pyBuildingEnergy

pyBuildingEnergy Logo

Citation

Please cite us if you use this library: DOI

Documentation (New)

Check our new documentation in GitHub Pages: pybuildingenergy docs.

Find Us

Where to find our works:

Features

The new EPBD recast provides an update on building performance assessment through a methodology that must take into account various aspects such as the thermal characteristics of the building, the use of energy from renewable sources, building automation and control systems, ventilation, cooling, energy recovery, etc.

The methodology should represent the actual operating conditions, allow for the use of measured energy for accuracy and comparability purposes, and be based on hourly or sub-hourly intervals that take into account the variable conditions significantly impacting the operation and performance of the system, as well as internal conditions.

pyBuildingEnergy aims to provide an assessment of building performance both in terms of energy and comfort. The building energy needs are calculated with ISO 52016-1 (hourly method, single zone and multizone), validated against ANSI/ASHRAE Standard 140-2023 and the ISO 52016-1 verification cases (see Validation). The EPB system chain (EN 15316, EN 16798, EN 12831-3, EN 14511/14825, EN ISO 52000-1 and related standards) is described in the sections below.

The actual calculation methods for the assessment of building performance are the following:

  • the (sensible) energy need for heating and cooling, based on hourly or monthly calculations;
  • the latent energy need for (de-)humidification, based on hourly or monthly calculations;
  • the internal temperature, based on hourly calculations;
  • the sensible heating and cooling load, based on hourly calculations;
  • the moisture and latent heat load for (de-)humidification, based on hourly calculations;
  • the design sensible heating or cooling load and design latent heat load using an hourly calculation interval;
  • the conditions of the supply air to provide the necessary humidification and dehumidification.

The calculation methods can be used for residential or non-residential buildings, or a part of it, referred to as "the building" or the "assessed object".

ISO 52016-1:2018 also contains specifications for the assessment of thermal zones in the building or in the part of a building. The calculations are performed per thermal zone. In the calculations, the thermal zones can be assumed to be thermally coupled or not. ISO 52016-1:2018 is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase.

Use of UNI/TS 11300 input data

The project uses UNI/TS 11300 data to describe the technical systems connected to the building model. These data provide the system-side parameters needed after the ISO 52016-1 calculation, including heating and cooling emission, distribution, storage and generation efficiencies, generation COP, recovered losses, auxiliary energy and primary-energy factors. The same structure can also include domestic-hot-water and ventilation parameters and is used to assemble the combined ISO 52016-1 / systems / photovoltaic request.

Therefore, UNI/TS 11300 is used here as an input and system-accounting framework: ISO 52016-1 calculates the hourly building heating and cooling needs, while the UNI/TS 11300 parameters are used to describe how those needs are served and converted into system and energy-carrier quantities. The repository does not claim to implement a complete standalone UNI/TS 11300 certification calculation; the example archetypes and payload builder are available in examples/building_examples.py.

--

Validation - ASHRAE 140-2023 And ISO 52016-1 (New)

Two independent validation harnesses run the ISO 52016-1 engine on the BESTEST test cell (8 m x 6 m x 2.7 m, 12 m2 of glazing, Denver climate) and write one HTML report per case.

ANSI/ASHRAE Standard 140-2023, Section 7 — building thermal envelope and fabric load tests, with the inputs of the 2023 specification and its accompanying files (raised floor, 2023 glazing, altitude-corrected air flows, Table 7-7/7-9 surface coefficients, overhangs and side fins per Figures 7-3 to 7-6, two-zone sunspace Case 960 on the multizone engine).

Annex A3 test group Ranges met Required (Table A3-14) Result
Thermal Fabric Low Mass (cases 600–695) 20 of 21 18 pass
Thermal Fabric High Mass (cases 900–995) 17 of 19 17 pass (no margin)

Ranges not met (outside the ASHRAE 140 acceptance range; 2020 edition, Addendum b): Case 900 annual cooling (2.944 MWh), and the 650−600 and 920−900 cooling differences. The acceptance-range values are not reproduced here: they are in Tables A3-1 to A3-4 of Annex A3 (ANSI/ASHRAE Standard 140-2023, incorporating Addendum b to 140-2020). Documented deviations: the interior solar distribution fractions of Table 7-13 are not applied (the engine distributes transmitted solar by area) and ISO 52016-1 Annex F Method 1 shades direct radiation only.

PYTHONPATH=src python examples/ashrae140_bestest/run_comparison.py     # Annex A3 check of all cases
PYTHONPATH=src python examples/ashrae140_bestest/generate_reports.py   # reports/index.html

EN ISO 52016-1:2017, Section 7.2 — the six verification cases of Table 27 with the standard's own adapted inputs (operative-temperature control, floor to outdoor air, 0.41 ach, F_w = 0.90) and its BESTEST climate file.

Case Annual heating vs Table 28 Annual cooling vs Table 29 Annual mean T_op vs Table 30
600 +9.5% +8.5% −0.09 K
640 +9.4% +10.3% −0.36 K
900 +6.2% +6.4% +0.01 K
940 −1.9% +5.3% −0.17 K
600FF — — +0.11 K
900FF — — +0.14 K

ISO 52016-1 defines no acceptance tolerance; the tests use ±10% on the annual needs. Case 900 is compared with the corrected Tables 28/29 values (the printed heating and cooling columns are swapped). The ISO climate spreadsheet is ISO copyright content and is not shipped: place it in Standards/ to reproduce these numbers (otherwise a TMY3 approximation is used).

PYTHONPATH=src python examples/iso52016_bestest/run_comparison.py
PYTHONPATH=src python examples/iso52016_bestest/generate_reports.py    # reports/index.html

Details, inputs and remaining gaps: ASHRAE 140 README and ISO 52016-1 README.

Sources not distributed

The following content is copyright ASHRAE / ISO and is not included in this repository, because we are not authorized to share parts, tables or limits of the standards:

Content Where to find it in the standard Local file (git-ignored)
ASHRAE 140 acceptance ranges, low-mass heating / sensible cooling ANSI/ASHRAE Standard 140-2023, Normative Annex A3, Tables A3-1 and A3-2 Standards/local_reference_data/ashrae140_2023_annex_a3.json
ASHRAE 140 acceptance ranges, high-mass heating / sensible cooling Annex A3, Tables A3-3 and A3-4 same file
ASHRAE 140 group pass criteria Annex A3, Table A3-14 (counts quoted above) —
ISO 52016-1 reference results (monthly/annual needs, operative temperatures, peaks, hourly January 4) EN ISO 52016-1:2017, clause 7.2.4, Tables 28–34 Standards/local_reference_data/iso52016_1_2017_tables_28_34.json
ISO 52016-1 BESTEST climate data EN ISO 52016-1:2017, clause 7.2.2.12 (accompanying spreadsheet) Standards/ISO_52016_1_BESTEST_ClimData_2016.08.24.xls

Annex A3 was introduced by Addendum b to ANSI/ASHRAE Standard 140-2020 and is incorporated in the 2023 edition. Anyone who owns ANSI/ASHRAE Standard 140 (and EN ISO 52016-1 for the ISO cases) can reproduce every check: copy the values into the local files following the templates annex_a3_ranges.template.json and iso_reference_tables.template.json, which name the table each value comes from. Without them the cases still run, range and reference checks report "not available" and the related tests are skipped. Reports and console output never print the range or reference values; the published reports cite the table of the standard instead.

ISO 52016-1 Engine Options And Fixes (New)

Changes to ISO52016.Temperature_and_Energy_needs_calculation and the multizone engine made during the validation work:

  • hvac_control_variable="operative" | "air": the ideal heating/cooling control acts on the operative temperature (ISO 52016-1 default) or on the zone air temperature (EnergyPlus-style thermostat, as required by ASHRAE 140).
  • construction_class can be set per surface (ISO 52016-1 Table B.13); the building-level value remains the fallback.
  • Windows: the transmitted solar gain applies the correction factor F_w of Formula E.3 (solar_transmittance_correction_factor, default 0.90) and the window's own frame_area_fraction; transparent elements have solar absorptance 0 at the external node (clause 6.5.7.3).
  • external_convection_model ("doe2", "mowitt", "blast", "simplecombined") is now applied in the single-zone engine too (it was accepted but had no effect); internal_convection_model="tarp", external_radiation_model="dynamic" and sky_temperature_model remain available. The default "table" models are unchanged.
  • Side fins (ISO 52016-1 Annex F, F.5/F.6 combined with F.19–F.22) per window: "side_fins": {"left": {"depth": 1.0, "distance": 0.0}, "right": {...}}, in addition to overhangs (F.4) and Annex F obstacles.
  • simulate_envelope_multizone_free_floating(..., c_int_per_A_us=10000): the zone air/furniture heat capacity is configurable, as in the single-zone engine.

Weather Data

The tool can use weather data coming from 2 main sources:

More details in the example folder.

Domestic Hot Water - DHW

  • Calculation of volume and energy need for domestic hot water according to EN 12831-3.
  • Assessment of DHW system design heat load with EN 12831-3 storage switch points, time lag, effective reheating power and supply-curve sizing.

For the audit trail between the standard, code and outputs, open DHW EN 12831-3 Implementation Audit.

Space Emission Systems - EN 15316-2 (New)

EmissionSystemCalculator evaluates space-heating and water-based space-cooling emission effects before generation. It can be used to account for emitter and control effects, equivalent internal-temperature changes, embedded emitter losses, emission auxiliary electricity and annual emission expenditure factors.

For an audit trail between the standard, code and output files, open Emission EN 15316-2 Implementation Audit.

Auxiliary energy. By default the emission auxiliary energy is the fans only (EN 15316-2 eq. 27-28). Control-device power (control_power_W, control_count) is included only when the system is an electrical control system with auxiliary energy (Table A.12), by setting electric_control_aux: true.

Undersized emitters (EN 15316-1 eq. 16). If the emitter cannot deliver the expected output, the deficit is backup energy when backup_available: true (Q_*_em_back_out_kWh). Otherwise it is reported as unmet load (Q_*_em_unmet_kWh) and a warning is raised when it exceeds undersize_tolerance (default 5 % of the expected output). With backup_available: true the backup energy is added to the heating-system demand passed to distribution and generation (backup input taken equal to its output; backup losses not modelled). In undersized hours the literal EN 15316-2 eq. 22 gives a negative Q_*_em_ls (the capped emitter output is below the expected output); the energy identities eq. 22-23 are kept as written.

Emission output at the modified set point. simulate_config (emission-only path) recalculates the building need with ISO 52016 at the equivalent set points, as EN 15316-2 requires. Set options.emission_inc_method: "approximate" to use the temperature-ratio approximation instead: it is faster (about half the time, since ISO 52016 runs once) but the results are approximate, and a notification is raised. The difference is material for cooling (the example gives about 790 kWh with recalculation and 401 kWh with the approximation). The standalone EmissionSystemCalculator has no building, so it can only use the approximation unless Q_*_em_out_inc_kWh is supplied.

Fan auxiliary energy (EN 15316-2 eq. 14). W_fan = n_fan · P_fan · t_h,rL / 1000. Provide the system operation time per step as t_h_rl (hours, from the EN 15316-1 operating schedule). If it is not given, the run time is estimated as the load factor (emitted energy / nominal power) times the time step, instead of assuming the fan runs the full hour whenever there is output.

Sign convention for cooling (note on the standard). The implementation uses theta_int,inc = theta_int,ini + SUM(delta) for both heating and cooling, as in the hourly procedure (EN 15316-2:2017, eq. 16-17), with cooling deltas entered as negative values (Table B.11). The standard is not fully consistent on this point: the general description (section 5.2, eq. 1a/1b) gives theta_C,int,inc = theta_C,int,ini - delta. With the negative Table B.11 values the two formulas give opposite results, so the cooling sign should be checked against the national annex or the standard's clarification before using cooling results for compliance.

Water-Based Distribution Systems - EN 15316-3 (New)

DistributionSystemCalculator evaluates water-based distribution systems for space heating, space cooling and DHW. It calculates pipe thermal losses, recoverable distribution losses, pump auxiliary electricity, recoverable pump heat and recovered pump heat in the fluid before the generator calculation.

For the audit trail, open Distribution EN 15316-3 Implementation Audit.

Heating And DHW Storage Systems - EN 15316-5 (New)

StorageSystemCalculator evaluates single-volume Method B storage systems for space heating and DHW. It calculates storage standing losses from product standby-loss data or a direct heat-loss coefficient, storage charging pump auxiliary electricity, recoverable storage losses and heat recovered in the medium before the generator calculation.

For the audit trail, open Storage EN 15316-5 Implementation Audit.

Heat Pump Generation - EN 15316-4-2 (New)

HeatPumpSystemCalculator evaluates heat-pump generation for:

  • space heating,
  • domestic hot water (DHW),
  • and an optional simplified reversible space-cooling branch with an EER map.

The heating and DHW calculation follows EN 15316-4-2:2017's Method A (clause 6, hourly/bin) structure: outdoor/source temperature bins, product heating capacity and COP maps (EN 14511-series, Path A), part-load performance per Eq.(14)-(30), runtime/capacity checks, auxiliary energy, optional simplified storage losses, backup energy and SPF outputs. The runnable examples use the EN 16798 cooling modules by default; the older heat-pump EER cooling branch is still available with --calculation-path heat-pump-cooling.

For a clause-by-clause audit trail between the standard, the implementation and the output files, open Heat Pump EN 15316-4-2 Implementation Audit.

Additional Generation And Renewable Modules - EN 15316-4-1, EN 15316-4-4, EN 15316-4-5, EN 15316-4-3/4-6 (New)

The Athens and Bolzano system workflow can now switch the heating/DHW generator away from the default heat pump:

  • BoilerGeneratorCalculator implements EN 15316-4-1 (combustion generators - gas/oil boilers and biomass) with the standard's load-interpolated efficiency/loss method, temperature correction, standby losses and auxiliaries.
  • CogenerationSystemCalculator implements an EN 15316-4-4 thermal-led CHP boundary with fuel input, useful electricity, self-consumption/export and backup heat.
  • DistrictEnergySystemCalculator implements an EN 15316-4-5 district heating/cooling substation boundary.
  • RenewableEnergySystemCalculator implements the EN 15316-4-3/4-6 solar thermal and PV accounting branch used by the examples and STREPIN runner.

Audit pages: Generation EN 15316-4-1/4-4/4-5 and Renewables EN 15316-4-3/4-6.

Heat Pump Product Performance - EN 14511 And EN 14825 (New)

HeatPumpPerformanceDataCalculator normalizes heat-pump rating data from EN 14511-style capacity/COP/EER points and calculates EN 14825 part-load inspection values. The examples use this path by default and apply the EN 14825 water-based part-load correction to heating/DHW COP and EN 16798-13 cooling EER.

For the audit trail between the standards, code and outputs, open EN 14511 / EN 14825 Product Performance Implementation Audit.

Cooling System Modules - EN 16798-9, EN 16798-15 And EN 16798-13 (New)

The heat-pump examples now treat space cooling with the cooling-side EN 16798 standards:

  • CoolingSystemCalculator implements EN 16798-9 operating conditions and the handoff of cooling requests to storage or generation.
  • CoolingStorageSystemCalculator implements EN 16798-15 chilled-water storage heat gains and pump auxiliary energy.
  • CoolingGenerationSystemCalculator implements EN 16798-13 compression cooling generation using cooling capacity/EER product maps or nominal EER fallback data.

For the audit trail between the standards, code and outputs, open Cooling EN 16798 Implementation Audit.

For the whole end-to-end workflow that interconnects EN ISO 52016, EN 12831-3, EN 15316, EN 16798, EN 14511 and EN 14825 in the Athens and Bolzano examples, open Heat-Pump Example Simulation Workflow Audit.

import pandas as pd
import pybuildingenergy as pybui

heating_map = pd.DataFrame({
    "source_temperature_C": [-7, -7, 2, 2, 7, 7],
    "sink_temperature_C": [35, 55, 35, 55, 35, 55],
    "capacity_kW": [5.0, 4.0, 6.0, 5.0, 7.0, 6.0],
    "cop": [3.2, 2.4, 3.8, 2.8, 4.2, 3.2],
})

cooling_map = pd.DataFrame({
    "source_temperature_C": [25, 25, 35, 35],
    "sink_temperature_C": [7, 18, 7, 18],
    "capacity_kW": [5.0, 6.0, 4.0, 5.0],
    "eer": [3.0, 3.6, 2.5, 3.1],
})

loads = pd.DataFrame({
    "T_ext": [-5, 0, 5, 25],
    "Q_H_kWh": [4.0, 3.0, 1.0, 0.0],
    "Q_C_kWh": [0.0, 0.0, 0.0, 2.0],
    "Q_W_kWh": [0.5, 0.5, 0.5, 0.5],
})

calc = pybui.HeatPumpSystemCalculator({
    "heating_performance_map": heating_map,
    "dhw_performance_map": heating_map,
    "cooling_performance_map": cooling_map,
    "source_type": "air",
    "demand_unit": "kWh",
    "dhw_target_temperature_C": 55,
    "dhw_sink_temperature_C": 55,
    "external_auxiliary_power_W": 100,
})

result = calc.run_timeseries(loads)
print(result.summary["SPF_HW_gen"])
print(result.summary["SEER_C_gen"])

Run The Heat Pump Example

The runnable examples are:

python -m pip install -r requirements.txt
python examples/heat_pump_15316_4_2_example.py --scenario athens
python examples/heat_pump_15316_4_2_example.py --scenario bolzano

There is also a Bolzano convenience wrapper:

python examples/heat_pump_15316_4_2_bolzano_example.py

The Athens scenario uses an Athens PVGIS weather location, a Greece DHW calendar, the EN 12831-3 Annex B Table B.2 single-family dwelling hourly DHW profile and a 26 C cooling setpoint. The Bolzano scenario uses Bolzano coordinates, an Italy DHW calendar, the same residential Annex B hourly DHW profile, a tighter solar-exposed envelope and an air-to-water heat-pump map sized for a 120 m2 useful-floor-area residential building. In both cases the example geometry is a two-floor building with a 60 m2 footprint; roof and ground-slab areas are therefore 60 m2, while net_floor_area remains 120 m2.

Each scenario runs ISO52016 for the example building, applies EN 15316-2 emission effects, EN 15316-3 distribution effects, EN 15316-5 heating/DHW storage effects and the EN 16798 cooling-side modules by default, calculates an hourly DHW profile and the EN 12831-3 DHW design sizing, runs the generator calculations and writes:

  • examples/outputs/heat_pump_15316_4_2_<scenario>/iso52016_loads_with_dhw.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/dhw_12831_3_design_timeseries.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/dhw_12831_3_design_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/building_geometry_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/emission_15316_2_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/emission_15316_2_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/distribution_15316_3_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/distribution_15316_3_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/storage_15316_5_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/storage_15316_5_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_16798_9_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_16798_9_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_storage_16798_15_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_storage_16798_15_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_generation_16798_13_hourly_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/cooling_generation_16798_13_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/performance_14511_14825_rating_points.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/performance_14511_14825_heating_map.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/performance_14511_14825_cooling_map.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/performance_14511_14825_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/heat_pump_hourly_allocated_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/heat_pump_bin_results.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/heat_pump_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/combined_generation_summary.csv
  • examples/outputs/heat_pump_15316_4_2_<scenario>/inspection_index.html

Open inspection_index.html in a browser to inspect the visual outputs. The page links to:

  • a user-facing overview of annual loads, final electricity, monthly trends, seasonal performance and useful-area intensities;
  • a workflow handoff plot that shows how heating, cooling and DHW loads move through the implemented standards;
  • sanity-check plots for geometry, peak loads versus active capacity, backup shares and unmet loads;
  • EN 12831-3 DHW design-day needs, storage switch curves, residual storage and effective reheating power;
  • the existing ISO52016 building report generated with Graphs_and_report;
  • the whole simulation workflow audit trail;
  • daily input time series for heating, cooling, DHW and temperatures;
  • EN 15316-2 emission time series and monthly aggregate plots;
  • EN 15316-3 distribution time series and monthly aggregate plots;
  • EN 15316-5 storage time series and monthly aggregate plots;
  • EN 16798-9 cooling operating-condition time series;
  • EN 16798-15 cooling storage time series and aggregate plots;
  • EN 16798-13 cooling generation time series and bin plots;
  • EN 14511 / EN 14825 rating and part-load performance plots;
  • allocated heat-pump electricity time series;
  • monthly demand, electricity, SPF and SEER summaries;
  • bin-method energy balance plots;
  • bin COP/EER, capacity and runtime plots;
  • an annual energy-flow Sankey diagram.

The default calculation path is the full chain:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path full
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path full

To exercise the newly added generator and renewable branches:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path full-renewables
python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path boiler-full
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path chp-full
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path district-full

The same choices can be made explicitly with --heating-generation-method en15316-4-2|en15316-4-1|en15316-4-4|en15316-4-5 and --renewable-method en15316-4-3-4-6.

To keep the full subsystem chain but use the previous synthetic product maps without EN 14825 part-load correction, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path full --performance-data-method simple

To combine the direct ISO52016/DHW path with the new EN 14511/EN 14825 product performance stage, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path simple --performance-data-method en14511-14825

By default, the full path also runs EN 12831-3 DHW system sizing and passes the selected DHW storage volume and design flow into EN 15316-5 and EN 15316-3. To keep the earlier fixed DHW storage/distribution assumptions, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --dhw-design-method simple

The EN 12831-3 sizing target can be changed with --dhw-sizing-mode check, --dhw-sizing-mode size_storage, --dhw-sizing-mode size_power or --dhw-sizing-mode auto.

To run the previous detailed path with EN 15316-2 and EN 15316-3 but without EN 15316-5 storage, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path emission-distribution
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path emission-distribution

To run only EN 15316-5 storage between direct ISO52016/DHW loads and the heat pump, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path storage-only
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path storage-only

To bypass only the EN 16798-15 cooling storage module while retaining EN 15316-2, EN 15316-3, EN 15316-5 and EN 16798-13, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path no-cooling-storage
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path no-cooling-storage

To retain the earlier reversible heat-pump cooling branch instead of EN 16798-13, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path heat-pump-cooling
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path heat-pump-cooling

To run EN 15316-2 emission effects but bypass EN 15316-3 distribution and EN 15316-5 storage, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path emission-only
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path emission-only

To reproduce the earlier simple calculation without EN 15316-2, EN 15316-3, EN 15316-5 or EN 16798 effects, use:

python examples/heat_pump_15316_4_2_example.py --scenario athens --calculation-path simple
python examples/heat_pump_15316_4_2_example.py --scenario bolzano --calculation-path simple

Simple mode writes to examples/outputs/heat_pump_15316_4_2_<scenario>_simple unless --output-dir is specified.

By default the script uses PVGIS weather for the selected scenario, so it needs internet access. To run with a local EPW file instead:

python examples/heat_pump_15316_4_2_example.py --scenario athens --weather-source epw --path-weather-file path/to/weather.epw

Italian STREPIN Archetypes (New)

The STREPIN workbook in examples/strepin_archetypes/ can be converted into pyBuildingEnergy BUI cases and simulated with the European-standard generator chain. Package IDs reproduce the workbook's pre/post cases:

python examples/strepin_archetypes/run_italian_strepin_engine.py --archetypes all --packages P00 --system-chain en-standards
python examples/strepin_archetypes/run_italian_strepin_engine.py --archetypes RMF_E1_B --packages P00,P09 --system-chain en-standards --write-hourly
python examples/strepin_archetypes/run_italian_strepin_engine.py --archetypes all --packages all --system-chain en-standards

Arbitrary combinations of the workbook measure levels can also be simulated without adding a new workbook package:

python examples/strepin_archetypes/run_italian_strepin_engine.py --archetypes RMF_E1_B --measure-levels wall=2,roof_floor=2,windows=2,heating=3,pv=2 --system-chain en-standards

Additional renovation overlays that are considered in the European EPB suite but are not explicit STREPIN workbook package levels can be layered on top:

python examples/strepin_archetypes/run_italian_strepin_engine.py --archetypes RMF_E1_B --measure-levels wall=2,roof_floor=2,windows=2,heating=3,pv=2 --extra-measures lighting-controls,ventilation-hrv,bacs-b,solar-thermal,battery-5 --system-chain en-standards

The STREPIN runner now reports EN ISO 52000-1 delivered/exported primary energy, EN 15193-1 lighting, EN 16798-5/7 ventilation and heat recovery, EN 15232-1 / EN ISO 52120-1 BACS factors, EN 15459-1 global cost, and deeper EN 15316-4 options for biomass, CHP and district heat where selected.

Climate zone B now defaults to examples/Palermo_PVGIS_TMY.epw, downloaded from PVGIS and normalized for pvlib.read_epw. Open Italian STREPIN Archetype Engine Audit for the data and workflow crosswalk.

The script checks that the ISO52016 run produces both heating and cooling demand and that DHW demand is non-zero before running the heat-pump calculation.

Primary Energy - Heating System (New)

The EN 15316 series covers the calculation method for system energy requirements and system efficiencies. This family of standards is an integral part of the EPB set and covers:

EN 15316 Modular Structure (New)

  • EN 12831-3: Domestic hot-water energy needs and DHW design heat-load/sizing
  • EN 15316-1: General and expression of energy performance (Modules M3-1, M3-4, M3-9, M8-1, M8-4)
  • EN 15316-2: Emission systems (heating and cooling)
  • EN 15316-3: Distribution systems (DHW, heating, cooling)
  • EN 15316-4-X: Heat generation systems:
    • 4-1: Combustion boilers
    • 4-2: Heat pumps
    • 4-3: Solar thermal and photovoltaic systems
    • 4-4: Cogeneration systems
    • 4-5: District heating
    • Biomass/solid-fuel default wrapper for EN 15316-4 generation workflows
  • EN 15316-5: Storage systems

Cross-Cutting EPB Accounting (New)

  • EN ISO 52000-1: delivered/exported energy and primary-energy accounting
  • EN 15193-1: lighting energy and LENI-style indicators
  • EN 16798-5/7: mechanical ventilation, heat recovery and fan electricity
  • EN 15232-1 / EN ISO 52120-1: BACS service factors
  • EN 15459-1: global cost and annualized cost calculation

EN 16798 Cooling Modular Structure (New)

  • EN 16798-9: Cooling systems, operating conditions and M4-1/M4-4 handoff
  • EN 16798-13: Cooling generation, compression systems
  • EN 16798-15: Cooling storage
  • EN 16798-13 non-compression cooling generators, such as absorption, adsorption, desiccant or evaporative cooling

Heat Pump Product Rating Structure (New)

  • EN 14511-1: Heat-pump and chiller rating terms, including COP and EER definitions
  • EN 14511-2: Rating and application-condition temperature points for air-to-water heat pumps and chillers
  • EN 14825: Part-load capacity-ratio and degradation-coefficient correction for heating COP and cooling EER

For space heating, applicable standards include EN 15316-1, EN 15316-2-1, EN 15316-2-3 and the appropriate parts of EN 15316-4 depending on the system type, including losses and control aspects.

Single zone and Multiple Zones (New)

EN ISO 52016 - Multi-zone Calculation and Adjacent Zones

EN ISO 52016 defines that:
The calculation now allows the definition of several thermal and non-thermal zones adjacent to the considered zone.

External Adjacent - Unheated Zone: It is possible to define an unheated adjacent zone in contact with the considered thermal zone.
The length of the separating wall may be entirely or partially connected to the considered zone.

The calculation involves:

  1. Determining the internal temperature of the non-thermal zone.
  2. Evaluating the heat exchange with the thermal zone.

External Adjacent - Heated Zone: In this case, the wall between the two zones is considered adiabatic (no heat exchange). Adjusted Coefficient: To account for the different temperatures between zones (e.g., thermal and non-thermal), an adjusted coefficient is calculated.

Assumptions and Simplifications

The standard defines various assumptions specified in section 6.5.3 - Assumptions and specific conditions.
In general, it aims to simplify the zoning approach by reducing the number of zones to a minimum (ISO EN 52016-2:2018).

It also emphasizes that:

A multi-zone calculation with interactions between the zones requires significant and often arbitrary input data (on transmission properties and air flow direction and size).
It can also lead to other technical and procedural complications that add uncertainties to the results.
A further complication can be the involvement of different heating, cooling and ventilation systems for different zones, which adds to the complexity and arbitrariness of the input and modelling.

Key Remark: Therefore, the benefits of calculations with thermally coupled zones can be smaller than the drawbacks.


EN 16798-7 & 16798-1 - Natural ventilation and profiles (New)

Compute the ventilation heat transfer coefficient [W·K⁻¹] of the thermal zone either:

  • from natural ventilation (ISO 16798-7:2017, single-sided airing via windows, wind/stack), or
  • from occupancy-driven flow (simplified volumetric rate per floor area).

For more detail refers to natural ventilation.

Due to the need to have profiles of occupancy and consumption of buildings for some uses, tables of profiles useful for evaluating, occupancy, lights, heating, cooling, internal gains have been implemented. These tables are provided by ANNEX A of ISO EN 16798-1. In the tool they are available here: Table

EN 16798-5-1 - Mechanical Ventilation AHU (New)

A sensible, balanced-airflow air-handling-unit model based on EN 16798-5-1 can be configured as a mechanical_supply ventilation component. It computes heat recovery, bypass and frost behaviour, capacity-limited heating/cooling coils and fan electricity per timestep, and couples into the ISO 52016-1 zone balance as a supply-air stream. Existing configurations are unchanged unless the component is configured.

"building_parameters": {
    "ventilation": {
        "components": [
            {   # envelope leakage: no profile, always active
                "name": "infiltration",
                "ventilation_type": "constant_ach",
                "air_changes_per_hour": 0.15,
            },
            {   # balanced AHU with sensible heat recovery
                "name": "ahu",
                "ventilation_type": "mechanical_supply",
                "supply_flow_m3_h": 3600.0,
                "sensible_heat_recovery_efficiency": 0.784,
                "supply_temperature_setpoint_c": 18.0,
                "heating_coil_max_power_w": 15000.0,
                "supply_fan_specific_power_w_per_m3_s": 750.0,
                "extract_fan_specific_power_w_per_m3_s": 750.0,
                "profile": "ventilation_profile",  # flow fraction in [0, 1]
            },
        ],
    },
},

For the implemented / simplified / not-included scope, all configuration keys and the hourly diagnostic columns, open Ventilation AHU EN 16798-5-1 Implementation Audit.

Input Quality check (New)

The data provided before being used for the simulation are processed and evaluated to be considered fit for the simulation. This process includes a series of checks that allow to identify any potential errors. For more details refers to Input Quality check.

Limitations

The library is developed with the intent of demonstrating specific elements of calculation procedures in the relevant standards. It is not intended to replace the regulations but to complement them, as the latter are essential for understanding the calculation. This library is meant to be used for demonstration and testing purposes and is therefore provided as open source, without protection against misuse or inappropriate use.

The information and views set out in this document are those of the authors and do not necessarily reflect the official opinion of the European Union.

Getting Started

Install the latest version of the library:

pip install pybuildingenergy

Building - System Inputs

Example

New examples will follow soon...

Run a simulation with progress and HTML reports

From the repository root (paths are relative, so the commands work on any machine):

# single zone (building + emission system)
python examples/thermal_report_example.py \
  --config examples/FH_Poland_DC_baseline_two_floors.json \
  --mode single-zone

# multizone (ground floor + first floor)
python examples/thermal_report_example.py \
  --config examples/FH_Poland_DC_multizone_ideal_envelope.json \
  --mode multizone

The engine shows a progress bar (tqdm) while it computes the hourly balance. The reports are written to examples/outputs/thermal_report/ (use --output-dir <folder> to change it):

  • thermal_report_single_zone.html or thermal_report_multizone.html
  • hourly, daily and monthly charts (ECharts): thermal need, operative temperature per zone, outdoor temperature and outdoor relative humidity

The Poland case JSON files are not shipped with the package: they must be placed in examples/ (or the --config path must point to them).

Contributing and Support

Bug reports / Questions
If you encounter a bug, please create an issue detailing it. Provide steps to reproduce and a code snippet if possible.

Code contributions
We welcome and appreciate contributions! Every contribution, no matter how small, makes a difference.

License

Author

Acknowledgment

This work was carried out within European projects:

  • Infinite - EU Horizon 2020 (grant agreement No. 958397)
  • Moderate - Horizon Europe (grant agreement No. 101069834)
  • BREEZE - Building Renovation Efforts for Zero Emission Buildings, co-funded by the European Union LIFE programme (grant agreement No. 101215197)

The DHW calculation was developed with data and methods from the EPB Center spreadsheet.

References

EPBD and context

Building energy needs, climate and validation

  • EN ISO 52000-1:2017 - Energy performance of buildings: overarching EPB assessment (delivered/exported and primary energy)
  • EN ISO 52010-1:2017 - External climatic conditions: conversion of climatic data for energy calculations
  • EN ISO 52016-1:2017 - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads (hourly method, Annex F shading, Annex G dynamic transparent elements, Section 7.2 verification cases)
  • CEN ISO/TR 52016-2:2017 - Explanation and justification of ISO 52016-1 and ISO 52017-1
  • ISO 13370:2017 - Heat transfer via the ground (ground model of the ISO 52016-1 engine)
  • ISO 13789:2017 - Transmission and ventilation heat transfer coefficients (surface heat-transfer coefficients)
  • ANSI/ASHRAE Standard 140-2023 - Method of Test for Evaluating Building Performance Simulation Software (Section 7 test cases; Annex A3 acceptance criteria, introduced by Addendum b to ANSI/ASHRAE Standard 140-2020)

Domestic hot water

  • EN 12831-3:2017 - Domestic hot water systems heat load and characterization of needs
  • EN 806-3, EN 12897 and EN 13203-2 - referenced as optional input-data sources for DHW design and product data
  • EN 89 - referenced for gas-fired storage water-heater standby losses in the EN 15316-4-1 generator

System energy requirements - EN 15316 series

  • EN 15316-1:2017 - System energy requirements and system efficiencies: general and expression of energy performance
  • EN 15316-2:2017 - Space emission systems (heating and cooling)
  • EN 15316-3:2017 - Space distribution systems (DHW, heating and cooling)
  • EN 15316-4-1:2017 - Space heating and DHW generation systems, combustion systems (boilers, biomass)
  • EN 15316-4-2:2017 - Space heating generation systems, heat-pump systems (Method A, clause 6)
  • EN 15316-4-3 / EN 15316-4-6 - Thermal solar systems and photovoltaic systems
  • EN 15316-4-4:2007/2008 - Cogeneration systems
  • EN 15316-4-5:2017 - District heating and cooling
  • EN 15316-5:2017 - Space heating and DHW storage systems

Cooling, ventilation and indoor environment - EN 16798 series

  • EN 16798-1:2019 - Indoor environmental input parameters (occupancy, lighting, appliance and setpoint profiles, Annex A)
  • EN 16798-5-1:2017 - Calculation methods for energy requirements of ventilation and air-conditioning systems (air-handling unit model)
  • EN 16798-7:2017 - Calculation methods for the determination of air flow rates in buildings including infiltration (natural ventilation)
  • EN 16798-9:2017 - Calculation methods for energy requirements of cooling systems
  • EN 16798-13:2017 - Calculation of cooling systems: generation
  • EN 16798-15:2017 - Calculation of cooling systems: storage

Heat-pump and chiller product performance

  • EN 14511-1:2022 - Air conditioners, liquid chilling packages and heat pumps: terms and definitions
  • EN 14511-2:2022 - Air conditioners, liquid chilling packages and heat pumps: test conditions
  • EN 14825:2022 - Seasonal performance and part-load conditions for air conditioners, chillers and heat pumps

Lighting, building automation and economics

  • EN 15193-1:2017 - Energy requirements for lighting
  • EN 15232-1:2017 / EN ISO 52120-1 - Impact of building automation, controls and building management (BACS factors)
  • EN 15459-1:2017 - Economic evaluation procedure for energy systems in buildings (global cost)

Validation data sources

Metadata

Release files for pybuildingenergy 2.1.0

For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.

Source distribution (sdist)

Source distribution for pybuildingenergy 2.1.0
File Size Uploaded Provenance
pybuildingenergy-2.1.0.tar.gz 2.3 MB Without provenance Details

Built distribution (wheel)

Table of built distributions (wheels) for pybuildingenergy 2.1.0
File Interpreter ABI Platform
pybuildingenergy-2.1.0-py3-none-any.whl Python 3 none any Details

Total release size: 4.5 MB

Release files / pybuildingenergy-2.1.0.tar.gz

Download URL pybuildingenergy-2.1.0.tar.gz
Size 2.3 MB
Tags Source
SHA-256 checksum
How to use checksums
cf3f39f8b6b6df7c5747e7f32b6cc5c75875fa086bb4ed8a0f1fc4c116e4ac3e
BLAKE2b-256 checksum
How to use checksums
422241b9ac9b4703c89af23eb95a2e38a75456e44f41b4e8357b4f88d4ae271b
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.11.11

Release files / pybuildingenergy-2.1.0-py3-none-any.whl

Download URL pybuildingenergy-2.1.0-py3-none-any.whl
Size 2.3 MB
Tags Python 3
SHA-256 checksum
How to use checksums
1e1db4b8bfe2de2dea09a45caf3a08055c7b7ea75970d3530d6528ff454e8134
BLAKE2b-256 checksum
How to use checksums
5d290fb6a3d0772ec722c3284d75a1dac6c42f4573c2cff3fa70d177097ffa5f
Upload date
Uploaded using Trusted Publishing?
What is trusted publishing?
No
Uploaded via twine/7.0.0 CPython/3.11.11

Security for pybuildingenergy 2.1.0

Provenance

Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.

No provenance found

None of the files in this release were uploaded with provenance metadata.

A note on package security

PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.

Anthropic, PBC Visionary sponsor Bloomberg Visionary sponsor Hudson River Trading Visionary sponsor Meta Visionary sponsor NVIDIA Visionary sponsor Microsoft Sustainability sponsor Depot Continuous Integration AWS Cloud computing and Security Sponsor Datadog Monitoring Fastly CDN Google Download Analytics Sentry Error logging StatusPage Status page