make set_outputs_safe always drive those lines low. For other clients, generate the snippet with uvx labmcp config ni-daqmx --address Dev1 --client vscode (also cursor, codex, claude-code).

Tools

Tool Kind Description
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info 👁 read Describe the connected device: analog input/output channels, digital lines, supported voltage ranges, maximum sample rates, and the outputs this server has set. Call this before choosing channels, ranges and rates.
list_devices 👁 read List every NI-DAQmx device the driver can see (product type, serial number, channels, whether it is an NI MAX simulated device) and which one this server is connected to.
read_analog 👁 read Measure voltage on one or more analog inputs: a single on-demand reading, or a finite hardware-timed acquisition of samples per channel at rate_hz. Returns per-channel statistics and a downsampled waveform; optionally saves all data to CSV.
read_digital_lines 👁 read Read the logic level of digital lines.
read_thermocouple 👁 read Measure temperature (°C) with thermocouples (types B, E, J, K, N, R, S, T) on a thermocouple-capable device, e.g. an NI 9211/9212/9213/9214 module or USB-TC01.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
set_outputs_safe 🛑 safety Put the device's outputs in a safe state: every analog output to 0 V (or the bottom of its range if 0 V is not in it) and, by default, every digital line this server drove - plus the safe_do_lines option lines - driven low. Use when finished or if anything looks wrong.
write_analog ⚠️ hazard Set an analog output to a DC voltage (static, software-timed). The output keeps this value after the call on most NI devices, until changed or set_outputs_safe is called.
write_digital_lines ⚠️ hazard Drive digital output lines high or low. The lines keep their level after the call until changed or set_outputs_safe is called.

get_connection_info, get_command_log and reconnect are built into every LabMCP server. The command log records every task the server ran (channels, ranges, rates, values written).

Safety limits

Limit Default Meaning
max_ao_voltage_v 5 V Largest |voltage| an agent may put on an analog output
max_samples 100 000 Most samples per channel in one acquisition
max_rate_hz 100 000 Hz Highest sample clock rate per channel
max_acquisition_s 60 s Longest finite acquisition (samples / rate)

Override at launch, e.g. --limit max_ao_voltage_v=10 --limit max_acquisition_s=300. Limits are checked before anything is sent. The device's own AO range is also enforced (e.g. USB-6008/6009 outputs 0-5 V only), as are its maximum sample rates.

Example prompts

  • "List the NI devices and tell me which inputs Dev1 has and their voltage ranges."
  • "Acquire ai0 and ai1 differentially at 10 kHz for 0.5 s on the ±1 V range and give me the RMS noise of each; save the data to ~/daq/noise.csv."
  • "Read the type K thermocouples on cDAQ1Mod1/ai0:3 once a second for 30 seconds using the built-in CJC and report the average of each."
  • "Set ao0 to 2.0 V, confirm it on the ai2 loopback, then set it back to 0."
  • "Is the interlock on port1/line0 closed? Then switch port0/line2 high to open the valve."
  • "We're done: put every output in a safe state."

Notes

  • Every tool call is one short DAQmx task (create channels, configure timing, read or write, close), as in NI's examples, so the server never holds the device reserved between calls. Another program using the device at the same time causes a clear "resource reserved" error (-50103). Output and digital-line tasks are serialised separately from acquisitions, so set_outputs_safe (and write_analog) never wait for a running acquisition to finish: NI-DAQmx runs an analog-input task and AO/DIO tasks on the same device side by side.
  • Acquisitions are capped at 600 s per tool call even if max_acquisition_s is raised. The returned waveform is downsampled by keeping each block's minimum and maximum, so short spikes are not lost. save_path must be a new .csv file: it is checked before acquiring, and an existing file is never overwritten.
  • Outputs hold their value after the task closes on most NI devices, which is what the output tools rely on. Some devices have configurable idle/power-up output behaviour; check your device if it resets outputs.
  • Reading a digital line can change it. A DAQmx digital-input task configures the line as an input. The server therefore reports lines it is driving from their last commanded level instead of reading them, and documents the risk for lines driven by other software.
  • Terminal configuration matters. default lets NI-DAQmx choose (often differential where supported). A wrong choice gives offsets or noise rather than an error.
  • Thermocouples use add_ai_thrmcpl_chan with built-in or constant cold-junction compensation. A CJC channel (SCANNABLE_CHANNEL) is not offered in this version because its correct use depends on the device.
  • Rates: multiplexed devices share ai_max_multi_channel_rate_hz across channels, and NI-DAQmx coerces the sample clock to a rate the timebase can produce. The actual rate is returned in sample_rate_hz.
  • NI-DAQmx warnings (e.g. about coerced values) are returned in each acquisition's warnings list.

Hardware verification

Model NI-DAQmx version Interface Verified by Date
none yet: be the first

Release files for labmcp-ni-daqmx 0.1.1

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-ni-daqmx 0.1.1
File Size Uploaded
labmcp_ni_daqmx-0.1.1.tar.gz 26.0 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-ni-daqmx 0.1.1
File Interpreter ABI Platform
labmcp_ni_daqmx-0.1.1-py3-none-any.whl Python 3 none any Details

Total release size: 50.9 kB

Release files / labmcp_ni_daqmx-0.1.1.tar.gz

Download URL labmcp_ni_daqmx-0.1.1.tar.gz
Size 26.0 kB
Tags Source
SHA-256 checksum
How to use checksums
a71a5d9f94ef11f10d244f5e774dfd0202400f895126fd16ab5274f7a0580683
BLAKE2b-256 checksum
How to use checksums
3ed61766f08da436b7777a58fc13a9d14ee0acb534e94ce959da1c388dc78e6d
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_ni_daqmx-0.1.1-py3-none-any.whl

Download URL labmcp_ni_daqmx-0.1.1-py3-none-any.whl
Size 24.9 kB
Tags Python 3
SHA-256 checksum
How to use checksums
1af50ea33ea9e0376ce2ea2e98046b4917e641d1ae6ccf4bef16d59e526de69d
BLAKE2b-256 checksum
How to use checksums
6dd095a0484fd92253c8d7cb94c3131a8d9f196e73a9120e008516513f461290
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

0.1.2

2 release files

This release

0.1.1 This release

2 release files

0.1.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page