Vendor-agnostic NMR import, processing, plotting, and a desktop GUI.

Every vendor importer reads raw acquisition data (not a vendor's own pre-processed output) and produces the same NMRSpectrum object, which the same processing and plotting code then operates on. Currently supported: Bruker (TopSpin fid/ser), X-Pulse (JCAMP-DX FID, including arrayed/PFG experiments), Varian/Agilent (fid/procpar), JEOL Delta (.jdf, 1D only so far).

Layout

  • opennmr.core — vendor-agnostic data model (NMRSpectrum, NMRAxis, NMRMetadata) and nucleus/gyromagnetic-ratio lookups.
  • opennmr.io — per-vendor readers, all producing NMRSpectrum.
  • opennmr.processing — FID processing (apodization, FFT, phasing), VOCS, spectrum arithmetic, 2D slice extraction, peak fitting, relaxation and diffusion fitting, PFG b-values and gradient calibration, DOSY by inverse Laplace transform, and multivariate component resolution (SCORE/OUTSCORE).
  • opennmr.plotting — matplotlib plotting, ax-first so it embeds cleanly in a GUI canvas as well as standalone notebook figures.
  • opennmr.gui — PySide6 desktop shell.

Install from PyPI

pip install opennmr
opennmr-gui

Python 3.12 or newer. The same package serves a notebook (from opennmr import notebook) and the GUI.

Updating

Settings ▸ Updates shows the installed version and checks PyPI when you press Check for Updates (a check at start-up is off unless you turn it on). When a newer version exists, Update to X and restart closes openNMR, upgrades it with pip in the same Python environment, and opens it again; nothing is shown while it runs. If the new version does not start, the old one is put back, and Settings ▸ Updates says so the next time. Details are kept in ~/.opennmr/update.log. Where pip may not change the environment (a system Python, say), the button is not offered and the command to run yourself is shown instead: pip install --upgrade opennmr.

Install (editable, into an existing environment)

pip install -e ".[test]"

Run the GUI

opennmr-gui

Add an OpenNMR button to TopSpin

opennmr-topspin-install

Finds the TopSpin installations on the local machine, offers to copy the OpenNMR plugin into each installation's exp/stan/nmr/py/user/ folder, and to add the opennmr launch command to TopSpin's autostart.mac. At the TopSpin command line, opennmr puts the button on the main toolbar and opennmr -kill takes it off again.

The plugin records the absolute path of the environment you run the installer from, rather than looking for opennmr-gui on PATH when the button is clicked. Depending on how TopSpin is launched, shell startup files may not be read, so a conda install is invisible to it, and on Windows neither conda nor python.org's installer puts itself on PATH by default. The cost is that moving or recreating the environment can break the button; re-run the installer if it does.

--topspin FOLDER defines a TopSpin installation directory the search missed; --uninstall removes the plugin and its autostart entry; --list shows what was found. Writing into TopSpin's own folder may need administrator rights.

Run tests

pytest

Getting good data for diffusion and relaxation analysis

The analysis methods in this package differ enormously in how much they ask of the data, and the demanding ones fail quietly: they return a confident-looking answer with an excellent fit statistic. This section is what each one actually needs. The GUI repeats the essentials in the relevant dialogs.

The single most important thing

Fit quality does not tell you whether a multivariate resolution is right. Measured directly on synthetic mixtures in this repository's own test suite: an OUTSCORE run whose diffusion coefficients were 69% wrong reported R² = 0.99940, against 0.99937 for the run that got them right. The error surface really is that flat — wildly different answers reproduce the data equally well. A good R² means "this many components can fit", never "these are the right components".

This is why processing.score reports cross-talk alongside R², warns when the two methods disagree while fitting equally well, and says in its own report which number the run actually optimised.

Acquisition

Peak-by-peak fit DOSY (ILT) SCORE / OUTSCORE
Gradient levels / delays 8+ 12+ 8–10 minimum, 15+ preferred
Attenuation of the fastest component to ~20% to ~5% to ~10%
Phase / baseline helps required required
Resolves overlapped peaks no no yes
  • Sample the decay, don't just start it. A component that loses only 20% of its intensity across the whole series is nearly a constant, and its decay constant is poorly determined no matter how good the fit looks. There is a test in tests/test_score.py pinning this down: a component attenuating by 8% is recovered only to within a factor, which is a property of the experiment and not of the algorithm. The fix is a longer diffusion time or stronger gradients.
  • Space the levels sensibly. Equal steps in b (equal steps in gradient squared) sample a decay far better than equal steps in gradient amplitude, which crowds points into the undecayed start.
  • Keep signal-to-noise up on the last levels too, not just the first. The most-attenuated points carry most of the information about the slow components.
  • Don't let peaks move. A bilinear model — the assumption behind SCORE, OUTSCORE and DOSY alike — says each component has one fixed spectrum. A peak that drifts across the series (temperature, exchange, referencing) breaks that, and shows up as a spurious extra component rather than as an error.

Processing, before any of these methods

  1. Phase properly, in absorption mode. Non-negativity is the single most stabilising constraint available to SCORE, OUTSCORE and the ILT, and it means nothing on a dispersive spectrum.
  2. Baseline-correct. A rolling baseline is not a non-negative superposition of component spectra; it will be absorbed into whichever component can best accommodate it.
  3. Reference consistently across the series.
  4. Use real b-values. The GUI refuses to run DOSY or SCORE when the x-axis has fallen back to plain slice indices, because the resulting "diffusion coefficients" would be in no physical unit while being labelled m²/s. Either read them from a Bruker diff.xml, or supply δ/Δ/gradient and let processing.diffusion.b_value compute them — and get the gradient shape factor right: treating a stock Bruker SMSQ10 sequence as a perfect rectangle overestimates b by 23%, which lands directly on D.

Where the x-values come from

The Curve Fitting sub-tab's Values source sets the x-axis for Fit Curve, DOSY and SCORE alike — one setting, so the three cannot end up fitting the same series against different axes. The line under it always shows what the current source resolves to, against the selected experiment.

Source What it reads
Auto this experiment's own vdlist/diff.xml, else slice index
Manual list values typed in, comma- or whitespace-separated (10m etc. accepted)
Start + step an evenly-spaced series, one value per slice
List file × factor any one-column text file of numbers, scaled by a constant or an acquisition parameter
Relative gradient an X-Pulse arrayed PFG series' own gradient fractions
b from gradients a true b-value computed from δ/Δ/G

List file × factor is the vendor-neutral one. opennmr.io.lists reads any one-column list — a Bruker vdlist/vclist/difflist, an X-Pulse parameters/…_valueslist.txt, your own delays.txt — and find_value_lists offers whatever is actually sitting with the data (the experiment folder, Bruker's lists/ tree, X-Pulse's parameters/, and the parent folder), with Browse… for anything else. Nothing is inferred from the filename: the Factor is what turns a loop counter or a relative fraction into a physical quantity.

The Factor accepts an expression in the experiment's own acquisition parameters, not only a number — the same names a custom fitting equation uses, from opennmr.core.acquisition.acquisition_constants (TAU, P90, D70 for X-Pulse; d1, p1, cnst2, l4 for Bruker). So an X-Pulse CPMG echo-count list becomes a T2 delay series with a factor of TAU*2, with no arithmetic done by hand. The panel shows what the expression resolved to and which parameters went into it. Parameters are used exactly as the vendor recorded them — an X-Pulse TAU is in µs and stays in µs, so any conversion belongs in the expression; only the person reading the pulse programme knows the unit it was written in.

Everything in the panel is per experiment. Selecting a different spectrum re-scans its folder for list files and restores its own factor, unit and source — nothing is carried over from the one before.

Unit. The Unit combo says what the numbers in this panel are, not only how they are displayed — a typed list of 10, 20, 40 and a list file holding 10, 20, 40 both mean 10, 20, 40 of that unit. It defaults to ms; fits are always done in seconds. For a list file it applies to the whole product, list × Factor, which makes the X-Pulse CPMG case simpler rather than harder: with the Unit on µs an echo-count list takes a factor of plain TAU*2, since TAU is already recorded in µs.

Two things are never rescaled by it, because they already carry a unit of their own: a value that names one (10m is 10 ms whatever the combo says — a vdlist written that way is taken at its word) and the Auto source, which is the vendor's own values in the vendor's own unit. A diffusion fit has no Unit row at all: a b-value has no comparable prefix convention.

The unit reaches the whole panel, not just the conversion: the Fit tab's x-axis and label, the guess table's time rows (in both directions — a T2 guess typed as 50 under a ms heading reaches the model as 0.05 s), "adopt fit as guess", the bounds error messages, and the CSV export. Only time parameters scale — relaxation._TIME_PARAMS, the same set that decides which reported values get a time unit printed after them — so an amplitude, a stretch exponent and a diffusion coefficient are left alone. The stored fit is never modified; the unit is a display transform, so changing it redraws rather than refits.

Fitted values in the report keep format_time_value's automatic ms/µs/ns scaling rather than being forced to the chosen unit: it is never wrong, and pinning it would print a 2 s result as "2000 ms".

Slices. The Curve Fitting panel's Slices box limits the analysis to the first N slices of a series ("all" by default). One setting feeds Fit Spectrum, Fit Curve, DOSY and SCORE, so they cannot disagree about how much of a series is in use; DOSY and SCORE cut the data matrix with it, not only the x-values.

A value list longer than the data is not an error — the surplus is simply unused, the way TopSpin uses the first F1-TD entries of a longer vdlist. A shorter one cannot be fitted, and says so with the slice count to set. Pseudo-2D row counts are capped at acqu2s's own TD (the status parameter file): the floor-division fallback in _guess_raw_2d_shape only exists to find a reshapable shape, and rows past TD are not acquired data.

Relative amplitudes. Any model with more than one amplitude reports each one as a fraction of the total — on the parameter's own row and again in a section pairing it with the rate it belongs to (relaxation.amplitude_fractions). That is the form a multi-component result is quoted and compared in; a raw A1 = 0.0532 is on whatever arbitrary intensity scale the spectra were processed on and says nothing on its own. The compact per-peak summary and the global fit's per-curve block quote amplitudes only as shares, since comparing curves is the whole reason those blocks exist.

Amplitudes are recognised by name — M0, A/A1/A2, I0/I0a/ I0b, I1…In — the same way _TIME_PARAMS decides what gets a time unit. A custom equation gets no ratios: its parameters are whatever you named them, and treating the wrong symbol as an amplitude would be worse than showing nothing. A share outside 0–100% (components of opposite sign, usually an over-parameterised model) is flagged rather than hidden.

Export curve fit (CSV) writes the data behind the plot — the x-axis in the displayed unit, then every peak's measured integral or amplitude at each point with the fitted curve beside it (processing.relaxation.curve_fit_to_csv). Peaks are not assumed to share an x-axis: a point excluded from one peak's fit leaves an empty cell rather than a number that was never measured.

SCORE fits the same model Fit Curve does

SCORE's per-component decay is not a private exponential: it is whichever processing.relaxation.RELAXATION_MODELS entry the Model combo names, evaluated through processing.score.build_kernel. So a stretched or inversion-recovery model resolves components with a β or an inversion efficiency of their own, and a Stejskal-Tanner fit and a SCORE resolution of the same series are the same function asked two different questions.

The model's amplitude parameter is pinned at 1 rather than fitted — each component's size lives entirely in its resolved spectrum, which is solved for linearly, and fitting both would be exactly redundant. Which parameter that is gets measured (doubling it doubles the curve), not matched against a list of names, so a custom equation works too. A model that already describes several populations (a biexponential) has no such parameter and is refused with that reason: SCORE's own component count is doing that job. 5. Calibrate the gradient if you don't know it. A maximum gradient 10% wrong makes every D 21% wrong, with nothing in the fit to show for it. Analysis ▸ Calibrate Gradient… measures it from a standard of known D. 6. Check the gradient axis. A probe's maximum gradient is saved per axis, because the three coils of a triple-axis probe are rarely the same strength — one number shared between them quietly rescales every D measured on the other two. Set the axis alongside the maximum; "Save gradient for probe" then stores that axis's value and leaves the others alone. It is the same setting the Imaging tab shows, and the same number: one experiment, one coil, one maximum.

Reference deconvolution (processing.refdeconv)

Not wired into the GUI, and not usable on a processed spectrum. It inverse-transforms the spectrum back to its FID, so the input must be the transform of a causal FID. A TopSpin 2rr/2ii is not — it carries the digital-filter group delay and has apodisation and baseline correction folded in. Applied to one, it destroys the line (measured: a peak of 2397 spanning 0.0159 ppm became 16 spanning 0.536 ppm). It needs the raw FID path; that wiring does not exist yet.

Corrects a lineshape distortion that every peak shares — a bad shim, a non-spinning sample, or the electrodes in an eNMR cell. Pick an isolated resonance, assert the shape it should have had, and the ratio of ideal to measured is the distortion; divide it out and every peak is corrected at once.

from opennmr.processing import refdeconv
result = refdeconv.reference_deconvolve(
    spectrum_row, ppm, region=(-0.2, 0.2), fwhm=0.01)   # target width, ppm

Validated against a constructed truth (build an FID, distort it, transform): a pure phase distortion broadening a line from 0.147 to 0.244 ppm is corrected back to 0.159, and peaks outside the reference region are corrected too — the method's whole claim. Recovery degrades as the distortion destroys more of the FID (0.031 s of surviving signal recovers only 0.574 → 0.366); that limit is information, not implementation.

REGULARISATIONS is the method, not a detail — the reference FID decays into noise and an undamped reciprocal diverges. wiener (default) rolls off smoothly; truncate is sharper but rings; none exists to demonstrate the failure.

It does not fix convection or electro-osmotic flow (per-scan phase modulation, not one fixed envelope), needs a genuinely isolated reference, and gives you whatever linewidth you ask for — asking for one the acquisition cannot support amplifies noise until the fit looks sharp and means nothing.

eNMR (processing.enmr, and the Analysis ▸ eNMR tab)

The phase a resonance picks up under an applied field is linear in the voltage: Δφ = γ·g·δ·Δ·μ·V/d.

The slope is the result — it is what the data determines, in rad/V, and needs nothing but the data. Converting it to a mobility needs the cell's electrode gap and the sequence's gradient and timings, which live in a lab notebook rather than any vendor file, so that step is optional:

from opennmr.processing import enmr
phases = enmr.phase_series(rows, ppm, region=(3.18, 3.42))

enmr.fit_enmr(voltages, phases)                      # slope alone
enmr.fit_enmr(voltages, phases, electrode_gap=0.0385,
               gamma=2 * np.pi * 42.577e6, gradient=0.3,
               delta=1e-3, big_delta=0.1)            # ... and a mobility

Two levels of pairing, and they are different things.

Within one experiment, each voltage is acquired at both polarities. Reversing the field reverses the drift, so (φ₊ − φ₋)/2 doubles the signal and cancels every phase error that is not field-driven. polarity_pairs detects this rather than assuming it.

Across experiments, the whole run is repeated with the gradient reversed, which flips the sign of the fitted slope. combine_experiments aligns the signs and averages — a plain average would cancel the measurement away — and reports the spread, because two runs of one sample agreeing is the evidence that either measured anything. On a real reversed pair: +1.244e-2 and −1.396e-2 → +1.320e-2 ± 1.5e-3 rad/V, spread 8%.

Unwrap with phase_ramp, not phase_series. Consecutive points of a +V/−V series are opposite polarity and legitimately far apart, so unwrapping across them makes np.unwrap read a polarity jump as a wrap and insert a 2π step that was never there. On real data that turned a clean ramp (R² 0.88) into no correlation at all (R² 0.009) — it does not look like a broken calculation, it looks like a negative result. phase_ramp takes the voltages and picks the stride itself.

Validated against an accepted literature value, the only check that catches a wrong 2π, a wrong drift time or a unit slip, all of which still produce a beautiful straight line. On a TMABr standard (test_data/eNMR/...2024-05-13/21):

species slope R² μ
TMA⁺ 7.90e-3 ± 2.2e-4 rad/V 0.9954 3.79e-8 m²/Vs (lit. 3.79e-8)
water 3.3e-5 ± 8.8e-5 rad/V 0.023 zero to within error

Water sits in the same tube, field and shim, so it controls for everything except charge.

Phase comes from the complex integral over the peak region, which on this data gives R² = 0.995 with no lineshape fit at all; a full complex fit is for overlapped peaks, not for phase accuracy as such.

The PFG constants read themselves. pfg_params(spectrum) — or fit_enmr(..., spectrum=spectrum) — fills in γ, g, δ and Δ, so only the electrode gap needs typing. Which source each comes from was measured across five real datasets, because the pulse programme's legend is not enough: Δ = d20 reproduces diff.xml exactly, but δ does not (d17+d18 is 67–83% out on four of five), and the gradient in T/m needs the probe calibration that only diff.xml/diffConf.xml carries. So diff.xml is the source of record, d20 the cross-check, and each value reports its provenance. γ is converted to rad/s/T once, on the way out.

electrode_gap has no default, and a half-supplied set of constants is rejected rather than silently skipped: μ scales directly with the gap, no vendor file records it, and a plausible-looking default would quietly rescale every result.

Choosing a method

  • One clean, well-separated peak per species → ordinary curve fitting (Analysis ▸ Curve Fitting). It is the only one of these that gives a diffusion coefficient with a meaningful uncertainty.
  • Peaks belonging to the same molecule → tick Fit all peaks together and share D. Fitting separately and averaging understates the uncertainty.
  • Overlapped peaks, species differing ≳30% in D → SCORE.
  • Overlapped peaks, species differing by only a few percent in D → OUTSCORE, which minimises cross-talk rather than residual. It separates down to ~3% where SCORE needs ~30% — but it assumes the components have genuinely different peaks. For species that legitimately share most of their resonances, minimising overlap pushes toward something untrue; the report warns when that has happened.
  • Unknown number of components, or a continuous distribution → the DOSY map (Analysis ▸ DOSY Map (ILT)). Treat peak positions as the result and peak widths as an artefact of the regularisation.

Both SCORE/OUTSCORE and the curve fits take the number of components as an input, not an output. Run at one more and one fewer and prefer the answer whose component spectra look like plausible, separate molecules.

Metadata

Release files for opennmr 0.3.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for opennmr 0.3.0
File Size Uploaded Provenance
opennmr-0.3.0.tar.gz 3.4 MB Without provenance Details

Built distribution (wheel)

Table of built distributions (wheels) for opennmr 0.3.0
File Interpreter ABI Platform
opennmr-0.3.0-py3-none-any.whl Python 3 none any Details

Total release size: 6.1 MB

Release files / opennmr-0.3.0.tar.gz

Download URL opennmr-0.3.0.tar.gz
Size 3.4 MB
Tags Source
SHA-256 checksum
How to use checksums
aeba16f3b4acd03e1374ee863f646b3e5492d5636e3014da44563788a19e37d8
BLAKE2b-256 checksum
How to use checksums
86e361630840b060334b2c075d86f9d1296e20fe6de63923aa2488bf4f629a4f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.14.7

Release files / opennmr-0.3.0-py3-none-any.whl

Download URL opennmr-0.3.0-py3-none-any.whl
Size 2.7 MB
Tags Python 3
SHA-256 checksum
How to use checksums
839ac6f13c3d358eb44a10c93f2f78d216c4e755e14c46f2e8e83469f4881a1d
BLAKE2b-256 checksum
How to use checksums
43fdef64294420b874dd42521fb65c27325449837dc0b86220a9bc6986c2038e
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.14.7

Security for opennmr 0.3.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page