PalmSens Potentiostat — MCP Server

Let an AI agent run cyclic voltammetry, linear sweep voltammetry, differential pulse voltammetry and chronoamperometry on PalmSens potentiostats that speak MethodSCRIPT, and get back downsampled data, peak summaries and optional full-resolution CSV files.

Package labmcp-palmsens
Instruments EmStat Pico (module and development board), EmStat4 LR/HR (EmStat4S, EmStat4M, EmStat4X), Sensit Wearable / Sensit BT, Nexus
Interfaces USB (virtual COM port), UART
Protocol MethodSCRIPT v1.x (MethodSCRIPT manual v1.8) over the PalmSens online communication protocol (EmStat Pico v1.6, EmStat4 v1.3); cross-checked against PalmSens/MethodSCRIPT_Examples
Status 🧪 simulated: tested against a wire-level simulator, not yet verified on hardware. Report a hardware test

Try it without hardware

uvx labmcp-palmsens --simulate --check

The simulator is an EmStat Pico with a 3 mm disk electrode in 1 mM of a reversible one-electron redox couple (E° = +0.20 V, like ferro/ferricyanide vs Ag/AgCl). It interprets the scripts the server sends and streams correctly encoded data packages, so you get a proper CV "duck", DPV peaks and Cottrell decays. Simulated time runs 10× faster than real time; change that with --option sim_speed=1 (real time) or =100.

Connect your instrument

  1. Close PSTrace / MultiTrace. Only one program can hold the serial port.
  2. Find the port: uvx labmcp ports. An EmStat Pico development board or Sensit shows up as a USB serial port (FTDI). An EmStat4 or Nexus shows up as a virtual COM port named after the device.
  3. Test the connection:
    uvx labmcp-palmsens --address /dev/ttyUSB0 --check            # EmStat Pico / Sensit (Linux)
    uvx labmcp-palmsens --address /dev/tty.usbmodemXXXX --check   # EmStat4 (macOS)
    uvx labmcp-palmsens --address COM7 --check                    # Windows
    
    Defaults are the EmStat Pico's: 230400 baud, 8N1, XON/XOFF, LF line endings. Over USB the EmStat4 and Nexus ignore the baud rate. For an EmStat4 UART connection use serial://COM7?baudrate=921600&rtscts=true&xonxoff=false.
  4. --check sends the firmware-version (t) and serial-number (i) commands and prints the model, firmware and serial.

Add to your MCP client

Claude Code

claude mcp add potentiostat -- uvx labmcp-palmsens --address /dev/ttyUSB0

Claude Desktop / Cursor / Windsurf (claude_desktop_config.json, .cursor/mcp.json, …)

{
  "mcpServers": {
    "potentiostat": {
      "command": "uvx",
      "args": ["labmcp-palmsens", "--address", "/dev/ttyUSB0"]
    }
  }
}

Add --read-only to allow device information only: every measurement tool applies potential and is hidden.

Tools

Tool Kind Description
abort_measurement 🛑 safety Abort the running measurement or script immediately (communication command Z) and make sure the cell is switched off. Safe to call when nothing is running.
get_command_log 👁 read Return the most recent raw commands sent to / replies received from the instrument (newest last). Useful for debugging and for recording what was done.
get_connection_info 👁 read Report which instrument is connected (identity, address, simulated or real), whether the server is read-only, and the active safety limits. Call this first.
get_device_info 👁 read Identify the potentiostat (model, firmware, serial number) and list its potential window, PGStat modes and current ranges, so measurement parameters can be chosen within them.
reconnect 🛑 safety Close and re-open the connection to the instrument (e.g. after it was power cycled or a cable was re-plugged).
run_chronoamperometry ⚠️ hazard Hold the cell at potential_v for run_time_s and record the current every interval_s. Returns the data (time from the instrument timer) plus first/last/mean current and the charge. Applies potential to the cell.
run_cyclic_voltammetry ⚠️ hazard Run a cyclic voltammogram: begin -> vertex 1 -> vertex 2 -> begin, n_scans times, and return potential/current/time data with the anodic and cathodic peaks of every scan. Applies potential to the cell for the whole scan; the cell is switched off at the end.
run_differential_pulse_voltammetry ⚠️ hazard Run differential pulse voltammetry (current = forward - reverse, per step) from begin to end potential and return the data with the peak current and peak potential. The scan rate must be below step / pulse_time / 2. Applies potential to the cell.
run_linear_sweep_voltammetry ⚠️ hazard Run a linear sweep voltammogram from begin_potential_v to end_potential_v and return the data with the largest/smallest current and where they occur. Applies potential to the cell.
run_methodscript ⚠️ hazard Advanced: run a raw MethodSCRIPT and return its raw output and decoded data packages. Literal potentials of set_e / set_range_minmax da and the CV, LSV, DPV, SWV, NPV, ACV, CA, PAD, EIS and fast CV/CA techniques are checked against max_potential_v, and literal set_range ba / set_autoranging ba currents against max_current_range_a; values computed at run time are not. Aborted after timeout_s; add on_finished: + cell_off to your script so the cell is switched off after an abort. After a runtime error, a timeout or abort_measurement the server switches the cell off itself.

Safety limits

Limit Default Meaning
max_potential_v 2.0 V Largest absolute potential vs RE any technique (or literal in a raw script) may apply, including DPV pulses
max_current_range_a 0.01 A Highest current range an agent may select (with autorange, the instrument never goes above current_range_a); in raw scripts, literal set_range ba / set_autoranging ba values
max_duration_s 600 s Longest measurement (including equilibration) or raw-script timeout

Override at launch, e.g. --limit max_potential_v=1.0 --limit max_duration_s=1800. Whatever the limits say, a single tool call is capped at one hour.

Example prompts

  • "Run a CV of my ferrocyanide sample from −0.2 V to +0.6 V and back at 50 mV/s, three cycles, and tell me E½ and the peak separation."
  • "Do a scan-rate study: CVs at 25, 50, 100 and 200 mV/s between −0.1 and 0.5 V, save each as CSV, and check whether the peak current scales with √v."
  • "Run DPV from 0 to 0.6 V with 50 mV pulses and report the peak potential and height."
  • "Hold 0.5 V for 60 s, record the current every 0.2 s, and give me the total charge passed."
  • "Which potential window and current ranges does this potentiostat support?"
  • "Abort the measurement."

Notes

  • What the server sends. Each technique is one MethodSCRIPT modelled on PalmSens' measurement-loop examples: set_pgstat_chan 0, set_pgstat_mode, set_max_bandwidth, set_range_minmax da, set_range ba, set_autoranging ba, set_e, cell_on, optional wait, then meas_loop_cv / lsv / dpv / ca with pck_add of the set potential and current, and on_finished: cell_off. So the cell is switched off after completion and after an abort. A runtime error skips on_finished: (MethodSCRIPT manual §10.1), so after one the server sends a separate cell_off script. The exact script is in get_command_log.
  • PGStat mode and bandwidth. Max bandwidth is 6× the data rate (the ratio PalmSens' examples use). On the EmStat Pico and Sensit, the server picks low speed (−1.25 to 2.0 V, 2.2 V window, ≤ 100 Hz), then max range (−1.7 to 2.0 V, 2.6 V window), then high speed (1.214 V window) to fit your potentials. If none fits, it says why before anything is sent. EmStat4 and Nexus use low speed mode; per the manual, the modes do not differ on those instruments.
  • Current sign and units. Anodic (oxidation) current is positive; potentials are the set potentials vs RE; time_s comes from the instrument timer for chronoamperometry and from step/scan rate for sweeps.
  • Summaries. CV peaks are the raw maximum and minimum current of each scan (no baseline correction). ΔEp and the midpoint are estimates. Staircase sampling makes ΔEp somewhat larger than the ideal 59 mV at large steps.
  • Raw scripts. run_methodscript checks literal potentials (and store_var literals) of set_e, set_range_minmax da and the CV/LSV/DPV/SWV/NPV/ACV/CA/PAD/EIS loops and meas_fast_cv/meas_fast_ca against max_potential_v (DPV pulse and 2x SWV amplitude included). Literal current ranges of set_range ba / set_autoranging ba are checked against max_current_range_a. Values computed inside the script are not checked. The script is aborted at timeout_s and a cell_off script is run.
  • Abort. abort_measurement sends the communication-protocol Z command. A running technique returns the data measured so far with aborted: true. Afterwards (and when nothing was running) the server runs a one-line cell_off script, so the cell is also switched off after a raw script without on_finished:. If the output of a running script cannot be read (e.g. a USB glitch), the server aborts the script and switches the cell off before reporting the error; a single corrupted data line is skipped with a warning instead.
  • Saving data. save_path must end in .csv; missing folders are created and an existing file is never overwritten (choose a new name). The path is checked before the measurement starts. Points with a nan value are left out (with a warning).
  • Not covered: galvanostatic techniques, EIS, SWV/NPV/PAD, multiplexers, bipotentiostat mode, multi-channel MultiEmStat4 systems and the CRC16 protocol extension. Use run_methodscript for single-channel scripts beyond the built-in techniques.

Hardware verification

Model Firmware Interface Verified by Date
none yet: be the first

Release files for labmcp-palmsens 0.1.3

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for labmcp-palmsens 0.1.3
File Size Uploaded
labmcp_palmsens-0.1.3.tar.gz 33.0 kB Details

Built distribution (wheel)

Table of built distributions (wheels) for labmcp-palmsens 0.1.3
File Interpreter ABI Platform
labmcp_palmsens-0.1.3-py3-none-any.whl Python 3 none any Details

Total release size: 62.7 kB

Release files / labmcp_palmsens-0.1.3.tar.gz

Download URL labmcp_palmsens-0.1.3.tar.gz
Size 33.0 kB
Tags Source
SHA-256 checksum
How to use checksums
826c4f3c35e9c9917469fb42a3570a3a3dbb5f7d93782fd71d98470210acfe28
BLAKE2b-256 checksum
How to use checksums
1e66187b2eee8807190fe05c3e06ddcddd3787dca0e7e949ee90dfc4dd6902cf
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release files / labmcp_palmsens-0.1.3-py3-none-any.whl

Download URL labmcp_palmsens-0.1.3-py3-none-any.whl
Size 29.7 kB
Tags Python 3
SHA-256 checksum
How to use checksums
09ecf6482ac475cd3e9d3d3b43d3063b73536d04baec12ddc5365e0ee38abf75
BLAKE2b-256 checksum
How to use checksums
d48b2de01e4ecc45ddd78f70772ffeaba8bc62fd48d804cbca17030759b14008
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
Yes
Uploaded via twine/7.0.0 CPython/3.13.14

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

PyPI Publish Attestation

PyPI verified that this artifact, at this checksum, originated from the publisher listed below.

Signed by GitHub Actions, verified by PyPI on Sep 26, 2026.

Transparency log

Release history Release notifications | RSS feed

This release

0.1.3 This release

2 release files

0.1.2

2 release files

0.1.1

2 release files

0.1.0

2 release files

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page