mstrial
Trial design and endpoints for MS, on top of msclinical: endpoints from plain tables, sample size for lesion counts, MRI schedules, power for PIRA endpoints through the whole pipeline, and what registered trials actually measure.
pip install mstrial
mstrial <tool> --help
| Tool | Command | What it does |
|---|---|---|
endpoints |
mstrial endpoints |
ARR, time to confirmed worsening, NEDA-3 and new-lesion rate in one call |
lesionpower |
mstrial lesionpower |
negative binomial sample size for lesion-count endpoints |
scanplan |
mstrial scanplan |
MRI schedule under a scan budget, with transient enhancement modelled |
pirapower |
mstrial pirapower |
power for PIRA endpoints through rating noise, confirmation and attribution |
registry |
mstrial registry |
endpoint landscape of registered MS trials, live from ClinicalTrials.gov |
Research software, not a medical device. MIT licence. Each section below keeps the tool's own results and the corrections that three independent reviews made to them.
endpoints
formerly msendpoints
The standard MS trial endpoints from four plain tables, in one call: annualised relapse rate with a negative binomial rate ratio and 95 % CI, time to confirmed disability worsening (EDSS-plus or EDSS, via edssplus) with Kaplan-Meier and log-rank, NEDA-3 over year one (via neda, assessable patients only) and new T2 lesions per patient-year.
pip install mstrial
mstrial endpoints patients.tsv visits.tsv relapses.tsv --mri mri.tsv --horizon 2
patients.tsv: patient, arm, start, end. The output is one JSON a statistician can check line by line.
An arm with no events gets rates and a stated reason, never a rate ratio of zero with a made-up interval.
lesionpower
Sample size and power for multiple sclerosis trials whose endpoint is a count of new lesions. Counts per patient are overdispersed, so a Poisson calculation promises too few patients. lesionpower fits a negative binomial to pilot counts and gives the closed-form sample size (Keene et al. 2007; Zhu and Lakkis 2014), with a simulation check for small counts.
pip install mstrial
mstrial lesionpower fit pilot.tsv --column new --exposure years # mean, dispersion, n per arm for 30/50/70 %
mstrial lesionpower n --mu 4.2 --k 1.3 --reduction 0.5 --simulate
What the pilot data does to the answer
On the 24 longitudinal MSLesSeg patients (expert masks, new lesions from mscard, per patient-year of follow-up): mean 4.2 new lesions per year, dispersion k = 1.33, and not one patient with zero. A 50 % reduction then needs 37 patients per arm for 80 % power at one year.
The same data carries a warning. gtdrift finds that about half the lesion sites in MSLesSeg's multi-visit ground truth appear and disappear in ways a chronic lesion does not, so part of the "new lesion" count is annotation, not disease. A mean inflated by annotation noise makes the sample size look smaller than it is. Fit on counts from the reading protocol the trial will use.
scanplan
Monthly scans or more patients? For a gadolinium-enhancing lesion endpoint the answer is not obvious: enhancement lasts about three weeks, so a sparse schedule misses most enhancing lesions, while a dense one spends the scan budget on few patients. scanplan models that trade-off (negative binomial lesion counts, exponential enhancement duration, Keene et al. 2007 power) and returns the schedule with the highest power for a fixed number of scans. For new T2 lesions, which persist, fewer scans and more patients always win.
pip install mstrial
mstrial scanplan --budget 600 --years 1 --lam 4.2 --k 1.33 --reduction 0.3 # enhancing lesions
mstrial scanplan --budget 600 --years 1 --lam 4.2 --k 1.33 --reduction 0.3 --endpoint t2
With 600 scans, 4.2 new lesions per patient-year and dispersion 1.33 (the MSLesSeg pilot fit from lesionpower), for a 30 % reduction on enhancing lesions:
interval_days scans_per_patient years_covered patients_per_arm detect_p control_mean_count power
30 13 0.986 23 0.532 2.203 0.184
60 7 0.986 42 0.330 1.366 0.247
91 5 0.997 60 0.228 0.953 0.278
182 3 0.997 100 0.115 0.483 0.286
365 2 0.999 150 0.058 0.241 0.250
best: every 182 days, 100 per arm, power 0.29
Under this much between-patient overdispersion the 2/k term dominates the variance, so even for a
transient endpoint more patients scanned twice beat fewer patients scanned monthly. With counts close to
Poisson (--k 20) the optimum moves to quarterly scans with fewer patients.
The model and its assumptions (one enhancement duration for all lesions, no seasonal or treatment effect
on duration) are in mstrial/scanplan/core.py. Research software. MIT.
pirapower
PIRA (progression independent of relapse activity) is becoming a trial endpoint. Its power is usually computed as if the true PIRA events were observed. They are not. Every event passes through EDSS rating noise, a confirmation window and relapse attribution before it is counted. pirapower simulates that whole pipeline: sim cohorts with a known PIRA reduction, edssplus for confirmed worsening, pirma for attribution, and a log-rank test on time to first PIRA.
pip install mstrial
mstrial pirapower --n 250 500 1000 --effect 0.3 --years 2 --noise 0.15 --confirm-days 168 --reps 100
A 30 % true reduction, two years (results/pirapower/results/power.tsv, 60 simulated trials per cell; regenerated 2026-09-30)
| EDSS misrating | Confirmation | 250 per arm | 500 per arm | 1000 per arm |
|---|---|---|---|---|
| 15 % of visits | 24 weeks | 0.15 | 0.30 | 0.57 |
| 30 % of visits | 24 weeks | 0.22 | 0.22 | 0.62 |
| 30 % of visits | 12 weeks | 0.25 | 0.37 | 0.67 |
Even 1000 patients per arm reach only about 60 % of the conventional 80 % power. The ratio of first-PIRA event counts between arms is 0.72 to 0.76, against a true PIRA rate ratio of 0.70: events that are really rating noise or misattributed steps dilute the effect. Shorter confirmation adds noise events but adds real events faster, and gains power here. With 60 replicates per cell each power has a standard error of about 0.06, so neighbouring cells within about 0.1 of each other are not distinguishable.
The simulation model is simple and its parameters are in sim: PIRA 0.12 episodes per patient-year, EDSS every 3 months, and in the active arm a relapse and new-lesion rate ratio of 0.5 besides the PIRA effect (the default two-arm design). These numbers were regenerated after an independent review found that sim's noise levels had simulated different cohorts; the earlier table is superseded. Research software. MIT.
registry
formerly mstrials
Which endpoints do multiple sclerosis trials actually measure? registry asks ClinicalTrials.gov through its public API. It searches every registered MS study whose outcome measures mention an endpoint (PIRA, slowly expanding lesions, paramagnetic rim lesions, central vein sign, neurofilament light, GFAP, NEDA, EDSS-plus, SDMT, OCT, brain atrophy) and counts them by phase, status and start year. Every matched study is written out with its NCT number, so each count can be checked.
pip install mstrial
mstrial registry --out studies.tsv
Landscape on 2026-09-30 (results/registry/results/)
studies interventional phase 3 recruiting or not yet started 2023 or later
endpoint
SDMT / cognition 441 342 62 104 150
brain atrophy 236 201 77 34 39
neurofilament light 167 121 33 60 86
OCT retina 85 53 4 25 20
NEDA 63 35 16 14 23
GFAP 47 26 4 26 27
paramagnetic rim lesions 25 19 3 14 15
PIRA 23 12 8 12 16
EDSS-plus / composite 10 8 1 2 4
central vein sign 10 4 0 4 4
slowly expanding lesions 9 7 2 5 5
PIRA, the endpoint the progressive-MS field is converging on, appears in the outcomes of 23 registered MS studies, 8 of them phase 3. Slowly expanding lesions appear in 9, paramagnetic rim lesions in 25 and the central vein sign in 10. The tools that measure those endpoints (pirma, lesiontrack, mscard) matter for a few dozen trials now, and for many more soon.
Precision was checked by reading the outcome text of every hit for three endpoints. All 9 slowly expanding lesion hits and all 10 central vein sign hits contain the phrase; 22 of 25 paramagnetic rim lesion hits do (the other three mention rim lesions another way or not at all). The search terms are short quoted phrases ("slowly expanding", not "slowly expanding lesion", which the API matches exactly and which misses every "lesions"; unquoted terms match the words anywhere, so "slow-wave" plus "Expanded Disability" counted as a hit in an earlier version). The other counts are outcome-text matches, not a curated review. Research software. MIT.
Metadata
Release files for mstrial 0.1.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| mstrial-0.1.0.tar.gz | 22.4 kB | Without provenance | Details for mstrial-0.1.0.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| mstrial-0.1.0-py3-none-any.whl | Python 3 | none | any | Details for mstrial-0.1.0-py3-none-any.whl |
Total release size: 43.8 kB
Release files / mstrial-0.1.0.tar.gz
| Download URL | mstrial-0.1.0.tar.gz |
|---|---|
| Size | 22.4 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
e31bfd61e1970a21e9e4c19558a92b2d2f4c391b38fd62539a90de1412dd023f
|
|
BLAKE2b-256 checksum How to use checksums |
f90f3e5bb0d5505f9592c5bbee0fc01c498fa9525803689670bd97b65f4d0a89
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.12.3
|
Release files / mstrial-0.1.0-py3-none-any.whl
| Download URL | mstrial-0.1.0-py3-none-any.whl |
|---|---|
| Size | 21.4 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
e03ef7c7585fb297badfc6c312f0aef0350f9e4473580425be7ee6a48a2c7c33
|
|
BLAKE2b-256 checksum How to use checksums |
98b1f9e9a38a9d55c0e787caee69563b55525652e508465c9e333db8576e4caf
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
No |
| Uploaded via |
twine/7.0.0 CPython/3.12.3
|
Security for mstrial 0.1.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
No provenance found
None of the files in this release were uploaded with provenance metadata.
A note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.