OT-AIops

Governed, vendor-neutral industrial data tap + intelligent troubleshooting for AI agents — across OPC-UA (incl. Historical Access), Modbus-TCP, S7comm, Mitsubishi MC, MTConnect, MQTT/Sparkplug B (full decode), EtherNet/IP (Rockwell/Allen-Bradley Logix), and EtherCAT (pysoem/SOEM fieldbus master) — plus OEE/downtime, active asset-inventory, and change-of-value analytics.

OT-AIops is the OT/industrial member of AIops-tools. It is a factory-level, vendor-neutral, governed data tap that lets an AI agent safely read industrial control systems across many field protocols, plus a cross-protocol intelligence layer that localizes "no data" breaks, analyzes alarm floods (ISA-18.2), ranks unhealthy tags, computes OEE / categorizes downtime, and builds an active asset register. Read-first by design; the few write/command paths are OT-dangerous and gated by MOC discipline. Every tool runs through a vendored governance harness (audit / budget / risk-tier / undo).

⚠️ Preview / v0.3.0 — validated against an in-process OPC-UA simulator (incl. HDA), mocked Modbus/S7/Mitsubishi/EtherNet-IP(pycomm3)/EtherCAT(pysoem) clients, static MTConnect XML fixtures, and synthetic MQTT/Sparkplug B protobuf payloads. NOT tested against live PLCs / SCADA / brokers / Logix controllers / EtherCAT slaves. EtherCAT is hard-real-time and has no software simulator (Linux + root + a real bus only), so it is entirely unverified against hardware. See Safety.

Why

OT is exactly where you want an agent on a tight leash: read first, never blind-write. OT-AIops is the safe, neutral read wedge — one package, one MCP server, many protocols — with governance and an intelligence layer that turns raw reads into actionable diagnoses.


Consolidated capability matrix

Protocol Tool Operation R/W risk_tier Returns (key fields)
OPC-UA opcua_server_info server status R low state, product_name, namespaces
OPC-UA opcua_browse browse node tree R low [{node_id, browse_name, depth}]
OPC-UA opcua_read_node read one node R low value, datatype, source_timestamp, good
OPC-UA opcua_read_many batch read R low [{node_id, value, ...}]
OPC-UA opcua_subscribe_sample bounded sample R low {collected, samples[]}
OPC-UA opcua_read_alarms alarm surfacing R low {active_alarms[], active_count}
OPC-UA opcua_read_history Historical Access (HDA) R low {supported, count, values[]}
OPC-UA health_summary threshold classify R low {overall, counts, offenders[]}
OPC-UA anomaly_scan stddev outliers R low {mean, stddev, outliers[]}
Modbus modbus_read_holding FC03 R low {raw_registers, decoded[]}
Modbus modbus_read_input FC04 R low {raw_registers, decoded[]}
Modbus modbus_read_coils FC01 R low {bits[]}
Modbus modbus_read_discrete FC02 R low {bits[]}
Modbus modbus_health_summary threshold classify R low {overall, counts, offenders[]}
S7comm s7_cpu_info CPU id + run/stop R low {cpu_status, cpu_info}
S7comm s7_read_area read DB/M/I/Q R low {items:[{address, value}]}
S7comm s7_read_db read data block R low {items:[{address, value}]}
S7comm s7_read_many batch addresses R low {items:[{address, value}]}
S7comm s7_write_db write data block W high/MOC {before, written, _undo_id}
Mitsubishi MC mc_cpu_status CPU type R low {cpu_type, cpu_code}
Mitsubishi MC mc_read_words word devices R low {words[]}
Mitsubishi MC mc_read_bits bit devices R low {bits[]}
Mitsubishi MC mc_read_many random read R low {words[], dwords[]}
Mitsubishi MC mc_write_words write words W high/MOC {before, written, _undo_id}
MTConnect mtconnect_probe device model R low {devices:[{components:[{data_items}]}]}
MTConnect mtconnect_current latest values R low {observations[]}
MTConnect mtconnect_sample bounded stream R low {observations[]}
MTConnect mtconnect_assets assets R low {assets[]}
MTConnect mtconnect_oee_snapshot OEE inputs R low {availability, execution, verdict}
MQTT/Sparkplug mqtt_read_topic bounded read R low {messages:[{topic, payload}]}
MQTT/Sparkplug sparkplug_subscribe_sample bounded SpB sample (full decode) R low {samples:[{sparkplug, payload:{metrics[]}}], seq_gap_count}
MQTT/Sparkplug sparkplug_decode_payload decode raw SpB payload R low {metrics:[{name, alias, datatype, value, is_historical}]}
MQTT/Sparkplug sparkplug_node_list node discovery + state R low {nodes:[{group_id, edge_node_id, online, devices}], primary_hosts[]}
MQTT/Sparkplug uns_browse topic-tree browse R low {topics[], tree{}}
MQTT/Sparkplug mqtt_publish publish/command W high/MOC {published_bytes, applied}
EtherNet/IP eip_controller_info Logix controller id R low {controller:{vendor, product_name, revision, serial}}
EtherNet/IP eip_list_tags tag discovery R low {tag_count, tags:[{name, data_type, structure}]}
EtherNet/IP eip_read_tag read one tag/array R low {tag, value, type, good}
EtherNet/IP eip_read_many batch read R low {items:[{tag, value, type}]}
EtherNet/IP eip_write_tag write tag W high/MOC {before, written, _undo_id}
Diagnostics diagnose_dataflow localize no-data R low {verdict, diagnosis, hops[]}
Diagnostics alarm_bad_actors ISA-18.2 flood R low {flood_verdict, top_offenders[]}
Diagnostics tag_health offender ranking R low {overall, offenders[]}
Diagnostics historian_health gap/flatline R low {verdict, gaps[]}
Analytics oee_compute OEE = A×P×Q R low {availability, performance, quality, oee, oee_pct}
Analytics downtime_events stoppage detect + categorize R low {event_count, total_downtime_s, by_category, events[]}
Analytics oee_multidim OEE machine×part×shift R low {matrix[], worst_performers[], mean_oee}
Analytics asset_inventory active fingerprint R low {assets:[{protocol, vendor, model, firmware, reachable}]}
Analytics monitor_changes bounded change-of-value R low {change_count, changes:[{value, previous, wall_clock}]}
EtherCAT ethercat_master_state master/WKC + slave count R low {master_state, expected_working_counter, slaves_found, slaves_expected}
EtherCAT ethercat_slaves bus scan R low {slave_count, slaves:[{index, name, vendor_id, product_code, state}]}
EtherCAT ethercat_slave_info slave detail R low {sync_managers[], fmmus[], object_dictionary[], input_bytes}
EtherCAT ethercat_read_sdo CoE SDO upload R low {index, byte_length, hex, as_uint}
EtherCAT ethercat_read_pdo input PDO snapshot R low {working_counter, input_hex, input_byte_length}
EtherCAT ethercat_write_sdo CoE SDO download W high/MOC {before, written, applied}
EtherCAT ethercat_set_state AL-state transition W high/MOC {before, requested, reached, applied}
Self protocols_supported capability map R low {protocols[], diagnostics[], analytics[]}

57 tools = 51 read + 6 write (MOC). The 51 reads = 41 protocol-read · 4 diagnostics · 5 analytics · 1 self. Run protocols_supported() (or ot-aiops protocols) for the live map.


Per-protocol reference

OPC-UA

  • Versions/variants: binary opc.tcp:// via asyncua (sync facade). Security: anonymous + username/password. Certificate message security (Sign / SignAndEncrypt) = roadmap, not validated.
  • Connection params: endpoint_url, username (password encrypted), security_mode, security_policy.
  • Not supported / planned: cert security; real Alarms & Conditions event subscriptions (alarms are surfaced best-effort by browsing alarm-like boolean nodes).

Modbus-TCP

  • Versions/variants: Modbus-TCP via pymodbus. Read function codes FC01 (coils), FC02 (discrete), FC03 (holding), FC04 (input). Write FCs (FC05/06/15/16) = not implemented (read-only preview).
  • Connection params: host, port (502), unit_id. Registers are untyped 16-bit words → decode hint (uint16/int16/uint32/int32/float32/raw); big-endian word order.
  • Coverage: many domestic 国产 PLCs (汇川 Inovance / 信捷 Xinje / 和利时 Hollysys / 台达 Delta) and any Modbus-TCP vendor.

S7comm (Siemens + 仿西门子 国产)

  • Versions/variants: pyS7 (pure-Python, ISO-on-TCP / RFC1006 — no native libsnap7). S7-300/400/1200/1500 and compatible clones. Memory areas DB / M (merker) / I / Q. No protocol auth (CPU gates via "Permit access with PUT/GET").
  • Connection params: host, port (102), rack, slot (0/1 for 1200/1500; 0/2 common for 300/400).
  • Write: s7_write_db = high risk_tier, MOC, dry-run default, captures BEFORE value + undo.
  • Not supported / planned: optimized/symbolic DB access on 1500 with "optimized block access" can require absolute-addressing config on the CPU.

Mitsubishi MC

  • Versions/variants: pymcprotocolMC 3E frame (binary) only. 1E / 4E frames = not supported. PLC types Q / L / QnA / iQ-R / iQ-L. Devices: D/W/R (word), M/X/Y/B (bit).
  • Connection params: host, port (5007 default; set to the module's open MC port), plctype.
  • Write: mc_write_words = high/MOC/dry-run default, captures BEFORE + undo.

MTConnect (ALL CNC machine tools)

  • Versions/variants: agent REST + XML (requests + xml.etree), namespace-agnostic (parses MTConnect 1.x Devices/Streams/Assets schemas). Endpoints: /probe, /current, /sample, /assets. Read-only by specification. XML parsing is hardened (DTD/entity declarations rejected — XXE/billion-laughs defense).
  • Connection params: agent_url (e.g. http://host:5000).
  • Not supported / planned: MTConnect streaming (long-poll interval=); only bounded count= samples.

MQTT / Sparkplug B / UNS

  • Versions/variants: paho-mqttMQTT 3.1.1 & 5. Sparkplug B topic convention spBv1.0/{group}/{type}/{edge}/[device] (NBIRTH/DBIRTH/NDATA/DDATA/NDEATH/DDEATH/STATE). TLS + username/password supported.
  • Full Sparkplug B decode (no optional extra): payloads are protobuf-decoded with a vendored, byte-for-byte copy of the official Eclipse Tahu sparkplug_b.proto generated module (depends only on protobuf). Per metric you get name, alias (resolved to its name via the BIRTH model), datatype (Int8…Int64/UInt…/Float/Double/Boolean/String/DateTime/Text/UUID/DataSet/Bytes/File/Template/PropertySet…), value, timestamp, and the is_historical / is_null flags. A birth/death + seq model tracks node/device online state (NBIRTH/DBIRTH ↔ NDEATH/DDEATH), builds the alias→name map from BIRTH, applies NDATA/DDATA by alias, and flags seq gaps / out-of-order. Primary-host awareness: STATE/<host_id> topics surface in sparkplug_node_list. sparkplug_decode_payload decodes a single raw payload (base64/hex) offline.
  • Connection params: host/broker, port (1883 / 8883 TLS), topic, use_tls, username (password encrypted).
  • Command: mqtt_publish = high/MOC/dry-run default; a published command has no automatic inverse.

EtherNet/IP (Rockwell / Allen-Bradley)

  • Supported: ControlLogix / CompactLogix (and GuardLogix) via CIP / EtherNet-IP using pycomm3 (pure-Python — no native deps). Tag-based, symbolic access: read/write tags by name (Conveyor.Speed, Array[3], Program:Main.X) and discover the controller's tag list at runtime (eip_list_tags, the headline feature). eip_controller_info reads the controller identity.
  • Connection params: host, slot (0 for CompactLogix; the CPU slot for a ControlLogix chassis), port (44818). protocol: ethernetip (alias eip).
  • Write: eip_write_tag = high risk_tier, MOC, dry-run default, captures BEFORE value + undo.
  • Not supported / planned: PLC-5 / SLC-500 (PCCC) and Micro800 are not supported = roadmap (Logix tag model only).

EtherCAT (pysoem / SOEM fieldbus master)

  • Supported: a real EtherCAT master via pysoem (the Python binding for the SOEM C stack). CoE SDO read (ethercat_read_sdo, acyclic mailbox upload) + SDO write (ethercat_write_sdo, download), input PDO read (ethercat_read_pdo, one bounded cyclic snapshot), bus scan / slave enumeration (ethercat_slaves, ethercat_slave_info — identity, SM/FMMU mapping, object-dictionary summary), master/working-counter state (ethercat_master_state), and AL-state transitions INIT↔PREOP↔SAFEOP↔OP (ethercat_set_state).

  • HARD REQUIREMENTS (no way around them): Linux, root or CAP_NET_RAW, a dedicated NIC cabled to the bus, and real EtherCAT slave hardware. pysoem is an OPTIONAL extra: pip install ot-aiops[ethercat] — the base package installs and imports without it, and every EtherCAT tool then degrades to a teaching error (never crashes, never imports pysoem at module load).

  • NOT supported: no software simulator exists (unlike OPC-UA / Modbus) — EtherCAT is hardware-only and not testable in mock-only CI; macOS is unsupported. EoE / FoE / SoE mailbox protocols and full PDO-mapping decode/expansion = roadmap.

  • Connection params: nic (the dedicated interface name, e.g. eth1; alias interface), optional expected_slaves (a sanity check vs the bus scan). protocol: ethercat.

  • Operations matrix:

    Tool Op R/W risk Capture/notes
    ethercat_master_state master + WKC state, slave count R low expected vs found
    ethercat_slaves bus scan / enumerate R low index/vendor/product/rev/addr/AL-state
    ethercat_slave_info one-slave detail R low SM/FMMU + OD summary
    ethercat_read_sdo CoE SDO upload R low hex + uint interpretation
    ethercat_read_pdo input PDO snapshot R low single cycle, never loops
    ethercat_write_sdo CoE SDO download W high/MOC before-value (SDO read-back) + undo
    ethercat_set_state AL-state transition W high/MOC before-state + undo; can start/stop motion
  • Write/state safety: ethercat_write_sdo (hex little-endian bytes) and ethercat_set_state are high risk_tier, MOC, dry-run by default, capture the BEFORE value/state for undo, and need a CLI double-confirm. Changing EtherCAT state can START or STOP machine motion — treat with extreme care. 未经授权勿对生产控制系统写入.

OEE / downtime analytics (cross-protocol, read-only)

  • oee_computeOEE = Availability × Performance × Quality from production inputs (planned time, run time, ideal cycle, total/good counts). Each factor is reported raw + clamped to [0,1]; a capped performance >1.0 flags an optimistic ideal cycle.
  • downtime_events — auto-detects running→stopped transitions in a {timestamp, state} series and produces stoppage events with durations, categorized (changeover / material / mechanical / quality / break / unknown, by keyword heuristics or a {state: category} override).
  • oee_multidim — aggregates OEE across machine × part × shift (or any dimensions) from labelled records → the matrix + worst performers.
  • Operate over provided/collected inputs (fully testable without a plant). mtconnect_oee_snapshot surfaces the live MTConnect availability/execution inputs that feed these.

Active asset inventory / fingerprint (read-only)

  • asset_inventory — for each configured (or named) endpoint, actively connects with our own protocol client and reads its identity call (S7 s7_cpu_info, EtherNet/IP eip_controller_info, OPC-UA server build info, Modbus Device Identification FC43/0x2B, Mitsubishi CPU type, MTConnect device model), aggregating vendor / model / firmware / serial / reachable / last_seen into an asset register.
  • Honest scope (IEC 62443-flavored): this is ACTIVE fingerprinting via our client connections, NOT passive SPAN/tap discovery — it only finds devices we are configured to reach and adds light load to each. Passive, traffic-mirroring discovery is roadmap.

OPC-UA Historical Access (HDA)

  • opcua_read_history — reads stored historical values for a node over a [start,end] ISO-8601 window via the server's HistoryRead service (asyncua read_raw_history), bounded by max_points (≤2000). Returns {supported:false, note} gracefully when the server does not historize the node (no crash). Read-only.

Change-of-value (CoV) monitor

  • monitor_changes — bounded deadband report: polls a point and returns only the value CHANGES (with timestamps), not every sample. Works over OPC-UA / Modbus / S7 / Mitsubishi MC / EtherNet-IP. Never an infinite loop — hard-capped by both duration_s (≤120) and max_changes (≤500). Read-only.

Install

uv tool install ot-aiops      # or: pip install ot-aiops
ot-aiops init                 # interactive: add endpoints, store passwords encrypted
ot-aiops doctor               # config + per-protocol connectivity probe (point at simulators)
ot-aiops protocols            # the capability map

Master password

Secrets (per-endpoint passwords, MQTT credentials) are never stored in plaintext — they live in ~/.ot-aiops/secrets.enc (Fernet + scrypt). Export OT_AIOPS_MASTER_PASSWORD so the MCP server/CLI can unlock non-interactively:

export OT_AIOPS_MASTER_PASSWORD='…'

Example ~/.ot-aiops/config.yaml (one block per protocol)

endpoints:
  - name: line1
    protocol: opcua
    endpoint_url: opc.tcp://plc.lan:4840
    # username: operator           # password stored encrypted via init/secret set
    tags:
      - { ref: "ns=2;i=5", label: temp, warn_high: 70, alarm_high: 90 }
  - name: plc2
    protocol: modbus
    host: 10.0.0.5
    port: 502
    unit_id: 1
  - name: press1
    protocol: s7
    host: 10.0.0.6
    rack: 0
    slot: 1                        # S7-1200/1500
  - name: cell3
    protocol: mc
    host: 10.0.0.7
    port: 5007
    plctype: iQ-R
  - name: vmc1
    protocol: mtconnect
    agent_url: http://10.0.0.8:5000
  - name: uns
    protocol: mqtt
    host: broker.lan
    use_tls: true                  # → port 8883
    topic: spBv1.0/#
    # username: edge1              # password stored encrypted
  - name: cell5
    protocol: ethernetip           # alias: eip
    host: 10.0.0.9
    slot: 0                        # 0 for CompactLogix; CPU slot for ControlLogix
  - name: bus1
    protocol: ethercat             # Linux + root/CAP_NET_RAW + pip install ot-aiops[ethercat]
    nic: eth1                      # dedicated NIC cabled to the EtherCAT bus
    expected_slaves: 8             # optional sanity check vs the bus scan

ot-aiops init walkthrough (per protocol)

$ ot-aiops init
Step 1 — master password: ********
Step 2 — add an endpoint
  Endpoint name (e.g. line1): press1
  Protocol ('opcua','modbus','s7','mc','mtconnect','mqtt') [opcua]: s7
  S7 PLC host (IP/FQDN): 10.0.0.6
  Port [102]: 102
  Rack (0 for S7-1200/1500) [0]: 0
  Slot (1 for S7-1200/1500, 2 for S7-300/400) [1]: 1
✓ Saved endpoint 'press1'.

(MQTT prompts add TLS/topic/username; MTConnect prompts for agent_url; EtherCAT prompts for the nic + expected_slaves and warns about the Linux/root/NIC/optional-extra requirement; OPC-UA/MQTT prompt for a hidden password stored encrypted.)

Test against a simulator (per protocol)

  • OPC-UA — an asyncua demo server (the test suite runs a real in-process one).
  • Modbus — ModbusPal or a pymodbus server simulator.
  • S7 — a pyS7/snap7 S7 server sim (Snap7 server) on :102.
  • MTConnect — the public MTConnect demo agent, or a local agent.
  • MQTT — a local mosquitto broker (+ a Sparkplug edge for SpB topics).
  • Mitsubishi MC — GX Simulator / an MC 3E server sim.
  • EtherNet/IP — a pycomm3-compatible CIP/Logix simulator (or a spare CompactLogix).
  • EtherCATno simulator exists (hard-real-time, raw-Ethernet). Validate only on Linux, as root / with CAP_NET_RAW, on a dedicated NIC wired to real slaves (e.g. a Beckhoff EK1100 coupler + EL terminals). ot-aiops doctor reports a clear "needs Linux/root/NIC/pysoem" status off the bus rather than failing.

Usage

CLI (read)

ot-aiops opcua read "ns=2;i=5" -e line1
ot-aiops modbus holding 0 -e plc2 --count 4 --decode float32
ot-aiops s7 read-db 1 REAL 4 -e press1 --count 2
ot-aiops mc words D100 -e cell3 --count 8
ot-aiops mtconnect oee -e vmc1
ot-aiops mqtt nodes -e uns --timeout-s 15
ot-aiops eip tags -e cell5                           # Logix tag discovery
ot-aiops eip read "Conveyor.Speed" -e cell5
ot-aiops ethercat slaves -e bus1                     # EtherCAT bus scan (Linux+root)
ot-aiops ethercat read-sdo 0 4120 --subindex 1 -e bus1   # CoE SDO 0x1018:1
ot-aiops opcua history "ns=2;i=5" -e line1 --start 2026-06-28T08:00:00Z   # HDA
ot-aiops opcua monitor "ns=2;i=5" -e line1 --duration-s 20 --deadband 0.5 # CoV
ot-aiops diag dataflow -e line1 --ref "ns=2;i=5" --freshness-s 30
ot-aiops analytics oee 28800 25200 2.0 12000 11800   # OEE = A×P×Q
ot-aiops analytics asset -e press1 -e cell5           # active asset register

CLI (write — dry-run by default, double-confirm on --apply)

ot-aiops s7 write-db 1 INT 0 42 -e press1            # dry-run preview
ot-aiops s7 write-db 1 INT 0 42 -e press1 --apply    # double-confirm prompt
ot-aiops mqtt publish factory/line1/cmd '{"setpoint":50}' -e uns --apply
ot-aiops eip write-tag Setpoint 42 -e cell5 --apply  # Logix tag write (double-confirm)
ot-aiops ethercat write-sdo 0 24698 e8030000 -e bus1 --apply   # CoE SDO 0x607A download
ot-aiops ethercat set-state PREOP --slave 0 -e bus1 --apply     # AL-state (can stop motion!)

MCP tool calls (JSON args → sample structured return)

s7_read_db:

{ "db": 1, "dtype": "REAL", "start": 4, "endpoint": "press1", "count": 2 }
{ "endpoint": "press1", "area": "DB", "db": 1, "dtype": "REAL", "start": 4,
  "count": 2, "items": [ {"address": "DB1,REAL4", "value": 20.5},
                         {"address": "DB1,REAL8", "value": 4.2} ] }

s7_write_db (dry-run):

{ "db": 1, "dtype": "INT", "start": 0, "value": 42, "endpoint": "press1" }
{ "address": "DB1,INT0", "dry_run": true, "before": 7, "would_write": 42,
  "note": "Dry run — nothing written. Re-run with dry_run=false AND a recorded approver…" }

mtconnect_oee_snapshot:

{ "availability": "AVAILABLE", "execution": "ACTIVE", "controller_mode": "AUTOMATIC",
  "program": "O1234", "available": true, "running": true, "verdict": "running" }

eip_read_tag:

{ "tag": "Conveyor.Speed", "endpoint": "cell5" }
{ "endpoint": "cell5", "tag": "Conveyor.Speed", "value": 1500.0, "type": "REAL",
  "error": "", "good": true }

eip_write_tag (dry-run):

{ "tag": "Setpoint", "value": 42, "endpoint": "cell5" }
{ "endpoint": "cell5", "tag": "Setpoint", "dry_run": true, "before": 7,
  "would_write": 42, "note": "Dry run — nothing written. Re-run with dry_run=false AND a recorded approver…" }

ethercat_read_sdo (CoE SDO upload):

{ "slave": 0, "index": 4120, "subindex": 1, "endpoint": "bus1" }
{ "endpoint": "bus1", "slave": 0, "index": "0x1018", "subindex": 1,
  "byte_length": 4, "hex": "9a020000", "as_uint": 666 }

ethercat_set_state (dry-run; can start/stop motion):

{ "state": "OP", "slave": 0, "endpoint": "bus1" }
{ "endpoint": "bus1", "scope": "slave[0]", "dry_run": true, "before": "SAFEOP",
  "would_request": "OP", "note": "Dry run — no state change. … Changing EtherCAT state can start/stop machine motion." }

sparkplug_decode_payload (full SpB metric decode):

{ "payload": "CAESBwoDYWJjEAE=", "encoding": "base64" }
{ "encoding": "sparkplug_b", "seq": 0, "metric_count": 2, "historical_count": 0,
  "metrics": [ {"name": "Temperature", "alias": 1, "datatype": "Double", "value": 21.5,
                "is_historical": false, "is_null": false} ] }

oee_compute:

{ "planned_time_s": 28800, "run_time_s": 25200, "ideal_cycle_time_s": 2.0,
  "total_count": 12000, "good_count": 11800 }
{ "availability": {"raw": 0.875, "value": 0.875, "capped": false},
  "performance": {"value": 0.952381}, "quality": {"value": 0.983333},
  "oee": 0.819444, "oee_pct": 81.94 }

asset_inventory (active fingerprint):

{ "endpoints": ["press1", "cell5"] }
{ "asset_count": 2, "reachable_count": 2, "method": "active_fingerprint",
  "assets": [ {"endpoint": "press1", "protocol": "s7", "vendor": "Siemens/compatible",
               "model": "CPU 1511-1 PN", "firmware": "2.8", "reachable": true,
               "last_seen": "2026-06-28T10:00:00+00:00"} ] }

Diagnostics (multi-dimensional JSON for an agent to visualize)

diagnose_dataflow(endpoint="line1", ref="ns=2;i=5", freshness_threshold_s=30):

{ "verdict": "comms_ok_value_stale",
  "diagnosis": "Connected with good status, but the value is STALE (age 412s > 30s) — the source/field upstream has stopped updating this point.",
  "recommended_action": "Trace upstream: the device serves the last value fine, so suspect the source/scanner/field signal that should refresh it.",
  "hops": [ {"hop":"connect","protocol":"opcua","ok":true,"detail":"OPC-UA state=0"},
            {"hop":"read_tag","ref":"ns=2;i=5","ok":true,"detail":"5.0"},
            {"hop":"freshness","evaluated":true,"stale":true,"age_seconds":412.0} ] }

alarm_bad_actors(events=[…]):

{ "event_count": 55, "window_minutes": 0.82, "alarms_per_hour": 4024.4,
  "isa_18_2": {"ok_max":6,"manageable_max":12,"flood_min":30},
  "flood_verdict": "flood",
  "priority_distribution": {"high":50,"low":5},
  "pareto_sources_for_80pct": ["FIC101"],
  "top_offenders": [ {"source":"FIC101","count":50,"share_pct":90.9,"chattering":true,"standing":false} ],
  "chattering": ["FIC101"], "standing": [] }

tag_health(tags=[…]):

{ "evaluated": 4, "overall": "alarm", "offender_count": 3,
  "offenders": [ {"ref":"hot","latest":99,"flags":["out_of_range_alarm"],"severity":3},
                 {"ref":"flat","latest":5,"flags":["flatline"],"severity":2},
                 {"ref":"bad","latest":null,"flags":["bad_quality"],"severity":3} ] }

MCP server

ot-aiops mcp        # stdio transport; or the `ot-aiops-mcp` entry point

Safety & governance

  • Read-first. 51 of 57 tools are read-only. The 6 write/command tools (s7_write_db, mc_write_words, mqtt_publish, eip_write_tag, ethercat_write_sdo, ethercat_set_state) are OT-dangerous: governed at high risk_tier, off by default (dry-run), capture the BEFORE value/state for undo, require a double-confirm in the CLI, and (via policy) a recorded approver — MOC discipline. ethercat_set_state can START or STOP machine motion. 未经授权勿对生产控制系统写入.
  • Do not point this at a production control system without authorization. OT networks are safety-critical; even reads add load. Test against a simulator first.
  • All endpoint-returned text is sanitized (prompt-injection defense); secrets are never returned by any tool; MTConnect XML is parsed with DTD/entity declarations refused.
  • Every tool runs through the vendored governance harness: SQLite audit (~/.ot-aiops/audit.db), token/call budget + runaway breaker, risk-tier gate, undo recording.

Roadmap

  • EtherNet/IP PLC-5 / SLC-500 (PCCC) and Micro800 support (Logix tags are done in 0.2.0).
  • Passive asset discovery (SPAN/tap, no connections) alongside today's active fingerprint.
  • EtherCAT EoE / FoE / SoE mailbox protocols and full PDO-mapping decode (CoE SDO/PDO read+write and AL-state landed in 0.3.0 via the optional pysoem extra).
  • OPC-UA certificate security + real Alarms & Conditions subscriptions.
  • MTConnect streaming long-poll; Sparkplug B DataSet/Template deep expansion.

Missing a protocol, device, or feature? 缺功能提 issue/PR 欢迎留言 — open a GitHub issue or PR.

License

MIT © wei

Project details


Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

ot_aiops-0.3.0.tar.gz (150.7 kB view details)

Uploaded Source

Built Distribution

If you're not sure about the file name format, learn more about wheel file names.

ot_aiops-0.3.0-py3-none-any.whl (157.1 kB view details)

Uploaded Python 3

File details

Details for the file ot_aiops-0.3.0.tar.gz.

File metadata

  • Download URL: ot_aiops-0.3.0.tar.gz
  • Upload date:
  • Size: 150.7 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: uv/0.10.0 {"installer":{"name":"uv","version":"0.10.0","subcommand":["publish"]},"python":null,"implementation":{"name":null,"version":null},"distro":{"name":"macOS","version":null,"id":null,"libc":null},"system":{"name":null,"release":null},"cpu":null,"openssl_version":null,"setuptools_version":null,"rustc_version":null,"ci":null}

File hashes

Hashes for ot_aiops-0.3.0.tar.gz
Algorithm Hash digest
SHA256 b03390b293c31015f9efeb8cdbf5383fa47c397e6eadb6fab74f4aeafed8d485
MD5 3c17fd462f83cf31446443bdca82bdcb
BLAKE2b-256 17e4d96ab7ce9c3a1a49dd999772b2dfbd3b6e876829c45e283991aac23a53db

See more details on using hashes here.

File details

Details for the file ot_aiops-0.3.0-py3-none-any.whl.

File metadata

  • Download URL: ot_aiops-0.3.0-py3-none-any.whl
  • Upload date:
  • Size: 157.1 kB
  • Tags: Python 3
  • Uploaded using Trusted Publishing? No
  • Uploaded via: uv/0.10.0 {"installer":{"name":"uv","version":"0.10.0","subcommand":["publish"]},"python":null,"implementation":{"name":null,"version":null},"distro":{"name":"macOS","version":null,"id":null,"libc":null},"system":{"name":null,"release":null},"cpu":null,"openssl_version":null,"setuptools_version":null,"rustc_version":null,"ci":null}

File hashes

Hashes for ot_aiops-0.3.0-py3-none-any.whl
Algorithm Hash digest
SHA256 3f97cc89524c6274a68c28f111c45e8fae9205746ff06497dffc7f198144ce48
MD5 3accc1a88a92049cf3b3cb72bc513ae6
BLAKE2b-256 b01d019f346deb6e07a17dba3bcd08f544dc00b108347a8990d6425f14e2ae30

See more details on using hashes here.

Supported by

AWS Cloud computing and Security Sponsor Datadog Monitoring Depot Continuous Integration Fastly CDN Google Download Analytics Pingdom Monitoring Sentry Error logging StatusPage Status page