Skip to main content

About

This is an addon for qToggleServer.

With this addon you can read and control Modbus-enabled devices (such as energy meters) via qToggleServer. You can also configure a Modbus server so that your qToggleServer behaves like a Modbus device itself.

Install

Install using pip:

pip install qtoggleserver-modbus

Usage

Serial Client

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.ModbusSerialClient"
        method = rtu                    # `ascii` (default), `rtu` or `binary`
        serial_port = "/dev/ttyUSB0"
        serial_baud = 9600              # this is the default
        serial_stopbits = 1             # this is the default
        serial_bytesize = 8             # this is the default
        serial_parity = N               # `N`, `E` or `O` (defaults to `N`)
        handle_local_echo = false       # this is the default
        # see below for common parameters
    }
    ...
]
...

Serial Server

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.ModbusSerialServer"
        method = rtu                    # `ascii` (default), `rtu` or `binary`
        serial_port = "/dev/ttyUSB0"
        serial_baud = 9600              # this is the default
        serial_stopbits = 1             # this is the default
        serial_bytesize = 8             # this is the default
        serial_parity = N               # `N`, `E` or `O` (defaults to `N`)
        # see below for common parameters
    }
    ...
]
...

TCP Client

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.ModbusTcpClient"
        method = socket                 # `socket` (default), `ascii`, `rtu` or `binary`
        tcp_host = "192.168.0.2"        # IP or hostname of the Modbus device
        tcp_port = 502                  # Modbus device TCP port
        # see below for common parameters
    }
    ...
]
...

TCP Server

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.ModbusTcpServer"
        method = socket                 # `socket` (default), `ascii`, `rtu` or `binary`
        tcp_address = "0.0.0.0"         # binds on all interfaces by default
        tcp_port = 502                  # Modbus device TCP port
        # see below for common parameters
    }
    ...
]
...

Passive Serial Client

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.PassiveModbusSerialClient"
        serial_port = "/dev/ttyUSB0"
        serial_baud = 9600              # this is the default
        serial_stopbits = 1             # this is the default
        serial_bytesize = 8             # this is the default
        serial_parity = N               # `N`, `E` or `O` (defaults to `N`)
        # see below for common parameters
    }
    ...
]
...

Passive TCP(dump) Client

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        driver = "qtoggleserver.modbus.PassiveModbusTcpClient"
        port = 5020                     # TCP port to sniff
        iface = "eth0"                  # network interface to sniff (defaults to `any`)
        master_ip = "192.168.1.122"     # IP address of the master Modbus machine (optional) 
        slave_ip = "192.168.1.123"      # IP address of the slave Modbus machine (optional)
        master_port = 5020              # TCP port of the master Modbus machine (optional) 
        slave_port = 5021               # TCP port of the slave Modbus machine (optional)
        tcpdump = "/usr/bin/tcpdump"    # full path to the `tcpdump` binary (optional) 
        # see below for common parameters
    }
    ...
]
...

Common Parameters

The following parameters are common to all types of Modbus clients and servers:

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        ...
        name = "mydevice"  # an optional name of your choice
        timeout = 5        # in seconds, this is the default
        unit_id = 1           # slave unit id, this is the default
        ports = {
            "port_id1" = {
                modbus_type = coil          # `coil`, discrete_input`, `input_register` or `holding_register`
                address = 1234              # Modbus port address (from `0000` to `9999`)
                # number of successive registers mapped to the port, starting at `address` (defaults to `1`)
                length = 2
                writable = false            # defaults to `null`, inferred from `modbus_type`
                # `struct` format to use to group multiple register values into a byte array (defaults to `>` followed
                # by `H` times `length`)
                register_group_fmt = ">HH"
                # `struct` format to use to map register byte array to port value (defaults to `>h`)
                value_fmt = ">i"
            }
            ...
        }
        ...
    }
    ...
]
...

Common Client Parameters

The following parameters are common to all types of Modbus clients:

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        ...
        use_single_functions = false  # set to `true` to use single Modbus access functions instead of multi ones
        initial_delay = 5             # the number of seconds to delay polling after connection (defaults to `0`)
        ...
    }
    ...
]
...

Common Server Parameters

The following parameters are common to all types of Modbus servers:

qtoggleserver.conf:
...
peripherals = [
    ...
    {
        ...
        identity_vendor_name = "My Vendor"
        identity_product_code = "PROD1234"
        identity_major_minor_revision = "3.14.15"
        identity_vendor_url = "https://example.com"
        identity_product_name = "My Product"
        identity_model_name = "My Model"
        identity_user_application_name = "My Custom Model"
        ...
    }
    ...
]
...

Download files

Download the file for your platform. If you're not sure which to choose, learn more about installing packages.

Source Distribution

qtoggleserver_modbus-1.5.1.tar.gz (17.4 kB view details)

Uploaded Source

Built Distribution

If you're not sure about the file name format, learn more about wheel file names.

qtoggleserver_modbus-1.5.1-py3-none-any.whl (19.6 kB view details)

Uploaded Python 3

File details

Details for the file qtoggleserver_modbus-1.5.1.tar.gz.

File metadata

  • Download URL: qtoggleserver_modbus-1.5.1.tar.gz
  • Upload date:
  • Size: 17.4 kB
  • Tags: Source
  • Uploaded using Trusted Publishing? No
  • Uploaded via: twine/7.0.0 CPython/3.13.14

File hashes

Hashes for qtoggleserver_modbus-1.5.1.tar.gz
Algorithm Hash digest
SHA256 92afe43fb413b0d5ffbd6030f5bc599ba6abee75906f17cdafe205282586c053
MD5 1739841e54306ce87be4e7776d27a0cb
BLAKE2b-256 de1feea2d684303432fad7e943e9ce6f74e9bc83d4a1210845d914aa34796ac6

See more details on using hashes here.

File details

Details for the file qtoggleserver_modbus-1.5.1-py3-none-any.whl.

File metadata

File hashes

Hashes for qtoggleserver_modbus-1.5.1-py3-none-any.whl
Algorithm Hash digest
SHA256 234fb97d36f17ef74ad0ba2a9b454fb6f9a17551e2ee01279c4dfacfcf415889
MD5 4de15c67f2b0e39c1f70ce8dbe1bbd60
BLAKE2b-256 343367fe4f34d679f243b13a3436a0f5458d1abd4dfc0f02bea8d47cca3c0a09

See more details on using hashes here.

Release history Release notifications | RSS feed

1.6.0

2 files

This release

1.5.1 This release

2 files

1.5.0

2 files

1.4.3

2 files

1.4.2

2 files

1.4.1

2 files

1.4.0

2 files

1.3.1

2 files

1.3.0

2 files

1.2.2

1 file

1.2.1

1 file

1.2.0

1 file

1.1.4

1 file

1.1.3

1 file

1.1.2

1 file

1.1.1

1 file

1.1.0

1 file

1.0.0

1 file

Supported by