pyhvac generates infrared commands for air conditioners and heat pumps, in pure Python. Give it a brand, a model and the state you want (power, mode, setpoint, fan, swing, features); it returns the IR signal, ready for a Broadlink (or any IR blaster that takes Pronto or raw timings). It decodes those signals too.
It covers 689 models and remotes from 121 brands. Most protocols were ported from IRremoteESP8266 and checked against recordings of what that library sent; the others are pyhvac's own.
Credits for the protocol work go to:
- Scott Kyle https://gist.github.com/appden/42d5272bf128125b019c45bc2ed3311f
- mat_fr https://www.instructables.com/id/Reverse-engineering-of-an-Air-Conditioning-control/
- user two, mathieu, vincent https://www.analysir.com/blog/2014/12/27/reverse-engineering-panasonic-ac-infrared-protocol/
- all the people who contributed to https://github.com/crankyoldgit/IRremoteESP8266
- SmartIR https://github.com/smartHomeHub/SmartIR and all the people who contributed its climate captures: they were the evidence for many models and protocol variants (pyhvac ships none of their files)
- quadjojo's ha-aeg-infrared https://github.com/quadjojo/ha-aeg-infrared, for verifying the AEG Chillflex Pro AXP26U558HW on a unit
Installation
pip install pyhvac
pyhvac has no dependencies and no compiled code.
Use
from pyhvac import registry
from pyhvac.ir.formats import to_broadlink
from pyhvac.state import HvacState
device = registry.get_device("Daikin", registry.models("Daikin")[0])
command = device.encode(None, HvacState(True, "cool", 24.0))
packet = to_broadlink(command.signal) # send it with a Broadlink RM
registry.brands()lists the brands,registry.models(brand)a brand's models. Names are written as the manufacturers write them; lookups ignore case, spaces and punctuation ("mitsubishi_heavy_industries"finds "Mitsubishi Heavy Industries").registry.get_device(brand, model)needs the model unless the brand has only one; there is no "generic" default. An unknown brand's error suggests the closest names.HvacState(power, mode, temperature, fan="auto", swing_v="off", swing_h="off", features={})is what you want the unit to do. Temperatures are in °C.device.encode(previous, target, actions=())returns aCommand: itssignalis the IR signal, itsstatethe target as the device can actually send it (setpoint snapped to the device's range and step, values the device lacks replaced by its defaults). Storecommand.stateand pass it back aspreviousnext time: some protocols send a toggle ("power", "swing", "light") only when the value changes.previous=Nonemeans "not known", as after a restart.
Capabilities
device.capabilities says what a device can do:
caps = device.capabilities
caps.modes # ("auto", "cool", "dry", ...)
caps.temperature.min, caps.temperature.max # the setpoint range, °C
caps.fan.values, caps.fan.labels # canonical values and their labels
caps.swing_v, caps.swing_h # Choice or None
caps.features # {"powerful": Choice, ...}
Canonical values are the same for every device ("auto", "1".."n" for
fan speeds or vane positions, "swing", "off"); labels are what the
remote calls them ("lowest", "90°", ...). Capabilities offer what the
protocol documents and pyhvac can send, nothing that would do nothing.
Formats
pyhvac.ir.formats turns a signal into a Broadlink packet (to_broadlink),
Pronto hex (to_pronto) or raw signed microseconds (to_raw), and back
(from_broadlink, from_pronto). pyhvac.ir.codec.decode(protocol, pulses)
decodes a captured signal into frames of the device's PROTOCOL.
Command line
pyhvac --list # brands (or python -m pyhvac)
python -m pyhvac --list-models Daikin # a brand's models
python -m pyhvac Daikin "ARC433**" --mode cool --temperature 24
python -m pyhvac LG "AKB74955603" --mode heat --fan 2 --format pronto
Adding a protocol
Protocol code lives in pyhvac/protocols/: a Protocol (timings, sections)
and a Device subclass whose frames() builds the frames with a Layout
(pyhvac.fields). tools/portkit.py helps derive timings, fields and
checksums from captures. Register the models in pyhvac/brands.py.
Migrating from 0.1.x
| 0.1.x | 0.2.0 |
|---|---|
importlib.import_module(f"pyhvac.plugins.{brand}").PluginObject().get_device(model) |
registry.get_device(brand, model) |
dev.set_value("mode", "cool"), set_value("temperature", 24), ... |
HvacState(power=True, mode="cool", temperature=24.0, fan=..., swing_v=..., features={...}) |
frames = dev.build_ircode(); dev.to_broadlink(frames) |
to_broadlink(device.encode(previous, state).signal) |
dev.capabilities["temperature"], dev.all_capabilities["fan"] |
device.capabilities.temperature, device.capabilities.fan (values and labels) |
scripts gaccode, gcpanasonic, gcdaikin, gclg, gcsharp |
pyhvac (or python -m pyhvac), see Command line |
brand = plugin module name, e.g. "mitsubishi_heavy_industries" |
brand as the maker writes it; lookups ignore case and punctuation, so most module names still work. Renamed: trotech -> Trotec, technopoint -> Teknopoint, vailland -> Vaillant, soleus -> Soleus Air; coolix is gone (its models are under their brands, the bare protocol is Midea "COOLIX protocol") |
| model strings of 0.1.x | the new names below; 0.1.x names still work for the former pure-Python devices (Daikin, LG and Panasonic "generic" and their variants, Airspool, Sharp "j-tech") |
The full old -> new name table is in
docs/superpowers/plans/2026-09-29-phase4/tables/names.md.
Supported models
- AEG: Chillflex Pro AXP26U338CW, Chillflex Pro AXP26U558HW, Chillflex Pro AXP34U338CW
- Airspool: AIRSPOOL protocol (remote), Mini-split
- Airton: AIRTON protocol (remote), RD1A1 (remote), SMVH09B-2A2A3NH
- Airwell: AIRWELL protocol (remote), DC Series, RC04 (remote), RC08B (remote), RC08W (remote)
- Alaska: SAC9010QC
- Amana: PBC093G00CC, YX1FF (remote)
- Amcor: ADR-853H, AMCOR protocol (remote), TAC-444 (remote), TAC-495 (remote)
- Argo: ARGO SAC_WREM2 protocol (remote), ARGO SAC_WREM3 protocol (remote), Ulisse 13 DCI, Ulisse Eco, WREM2 (remote), WREM3 (remote)
- AUX: KFR-35GW/BpNFW=3, YKR-T/011 (remote)
- Beko: BINR 070/071, RG57K7(B)/BGEF (remote)
- Bosch: B1ZAI2441W, B1ZAO2441W, BOSCH144 protocol (remote), CL3000i-Set 26 E, RG10A(G2S)BGEF (remote), RG36B4/BGE (remote)
- Carrier: 42NQV025M2 / 38NYV025M2, 42NQV035M2 / 38NYV035M2, 42NQV050M2 / 38NYV050M2, 42NQV060M2 / 38NYV060M2, 42QG5A55970 (remote), 53NGK009/012, 619EGX0090E0, 619EGX0120E0, 619EGX0180E0, 619EGX0220E0, CARRIER_AC64 protocol (remote)
- Centek: SCT-65Q09, YKR-P/002E (remote)
- Comfee: MPD1-12CRN7
- Cooper & Hunter: CH-S09FTXG, YB1F2 (remote)
- Corona: AR-01 (remote), CORONA_AC protocol (remote), CSH-N2211, CSH-N2511, CSH-N2811, CSH-N4011
- Daewoo: DSB-F0934ELH-V, GYKQ-52E (remote)
- Daichi: D-H
- Daikin: 17 Series FTXB09AXVJU, 17 Series FTXB12AXVJU, 17 Series FTXB24AXVJU, ARC423A5 (remote), ARC433** (remote), ARC433B69 (remote), ARC466A12 (remote), ARC466A33 (remote), ARC466A67 (remote), ARC477A1 (remote), ARC480A5 (remote), ARC484A4 (remote), BRC4C151 (remote), BRC4C153 (remote), BRC52B63 (remote), DAIKIN protocol (remote), DAIKIN128 protocol (remote), DAIKIN152 protocol (remote), DAIKIN160 protocol (remote), DAIKIN176 protocol (remote), DAIKIN2 protocol (remote), DAIKIN216 protocol (remote), DAIKIN312 protocol (remote), DAIKIN64 protocol (remote), DAIKIN_NATIVE protocol (remote), DGS01 (remote), FFN-C/FCN-F Series, FFQ35B8V1B, FTE12HV2S, FTQ60TV16U2, FTWX35AXV1, FTXM-M, FTXM20R5V1B, FTXZ25NV1B, FTXZ35NV1B, FTXZ50NV1B, M Series, Smash II
- Danby: DAC080BGUWDB, DAC100BGUWDB, DAC120BGUWDB, R09C/BCGE (remote)
- De'Longhi: DELONGHI_AC protocol (remote), PAC A95, PAC EM90
- Duux: Blizzard Smart 10K / DXMA04
- EcoClim: ECOCLIM protocol (remote), HYSFR-P348 (remote), ZC200DPO
- EKOKAI: GREE YAW1F protocol (remote)
- Electra: AXW12DCS, Classic INV 17, ELECTRA_AC protocol (remote), YKR-M/003E (remote)
- Electrolux: YKR-H/531E
- Eurom: EUROM protocol (remote), Polar 16CH
- Frigidaire: FGPC102AB1
- Fujitsu: AGTV14LAC, AR-DB1 (remote), AR-DL10 (remote), AR-RAC1E (remote), AR-RAE1E (remote), AR-RAH1U (remote), AR-RAH2E (remote), AR-RAH2U (remote), AR-REB1E (remote), AR-REB4E (remote), AR-REG1U (remote), AR-REW1E (remote), AR-REW4E (remote), AR-RY4 (remote), AST9RSGCW, ASTB09LBC, ASTG09K, ASTG18K, ASU12RLF, ASU30C1, ASYG09KETA-B, ASYG30LFCA, ASYG7LMCA, FUJITSU_AC ARDB1 protocol (remote), FUJITSU_AC ARJW2 protocol (remote), FUJITSU_AC ARRAH2E protocol (remote), FUJITSU_AC ARREB1E protocol (remote), FUJITSU_AC ARREW4E protocol (remote), FUJITSU_AC ARRY4 protocol (remote)
- Fujitsu General: AOHG09LLC, AR-JW17 (remote), AR-JW2 (remote), AR-RCE1E (remote), ASHG09LLCA
- GE: 6711AR2853M (remote), AG1BH09AW101
- Goodweather: GOODWEATHER protocol (remote), ZH/JT-03 (remote)
- Gree: GREE YAW1F protocol (remote), VIR09HP115V1AH, VIR12HP230V1AH, YAA1FBF (remote), YAN1F1 (remote), YAP0F8 (remote), YAPOF3 (remote), YB1F2F (remote), YX1F2F (remote)
- Green: YBOFB (remote), YBOFB2 (remote)
- Haier: HAIER_AC protocol (remote), HAIER_AC160 protocol (remote), HAIER_AC176 V9014557_A protocol (remote), HAIER_AC176 V9014557_B protocol (remote), HAIER_AC_YRW02 V9014557_A protocol (remote), HAIER_AC_YRW02 V9014557_B protocol (remote), HSU-09HMC203, HSU07-HEA03 (remote), KFR-26GW/83@UI-Ge, V9014557 M47 8D (remote), YR-W02 (remote)
- Hitachi: HITACHI_AC protocol (remote), HITACHI_AC1 R_LT0541_HTA_A protocol (remote), HITACHI_AC1 R_LT0541_HTA_B protocol (remote), HITACHI_AC264 protocol (remote), HITACHI_AC296 protocol (remote), HITACHI_AC344 protocol (remote), HITACHI_AC424 protocol (remote), KAZE-312KSDP, LT0541-HTA (remote), R-LT0541-HTA/Y.K.1.1-1 V2.3 (remote), RAK-25NH5, RAR-2P2 (remote), RAR-3U3 (remote), RAR-8P2 (remote), RAS-22NK, RAS-35THA6 (remote), RAS-70YHA3, RAS-AJ25H, RF11T1 (remote), Series VI
- Kastron: RG57A7/BGEF (remote)
- Kaysun: Casual CF, Casual CF (COOLIX)
- Kelon: ON/OFF 9000-12000
- Kelvinator: KELVINATOR protocol (remote), KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC, YALIF (remote)
- Keystone: RG57H4(B)BGEF (remote)
- Leberg: LBS-TOR07
- Lennox: M22A, M33A, M33B, MCFA, MCFB, MMDA, MMDB, MWMA, MWMA009S4-3P, MWMA012S4-3P, MWMB, RG57A6/BGEFU1 (remote)
- LG: 6711A20083V (remote), A4UW30GFA2, AKB73315611 (remote), AKB73757604 (remote), AKB74395308 (remote), AKB74955603 (remote), AKB75215403 (remote), AMNW09GSJA0, AMNW24GTPA1, Dual Inverter, Inverter V, LG_NATIVE protocol (remote), MS05SQ NW0, S4-W12JA3AA, TS-H122ERM1 (remote)
- Mabe: MMI18HDBWCA6MI8, V12843 HJ200223 (remote)
- Maxell: KKG9A-C1 (remote), MX-CH18CF
- Midea: COOLIX protocol (remote), MIDEA protocol (remote), MS12FU-10HRDN1-QRD0GW(B), MSABAU-07HRFN1-QRD0GW, RG52D/BGE (remote)
- Mirage: MIRAGE KKG29AC1 protocol (remote), MIRAGE KKG9AC1 protocol (remote), VLU series
- Mitsubishi Electric: 001CP T7WE10714 (remote), KM14A 0179213 (remote), KPOA (remote), MITSUBISHI112 protocol (remote), MITSUBISHI136 protocol (remote), MITSUBISHI_AC protocol (remote), MLZ-RX5017AS, MS-GK24VA, MSH-A24WV, MSZ-FHnnVE, MSZ-GV2519, MSZ-SF25VE3, MSZ-ZW4017S, MUH-A24WV, PAR-FA32MA (remote), PEAD-RP71JAA, RH151 (remote), RH151/M21ED6426 (remote), SG153/M21EDF426 (remote), SG15D (remote)
- Mitsubishi Heavy Industries: MITSUBISHI_HEAVY_152 protocol (remote), MITSUBISHI_HEAVY_88 protocol (remote), RKX502A001C (remote), RLA502A700B (remote), SRKxxZJ-S, SRKxxZM-S, SRKxxZMXA-S
- MRCOOL: RG57A6/BGEFU1 (remote)
- Neoclima: NEOCLIMA protocol (remote), NS-09AHTI, ZH/TY-01 (remote)
- O General: AR-RCL1E (remote)
- Panasonic: 4-Way Cassette, A75C2295 (remote), A75C2311 (remote), A75C2616-1 (remote), A75C3704 (remote), A75C3747 (remote), A75C4762 (remote), CKP series, CS-E12QKEW, CS-E7PKR, CS-E9CKP series, CS-ME10CKPG, CS-ME12CKPG, CS-ME14CKPG, CS-YW9MKD, CS-Z24RKR, CS-Z9RKR, DKE series, DKW series, JKE series, NKE series, PANASONIC_AC32 protocol (remote), PANASONIC_NATIVE protocol (remote), PKR series, PN1122V (remote), RKR series
- Pioneer System: RG66B6(B)/BGEFU1 (remote), RUBO18GMFILCAD, RYBO12GMFILCAD, UB018GMFILCFHD, WS012GMFI22HLD, WS018GMFI22HLD
- Rhoss: Idrowall MPCV 20-30-35-40, RHOSS protocol (remote)
- RusClimate: EACS/I-09HAR_X/N3, YAW1F (remote)
- Samsung: AR09FSSDAWKNFA, AR09HSFSBWKN, AR12HSSDBWKNEU, AR12KSFPEWQNET, AR12NXCXAWKXEU, AR12TXEAAWKNEU, DB93-14195A (remote), DB96-24901C (remote), SAMSUNG_AC protocol (remote)
- Sanyo: RCS-2HS4E (remote), RCS-2S4E (remote), SANYO_AC protocol (remote), SANYO_AC88 protocol (remote), SAP-K121AHA, SAP-K242AH
- Sharp: A5VEY, AH-A12REVP-1, AH-AxSAY, AH-PR13-GL, AH-XP10NRY, AY-ZP40KR, CRMC-820 JBEZ (remote), CRMC-A705 JBEZ (remote), CRMC-A863 JBEZ (remote), CRMC-A903JBEZ (remote), CRMC-A907 JBEZ (remote), CRMC-A950 JBEZ (remote), J-Tech, SHARP_AC A705 protocol (remote), SHARP_AC A903 protocol (remote), SHARP_AC A907 protocol (remote), YB1FA (remote)
- Soleus Air: TTWM1-10-01, window, ZCF/TL-05 (remote)
- Subtropic: SUB-07HN1_18Y, YKR-H/102E (remote)
- TCL: TAC-09CHSD/XA31I, TCL112AC GZ055BE1 protocol (remote), TCL112AC TAC09CHSD protocol (remote)
- Technibel: IRO PLUS, TECHNIBEL_AC protocol (remote)
- Teco: TECHNIBEL_AC protocol (remote)
- Teknopoint: Allegro SSA-09H, GZ-055B-E1 (remote)
- Tokio: AATOEMF17-12CHR1SW, RG51|50/BGE (remote)
- Toshiba: Akita EVO II, RAS 18SKP-ES, RAS-2558V, RAS-25SKVP2-ND, RAS-4M27YAV-E, RAS-B13N3KV2, RAS-B13N3KVP-E, RAS-M10YKV-E, RAS-M13YKV-E, TOSHIBA_AC protocol (remote), WC-L03SE (remote), WH-E1YE (remote), WH-TA01JE (remote), WH-TA04NE (remote), WH-UB03NJ (remote)
- Transcold: M1-F-NO-6, TRANSCOLD protocol (remote)
- Tronitechnik: KKG29A-C1 (remote), Reykir 9000
- Trotec: PAC 2100 X, PAC 3200, PAC 3550 Pro, PAC 3900 X, RG57H(B)/BGE (remote), RG57H3(B)/BGCEF-M (remote), TROTEC protocol (remote), TROTEC_3550 protocol (remote)
- Truma: 40091-86700 (remote), Aventa, TRUMA protocol (remote)
- Ultimate: Heat Pump
- Vaillant: VAI5-035WNI, YACIFB (remote)
- Vestel: BIOX CXP-9, VESTEL_AC protocol (remote)
- Voltas: 122LZF 4011252, VOLTAS kVoltas122LZF protocol (remote), VOLTAS kVoltasUnknown protocol (remote)
- Whirlpool: DG11J1-04 (remote), DG11J1-3A (remote), DG11J1-91 (remote), SPIS409L, SPIS412L, SPIW409L, SPIW412L, SPIW418L, WHIRLPOOL_AC DG11J13A protocol (remote), WHIRLPOOL_AC DG11J191 protocol (remote)
Metadata
Release files for pyhvac 0.2.0
For a detailed explanation of source distributions (sdists) and built distributions (wheels), please see the package formats documentation.
Source distribution (sdist)
| File | Size | Uploaded | Provenance | Actions |
|---|---|---|---|---|
| pyhvac-0.2.0.tar.gz | 161.4 kB | With provenance | Details for pyhvac-0.2.0.tar.gz |
Built distribution (wheel)
| File | Interpreter | ABI | Platform | Actions Reset |
|---|---|---|---|---|
| pyhvac-0.2.0-py3-none-any.whl | Python 3 | none | any | Details for pyhvac-0.2.0-py3-none-any.whl |
Total release size: 387.6 kB
Release files / pyhvac-0.2.0.tar.gz
| Download URL | pyhvac-0.2.0.tar.gz |
|---|---|
| Size | 161.4 kB |
| Tags | Source |
|
SHA-256 checksum How to use checksums |
3db0188e004dcd4e54be35cb110ec4b0a60bbd483054f75d2e8e9634dd51b81b
|
|
BLAKE2b-256 checksum How to use checksums |
c4c9cdcd9a9aeba72288ce7872d670a4372084061c686900bcaf4da1e8030809
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 14, 2026.
Transparency logRelease files / pyhvac-0.2.0-py3-none-any.whl
| Download URL | pyhvac-0.2.0-py3-none-any.whl |
|---|---|
| Size | 226.2 kB |
| Tags | Python 3 |
|
SHA-256 checksum How to use checksums |
6a2983be40776b335b78512e67d78ad11a7f44139e291dc2cfeb3040eba7b928
|
|
BLAKE2b-256 checksum How to use checksums |
4b1c2958764ef57f2a42eb5f9c152d6251dabae681d05c37b7542afdd9754d32
|
| Upload date | |
|
Uploaded using Trusted Publishing? What is trusted publishing? |
Yes |
| Uploaded via |
twine/7.0.0 CPython/3.13.16
|
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 14, 2026.
Transparency logSecurity for pyhvac 0.2.0
Provenance
Provenance describes where a file came from. On PyPI, provenance is shared via attestations, which provide a verifiable record of the build or publishing details. View details, limitations and caveats.
Full provenance
Both files in this release have been uploaded with provenance metadata.
Attestation for pyhvac-0.2.0.tar.gz
PyPI Publish Attestation
PyPI verified that this artifact, at this checksum, originated from the publisher listed below.
Signed by GitHub Actions, verified by PyPI on Nov 14, 2026.
Transparency logA note on package security
PyPI is a repository for distributing packages, not a service for auditing them. While third-party security researchers and our staff do their best to detect and remove malicious packages, PyPI cannot guarantee the quality, security or suitability of any given package.
To learn more about protecting yourself from malicious actors, visit our package security documentation.